973 resultados para PERCUTANEOUS ASPIRATION
Resumo:
Pathogenesis, classification and treatment of non-parasitic splenic cysts (NPSCs) are controversial. The utility of percutaneous aspiration of the cyst is not well understood. We report a case of a 32 year-old woman with a symptomatic giant epidermoid cyst of the spleen treated with laparoscopic splenectomy. A percutaneous transcatheter drainage was performed under ultrasound guidance before surgical procedure in order to classify the type of cyst and to choose the best treatment.
Resumo:
Background and Aims: Endoscopic ultrasound (EUS) is useful for the treatment of sterile pancreatic fluid collections (PFC), either by means of transmural drainage or by complete aspiration. The aim of this study was to evaluate the efficacy and safety of single-step EUS-guided endoscopic approaches for treatment of sterile PFC. Patients and Methods: During a 3-year period, 77 consecutive patients with symptomatic, persistent sterile PFC were evaluated and treated with the linear EUS. We excluded patients with grossly purulent collections, chronic pseudocyst and those whose cytology diagnostic was neoplastic cyst of pancreas. 44 patients received a single 10-Fr plastic straight stent under EUS or fluoroscopic control (group I) and 33 of these underwent a single-step complete aspiration with a 19-gauge needle (group II). Results: The mean size of the sterile PFC was 48 mm in group I and 28 mm in group II (p < 0.001). Overall, endoscopic treatment was successful in 70 (90.9%) patients. The mean volume aspirated was 25 (18-65) ml. The total number of procedures was 50 in group I and 41 punctures in group II. After a mean follow-up of 64 +/- 15.6 weeks there were 6 complications 13.6%): 2 recurrences (referred to surgery), 2 developing abscesses (submitted a new EUS-guided endoscopic drainage with success), 1 perforation that died (2.2%), and 1 case of bleeding (sent to surgery) in group I. In group II there were only 6 (18.1%) recurrences (submitted a new EUS-guided aspiration). None of the patients undergoing single-step aspiration developed infections, perforation or hemorrhage. Conclusion: The recurrence of pancreatic pseudocysts after endoscopic treatment was similar, either by means of plastic stents or by complete single-step aspiration. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
The abscesses of the breast are puerperal or non puerperal. The Staphylococcus aureus is the most common germ. The diagnosis is based on clinical criterias and confirmed by the ultrasonography. The percutaneous ultrasonography-guided drainage must be proposed in first intent to treat. Surgical treatment is still valid with a relapsing or chronic abscess, or after the non operative processes have failed.
Resumo:
OBJECTIVES: We sought to assess the safety and clinical efficacy of patent foramen ovale (PFO) closure under fluoroscopic guidance only, without intraprocedural echocardiography. BACKGROUND: Percutaneous PFO closure has been shown to be safe and feasible using several devices. It is generally performed using simultaneously fluoroscopic and transesophageal or intracardiac echocardiographic guidance. Transesophageal echocardiography requires sedation or general anesthesia and intubation to avoid aspiration. Intracardiac echocardiography is costly and has inherent risks. Both lengthen the procedure. The Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, Minnesota) can be safely implanted without echocardiographic guidance. METHODS: A total of 620 patients (51 +/- 12 years; 66% male) underwent PFO closure using the Amplatzer PFO Occluder for secondary prevention of presumed paradoxical embolism. Based on size and mobility of the PFO and the interatrial septum, an 18-mm device was used in 50 patients, a 25-mm device in 492, and a 35-mm device in 78. RESULTS: All procedures were successful, with 5 procedural complications (0.8%): 4 arteriovenous fistulae requiring elective surgical correction, and 1 transient ischemic attack. Contrast transesophageal echocardiography at 6 months showed complete closure in 91% of patients, whereas a minimal, moderate, or large residual shunt persisted in 6%, 2%, and 1%, respectively. During a mean follow-up period of 3.0 +/- 1.9 years (median: 2.6 years; total patient-years: 1,871), 5 ischemic strokes, 8 transient ischemic attacks, and no peripheral emboli were reported. Freedom from recurrent ischemic stroke, transient ischemic attack, or peripheral embolism was 99% at 1 year, 99% at 2 years, and 97% at 5 years. CONCLUSIONS: The Amplatzer PFO Occluder affords excellent safety and long-term clinical efficacy of percutaneous PFO closure without intraprocedural echocardiography.
