992 resultados para Osseointegrated dental implant


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of estrogen deficiency on bone around osseointegrated dental implants in a rat jaw model. Materials and Methods: This study used 16 female rats that had the first molars bilaterally extracted and were allowed to heal for 30 days before implant placement. Sixty days after implant placement, the animals were randomly subjected to sham surgery or ovariectomy (OVX). The animals were euthanized 90 days after OVX. Bone-to-implant contact, bone area fraction occupancy between implant threads, mineral density, turnover markers, and cells positive for tartrate-resistant acid phosphatase were assessed for the 2 groups. Results: The results showed that OVX group presented a decrease of systemic bone density, alterations in bone turnover markers, and an increase of cells positive for tartrate-resistant acid phosphatase compared with the sham-surgery group. However, no difference relative to bone-to-implant contact and bone area fraction occupancy was observed between groups. Conclusions: The findings of this study demonstrate that estrogen deficiency may not be considered a risk factor for osseointegrated implant failure in jaw bone. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69:1911-1918, 2011

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of the present study was to evaluate the influence of radiation in osseointegrated dental implants installed in tibiae of rats.Material and methods: Screw-shaped implants (2.5 mm diameter by 3.5 mm length) were custom made from commercially pure titanium bars. Titanium implants were blasted and sterilized before implantation. Animals were divided into two groups of 12 animals each and the rats were not paired after the groups' formation. The experimental group (group 1) received external irradiation 4 weeks after surgery while in the control group (group 2) animals were kept free of radiation. The shear strength required to detach the implant from bone was measured by push-out testing and osseointegration was histologically evaluated.Results: Results showed that the compressive strength of irradiated implants (33.49 MPa) was significantly lower than the compressive strength of non-irradiated implants (48.05 MPa).Conclusions: We concluded that the mechanical strength bonding between implants and host tissues decreased after irradiation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Total orbital exenteration is a radical surgical procedure, which typically involves the removal of the entire contents of the orbit including the periorbita, leaving the patient with a deep orbital deformity and results in devastating cosmetic, functional, and psychological consequences requiring difficult and challenging procedures for oculoplastic surgeons. Oculofacial prostheses retained by endosseous dental implants present an attractive and viable alternative when aesthetic and functional demands are beyond the capacity of local reconstructive efforts. PATIENTS AND METHODS: A 72-year-old woman presenting a malignant melanoma of the right eyelids and a 77-year-old man presenting a sebaceous carcinoma of the left upper eyelid underwent a total exenteration followed by positioning of endosseous implants (Straumann system Dental implants) as an integrated one-step combined surgical procedure. The oculofacial prosthesis was placed after epithelialization of the orbital cavity. RESULTS: The implants were perfectly osseointegrated without any complications, providing sufficient retention of the prostheses. A satisfactory aesthetic outcome has been achieved for both patients. CONCLUSIONS: Oculofacial prostheses anchored by osseointegrated dental implants placed as one-step surgical procedure ensure an adequate aesthetic result as well as a considerably decreased rehabilitation time and present a satisfactory solution when reconstruction is not a suitable option.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic rehabilitation involved, the number of abutments and pontics, the presence or absence of distal extensions or cantilevers, and loading time to fracture. Implant fracture was more common in males than in females (15:4), and the mean patient age was 56.9 years. Most cases (n = 19) corresponded to implant-supported fixed prostheses - 16 with cantilevers of different lengths- while only two fractured implants were supporting overdentures instead of fixed prostheses. The great majority of fractured implants (80.9%) were located in the molar and premolar regions, and most fractured within 3-4 years after loading. It is important to know and apply the measures required to prevent implant fracture, and to seek the best individualized solution for each case - though complete implant removal is usually the treatment of choice

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methods to optimize healing through dietary strategies present an attractive option for patients, such that healing from delicate oral surgeries occurs as optimally as possible with minimal patient-meditated complications through improper food choices. This review discusses findings from studies that have investigated the role of diet, either whole foods or individual dietary components, on periodontal health and their potential role in wound healing after periodontal surgery. To date, research in this area has largely focused on foods or individual dietary components that may attenuate inflammation or oxidant stress, or foster de novo bone formation. These studies suggest that a wide variety of dietary components, including macronutrients and micronutrients, are integral for optimal periodontal health and have the potential to accelerate oral wound healing after periodontal procedures. Moreover, this review provides guidance regarding dietary considerations that may help a patient achieve the best possible outcome after a periodontal procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated possible publication bias and its related factors in implant-related research over time. Materials and Methods: Articles published in Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, Implant Dentistry, Journal of Oral Implantology, and The International Journal of Oral & Maxillofacial Implants between 2005 and 2009 were reviewed. Nonoriginal articles were excluded. For each article included, study outcome, extramural funding source, type of study, and geographic origin were recorded. Descriptive and analytic statistics (alpha = .05), including the chi-square test and logistic regression analysis, were performed where appropriate. Results: From a total of 2,085 articles, 1,503 met the inclusion criteria. of the articles analyzed, 1,226 (81.6%), 160 (10.6%), and 117 (7.8%) articles reported positive, negative, and neutral outcomes, respectively. In vitro studies, studies from Asia, and funded animal studies were more likely to report positive outcomes compared to others (P = .02, P < .0001, and P = .009, respectively). Industry-funded studies represented the lowest frequency of positive outcomes versus studies funded by other sources. Conclusions: There were a high number of implant-related studies reporting positive outcomes in the five selected journals. Some selected factors were associated with positive outcome bias. In general, funding was not associated with a positive outcome, except for animal studies. Industry-supported research did not show any association with the publication of positive outcomes. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:1024-1032

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To survey the current radiographic prescriptions in dental implant assessment amongst dentists in Brazil.Methods: Sixty-nine dentists were interviewed during a dental implant meeting by two calibrated graduate students, using a 19-question questionnaire, considering imaging modality options both for pre-operative implant site assessment and for follow-up, particularly with respect to cost, patient radiation dose, and broad coverage of facial bones and teeth. Epi-Info 6.04 software was used to analyse the database file.Results: Approximately 63.8% of the dentists prescribed only panoramic radiography for dental implant assessment and 28.9% ordered panoramic radiography plus periapical radiography and/or conventional tomography and/or computed tomography (CT). Only 7.2% of the dentists ordered conventional tomography or CT as a single examination, although 10.1% ordered it in combination with other imaging modalities. The main reasons given for prescribing panoramic radiography were broad coverage and cost (86.4%).Conclusions: This study has shown that most of the dentists in this study prescribe panoramic radiographs in dental implant assessment based on broad coverage and cost. They are not following the American Academy of Oral and Maxillofacial Radiology recommendations regarding cross-sectional imaging.