933 resultados para PERCEPTUAL RATINGS


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study compared the effects of a low-frequency electrical stimulation (LFES; Veinoplus® Sport, Ad Rem Technology, Paris, France), a low-frequency electrical stimulation combined with a cooling vest (LFESCR) and an active recovery combined with a cooling vest (ACTCR) as recovery strategies on performance (racing time and pacing strategies), physiologic and perceptual responses between two sprint kayak simulated races, in a hot environment (∼32 wet-bulb-globe temperature). Eight elite male kayakers performed two successive 1000-m kayak time trials (TT1 and TT2), separated by a short-term recovery period, including a 30-min of the respective recovery intervention protocol, in a randomized crossover design. Racing time, power output, and stroke rate were recorded for each time trial. Blood lactate concentration, pH, core, skin and body temperatures were measured before and after both TT1 and TT2 and at mid- and post-recovery intervention. Perceptual ratings of thermal sensation were also collected. LFESCR was associated with a very likely effect in performance restoration compared with ACTCR (99/0/1%) and LFES conditions (98/0/2%). LFESCR induced a significant decrease in body temperature and thermal sensation at post-recovery intervention, which is not observed in ACTCR condition. In conclusion, the combination of LFES and wearing a cooling vest (LFESCR) improves performance restoration between two 1000-m kayak time trials achieved by elite athletes, in the heat.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of prosthetic devices for correction of velopharyngeal insufficiency (VPI) is an alternative treatment for patients with conditions that preclude surgery and for those individuals with a hypofunctional velopharynx (HV) with a poor prognosis for the surgical repair of VPI. Understanding the role and measuring the outcome of prosthetic treatment of velopharyngeal dysfunction requires the use of tools that allow for documenting pre- and post-treatment outcomes. Experimental openings in speech bulbs have been used for simulating VPI in studies documenting changes in aerodynamic, acoustic and kinematics aspects of speech associated with the use of palatal prosthetic devices. The use of nasometry to document changes in speech associated with experimental openings in speech bulbs, however, has not been described in the literature. Objective: This single-subject study investigated nasalance and nasality at the presence of experimental openings drilled through the speech bulb of a patient with HV. Material and Methods: Nasometric recordings of the word "pato" were obtained under 4 velopharyngeal conditions: no-opening (control condition), no speech bulb, speech bulb with a 20 mm(2) opening, and speech bulb with 30 mm(2) opening. Five speech-language pathologists performed auditory-perceptual ratings while the subject read an oral passage under all conditions. Results: Kruskal-Wallis test showed significant difference among conditions (p=0.0002), with Scheffe post hoc test indicating difference from the no-opening condition. Conclusion: The changes in nasalance observed after drilling holes of known sizes in a speech bulb suggest that nasometry reflect changes in transfer of sound energy related to different sizes of velopharyngeal opening.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The literature suggests that individuals with history of cleft lip and palate who present with midfacial growth deficiency are at higher risk of presenting lisping. The relationship between distortions during production of linguoalveolar fricative sounds and the severity of malocclusion, however, has not been established for the population with cleft. Objective: To study the association between lisping and dental arch relationship. Methodology: Speech samples and dental arch casts were obtained from 106 children with operated unilateral cleft lip and palate (UCLP) during the stage of mixed dentition and before orthodontic treatment. Videotaped productions of the phrase/u saci saiw sedu/were rated by speech-language pathologists for the identification of lisping during [s]. Dental arch casts were rated by orthodontists using the Goslon Yardstick and the Five-Year Index to establish dental arch relationship. Results: Multiple logistic regression showed no significant association between lisping and dento-occlusal index (p = .802) and age (p = .662). Substantial interjudge agreement during auditory-perceptual ratings was found (kappa = .63). Almost perfect agreement was found between orthodontists while establishing the dental arch relationship (kappa = .81). Discussion: This study failed to reveal an association between lisping and dental arch relationship in children with operated UCLP. Multiple variables may play a role in determining occurrence of lisping, warranting further investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives. To evaluate whether the overall dysphonia grade, roughness, breathiness, asthenia, and strain (GRBAS) scale, and the Consensus Auditory