25 resultados para Optometrist
Resumo:
Mode of access: Internet.
Resumo:
Acute posterior vitreous detachment (PVD) is the most common cause of retinal detachment. The management of this condition can be variable and often undue reliance is placed upon associated signs and symptoms which can be a poor indicator of pathology. Optometrists undertake a number of extended roles, however involvement in vitreo-retinal sub-specialities appears to be limited. One objective was to directly compare an optometrist and ophthalmologist in the assessment of patients with PVD, for this a high level of agreement was found (95% sensitivity, 99% specificity, 0.94 kappa). A review of 1107 patients diagnosed with acute PVD that were re-evaluated in a PVD clinic a few weeks later was undertaken to determine whether such reviews are necessary. One-fifth of patients were found to have conditions undiagnosed at the initial assessment, overall 4% of patients had retinal breaks when examined in the PVD clinic and a total of 7% required further intervention. The sensitivity of fundus examination with +90D and 3-mirror lenses was 85-88% for detecting retinal breaks and 7-85% for pigment in the anterior vitreous for the presence of retinal breaks. Therefore patients with acute PVD should be examined by indirect ophthalmoscopy with indentation at the onset of PVD and 4-6 weeks later. The treatment of retinal breaks with laser retinopexy is performed by ophthalmologists with a primary success rate 54-85%. In a pioneering development, an optometrist undertaking this role achieved a comparable primary success rate (79%). Mid-vitreous opacities associated with PVD are described, and noted in 100% of eyes with PVD. The recognition of this sign is important in the diagnosis of PVD and retinal breaks. The importance of diagnostic imaging is also demonstrated, however the timing in relation to onset may be vital.
Resumo:
Relatório de atividade profissional de mestrado em Optometria Avançada
Resumo:
Relatório de atividade profissional de mestrado em Optometria Avançada
Resumo:
Relatório de atividade profissional de mestrado em Optometria Avançada
Resumo:
Diabetes is a common condition affecting around 69,000 people in Northern Ireland. One of the possible complications of diabetes is a condition called diabetic retinopathy, which can cause sight loss and blindness. Retinopathy causes damage to the tiny blood vessels (capillaries) that nourish the retina, the tissues in the back of the eye that deal with light. This can seriously affect vision.Research shows that if retinopathy is identified early, for example through retinal screening, and treated appropriately, blindness can be prevented in the majority of people with diabetes, both type 1 and type 2.Screening programmeIn Northern Ireland, a diabetic retinopathy screening programme (DRSP), run by the Public Health Agency, has been put in place to screen all eligible people with diabetes aged 12 years and over. Dr Bernadette Cullen, Consultant in Public Health Medicine, PHA, said: "Screening detects problems early and allows appropriate treatment to be offered. It is vital that everyone with diabetes attends diabetic retinopathy screening when it is offered. Early detection of potential problems offers a very real opportunity to intervene and, with appropriate treatment, can prevent blindness in the majority of those at risk."The screening testThe screening test involves photographs being taken of the back of each eye, using a special camera. The test is painless and takes about 15 minutes. If the person is over 50 years of age, they will need to have drops put in their eyes about 15 minutes before the test to dilate their pupils.The photographs are sent to the regional screening centre for analysis by trained graders. Results will show whether patients require further referral for assessment or treatment by hospital eye services (HES). If this is not required, screening will be offered again the following year.GPs are informed of all results and if the patient is under the care of a diabetologist, they too will be informed. Patients are informed of results by their GP and if they need an urgent referral, protocols are in place to ensure this happens.Many people with diabetes attend their optometrist (optician) on a regular basis to have a sight test for glasses. It is important they continue to do this - this test is free to people with diabetes. It is also vital that people with diabetes attend for diabetic retinopathy screening when invited, regardless of how or where their diabetes is treated, or whether they visit a hospital consultant/GP for their diabetic care.Patients are invited to screening via their GP practice. An information leaflet to help patients make an informed decision to attend for screening is also sent. This can be accessed via the PHA website: www.publichealth.hscni.net.
Resumo:
Máster en Ingeniería Informática. Escuela de Ingeniería Informática
Resumo:
Purpose. A clinical evaluation of the Shin-Nippon NVision-K 5001 (also branded as the Grand Seiko WR-5100K) autorefractor (Japan) was performed to examine validity and repeatability compared with subjective refraction and Javal-Schiotz keratometry. Methods. Measurements of refractive error were performed on 198 eyes of 99 subjects (aged 23.2 ± 7.4 years) subjectively (noncycloplegic) by one masked optometrist and objectively with the NVision-K autorefractor by a second optometrist. Keratometry measurements using the NVision-K were compared with the Javal-Schiotz keratometer. Intrasession repeatability of the NVision-K was also assessed on all 99 subjects together with intersession repeatability on a separate occasion separated by 7 to 14 days. Results. Refractive error as measured by the NVision-K was found to be similar (p = 0.67) to subjective refraction (difference, 0.14 ± 0.35 D). It was both accurate and repeatable over a wide prescription range (-8.25 to +7.25 D). Keratometry as measured by the NVision-K was found to be similar (p > 0.50) to the Javal-Schiotz technique in both the horizontal and vertical meridians (horizontal: difference, 0.02 ± 0.09 mm; vertical: difference, 0.01 ± 0.14 mm). There was minimal bias, and the results were repeatable (horizontal: intersession difference, 0.00 ± 0.09 mm; vertical: intersession difference, -0.01 ± 0.12 mm). Conclusion. The open-view arrangement of the Shin-Nippon NVision-K 5001 facilitates the measurement of static refractive error and the accommodative response to real-world stimuli. Coupled with its accuracy, repeatability, and capability to measure corneal curvature, it is a valuable addition to objective instrumentation currently available to the optometrist and researcher.
