390 resultados para PCM Condenser
Resumo:
A battery powered air-conditioning device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The main focus of the current research was on the development of the cooling system. The cooling capacity of the vapor compression cycle measured was 165.6 W with system COP at 2.85. It was able to provide 2 hours cooling without discharging heat to the ambient. The PCM was recharged in nearly 8 hours under thermosiphon mode.
Resumo:
Aim: To demonstrate that the evaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens (LMLC) is useful to identify patients with a haematuria of glomerular or non-glomerular origin. Methods: A comparative double-blind study between phase contrast microscopy (PCM) and LMLC is reported to evaluate the efficacy of these techniques. Urine samples of 39 patients followed up for 9 months were analyzed, and classified as glomerular and non-glomerular haematuria. The different microscopic techniques were compared using receiver-operator curve (ROC) analysis and area under curve (AUC). Reproducibility was assessed by coefficient of variation (CV). Results: Specific cut-offs were set for each method according to their best rate of specificity and sensitivity as follows: 30% for phase contrast microscopy and 40% for standard LMLC, reaching in the first method the rate of 95% and 100% of sensitivity and specificity, respectively, and in the second method the rate of 90% and 100% of sensitivity and specificity, respectively. In ROC analysis, AUC for PCM was 0.99 and AUC for LMLC was 0.96. The CV was very similar in glomerular haematuria group for PCM (35%) and LMLC (35.3%). Conclusion: LMLC proved to be effective in contributing to the direction of investigation of haematuria, toward the nephrological or urological side. This method can substitute PCM when this equipment is not available.
Resumo:
The solvent effects on the low-lying absorption spectrum and on the (15)N chemical shielding of pyrimidine in water are calculated using the combined and sequential Monte Carlo simulation and quantum mechanical calculations. Special attention is devoted to the solute polarization. This is included by an iterative procedure previously developed where the solute is electrostatically equilibrated with the solvent. In addition, we verify the simple yet unexplored alternative of combining the polarizable continuum model (PCM) and the hybrid QM/MM method. We use PCM to obtain the average solute polarization and include this in the MM part of the sequential QM/MM methodology, PCM-MM/QM. These procedures are compared and further used in the discrete and the explicit solvent models. The use of the PCM polarization implemented in the MM part seems to generate a very good description of the average solute polarization leading to very good results for the n-pi* excitation energy and the (15)N nuclear chemical shield of pyrimidine in aqueous environment. The best results obtained here using the solute pyrimidine surrounded by 28 explicit water molecules embedded in the electrostatic field of the remaining 472 molecules give the statistically converged values for the low lying n-pi* absorption transition in water of 36 900 +/- 100 (PCM polarization) and 36 950 +/- 100 cm(-1) (iterative polarization), in excellent agreement among one another and with the experimental value observed with a band maximum at 36 900 cm(-1). For the nuclear shielding (15)N the corresponding gas-water chemical shift obtained using the solute pyrimidine surrounded by 9 explicit water molecules embedded in the electrostatic field of the remaining 491 molecules give the statistically converged values of 24.4 +/- 0.8 and 28.5 +/- 0.8 ppm, compared with the inferred experimental value of 19 +/- 2 ppm. Considering the simplicity of the PCM over the iterative polarization this is an important aspect and the computational savings point to the possibility of dealing with larger solute molecules. This PCM-MM/QM approach reconciles the simplicity of the PCM model with the reliability of the combined QM/MM approaches.
