935 resultados para Orthodontic treatment planning


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Submitted in partial fulfillment of the requirements for a Certificate in Orthodontics, Dept. of Orthodontics, University of Connecticut Health Center, 1975.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: a Ortodontia passa, atualmente, por um momento de importantes inovações e grande efervescência criativa. Somente para citar algumas mudanças introduzidas ou aprimoradas nos últimos anos, nós podemos relembrar a popularização dos braquetes autoligáveis e o surgimento da ancoragem absoluta com a utilização de implantes ortodônticos. No final da década de 1990, a adoção dos mini-implantes como ancoragem permitiu uma mudança de paradigma que tem influenciado até mesmo a forma de pensar a mecânica ortodôntica. A imbricação das especialidades de Ortodontia e Implantodontia, cujo início se deu com os preparos ortodônticos para posterior inserção de implantes protéticos, floresceu com o uso de implantes palatinos e, posteriormente, com a introdução de mini-implantes. O aprimoramento da técnica de inserção de mini-implantes com a introdução de parafusos autoperfurantes tem permitido, inclusive, o requinte do ortodontista concentrar em suas mãos o planejamento e a colocação dessa preciosa peça de ancoragem. Levando em consideração a versatilidade de posicionamento desses pequenos parafusos, foi desenvolvido um conceito que possibilita a construção de linhas de ação de força que buscam otimizar o planejamento e a previsibilidade da movimentação ortodôntica. OBJETIVO: apresentar alguns resultados clínicos de tratamentos conduzidos com o uso de um sistema de tratamento ortodôntico, o Centrex System, que aproxima a linha de ação da força do centro de resistência das unidades a serem movimentadas. O caminho trilhado até o seu desenvolvimento, cuja teoria mecânica foi apresentada anteriormente nesse periódico, será detalhado para uma melhor compreensão de seu funcionamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Apical root resorption is a frequent and occasionally critical problem in orthodontic patients undergoing induced tooth movement. One of the factors that might influence prognosis, especially in maxillary incisors, which most frequently present resorptions, are the so-called the anatomical barriers; that is, proximity of the buccal and palatal cortical bones to the maxillary incisor roots. OBJECTIVE: The purpose of this research was to investigate whether patients with excessive vertical growth really present a small distance between the alveolar cortical bones and the maxillary incisor roots, and whether there is a correlation between this distance and the root resorption index in comparison with patients presenting horizontal growth. METHODS: The sample comprised orthodontic records of 18 patients with extraction planning of first maxillary premolars and treatment by the standard and/or preadjusted edgewise brackets. Their initial and final periapical radiographs were evaluated to determine the amount of root resorption that occurred. RESULTS: On the palatal side, patients with excessive vertical growth (Group 2 - SN-GoGn > 43º) showed a narrower alveolar bone than the horizontal growth patients (Group 1 - SN-GoGn < 29º). However, the distance between the buccal cortical bone and the central incisor root apex showed no significant difference between Groups 1 and 2; CONCLUSIONS: It was concluded that there are no correlations between the proximity of buccal cortical bone, maxillary incisor roots and the root resorption index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction This study investigated the sensitivity of calculated stereotactic radiotherapy and radiosurgery doses to the accuracy of the beam data used by the treatment planning system. Methods Two sets of field output factors were acquired using fields smaller than approximately 1 cm2, for inclusion in beam data used by the iPlan treatment planning system (Brainlab, Feldkirchen, Germany). One set of output factors were measured using an Exradin A16 ion chamber (Standard Imaging, Middleton, USA). Although this chamber has a relatively small collecting volume (0.007 cm3), measurements made in small fields using this chamber are subject to the effects of volume averaging, electronic disequilibrium and chamber perturbations. The second, more accurate, set of measurements were obtained by applying perturbation correction factors, calculated using Monte Carlo simulations according to a method recommended by Cranmer-Sargison et al. [1] to measurements made using a 60017 unshielded electron diode (PTW, Freiburg, Germany). A series of 12 sample patient treatments were used to investigate the effects of beam data accuracy on resulting planned dose. These treatments, which involved 135 fields, were planned for delivery via static conformal arcs and 3DCRT techniques, to targets ranging from prostates (up to 8 cm across) to meningiomas (usually more than 2 cm across) to arterioveinous malformations, acoustic neuromas and brain metastases (often less than 2 cm across). Isocentre doses were calculated for all of these fields using iPlan, and the results of using the two different sets of beam data were evaluated. Results While the isocentre doses for many fields are identical (difference = 0.0 %), there is a general trend for the doses calculated using the data obtained from corrected diode measurements to exceed the doses calculated using the less-accurate Exradin ion chamber measurements (difference\0.0 %). There are several alarming outliers (circled in the Fig. 1) where doses differ by more than 3 %, in beams from sample treatments planned for volumes up to 2 cm across. Discussion and conclusions These results demonstrate that treatment planning dose calculations for SRT/SRS treatments can be substantially affected when beam data for fields smaller than approximately 1 cm2 are measured inaccurately, even when treatment volumes are up to 2 cm across.