984 resultados para PERSONNEL DOSIMETRY


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To test the association between night work and work ability, and verify whether the type of contractual employment has any inXuence over this association. Methods Permanent workers (N = 642) and workers with precarious jobs (temporary contract or outsourced; N = 552) were interviewed and Wlled out questionnaires concerning work hours and work ability index. They were classiWed into: never worked at night, ex-night workers, currently working up to Wve nights, and currently working at least six nights/2-week span. Results After adjusting for socio-demography and work variables, current night work was signiWcantly associated with inadequate WAI (vs. day work with no experience in night work) only for precarious workers (OR 2.00, CI 1.01- 3.95 and OR 1.85, CI 1.09-3.13 for those working up to Wve nights and those working at least six nights in 2 weeks, respectively). Conclusions Unequal opportunities at work and little experience in night work among precarious workers may explain their higher susceptibility to night work

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: The purpose of the present study was to evaluate the effects of a nap at work on the sleepiness of 12-hour, night-shift (registered and assistant) nursing personnel.Methods: Twelve nurses filled out daily logs, the Karolinska Sleepiness Scale (KS), and wore wrist actigraphs for two periods of four continuous days.Results: Mean nap duration during the night shifts was 138.3 (SD+39.8) minutes. The mean sleepiness level assessed by the KS score was lower, 3.3 (SD±1.6), when the nap was taken during the first span (00:01 - 03:00h) of the night shift, compared with 6.6 (SD±1.0) when there was no nap. The mean sleepiness level assessed by the KS score was also lower, 3.6 (SD±0.9), when the nap was taken during the second span (03:01 - 06:00h) of the night shift, compared with 7.0 (SD±1.1) when there was no nap. Thus, napping either during the first or second part of the night shift reduces sleepiness of 12-hour, night-shift nursing personnel. Moreover, the mean duration of the first sleep episode after night work was longer in those who did not nap than in those who did. Conclusions: The results of this study show that napping during the 12-hour, night-shift results in less sleepiness at work and less need for recovery sleep after work

Relevância:

20.00% 20.00%

Publicador:

Resumo:

H-1- and C-13-NMR spectroscopy and FT-Raman spectroscopy are used to investigate the properties of a polymer gel dosimeter post-irradiation. The polymer gel (PACT) is composed of acrylamide, N,N'-methylene-bisacrylamide, gelatin, and water. The formation of a polyacrylamide network within the gelatin matrix follows a dose dependence nonlinearly correlated to the disappearance of the double bonds from the dissolved monomers within the absorbed dose range of 0-50 Gy. The signal from the gelatin remains constant with irradiation. We show that the NMR spin-spin relaxation times (T-2) of PAGs irradiated to up to 50 Gy measured in a NMR spectrometer and a clinical magnetic resonance imaging scanner can be modeled using the spectroscopic intensity of the growing polymer network. More specifically, we show that the nonlinear T-2 dependence against dose can be understood in terms of the fraction of protons in three different proton pools. (C) 2000 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study investigated the social rules applicable to selection interviews, and the attributions ions made by interviewers in response to rule-breaking behaviours by candidates. Sixty personnel specialists (31 males and 29 females) participated in the main study which examined their perceptions of social rules and attributions about rule breaking in their work experience. They listened to audiotapes of actual selection interviews, and made judgments about hireability communication competence, and specific social rules. Results indicated that interview rules could be categorized into two groups: specific interview presentation skills and general interpersonal competence. While situational attributions were more salient in explaining the breaking of general interpersonal competence rules, internal attributions (ability, effort) were more salient explanations for the breaking of more specific interview rules (with the exception of the preparation rule where lack of effort was the most likely explanation for rule breaking). Candidates previously judged as competent communicators were rated more favourably on both global and specific measures of rule-following competence, as well as on hireability. The theoretical and practical implications of combining social rules and attribution theory in the study of selection interviews are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in radiotherapy. (c) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It can be said that some of the topics and ideas that command our interest or attention are autobiographical in origin. This paper subscribes to this category. In this paper, I present a perspective on preparing professional personnel, namely, educators, practitioners, teachers, student teachers, and researchers, for cultural inclusion. This perspective is drawn from my experiences as a former postgraduate student from a culturally diverse background preparing for a career in severe disabilities and as a university educator who is interested in ways to encourage professionals in the field to be more cognizant of the influence of their cultural backgrounds and the value of becoming culturally inclusive.