83 resultados para PFA
Resumo:
Poly(tetrafluoroethylene-co-perfluoropropyl vinyl ether) (PFA) with 2 mol% perfluoropropyl vinyl ether (PPVE) was exposed to gamma -irradiation in vacuum at both 77 K and room temperature and the ESR spectra recorded. Both the main chain, similar to CF2-(CF)-F-.-CF(2)similar to, and end chain, similar to (CF2CF2)-F-. radicals were identified at both temperatures and their thermal stabilities measured, No radicals unique to the radiolytic cleavage at the PPVE units were observed at room temperature, either due to the low concentration of the comonomer or beta -scission to form a chain end radical and a nonradical species. G-values for radical formation at room temperature and 77 K were found to be 0.93 and 0.16, respectively. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
For some applications for fluoropolymers they must be subjected to high-energy radiation, e.g., when they are grafted with styrene using an irradiation method to produce fuel cell membranes or matrix supports for combinatorial chemistry. In some of these applications they may be subjected to mechanical stress or elevated temperature, so it is important to elucidate the effects of the radiolysis on these properties. In the present work the effect of gamma-radiolysis on the glass transition, melting behavior, and thermal stability of PFA has been studied as well as the effect of the radiolysis on the tensile properties of the polymer.
Resumo:
Poly(tetrafluoroethylene-co-perfluoropropyI vinyl ether), PFA, was grafted with styrene from the vapor phase using a simultaneous radiation grafting method. The graft yields were measured as a function of the dose and dose rate and were found to be initially linearly dependent on the dose and independent of the dose rate up to dose rates of similar to3 kGy/h. However, at a dose rate of 6.2 kGy/h, the slope of the yield-grafting time plot decreased. Raman depth profiles of the grafts showed that the polystyrene concentrations were greatest near the surface of the grafted samples and decreased with depth. The maximum penetration depth of the graft depended on the radiation dose for a fixed dose rate. Fmoc-Rink loading tests showed that the grafts displayed superior loading compared to grafts prepared from bulk styrene or from styrene solutions other than methanol.
Resumo:
The effect of electron beam radiation on a perfluoroalkoxy (PFA) resin was examined using solid-state high-speed magic angle spinning F-19 NMR spectroscopy and FT-IR spectroscopy. Samples were prepared for analysis by subjecting them to electron beam radiation in the dose range 0.5-2.0 MGy at 633 K, which is above the crystalline melting temperature. The new structures were identified and include new saturated chain ends, short and long branches, unsaturated groups, and cross-links. The radiation chemical yield (G value) of new long branch points was greater than the G value of new chain ends, suggesting that cross-linking is the net radiolytic process. This conclusion was supported by an observed decrease in the crystallinity and an increase in the optical clarity of the polymer.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Includes index.
Resumo:
Simultaneous and preirradiation grafting of styrene onto fluorinated polyolefins does not enable control of the molecular weights or polydispersities of the styrene grafts. The nitroxide-mediated grafting of styrene onto PFA with TEMPO and TEISO using a preirradiation method has been investigated as a means of controlling the graft properties and especially to produce grafts with improved suitability for SPOC. The yields of graft were found to be in the range 15-20% for nitroxide concentrations between 5 x 10(-3) and 2 x 10(-2) M and were similar for the two nitroxides studied. Raman mapping was used to obtain the depth profile for the styrene grafts. The grafts were found to be principally located within the PFA substrate, and little graft was formed at the PFA surface. Fmoc loading tests were performed to assess the suitability of the grafted PFA as a support for SPOC, but these showed no significant loading was achieved, thus indicating that the graft properties are not suitable for SPOC. However, the study has important implications for the applications of PFA-grafted polymers in other areas, such as chemically resistant ion-exchange and separation membranes.
Resumo:
Objective - The aim of the current study was to validate child (PFA-QL) and parent–proxy (PFA-QL-PF) versions of the scale in a specialist allergy clinic and in parents of children with food allergy. Methods - For the clinic sample, a generic QoL scale (PedsQL) and the PFA-QL were completed by 103 children (age 6–16 yrs) with peanut or tree nut allergy; test–retest reliability of the PFA-QL was tested in 50 stable patients. For the non-clinical sample, 756 parents of food allergic children completed the PFA-QL-PF, the Child Health Questionnaire (CHQ-PF50), Food Allergy Quality of Life Parental Burden Scale (FAQL-PB) and a Food Allergy Impact Measure. Results - The PFA-QL and PFA-QL-PF had good internal consistency (a's of 0.77–0.82), and there was moderate-to-good agreement between the generic- and disease-specific questionnaires. The PFA-QL was stable over time in the clinic sample, and in both samples, girls were reported to have poorer QoL than boys. Conclusions - The PFA-QL and PFA-QL-PF are reliable and valid scales for use in both clinical and non-clinical populations. Unlike other available tools, they were developed and validated in the UK and thus provide a culture-specific choice for research, clinical trials and clinical practice in the UK. Validation in other countries is now needed.