Perceptual Evaluation-Voice (CAPE-V) scale show the same reliability and consensus when applied to the same vocal sample at different times. Study Design. Observational cross-sectional study. Methods. Sixty subjects had their voices recorded according to the tasks proposed in the CAPE-V scale. Vowels /a/ and /i/ were sustained between 3 and 5 seconds. Reproduction of six sentences and spontaneous speech from the request "Tell me about your voice" were analyzed. For the analysis of the GRBAS scale, the sustained vowel and reading tasks of the sentences was used. Auditory-perceptual voice analyses were conducted by three expert speech therapists with more than 5 years of experience and familiar with both the scales. Results. A strong correlation was observed in the intrajudge consensus analysis, both for the GRBAS scale as well as for CAPE-V, with intraclass coefficient values ranging from 0.923 to 0.985. A high degree of correlation between the general GRBAS and CAPE-V grades (coefficient = 0.842) was observed, with similarities in the grades of dysphonia distribution in both scales. The evaluators indicated a mild difficulty in applying the GRBAS scale and low to mild difficulty in applying the CAPE-V scale. The three evaluators agreed when indicating the GRBAS scale as the fastest and the CAPE-V scale as the most sensitive, especially for detecting small changes in voice. Conclusions. The two scales are reliable and are indicated for use in analyzing voice quality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivos: estabelecer amostras de referência constituídas por gravações julgadas com consenso como representativas da presença ou ausência da oclusiva glotal (OG) e comparar julgamentos perceptivo-auditivos da presença e ausência da OG com e sem o uso de amostras de referência. Metodologia: o estudo foi dividido em duas etapas. Durante a ETAPA 1, 480 frases referentes aos sons oclusivos e fricativos produzidas por falantes com história de fissura labiopalatina foram julgadas por três fonoaudiólogas experientes quanto à identificação da OG. As frases foram julgadas individualmente e aquelas que não apresentaram consenso inicial foram julgadas novamente de maneira simultânea. As amostras julgadas com consenso com relação à presença ou ausência da OG durante produção das seis consoantes-alvo oclusivas e seis fricativas foram selecionadas para estabelecer um Banco de Amostras Representativas da OG. A ETAPA 2 consistiu na seleção de 48 amostras de referência referentes aos 12 sons de interesse e 120 amostras experimentais e, o julgamento dessas amostras experimentais por três grupos de juízes, cada grupo com três juízes com experiências distintas com relação ao julgamento de fala na fissura de palato. Os juízes julgaram as amostras experimentais duas vezes, primeiro sem acesso às referências e, após uma semana, com acesso às referências. Resultados: os julgamentos realizados na ETAPA 1 evidenciaram consenso com relação a OG em 352 amostras, sendo 120 frases com produção adequada para os sons de interesse e 232 representativas do uso da OG. Essas 352 amostras constituíram o Banco de amostras Representativas da OG. Os resultados da ETAPA 2 indicaram que ao comparar a média do valor de Kappa obtida para os 12 sons de interesse em cada um dos grupos nos julgamentos sem e com acesso às amostras de referência a concordância para o grupo 1 (G1) passou de regular (K=0,35) para moderada (K=0,55), para o grupo 2 (G2) passou de moderada (K=0,44) para substancial (K=0,76) e para o grupo 3 (G3) passou de substancial (K=0,72) para quase perfeita (K=0,83). Observou-se que as melhores concordâncias ocorreram para o grupo dos fonoaudiólogos experientes (G3), seguido dos fonoaudiólogos recém-formados (G2), com as piores observadas para o grupo de alunos de graduação (G1). Conclusão: um Banco de Amostras de Referência Representativas da OG foi estabelecido e os julgamentos perceptivo-auditivos de juízes com uso das amostras de referência foram obtidos com concordância inter-juízes e porcentagem de acertos melhor do que os julgamentos sem acesso às referências. Os resultados sugerem a importância do uso de amostras de referência para minimizar a subjetividade da avaliação perceptivo auditiva da fala.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This pilot study explored the feasibility and effectiveness of an Internet-based telerehabilitation application for the assessment of motor speech disorders in adults with acquired neurological impairment. Method: Using a counterbalanced, repeated measures research design, 2 speech-language pathologists assessed 19 speakers with dysarthria on a battery of perceptual assessments. The assessments included a 19-item version of the Frenchay Dysarthria Assessment (FDA; P. Enderby, 1983), the Assessment of Intelligibility of Dysarthric Speech (K. M. Yorkston & D. R. Beukelman, 1981), perceptual analysis of a speech sample, and an overall rating of severity of the dysarthria. One assessment was conducted in the traditional face-to-face manner, whereas the other assessment was conducted using an online, custom-built