Resumo:
INTRODUCTION AND OBJECTIVES There is continued debate about the routine use of aspiration thrombectomy in patients with ST-segment elevation myocardial infarction. Our aim was to evaluate clinical and procedural outcomes of aspiration thrombectomy-assisted primary percutaneous coronary intervention compared with conventional primary percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction. METHODS We performed a meta-analysis of 26 randomized controlled trials with a total of 11 943 patients. Clinical outcomes were extracted up to maximum follow-up and random effect models were used to assess differences in outcomes. RESULTS We observed no difference in the risk of all-cause death (pooled risk ratio = 0.88; 95% confidence interval, 0.74-1.04; P = .124), reinfarction (pooled risk ratio = 0.85; 95% confidence interval, 0.67-1.08; P = .176), target vessel revascularization (pooled risk ratio = 0.86; 95% confidence interval, 0.73-1.00; P = .052), or definite stent thrombosis (pooled risk ratio = 0.76; 95% confidence interval, 0.49-1.16; P = .202) between the 2 groups at a mean weighted follow-up time of 10.4 months. There were significant reductions in failure to reach Thrombolysis In Myocardial Infarction 3 flow (pooled risk ratio = 0.70; 95% confidence interval, 0.60-0.81; P < .001) or myocardial blush grade 3 (pooled risk ratio = 0.76; 95% confidence interval, 0.65-0.89; P = .001), incomplete ST-segment resolution (pooled risk ratio = 0.72; 95% confidence interval, 0.62-0.84; P < .001), and evidence of distal embolization (pooled risk ratio = 0.61; 95% confidence interval, 0.46-0.81; P = .001) with aspiration thrombectomy but estimates were heterogeneous between trials. CONCLUSIONS Among unselected patients with ST-segment elevation myocardial infarction, aspiration thrombectomy-assisted primary percutaneous coronary intervention does not improve clinical outcomes, despite improved epicardial and myocardial parameters of reperfusion. Full English text available from:www.revespcardiol.org/en.
Resumo:
Funding/Support and role of the sponsor: None.
Resumo:
Funding/Support and role of the sponsor: None.
Resumo:
The purpose of this study was to assess the efficacy and reproducibility of the cytologic diagnosis of salivary gland tumors (SGTs) using fine-needle aspiration cytology (FNAC). The study aimed to determine diagnostic accuracy, sensitivity, and specificity and to evaluate the extent of interobserver agreement. We retrospectively evaluated SGTs from the files of the Division of Pathology at the Clinics Hospital of São Paulo and Piracicaba Dental School between 2000 and 2006. We performed cytohistologic correlation in 182 SGTs. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 94%, 100%, 100%, 100%, and 99%, respectively. The interobserver cytologic reproducibility showed significant statistical concordance (P < .0001). FNAC is an effective tool for performing a reliable preoperative diagnosis in SGTs and shows high diagnostic accuracy and consistent interobserver reproducibility. Further FNAC studies analyzing large samples of malignant SGTs and reactive salivary lesions are needed to confirm their accuracy.
Resumo:
Facial cosmetic procedures are increasingly requested, and dermal filler materials have been widely used as a nonsurgical option since the 1980s. However, injectable fillers have been implicated in local adverse reactions. Therefore, the aim of this article was to describe the use of fine needle aspiration cytology (FNAC) in the diagnosis of foreign-body reactions to the perioral injection of dermal fillers. A 69-year-old woman presented with a painful nodule on her right nasolabial fold. Intraoral FNAC was performed, and cytologic smears were examined under optical and polarized light microscopy, showing birefringent microspheres, confirming the diagnosis of an adverse reaction caused by polymethyl methacrylate filler. FNAC is a less invasive method to confirm the diagnosis of adverse reactions caused by perioral cosmetic dermal fillers.
Resumo:
The recently-proposed Bethesda reporting system has offered clinical recommendations for each category of reported thyroid cytology, including repeated fine-needle aspiration (FNA) for non-diagnostic and atypia/follicular lesions of undetermined significance, but there are no sound indications for repeated examination after an initial benign exam. To investigate the clinical validity of repeated FNA in the management of patients with thyroid nodules. The present study evaluated 412 consecutive patients who had repeated aspiration biopsies of thyroid nodules after an initial non-diagnostic, atypia/follicular lesion of undetermined significance, or benign cytology. The majority of patients were female (93.5%) ranging from 13 to 83 years. Non-diagnostic cytology was the most common indication for a repeated examination in 237 patients (57.5%), followed by benign (36.8%), and A/FLUS (5.6%) cytology. A repeated examination altered the initial diagnosis in 70.5% and 78.3% of the non-diagnostic and A/FLUS patients, respectively, whereas only 28.9% of patients with a benign cytology presented with a different diagnosis on a sequential FNA. Repeat FNA is a valuable procedure in cases with initial non-diagnostic or A/FLUS cytology, but its routine use for patients with an initial benign examination appears to not increase the expected likelihood of a malignant finding.
Resumo:
The objective of the current study was to evaluate the sensitivity, specificity and accuracy of fine needle aspiration biopsy (FNAB) of submucous nodules from the oral cavity and head and neck region as an auxiliary diagnostic tool. Fifty patients with nodule lesions in the oral cavity and the head and neck region were selected. All of them were submitted to FNAB and to either incisional or excisional biopsy. The diagnoses from the FNABs were compared with the biopsy diagnosis as the gold standard. All the cases of FNAB were analyzed by a single oral pathologist prior to the biopsy diagnosis. The results showed that the sensitivity of FNAB was 75%, its specificity was 96% and its accuracy was 58.8%. The false positive and false negative rates were 6.7% and 13.3%, respectively. The positive predictive value was 86% and the negative predictive value was 93%. The inconclusive rate was 16/50. FNAB displayed a high success rate for identifying both malignant and benign lesions, but a low accuracy for making a final diagnosis.
