96 resultados para Oscilaciones


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias en Ingeniería Eléctrica con Especialidad en Potencia) UANL

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis ( Maestro en Ciencias de la Administración con Especialidad en Sistemas) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis ( Maestro en Ciencias de la Ingeniería Eléctrica con Especialidad en Potencia) - U.A.N.L., 2002

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias de la Ingeniería Eléctrica con Orientación en Sistemas Eléctricos de Potencia) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias de la Ingeniería Eléctrica con Orientación en Sistemas Eléctricos de Potencia) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Doctor en Ingeniería Eléctrica) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interpretación geométrica del fenómeno de las oscilaciones eléctricas que nos ha permitido deducir la fórmula de Thomson. Energéticamente las oscilaciones de un circuito oscilante se realizan en virtud de un intercambio constante entre las dos clases de energía implicadas, la del campo eléctrico y la del campo magnético. El principio de conservación de la energía permite establecer que en todo momento permanece constante la suma de dichas energías.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES] En Canarias están las pruebas de la existencia de una cadena climática en esta parte del Globo: eslabones de clima de pleno glacial árido-frío (dunas), de clima interglacial temprano árido-sub-húmedo (polvo), de clima cálido y húmedo de máximo interglacial (depósitos marinos), de clima de transición árido-templado (calcretas) y otra vez clima glacial-árido-frio. Esta cadena se desarrolla desde hace cinco millones de años inicialmente en adagio (lento y majestuoso) para pasar sucesivamente a un andante, allegro y vivace. Este largo proceso está medido desde 1981 hasta este año de 2013 por todas las dataciones existentes: K/Ar en lavas, U/Th en fósiles marinos y terrestres, C14 tradicional y en acelerador atómico en fósiles, OSL en dunas, Series de U en corales, además de ensayos sobre aminoácidos e isótopos de Sr en marcha. Todo ello con una espléndida y sorprendente información paleontológica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La artroplastia de cadera se considera uno de los mayores avances quirúrgicos de la Medicina. La aplicación de esta técnica de Traumatología se ha incrementado notablemente en los últimos anos, a causa principalmente del progresivo incremento de la esperanza de vida. En efecto, con la edad aumentan los problemas de artrosis y osteoporosis, enfermedades típicas de las articulaciones y de los huesos que requieren en muchos casos la sustitución protésica total o parcial de la articulación. El buen comportamiento funcional de una prótesis depende en gran medida de la estabilidad primaria, es decir, el correcto anclaje de la prótesis en el momento de su implantación. Las prótesis no cementadas basan su éxito a largo plazo en la osteointegración que tiene lugar entre el material protésico y el tejido óseo, y para lograrla es imprescindible conseguir unas buenas condiciones de estabilidad primaria. El aflojamiento aséptico es la principal causa de fallo de artroplastia total de cadera. Este es un fenómeno en el que, debido a complejas interacciones de factores mecánicos y biológicos, se producen movimientos relativos que comprometen la funcionalidad del implante. La minimización de los correspondientes danos depende en gran medida de la detección precoz del aflojamiento. Para lograr la detección temprana del aflojamiento aséptico del vástago femoral se han ensayado diferentes técnicas, tanto in vivo como in vitro: análisis numéricos y técnicas experimentales basadas en sensores de movimientos provocados por cargas transmitidas natural o artificialmente, tales como impactos o vibraciones de distintas frecuencias. Los montajes y procedimientos aplicados son heterogéneos y, en muchas ocasiones, complejos y costosos, no existiendo acuerdo sobre una técnica simple y eficaz de aplicación general. Asimismo, en la normativa vigente que regula las condiciones que debe cumplir una prótesis previamente a su comercialización, no hay ningún apartado referido específicamente a la evaluación de la bondad del diseño del vástago femoral con respecto a la estabilidad primaria. El objetivo de esta tesis es desarrollar una metodología para el análisis, in vitro, de la estabilidad de un vástago femoral implantado, a fin de poder evaluar las técnicas de implantación y los diferentes diseños de prótesis previamente a su oferta en el mercado. Además se plantea como requisito fundamental que el método desarrollado sea sencillo, reversible, repetible, no destructivo, con control riguroso de parámetros (condiciones de contorno de cargas y desplazamientos) y con un sistema de registro e interpretación de resultados rápido, fiable y asequible. Como paso previo, se ha realizado un análisis cualitativo del problema de contacto en la interfaz hueso-vástago aplicando una técnica optomecánica del campo continuo (fotoelasticidad). Para ello se han fabricado tres modelos en 2D del conjunto hueso-vástago, simulando tres tipos de contactos en la