telerehabilitation application. This application enabled real-time videoconferencing at 128 kb/s and the transfer of store-and-forward audio and video data between the speaker and speech-language pathologist sites. The assessment methods were compared using the J.M.Bland and D.G.Altman (1986, 1999) limits-of-agreement method and percentage level of agreement between the 2 methods. Results: Measurements of severity of dysarthria, percentage intelligibility in sentences, and most perceptual ratings made in the telerehabilitation environment were found to fall within the clinically acceptable criteria. However, several ratings on the FDA were not comparable between the environments, and explanations for these results were explored. Conclusions: The online assessment of motor speech disorders using an Internet-based telerehabilitation system is feasible. This study suggests that with additional refinement of the technology and assessment protocols, reliable assessment of motor speech disorders over the Internet is possible. Future research methods are outlined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Explosive ordnance disposal (EOD) often requires technicians to wear multiple protective garments in challenging environmental conditions. The accumulative effect of increased metabolic cost coupled with decreased heat dissipation associated with these garments predisposes technicians to high levels of physiological strain. It has been proposed that a perceptual strain index (PeSI) using subjective ratings of thermal sensation and perceived exertion as surrogate measures of core body temperature and heart rate, may provide an accurate estimation of physiological strain. Therefore, this study aimed to determine if the PeSI could estimate the physiological strain index (PSI) across a range of metabolic workloads and environments while wearing heavy EOD and chemical protective clothing. Methods Eleven healthy males wore an EOD and chemical protective ensemble while walking on a treadmill at 2.5, 4 and 5.5 km·h− 1 at 1% grade in environmental conditions equivalent to wet bulb globe temperature (WBGT) 21, 30 and 37 °C. WBGT conditions were randomly presented and a maximum of three randomised treadmill walking trials were completed in a single testing day. Trials were ceased at a maximum of 60-min or until the attainment of termination criteria. A Pearson's correlation coefficient, mixed linear model, absolute agreement and receiver operating characteristic (ROC) curves were used to determine the relationship between the PeSI and PSI. Results A significant moderate relationship between the PeSI and the PSI was observed [r = 0.77; p < 0.001; mean difference = 0.8 ± 1.1 a.u. (modified 95% limits of agreement − 1.3 to 3.0)]. The ROC curves indicated that the PeSI had a good predictive power when used with two, single-threshold cut-offs to differentiate between low and high levels of physiological strain (area under curve: PSI three cut-off = 0.936 and seven cut-off = 0.841). Conclusions These findings support the use of the PeSI for monitoring physiological strain while wearing EOD and chemical protective clothing. However, future research is needed to confirm the validity of the PeSI for active EOD technicians operating in the field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Perceptual integration of sensory input from our two nostrils has received little attention in comparison to lateralized inputs for vision and hearing. Here, we investigated whether a binary odor mixture of eugenol and l-carvone (smells of cloves and caraway) would be perceived differently if presented as a mixture in one nostril (physical mixture), vs. the same two odorants in separate nostrils (dichorhinic mixture). In parallel, we investigated whether the different types of presentation resulted in differences in olfactory event-related potentials (OERP). Psychophysical ratings showed that the dichorhinic mixtures were perceived as more intense than the physical mixtures. A tendency for shift in perceived quality was also observed. In line with these perceptual changes, the OERP showed a shift in latencies and amplitudes for early (more "sensory") peaks P1 and N1 whereas no significant differences were observed for the later (more "cognitive") peak P2. The results altogether suggest that the peripheral level is a site of interaction between odorants. Both psychophysical ratings and, for the first time, electrophysiological measurements converge on this conclusion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In motion standstill, a quickly moving object appears to stand still, and its details are clearly visible. It is proposed that motion standstill can occur when the spatiotemporal resolution of the shape and color systems exceeds that of the motion systems. For moving red-green gratings, the first- and second-order motion systems fail when the grating is isoluminant. The third-order motion system fails when the green/red saturation ratio produces isosalience (equal distinctiveness of red and green). When a variety of high-contrast red-green gratings, with different spatial frequencies and speeds, were made isoluminant and isosalient, the perception of motion standstill was so complete that motion direction judgments were at chance levels. Speed ratings also indicated that, within a narrow range of luminance contrasts and green/red saturation ratios, moving stimuli were perceived as absolutely motionless. The results provide further evidence that isoluminant color motion is perceived only by the third-order motion system, and they have profound implications for the nature of shape and color perception.