928 resultados para PHYSICAL PROTECTION DEVICES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reliability of power supply is related, among other factors, to the control and protection devices allocation in feeders of distribution systems. In this way, optimized allocation of sectionalizing switches and protection devices in strategic points of distribution circuits, improves the quality of power supply and the system reliability indices. In this work, it is presented a mixed integer non-linear programming (MINLP) model, with real and binary variables, for the sectionalizing switches and protection devices allocation problem, in strategic sectors, aimed at improving reliability indices, increasing the utilities billing and fulfilling exigencies of regulatory agencies for the power supply. Optimized allocation of protection devices and switches for restoration, allows that those faulted sectors of the system can be isolated and repaired, re-managing loads of the analyzed feeder into the set of neighbor feeders. Proposed solution technique is a Genetic Algorithm (GA) developed exploiting the physical characteristics of the problem. Results obtained through simulations for a real-life circuit, are presented. © 2004 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Global climate change may induce accelerated soil organic matter (SOM) decomposition through increased soil temperature, and thus impact the C balance in soils. We hypothesized that compartmentalization of substrates and decomposers in the soil matrix would decrease SOM sensitivity to temperature. We tested our hypothesis with three short-term laboratory incubations with differing physical protection treatments conducted at different temperatures. Overall, CO2 efflux increased with temperature, but responses among physical protection treatments were not consistently different. Similar respiration quotient (Q(10)) values across physical protection treatments did not support our original hypothesis that the largest Q(10) values would be observed in the treatment with the least physical protection. Compartmentalization of substrates and decomposers is known to reduce the decomposability of otherwise labile material, but the hypothesized attenuation of temperature sensitivity was not detected, and thus the sensitivity is probably driven by the thermodynamics of biochemical reactions as expressed by Arrhenius-type equations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research aims to present a new method to get real attenuation of hearing protection devices, with good reproducibility and a small standard deviation, without relying on skills and cooperation individual. Thus the authors performed tests in 10 individuals without protection and after with two kinds of ear protections (ear plug and ear muffs), to get the threshold limit value in each of the 3 stages. For this, the research used an electrophysical exam, normally used in speech therapy, named ASSR (auditory steady-state response). The principle of this exam is put on individual’s head 3 electrodes, to capture electrical signs directly in auditory nerve. In summary, the authors presented the final results. The method proposed by ANSI (American National Standards Institute) indicated an attenuation of 27.6 dB for ear plugs, while the value found in this work was 16 dB; and for ear muffs, the ANSI method indicated 29.8 dB while the value found here was 28.5 dB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate and compare the efficacy of proximal versus distal embolus protection devices (EPD) during carotid artery angioplasty/stenting (CAS) based on diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS: Forty-four patients (31 men; mean age 68 years, range 48-85) underwent protected CAS and had DW-MRI before and after the intervention. The cohort was analyzed according to the type of EPD used: a proximal EPD was deployed in 25 (56.8%) patients (17 men; mean age 66 years, range 48-85) and a distal filter in 19 (14 men; mean age 70 years, range 58-79). Fifteen (60.0%) patients with proximal protection were symptomatic of the target lesion; in the distal protection group, 10 (52.6%) were symptomatic. RESULTS: New lesions were seen on the postinterventional DW-MRI in 28.0% (7/25) of the proximal EPD group versus 32.6% (6/19) of those with a distal filter (p = NS). The majority were clinically silent. The new lesions in the vascular territory of the stented carotid artery in the group as a whole and per patient were fewer in the proximal EPD group (p = NS). No significant differences were noted in the T(2) appearance of the new lesions or the number of new lesions observed away from the vascular territory of the stented artery. CONCLUSION: Proximal embolus protection devices show a nonsignificant trend toward fewer embolic events, which warrants large-scale studies. Furthermore, proximal protection devices can be useful to control and treat acute in-stent thrombosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação (Mestrado em Tecnologia Nuclear)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Turnover of soil organic matter (SOM) is coupled to the cycling of nutrients in soil through the activity of soil microorganisms. Biological availability of organic substrate in soil is related to the chemical quality of the organic material and to its degree of physical protection. SOM fractions can provide information on the turnover of organic matter (OM), provided the fractions can be related to functional