interfaz: contacto sin adherencia y con holgura, contacto sin adherencia y sin holgura, y contacto con adherencia y homogéneo. Aplicando la misma carga a cada modelo, y empleando la técnica de congelación de tensiones, se han visualizado los correspondientes estados tensionales, siendo estos más severos en el modelo de unión sin adherencia, como cabía esperar. En todo caso, los resultados son ilustrativos de la complejidad del problema de contacto y confirman la conveniencia y necesidad de la vía experimental para el estudio del problema. Seguidamente se ha planteado un ensayo dinámico de oscilaciones libres con instrumentación de sensores resistivos tipo galga extensométrica. Las muestras de ensayo han sido huesos fémur en todas sus posibles variantes: modelos simplificados, hueso sintético normalizado y hueso de cadáver, seco y fresco. Se ha diseñado un sistema de empotramiento del extremo distal de la muestra (fémur) con control riguroso de las condiciones de anclaje. La oscilación libre de la muestra se ha obtenido mediante la liberación instantánea de una carga estética determinada y aplicada previamente, bien con una maquina de ensayo o bien por gravedad. Cada muestra se ha instrumentado con galgas extensométricas convencionales cuya señal se ha registrado con un equipo dinámico comercial. Se ha aplicado un procedimiento de tratamiento de señal para acotar, filtrar y presentar las respuestas de los sensores en el dominio del tiempo y de la frecuencia. La interpretación de resultados es de tipo comparativo: se aplica el ensayo a una muestra de fémur Intacto que se toma de referencia, y a continuación se repite el ensayo sobre la misma muestra con una prótesis implantada; la comparación de resultados permite establecer conclusiones inmediatas sobre los efectos de la implantación de la prótesis. La implantación ha sido realizada por un cirujano traumatólogo utilizando las mismas técnicas e instrumental empleadas en el quirófano durante la práctica clínica real, y se ha trabajado con tres vástagos femorales comerciales. Con los resultados en el dominio del tiempo y de la frecuencia de las distintas aplicaciones se han establecido conclusiones sobre los siguientes aspectos: Viabilidad de los distintos tipos de muestras sintéticas: modelos simplificados y fémur sintético normalizado. Repetibilidad, linealidad y reversibilidad del ensayo. Congruencia de resultados con los valores teóricos deducidos de la teoría de oscilaciones libres de barras. Efectos de la implantación de tallos femorales en la amplitud de las oscilaciones, amortiguamiento y frecuencias de oscilación. Detección de armónicos asociados a la micromovilidad. La metodología se ha demostrado apta para ser incorporada a la normativa de prótesis, es de aplicación universal y abre vías para el análisis de la detección y caracterización de la micromovilidad de una prótesis frente a las cargas de servicio. ABSTRACT Total hip arthroplasty is considered as one of the greatest surgical advances in medicine. The application of this technique on Traumatology has increased significantly in recent years, mainly due to the progressive increase in life expectancy. In fact, advanced age increases osteoarthritis and osteoporosis problems, which are typical diseases of joints and bones, and in many cases require full or partial prosthetic replacement on the joint. Right functional behavior of prosthesis is highly dependent on the primary stability; this means it depends on the correct anchoring of the prosthesis at the time of implantation. Uncemented prosthesis base their long-term success on the quality of osseointegration that takes place between the prosthetic material and bone tissue, and to achieve this good primary stability conditions is mandatory. Aseptic loosening is the main cause of failure in total hip arthroplasty. This is a phenomenon in which relative movements occur, due to complex interactions of mechanical and biological factors, and these micromovements put the implant functionality at risk. To minimize possible damage, it greatly depends on the early detection of loosening. For this purpose, various techniques have been tested both in vivo and in vitro: numerical analysis and experimental techniques based on sensors for movements caused by naturally or artificially transmitted loads, such as impacts or vibrations at different frequencies. The assemblies and methods applied are heterogeneous and, in many cases, they are complex and expensive, with no agreement on the use of a simple and effective technique for general purposes. Likewise, in current regulations for governing the conditions to be fulfilled by the prosthesis before going to market, there is no specific section related to the evaluation of the femoral stem design in relation to primary stability. The aim of this thesis is to develop a in vitro methodology for analyzing the stability of an implanted femoral stem, in order to assess the implantation techniques and the different prosthesis designs prior to its offer in the market. We also propose as a fundamental requirement that the developed testing method should be simple, reversible, repeatable, non-destructive, with close monitoring of parameters (boundary conditions of loads and