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of the present study were to compare the perceptual assessments of deviant speech signs (dysarthria) exhibited by Australian and Swedish speakers with multiple sclerosis (MS) and to explore whether judgements of dysarthria differed depending on whether the speakers and the judges spoke the same or different languages. Ten Australian and 10 Swedish individuals with MS (matched as closely as possible for age, gender, progression type and severity of dysarthria) were assessed by 2 Australian and 2 Swedish clinically experienced judges using a protocol including 33 speech parameters. Results show that the following perceptual dimensions were identified by both pairs of judges in both groups of speakers to a just noticeable or moderate degree: imprecise consonants, inappropriate pitch level, reduced general rate, and glottal fry. The reliability (Spearman rank-order correlation) of the consensus ratings from the Australian and the Swedish judges was high, with a mean rho of 85.7 for the Australian speakers and mean rho of 84.3 for the Swedish speakers. The most difficult perceptual parameters to assess (i.e. to agree on) included harshness, level of pitch and loudness, precision of consonants and general stress pattern. The study indicated that perceptual assessments of speech characteristics in individuals with MS are informative and can be achieved with high inter-judge reliability irrespective of the judge's knowledge of the speaker's language. Copyright (C) 2003 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using artificial neural networks (ANN) and ordinal regression (OR) as alternative methods to predict LPT bond ratings, we examine the role that various financial and industry variables have on Listed Property Trust (LPT) bond ratings issued by Standard and Poor’s from 1999-2006. Our study shows that both OR and ANN provide robust alternatives to rating LPT bonds and that there are no significant differences in results between the two full models. OR results show that of the financial variables used in our models, debt coverage and financial leverage ratios have the most profound effect on LPT bond ratings. Further, ANN results show that 73.0% of LPT bond rating is attributable to financial variables and 23.0% to industry-based variables with office LPT sector accounting for 2.6%, retail LPT 10.9% and stapled management structure 13.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This present paper reviews the reliability and validity of visual analogue scales (VAS) in terms of (1) their ability to predict feeding behaviour, (2) their sensitivity to experimental manipulations, and (3) their reproducibility. VAS correlate with, but do not reliably predict, energy intake to the extent that they could be used as a proxy of energy intake. They do predict meal initiation in subjects eating their normal diets in their normal environment. Under laboratory conditions, subjectively rated motivation to eat using VAS is sensitive to experimental manipulations and has been found to be reproducible in relation to those experimental regimens. Other work has found them not to be reproducible in relation to repeated protocols. On balance, it would appear, in as much as it is possible to quantify, that VAS exhibit a good degree of within-subject reliability and validity in that they predict with reasonable certainty, meal initiation and amount eaten, and are sensitive to experimental manipulations. This reliability and validity appears more pronounced under the controlled (but more arti®cial) conditions of the laboratory where the signal : noise ratio in experiments appears to be elevated relative to real life. It appears that VAS are best used in within-subject, repeated-measures designs where the effect of different treatments can be compared under similar circumstances. They are best used in conjunction with other measures (e.g. feeding behaviour, changes in plasma metabolites) rather than as proxies for these variables. New hand-held electronic appetite rating systems (EARS) have been developed to increase reliability of data capture and decrease investigator workload. Recent studies have compared these with traditional pen and paper (P&P) VAS. The EARS have been found to be sensitive to experimental manipulations and reproducible relative to P&P. However, subjects appear to exhibit a signi®cantly more constrained use of the scale when using the EARS relative to the P&P. For this reason it is recommended that the two techniques are not used interchangeably