Resumo:
A relação entre consciência fonológica e consciência morfológica e a contribuição independente de cada uma para a aprendizagem da leitura não reúnem ainda consenso na literatura. Alguns autores argumentam que a consciência morfológica não contribui de forma independente da consciência fonológica para a aprendizagem da leitura. No entanto, outros encontraram dados que indicam que a consciência morfológica tem um papel específi co na progressão da aprendizagem da leitura. Todavia, para além da variedade de tarefas usadas não permitir a comparação de resultados, a ausência de estudos prévios sobre a validade e a fi delidade das mesmas conduz a resultados cuja confi abilidade pode ser posta em causa. Este estudo tem como objetivo apresentar uma análise das qualidades psicométricas da PCM - Prova de Consciência Morfológica. A amostra é constituída por 243 crianças do 2.º (n = 79), 3.º (n = 83) e 4.º (n = 81) anos frequentando escolas públicas, urbanas, do distrito do Porto (norte de Portugal). Os resultados revelaram que a PCM possui uma elevada consistência interna (α = .95). Na análise em componentes principais, foi extraído um único fator, com valor próprio igual a 10.88, que explica 54.42% da variância total dos resultados. Os itens são todos saturados no fator, variando as saturações fatoriais entre um mínimo de .42 e o máximo de .91
Resumo:
A União Europeia tem dado cada vez mais enfoque à eficiência energética nos edifícios e à sua capacidade de produção de energia, tendo lançado a directiva “Energy Performance of Buildings Directive” com o intuito de que até 31 de Dezembro de 2018 todos os edifícios novos sejam “nZEB-nearly Zero Energy Building”, o que significa que devem por um lado diminuir o seu consumo energético, aumentando a sua eficiência, e por outro lado produzir localmente e através de fontes de energias renováveis toda, ou quase toda, a energia de que necessitam. A presente tese está integrada no Projecto “Frame – Prefabricated systems (modules) for low-energy buildings: design, prototyping and testing” (Ref: PTDC/AURAQI-AQI/117782/2010) que está a ser desenvolvido na Unidade de Eficiência Energética do Laboratório Nacional de Energia e Geologia (LNEG). Neste trabalho é desenvolvido e analisado um sistema BIPV/T-PCM (Building Integrated Photovoltaic Thermal – Phase Change Materials) que engloba todo um novo conceito de captação, armazenamento e gestão da energia solar em fachadas. Este sistema é composto por um módulo fotovoltaico, uma bateria de PCM (Materiais de Mudança de Fase) e todo um sistema de fluxo de ar que permite a gestão da energia colectada e armazenada. Foi também desenvolvido teoricamente um código de gestão energética para a manipulação do sistema. O sistema em estudo apoia-se em três objectivos principais: aquecer no inverno; arrefecer no verão; e aumentar a eficiência do PV arrefecendo-o. Na sequência do trabalho realizado verificou-se que o conceito do sistema em estudo alcança alguns dos objectivos propostos, tendo ainda potencial para se continuar o seu desenvolvimento. O sistema em estudo é um sistema inovador, e como tal está a ser registada uma patente com base no conceito desenvolvido.
Resumo:
Este trabalho visa, em primeiro lugar, a caracterização experimental do comportam ento de argamassas com materiais de mudança de fase (PCM) incorporados através de agregados leves, comparativamente com argamassas de referência sem incorporação de PCM. Verifica-se que a aplicação de argamassas com PCM em camadas de desgaste de pavimentos contribui para a minimização dos potenciais efeitos negativos de gelo e degelo. Os estudos experimentais permitem concluir que o método utilizado de impregnação de PCM em materiais porosos, para posterior incorporação em argamassa ou betão, é um método simples, mas muito eficaz. Os resultados indicam ainda que os materiais compósitos com PCM incorporado, podem melhorar a inércia térmica, bem como, atrasar o tempo de eventual ocorrência de congelamento sob a camada de desgaste de um pavimento
Resumo:
Currently we are witnessing a huge concern of society with the parameters of comfort of the buildings and the energetic consumptions. It is known that there is a huge consumption of non-renewable sources of energy. Thus, it is urgent to develop and explore ways to take advantage of renewable sources of energy by improving the energy efficiency of buildings. The mortars with incorporation of phase change materials (PCM) have the ability to regulate the temperature inside buildings, contributing to the thermal comfort and reduction of the use of heating and cooling equipment, using only the energy supplied by the sun. However, the incorporation of phase change materials in mortars modifies its characteristics. The main purpose of this study was mechanical and thermal characterization of mortars with incorporation of PCM in mortars based in different binders. The binders studied were aerial lime, hydraulic lime, gypsum and cement. For each type of binder a reference composition (0% PCM) and a composition with incorporation of 40% of PCM were developed. It was possible to observe that the incorporation of PCM in mortars caused differences in properties such as workability, compressive strength, flexural strength and adhesion, however leads to an improvement of thermal behavior.
Resumo:
This paper proposes a methodology for improvement of energy efficiency in buildings through the innovative simultaneous incorporation of three distinct phase change materials (here termed as hybrid PCM) in plastering mortars for façade walls. The thermal performance of a hybrid PCM mortar was experimentally evaluated by comparing the behaviour of a prototype test cell (including hybrid PCM plastering mortar) subjected to realistic daily temperature profiles, with the behaviour of a similar prototype test cell, in which no PCM was added. A numerical simulation model was employed (using ANSYS-FLUENT) to validate the capacity of simulating temperature evolution within the prototype containing hybrid PCM, as well as to understand the contribution of hybrid PCM to energy efficiency. Incorporation of hybrid PCM into plastering mortars was found to have the potential to significantly reduce heating/cooling temperature demands for maintaining the interior temperature within comfort levels when compared to normal mortars (without PCM), or even mortars comprising a single type of PCM.