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim The assessment of treatment plans is an important component in the education of radiation therapists. The establishment of a grade for a plan is currently based on subjective assessment of a range of criteria. The automation of assessment could provide a number of advantages including faster feedback, reduced chance of human error, and simpler aggregation of past results. Method A collection of treatments planned by a cohort of 27 second year radiation therapy students were selected for quantitative evaluation. Treatment sites included the bladder, cervix, larynx, parotid and prostate, although only the larynx plans had been assessed in detail. The plans were designed with the Pinnacle system and exported using the DICOM framework. Assessment criteria included beam arrangement optimisation, volume contouring, target dose coverage and homogeneity, and organ-at-risk sparing. The in-house Treatment and Dose Assessor (TADA) software1 was evaluated for suitability in assisting with the quantitative assessment of these plans. Dose volume data were exported in per-student and per-structure data tables, along with beam complexity metrics, dose volume histograms, and reports on naming conventions. Results The treatment plans were exported and processed using TADA, with the processing of all 27 plans for each treatment site taking less than two minutes. Naming conventions were successfully checked against a reference protocol. Significant variations between student plans were found. Correlation with assessment feedback was established for the larynx plans. Conclusion The data generated could be used to inform the selection of future assessment criteria, monitor student development, and provide useful feedback to the students. The provision of objective, quantitative evaluations of plan quality would be a valuable addition to not only radiotherapy education programmes but also for staff development and potentially credentialing methods. New functionality within TADA developed for this work could be applied clinically to, for example, evaluate protocol compliance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a novel approach to treatment planning for focal brachytherapy utilizing a biologically based inverse optimization algorithm and biological imaging to target an ablative dose at known regions of significant tumour burden and a lower, therapeutic dose to low risk regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

中国科学院近代物理研究所基于兰州重离子研究装置(HIRFL/HIRFL-CSR),在被动型束流配送系统下采用二维分层适形照射治疗技术开展重离子治癌临床试验研究。为了更好地利用重离子束在肿瘤放射治疗中的生物物理优势并保障重离子临床治疗试验的顺利实施,一个初级版本的重离子治疗计划系统已经设计完成。此计划系统是针对被动型束流配送系统下的二维分层适形照射治疗方式来进行设计的。介绍了此系统的设计框架、可提供的功能以及利用宽束算法进行剂量计算在此系统中的实现。通过人体仿真体模实验证实由该治疗计划系统给出的靶区计划剂量与实测剂量的偏差在5%之内。最后讨论了设计较为完备的重离子治疗计划系统仍需解决的问题。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To demonstrate the feasibility of using a knowledge base of prior treatment plans to generate new prostate intensity modulated radiation therapy (IMRT) plans. Each new case would be matched against others in the knowledge base. Once the best match is identified, that clinically approved plan is used to generate the new plan. METHODS: A database of 100 prostate IMRT treatment plans was assembled into an information-theoretic system. An algorithm based on mutual information was implemented to identify similar patient cases by matching 2D beam's eye view projections of contours. Ten randomly selected query cases were each matched with the most similar case from the database of prior clinically approved plans. Treatment parameters from the matched case were used to develop new treatment plans. A comparison of the differences in the dose-volume histograms between the new and the original treatment plans were analyzed. RESULTS: On average, the new knowledge-based plan is capable of achieving very comparable planning target volume coverage as the original plan, to within 2% as evaluated for D98, D95, and D1. Similarly, the dose to the rectum and dose to the bladder are also comparable to the original plan. For the rectum, the mean and standard deviation of the dose percentage differences for D20, D30, and D50 are 1.8% +/- 8.5%, -2.5% +/- 13.9%, and -13.9% +/- 23.6%, respectively. For the bladder, the mean and standard deviation of the dose percentage differences for D20, D30, and D50 are -5.9% +/- 10.8%, -12.2% +/- 14.6%, and -24.9% +/- 21.2%, respectively. A negative percentage difference indicates that the new plan has greater dose sparing as compared to the original plan. CONCLUSIONS: The authors demonstrate a knowledge-based approach of using prior clinically approved treatment plans to generate clinically acceptable treatment plans of high quality. This semiautomated approach has the potential to improve the efficiency of the treatment planning process while ensuring that high quality plans are developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The acquisition of radiotherapy planning scans on positron emission tomography (PET)-CT scanners requires the involvement of radiotherapy radiographers. This study assessed the radiation dose received by these radiographers during this process. Radiotherapy planning F- fluorodeoxyglucose (F-FDG) PET-CT scans were acquired for 28 non-small cell lung cancer patients. In order to minimise the radiation dose received, a two-stage process was used in which the most time-consuming part of the set-up was performed before the patient received their F-FDG injection. Throughout this process, the radiographers wore electronic personal dosemeters and recorded the doses received at different stages of the process. The mean total radiation dose received by a radiotherapy radiographer was 5.1±2.6 mSv per patient. The use of the two-stage process reduced the time spent in close proximity to the patient by approximately a factor of four. The two-stage process was effective in keeping radiation dose to a minimum. The use of a pre-injection set-up session reduces the radiation dose to the radiotherapy radiographers because of their involvement in PET-CT radiotherapy treatment planning scans by approximately a factor of three.