displacements) and with the availability of a register system to record and interpret results in a fast, reliable and affordable manner. As a preliminary step, we have performed a qualitative analysis of the contact problems in the bone-stem interface, through the application of a continuous field optomechanical technique (photoelasticity). For this proposal three 2D models of bone–stem set, has been built simulating three interface contact types: loosened an unbounded contact, unbounded and fixed contact, and bounded homogeneous contact. By means of applying the same load to each model, and using the stress freezing technique, it has displayed the corresponding stress states, being more severe as expected, in the unbounded union model. In any case, the results clearly show the complexity of the interface contact problem, and they confirm the need for experimental studies about this problem. Afterward a free oscillation dynamic test has been done using resistive strain gauge sensors. Test samples have been femur bones in all possible variants: simplified models, standardized synthetic bone, and dry and cool cadaveric bones. An embedding system at the distal end of the sample with strong control of the anchoring conditions has been designed. The free oscillation of the sample has been obtained by the instantaneous release of a static load, which was previously determined and applied to the sample through a testing machine or using the gravity force. Each sample was equipped with conventional strain gauges whose signal is registered with a marketed dynamic equipment. Then, it has applied a signal processing procedure to delimit, filter and present the time and frequency response signals from the sensors. Results are interpreted by comparing different trials: the test is applied to an intact femur sample which is taken as a reference, and then this test is repeated over the same sample with an implanted prosthesis. From comparison between results, immediate conclusions about the effects of the implantation of the prosthesis can be obtained. It must be said that the implementation has been made by an expert orthopedic surgeon using the same techniques and instruments as those used in clinical surgery. He has worked with three commercial femoral stems. From the results obtained in the time and frequency domains for the different applications the following conclusions have been established: Feasibility of the different types of synthetic samples: simplified models and standardized synthetic femur. Repeatability, linearity and reversibility of the testing method. Consistency of results with theoretical values deduced from the bars free oscillations theory. Effects of introduction of femoral stems in the amplitude, damping and frequencies of oscillations Detection of micromobility associated harmonics. This methodology has been proved suitable to be included in the standardization process of arthroplasty prosthesis, it is universally applicable and it allows establishing new methods for the analysis, detection and characterization of prosthesis micromobility due to functional loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desde el descubrimiento de los ritmos ultradianos (Halberg 1967) en el estudio de las etapas de sueño humano (Dement y Kleitman, 1957) , muchos investigadores han dado cuenta de la existencia de estas oscilaciones en varias funciones de conducta, emocionales o fisiológicas. Si anteriormente predominó la idea de que los ritmos ultradianos tenían lugar únicamente durante el sueño, el descubrimiento de las oscilaciones en estado insomne (Weltzman et al, 1.970) y su persistencia en diferentes funciones bajo el efecto de inhibición de la droga (estados REM, Baekeland, 1967), han demostrado que persiste el mismo ciclo en el sueño que en estado insomne (Kleitman, 1969) que conduce y controla simultáneamente diferentes parámetros biológicos. Basado en este principio y a partir de nuestras estimaciones estadísticas de oscilaciones en el rango de 70-250 minutos de periodo en la actividad locomotora de diferentes especies; un mecanismo básico de desencadenamiento de los ritmos ultradianos por sincronizantes externos y su sincronización coherente con las oscilaciones circadianas (a través de acoplamientos mutuos o jerárquicos); presentamos un modelo matemático que simula el sistema oscilatorio de comportamiento ultradiano-circadiano producido por una secuencia bien definida luz-oscuridad. El modelo se basa en una topología de círculo límite (representada en un espacio bidimensional de estados) con control paramétrico producido por las transiciones luz—oscuridad y viceversa, siendo el efecto paramétrico dependiente de la fase endógena del sistema cuando se aplica las transiciones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta memoria recoge los resultados de los estudios estratigráficos, geoquímicos de alta resolución e histórico-arqueológicos del registro Pleistoceno superior-Holoceno de las llanuras costeras de Castellón de la Plana y Sagunto. Se ha reconstruido la arquitectura estratigráfica de ambas llanuras, lo que nos ha permitido determinar los principales factores que condicionaron su relleno. El principal es la posición relativa del nivel del mar que, a su vez, depende de varias causas o forzamientos que actúan en diferentes escalas de tiempo. Determinar las variaciones relativas del nivel del mar y su origen en un periodo próximo al que vivimos puede ayudarnos a saber cómo evolucionaran los sistemas sedimentarios costeros en el futuro. Por ello es necesario analizar un gran número de zonas, ambientes sedimentarios y procesos para mejorar la precisión. En este caso, se ha estudiado todo el ámbito litoral pero haciendo hincapié en tres lagunas costeras de agua dulce (Almenara, Nules y Benicasim)...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Programa de doctorado: Praxiología motriz, educación física y entrenamiento deportivo. La fecha de publicación es la fecha de lectura