Resumo:
It was intended to examine the in vitro penetration of cisplatin (CIS) through porcine skin in the presence of different concentrations of monoolein (MO) as well as to verify the main barrier for CIS skin penetration. In vitro skin penetration of CIS was studied from propylene glycol (PG) solutions containing 0%, 5%, 10%, and 20% of MO using Franz-type diffusion cell and porcine ear skin. Pretreatment experiments with MO and experiments with skin without stratum corneum (SC) were also carried out. Skin penetration studies of CIS showed that the presence of MO doubled the drug permeation through the intact skin. However, permeation studies through the skin without SC caused only a small enhancement of CIS permeation compared to intact skin. Moreover, pretreatment of skin with MO formulations did not show any significant increase in the flux of the drug. In conclusion, MO did not act as a real penetration enhancer for CIS, but it increased the drug partition to the receptor solution improving CIS transdermal permeation. The absence of improvement in drug permeation by MO pretreatment and by the removal of SC indicates that the SC is not the main barrier for the permeation of the metal coordination compound. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
A number of mathematical models have been used to describe percutaneous absorption kinetics. In general, most of these models have used either diffusion-based or compartmental equations. The object of any mathematical model is to a) be able to represent the processes associated with absorption accurately, b) be able to describe/summarize experimental data with parametric equations or moments, and c) predict kinetics under varying conditions. However, in describing the processes involved, some developed models often suffer from being of too complex a form to be practically useful. In this chapter, we attempt to approach the issue of mathematical modeling in percutaneous absorption from four perspectives. These are to a) describe simple practical models, b) provide an overview of the more complex models, c) summarize some of the more important/useful models used to date, and d) examine sonic practical applications of the models. The range of processes involved in percutaneous absorption and considered in developing the mathematical models in this chapter is shown in Fig. 1. We initially address in vitro skin diffusion models and consider a) constant donor concentration and receptor conditions, b) the corresponding flux, donor, skin, and receptor amount-time profiles for solutions, and c) amount- and flux-time profiles when the donor phase is removed. More complex issues, such as finite-volume donor phase, finite-volume receptor phase, the presence of an efflux. rate constant at the membrane-receptor interphase, and two-layer diffusion, are then considered. We then look at specific models and issues concerned with a) release from topical products, b) use of compartmental models as alternatives to diffusion models, c) concentration-dependent absorption, d) modeling of skin metabolism, e) role of solute-skin-vehicle interactions, f) effects of vehicle loss, a) shunt transport, and h) in vivo diffusion, compartmental, physiological, and deconvolution models. We conclude by examining topics such as a) deep tissue penetration, b) pharmacodynamics, c) iontophoresis, d) sonophoresis, and e) pitfalls in modeling.
Resumo:
Proteinuria was associated with cardiovascular events and mortality in community-based cohorts. The association of proteinuria with mortality and cardiovascular events in patients undergoing percutaneous coronary intervention (PCI) was unknown. The association of urinary dipstick proteinuria with mortality and cardiovascular events (composite of death, myocardial infarction, or nonhemorrhagic stroke) in 5,835 subjects of the EXCITE trial was evaluated. Dipstick urinalysis was performed before PCI, and proteinuria was defined as trace or greater. Subjects were followed up for 210 days/7 months after enrollment for the occurrence of events. Multivariate Cox regression analysis evaluated the independent association of proteinuria with each outcome. Mean age was 59 years, 21% were women, 18% had diabetes mellitus, and mean estimated glomerular filtration rate was 90 ml/min/1.73 m(2). Proteinuria was present in 750 patients (13%). During follow-up, 22 subjects (2.9%) with proteinuria and 54 subjects (1.1%) without proteinuria died (adjusted hazard ratio 2.83, 95% confidence interval [CI] 1.65 to 4.84, p <0.001). The severity of proteinuria attenuated the strength of the association with mortality after PCI (low-grade proteinuria, hazard ratio 2.67, 95% CI 1.50 to 4.75; high-grade proteinuria, hazard ratio 3.76, 95% CI 1.24 to 11.37). No significant association was present for cardiovascular events during the relatively short follow-up, but high-grade proteinuria tended toward increased risk of cardiovascular events (hazard ratio 1.45, 95% CI 0.81 to 2.61). In conclusion, proteinuria was strongly and independently associated with mortality in patients undergoing PCI. These data suggest that such a relatively simple and clinically easy to use tool as urinary dipstick may be useful to identify and treat patients at high risk of mortality at the time of PCI. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:1151-1155)