or structural components in soil. Ultrasonication is commonly used to disrupt the soil structure prior to physical fractionation according to particle size, but may cause redistribution of OM among size fractions. The presence of mineral particles in size fractions can complicate estimations of OM turnover time within the fractions. Densiometric separation allows one to physically separate OM found within a specific size class from the heavier-density mineral particles. Nutrient contents and mineralization potential were determined for discrete size/density OM fractions isolated from within the macroaggregate structure of cultivated grassland soils. Eighteen percent of the total soil C and 25% of the total soil N in no-till soil was associated with fine-silt size particles having a density of 2.07-2.21 g/cm3 isolated from inside macroaggregates (enriched labile fraction or ELF). The amount of C and N sequestered in the ELF fraction decreased as the intensity of tillage increased. The specific rate of mineralization (mug net mineral N/mug total N in the fraction) for macroaggregate-derived ELF was not different for the three tillage treatments but was greater than for intact macroaggregates. The methods described here have improved our ability to quantitatively estimate SOM fractions, which in turn has increased our understanding of SOM dynamics in cultivated grassland systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to determine the influence of hearing protection devices (HPDs) on the understanding of speech in young adults with normal hearing, both in a silent situation and in the presence of ambient noise. The experimental research was carried out with the following variables: five different conditions of HPD use (without protectors, with two earplugs and with two earmuffs); a type of noise (pink noise); 4 test levels (60, 70, 80 and 90 dB[A]); 6 signal/noise ratios (without noise, + 5, + 10, zero, - 5 and - 10 dB); 5 repetitions for each case, totalling 600 tests with 10 monosyllables in each one. The variable measure was the percentage of correctly heard words (monosyllabic) in the test. The results revealed that, at the lowest levels (60 and 70 dB), the protectors reduced the intelligibility of speech (compared to the tests without protectors) while, in the presence of ambient noise levels of 80 and 90 dB and unfavourable signal/noise ratios (0, -5 and -10 dB), the HPDs improved the intelligibility. A comparison of the effectiveness of earplugs versus earmuffs showed that the former offer greater efficiency in respect to the recognition of speech, providing a 30% improvement over situations in which no protection is used. As might be expected, this study confirmed that the protectors' influence on speech intelligibility is related directly to the spectral curve of the protector's attenuation. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Beach profile lines at 21 near-evenly spaced intervals along Holden Beach, North Carolina, between Lockwoods Folly and Shallotte Inlets, were measured from November 1970 to December 1974. These have been analyzed to determine the spatial and temporal variabilities on long-term, seasonal, and short-term scales. Profile lines near the inlets showed the greatest variability in mean sea level (MSL) position, above MSL volume, foreshore slope, and profile envelope. This variability near Lockwoods Folly Inlet was partly enhanced by artificial nourishment at profile line 2. Temporary, low-cost shore protection devices (e.g., sandbag groins) were constructed near that inlet during part of the study. No other modifications or activities that affected beach processes were known to occur during the study period. The central part of Holden Beach was studied separately because of the high variability of the inlet sections at either end of the island. Foreshore slopes along this reach increased from an average of 1:30 at the east end to 1:17 at the west. A seasonal change in above MSL volume indicates loss of sand during autumn and winter, and gain during spring and summer. Changes in MSL shoreline intercept and above MSL volume were highly variable during the study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Computer programs have been developed to enable the coordination of fuses and overcurrent relays for radial power systems under estimated fault current conditions. The grading curves for these protection devices can be produced on a graphics terminal and a hard copy can be obtained. Additional programs have also been developed which could be used to assess the validity of relay settings (obtained under the above conditions) when the transient effect is included. Modelling of a current transformer is included because transformer saturation may occur if the fault current is high, and hence the secondary current is distorted. Experiments were carried out to confirm that distorted currents will affect the relay operating time, and it is shown that if the relay current contains only a small percentage of harmonic distortion, the relay operating time is increased. System equations were arranged to enable the model to predict fault currents with a generator transformer incorporated in the system, and also to include the effect of circuit breaker opening, arcing resistance, and earthing resistance. A fictitious field winding was included to enable more accurate prediction of fault currents when the system is operating at both lagging and leading power factors prior to the occurrence of the fault.