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Estudi elaborat a partir d’una estada a Çukurova University, Turquia, al juliol del 2006. L’emmagatzematge d’energia tèrmica ha atret interès en aplicacions tèrmiques com l’aigua calenta, la calefacció i l’aire condicionat. Aquests sistemes són útils per corregir la no coincidència entre la oferta i la demanda d’energia. Principalment hi ha dos tipus de sistemes d’emmagatzematge d’energia tèrmica, emmagatzematge amb calor sensible i amb calor latent. L’emmagatzematge amb calor latent és particularment atractiu degut a la seva habilitat de donar una densitat d’emmagatzematge d’energia més alt i la seva característica d’emmagatzemar calor a una temperatura constant corresponent a la temperatura de transició de fase de la substància emmagatzemadora de calor. Les salts hidratades orgàniques tenen certes avantatges com a materials d’emmagatzematge de calor latent sobre els materials orgànics. En canvi, quan les salts hidratades s’utilitzen com a materials de canvi de fase (PCM) apareixen alguns problemes en les aplicacions d’emmagatzematge de calor latent. Aquests són el subrefredament de les salts hidratades quan es congelen degut a les seves dèbils propietats de nucleació, i la separació de fase que hi apareix degut a una fusió incongruent. En aquest estudi, s’estabilitza sal de Glauber (Na2SO4.10H2O) amb diferents concentracions de poliacrilamida i gelatina per prevenir la fusió incongruent. Per prevenir el subrefredament s’utilitza un agent nucleant amb una estructura cristal•lina semblant a la de la sal de Glauber. La capacitat d’emmagatzematge de calor de les mostres de PCM estabilitzades amb diferents concentracions de gels polimèrics es determinen amb DCS i amb el mètode T-history.
Resumo:
En aquest treball es pretén estudiar el potencial d'emmagatzematge d'energia tèrmica, per aplicacions de refrigeració solar d'un sistema format per dos tancs intercanviadors acumuladors connectats en cascada. Cada tanc conté un PCM diferent amb diferent temperatura de canvi de fase. Concretament es tracta d'hidroquinona i d-mannitol. Els quals posseixen temperatures de canvi de fase entre 140 i 200 Cº requerides per aplicacions de fred solar. També es pretén comparar el sistema en cascada amb el mateix sistema connectat en paral·lel.
Resumo:
L'objectiu del projecte és el disseny d'una unitat d'emmagatzematge d'energia térmica que optimitzi i millori l'eficiència del sistema de climatització. Aquesta unitat contindrà materials de canvi de fase (PCM) per emmagatzemar l'energia i estarà acoblada a un sistema de climatització format per una bomba de calor i una unitat de tractament de l'aire.
Resumo:
Commercially available PCM RT 20, RT 27, SP 22, A17 and SP 25 A8. Were analyzed using dynamic and step method of heat flux DSC. The results of the dinamic and step method were compared with commercial valures. It was found that RT 20 & RT 27 showed good conforming of results with commercial values while SP 22 A17 & SP 25 A8 did not show conformity.
Resumo:
The aim of this work is to improve the thermal performance of commercial freezers using phase change materials (PCM) and the prove the importance of the correct PCM selection (melting temperature) for each application. To do this a vertical freezer with and without macro encapsulation PCM are used to assess the benefits of using PCM in minimizing temperature fluctuations and to maintain at the lowest possible temperature the freezer under heat of losses.
Utilisation de splines monotones afin de condenser des tables de mortalité dans un contexte bayésien
Resumo:
Dans ce mémoire, nous cherchons à modéliser des tables à deux entrées monotones en lignes et/ou en colonnes, pour une éventuelle application sur les tables de mortalité. Nous adoptons une approche bayésienne non paramétrique et représentons la forme fonctionnelle des données par splines bidimensionnelles. L’objectif consiste à condenser une table de mortalité, c’est-à-dire de réduire l’espace d’entreposage de la table en minimisant la perte d’information. De même, nous désirons étudier le temps nécessaire pour reconstituer la table. L’approximation doit conserver les mêmes propriétés que la table de référence, en particulier la monotonie des données. Nous travaillons avec une base de fonctions splines monotones afin d’imposer plus facilement la monotonie au modèle. En effet, la structure flexible des splines et leurs dérivées faciles à manipuler favorisent l’imposition de contraintes sur le modèle désiré. Après un rappel sur la modélisation unidimensionnelle de fonctions monotones, nous généralisons l’approche au cas bidimensionnel. Nous décrivons l’intégration des contraintes de monotonie dans le modèle a priori sous l’approche hiérarchique bayésienne. Ensuite, nous indiquons comment obtenir un estimateur a posteriori à l’aide des méthodes de Monte Carlo par chaînes de Markov. Finalement, nous étudions le comportement de notre estimateur en modélisant une table de la loi normale ainsi qu’une table t de distribution de Student. L’estimation de nos données d’intérêt, soit la table de mortalité, s’ensuit afin d’évaluer l’amélioration de leur accessibilité.