Resumo:
High phosphate (Pi) levels and extracellular matrix (ECM) accumulation are associated with chronic kidney disease progression. However, how high Pi levels contribute to ECM accumulation in mesangial cells is unknown. The present study investigated the role and mechanism of high Pi levels in ECM accumulation in immortalized human mesangial cells (iHMCs). iHMCs were exposed to normal (0.9 mM) or increasing Pi concentrations (2.5 and 5 mM) with or without diferent blockers or activators. NOX4, phosphorylated AMPK (p-AMPK), phosphorylated SMAD3 (p-SMAD3), fibronectin (F/N), collagen IV (C-IV) and alpha-smooth muscle actin (α-SMA) expression was assessed via western blot and immunofluorescence. Lucigenin-enhanced chemiluminescence, and dihydroethidium (DHE) assessed NADPH oxidase activity and superoxide (SO), respectively. In iHMCs, a Pi transporter blocker (PFA) abrogated high Pi-induced AMPK inactivation, increase in NADPH oxidase-induced reactive oxygen species (ROS) levels, NOX4, p-SMAD3, α-SMA and C-IV expression. AMPK activation by AICAR, NOX4 silencing or NADPH oxidase blocker prevented high Pi-induced DHE levels, p-SMAD3, F/N, C-IV and α-SMA expression. AMPK inactivation with NOX4-induced ROS formation and transforming growth factor ß-1 (TGFß-1) signaling activation mediates high Pi-induced ECM accumulation in iHMCs. Maneuvers increasing AMPK or reducing NOX4 activity may contribute to renal protection under hyperphosphatemia.
Resumo:
Differential scanning calorimetric (DSC) and thermogravimetric analysis (TGA) have been used to study the thermal decomposition, the melting behavior and low-temperature transitions of copolymers obtained by radiation-induced grafting of styrene onto poly (tetrafluoroethylene- perfluoropropylvinylether) (PFA) substrates. PFA with different contents of perfluoropropylvinylether (PPVE) as a comonomer have been investigated. A two step degradation pattern was observed from TGA thermograms of all the grafted copolymers, which was attributed to degradation of PSTY followed by the degradation of the PFA backbone at higher temperature. One broad melting peak can be identified for all copolymers, which has two components in the samples with higher PPVE content. The melting peak, crystal-crystal transition and the degree of crystallinity of the grafted copolymers increases with radiation grafting up to 50 kGy, followed by a decrease at higher doses. No such decrease was observed in the ungrafted PFA samples after irradiation. This indicated that the changes in the heats of transitions and crystallinity at low doses are due to the radiation effects on the microstructure of PFA (chain scission), whereas at higher doses the grafted PSTY is the driving force behind these changes. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
A study has been made to investigate the radiation grafting of styrene onto poly(tetrafluoroethylene-co-perfluoropropylvinyl ether) (PFA) substrates, using the simultaneous irradiation method. Two PFA polymers of different comonomer perfluoropropyl vinyl ether (PPVE) content and degree of crystallinity were used. Effects of grafting conditions such as monomer concentrations, type of solvent, dose rate, and irradiation dose on the grafting yield were investigated. Of the six different solvents used, the most efficient in terms of increasing grafting yield were dichloromethane, benzene, and methanol. The degree of grafting increased with increasing radiation dose up to 500 kGy, stabilizing above this dose. However, the grafting yield decreased with an increase in the dose rate. The grafting of styrene onto the PFA substrates was confirmed by FTIR-ATR and micro-Raman spectroscopy, The increase in the overall grafting yield was accompanied by a proportional increase in the penetration depth of the grafts into the substrate.
Resumo:
The effect of gamma-radiation on a perfluoroalkoxy (PFA) resin was examined using solid-state high-speed magic angle spinning (MAS) F-19 NMR spectroscopy. Samples were prepared for analysis by subjecting them to gamma-radiation in the dose range 0.5-3 MGy at either 303, 473, or 573 K. New structures identified include new saturated chain ends, short and long branches, and unsaturated groups. The formation of branched structures was found to increase with increasing irradiation temperature; however, at all temperatures the radiation chemical yield (G value) of new chain ends was greater than the G value of long branch points, suggesting that chain scission is the net process.
Resumo:
This study concerns the radiation grafting of styrene onto poly(tetrafluoroethylene-co-perfluoropropylvinylether) (PFA) substrates and the penetration depth of the graft. Grafting was obtained by the simultaneous irradiation method, and the spectroscopic analysis was made with the micro-Raman technique. Effects of grafting conditions such as the type of solvent, dose rate, and irradiation dose on the grafting yield were investigated. Of the different solvents used, the most efficient in terms of increasing grafting yield were dichloromethane, benzene, and methanol, respectively. A mixture of methanol and dichloromethane used as a solvent for styrene achieved a higher degree of grafting and concentration of grafted polystyrene onto the surface of PFA substrates than solutions of the monomer in the separate solvents. The degree of grafting increased with increasing radiation dose up to 500 kGy, stabilizing above this dose. However, the grafting yield decreased with an increase in the dose rate. The increase in the overall grafting yield was accompanied by a proportional increase in the penetration depth of the grafts into the substrate. (C) 2002 Wiley Periodicals, Inc.