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El principal objetivo de este trabajo es la reducción del retraso y de la complejidad computacional en las estimaciones fasoriales, calculadas bajo oscilaciones del sistema de potencia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El fasor ha sido considerando como un concepto esencialmente de estado estable desde su invención por lo que hasta ahora la mayoría de las algoritmos de estimación fasorial están conformados así.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El café (Coffea arabica .) es componente importante del paisaje y de la economía nacional. El manejo agronomómico influye en la ecofisiología y calidad del café; por tal razón son de suma 1mportanc1a estudios e mvestigaciones para evaluar los efectos de diferentes Sistemas del cafeto asociados o no con árboles de sombra. El presente estudio se realizó, principalmente, en la Finca "San Francisco" de Inversiones Generales S.A., ubicada al Km 39 Y, de la carretera San Marcos- Las Esquinas, en el Departamento de Carazo, en un periodo comprendido entre el junio 2002 y el diciembre 2004. El objetivo general del estudio fue evaluar el comportamiento de las estructuras de crecimiento, productiva, rendimiento, contenido de biomasa seca, acumulación de nitrógeno y calidad fis1ca y organolépt1ca del café (Coffea arabica L. cv. Costa Rica 95) bajo tres diferentes tipologías de manejo agronómico: a) café con sombra y fertilización (CSF), b) café a pleno sol con fertilización (CSoIF) y c) café bajo sombra sin fertilización química (CS). En cada parcela se seleccionaron 8 plantas a las cuales se les tomaron los datos de altura, diámetro, proyección de copa, nudos totales en tallo principal, número de ramas primarias, secundarias y terciarias tanto totales como productivas de la planta y rendimiento de café oro por parcela. Una muestra por tratamiento de café oro en las cosechas fue tomada y enviada a CERCAFENIC de UNICAFE en Managua para determinar los aspectos físicos y organolépticos de los granos. Empleando el método destructivo se midió la biomasa y cantidad de nitrógeno acumulado en la raíz, tallo, ramas, hojas y frutos. Para mejorar y fortalecer el trabajo de investigación se hizo una comparación de calidad, del último ciclo cafetalero, con otros sistemas de manejo, usados sobre todo en dos Departamento del Norte del País, Matagalpa e Jinotega. En el caso de Matagalpa se evaluaron los datos físicos del grano y los dictámenes de taza de tres sistemas (Coffea arabica L. cv. Catimor y Caturro), a) café orgánico, b) café convencional, e) café de bajo insumo, aplicados en la "Cooperativa la Solidaridad", ubicada en la Cuenca del Aranjuez. Asimismo para Jinotega se sacaron las mismas variables del cafeto de bajo insumo de la "Cooperativa Santa Maria de Pantasma". Se estructuró un primero análisis de los costos de mantenimiento de los sistemas evaluado, obteniendo como resultado los costos y la ganancia por hectárea y el costo por kilogramo de café oro producido. El café con sombra y fertilizante presentó el mayor crecimiento en altura, proyección de copa, número de ramas primarias y secundarias totales y productivas. El café a puro sol obtuvo el mayor diámetro, el número de ramas terciarias, pero también la mayor cantidad de ramas agotadas o muertas. A las variables de biomasa y nitrógeno se aplicó un test "t de Student" por el programa estadístico SAS; solamente en los últimos meses de muestreo (junio, septiembre y diciembre 2004) se encontraron diferencias significativa entre los dos tratamientos abonados y el sistemas bajo sombra sin fertilizante. Los rendimientos fueron por dos veces mayores en el caso del sistema a puro sol. Las calidades sea fisicas que organolépticas mejoraron en el curso del estudio logrando en el último ciclo cafetalero la misma clasificación de los café de Matagalpa e Jinotega, taza OK, café lavado Matagalpa/Jinotega; pero los cafetos orgánico y de bajo insumo tuvieron resultados más satisfactorio. El café orgánico presentó los precios más alto y homogéneo en el curso de los tres años analizado, por eso, conjunto con el manejo convencional de la Finca "San Francisco", es lo que tuvo menores oscilaciones. Entre la tres parcelas experimentales los sistemas a pleno sol con fertilización (CSoiF) y el con sola sombra sin aporte de fertilizantes químicos (CS) son los que obtuvieron las mayores ganancia, saliendo de un primer año con resultados negativos o de poco más de 50 dólares por hectárea