Resumo:
Purpose: A clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500 (Japan) was performed to evaluate validity and repeatability compared with non-cycloplegic subjective refraction and Javal–Schiotz keratometry. An investigation into the dynamic recording capabilities of the instrument was also conducted. Methods: Refractive error measurements were obtained from 150 eyes of 75 subjects (aged 25.12 ± 9.03 years), subjectively by a masked optometrist, and objectively with the WAM-5500 at a second session. Keratometry measurements from the WAM-5500 were compared to Javal–Schiotz readings. Intratest variability was examined on all subjects, whilst intertest variability was assessed on a subgroup of 44 eyes 7–14 days after the initial objective measures. The accuracy of the dynamic recording mode of the instrument and its tolerance to longitudinal movement was evaluated using a model eye. An additional evaluation of the dynamic mode was performed using a human eye in relaxed and accommodated states. Results: Refractive error determined by the WAM-5500 was found to be very similar (p = 0.77) to subjective refraction (difference, -0.01 ± 0.38 D). The instrument was accurate and reliable over a wide range of refractive errors (-6.38 to +4.88 D). WAM-5500 keratometry values were steeper by approximately 0.05 mm in both the vertical and horizontal meridians. High intertest repeatability was demonstrated for all parameters measured: for sphere, cylinder power and MSE, over 90% of retest values fell within ±0.50 D of initial testing. In dynamic (high-speed) mode, the root-mean-square of the fluctuations was 0.005 ± 0.0005 D and a high level of recording accuracy was maintained when the measurement ring was significantly blurred by longitudinal movement of the instrument head. Conclusion: The WAM-5500 Auto Ref/Keratometer represents a reliable and valid objective refraction tool for general optometric practice, with important additional features allowing pupil size determination and easy conversion into high-speed mode, increasing its usefulness post-surgically following accommodating intra-ocular lens implantation, and as a research tool in the study of accommodation.
Resumo:
As a result of the increasing proportion of elderly people in the UK population, it is likely that the optometrist will see patients with dementia in the practice. These patients pose particular problems for the optometrist who has to carry out refraction or an eye examination. Since each case of dementia is unique, it is impossible to give guidelines which will ensure the cooperation of all patients. However, a knowledge of the changes in personality shown by patients and the special problems that can arise is helpful in attempting to test the demented patient.
Resumo:
Dementia, including Alzheimer’s disease (AD), is a major disorder causing visual problems in the elderly population. The pathology of AD includes the deposition in the brain of abnormal aggregates of ß-amyloid (Aß) in the form of senile plaques (SP) and abnormally phosphorylated tau in the form of neurofibrillary tangles (NFT). A variety of visual problems have been reported in patients with AD including loss of visual acuity (VA), colour vision and visual fields; changes in pupillary response to mydriatics, defects in fixation and in smooth and saccadic eye movements; changes in contrast sensitivity and in visual evoked potentials (VEP); and disturbances of complex visual functions such as reading, visuospatial function, and in the naming and identification of objects. Many of these changes are controversial with conflicting data in the literature and no ocular or visual feature can be regarded as particularly diagnostic of AD. In addition, some pathological changes have been observed to affect the eye, visual pathway, and visual cortex in AD. The optometrist has a role in helping a patient with AD, if it is believed that signs and symptoms of the disease are present, so as to optimize visual function and improve the quality of life. (J Optom 2009;2:103-111 ©2009 Spanish Council of Optometry)
Resumo:
This thesis sets out to examine in detail the condition of systemic hypertension (high Blood Pressure) in relation to optometric practice in the United Kingdom. Systemic hypertension, which is asymptomatic in the early stages, is diagnosed from the Blood Pressure (BP) measurement recorded by a sphygmomanometer and/or from the complications that have developed in target organs. Optometric practice based surveys revealed that diagnosed systemic hypertension was the most prevalent cardiovascular medical condition (20.5%). Measurement of BP of patients in this sample revealed that if an optometrist included sphygmomanometry into the sight examination then at least one patient each day would be referred for suspect systemic hypertension. Optometric opinion felt that the measurement of BP in optometric practice would advance the profession, being appreciated by both patients and General Practitioners (GPs), but was felt to be an unnecessary routine procedure. The present sight examination for the systemic hypertensive is similar to that of the normotensive patient, but may involve an altered fundus examination and a visual field test. The GPs were in favour of optometric BP measurement and a future role in the share care management of the systemic hypertensive. The application of a new pictorial grading scale for the grading of vascular changes associated with pre-malignant systemic hypertension was found to be both accurate and reliable. Clinical trial of the grading scale in optometric practice found positive correlations between BP and increasing severity of the retinal vascular features. The subtle pre-malignant vascular changes require reliable accurate detection and analysis to assist in the management of the systemic hypertensive patient. Vessel width was shown to decrease with increasing age. Image analysis of the A/V ratio, arteriolar tortuosity and focal calibre changes revealed a positive correlation to the patient's BP (p<0.001). The retinal vasculature is relatively stable longitudinally with only minor changes in response to early disease states. Age and elevated BP increased a patient's risk of developing systemic medical conditions over a two-year period. The application of the pictorial grading scale to optometric practice and training the optometrist in the use of sphygmomanometry would improve the management of the systemic hypertensive patient in optometric practice. Future advances in image analysis hold substantial benefits for the detection and monitoring of subtle vascular changes associated with systemic hypertension.
Resumo:
Introduction: We have adapted the existing , optometry diabetic retinopathy screening pathway and software , so that it can be used for wet AMD fast track referral. Purpose: To compare the conventional, optometry wet AMD fast track referral service using FAX transmission, with a teleophthalmology service using colour fundus photography transmitted to a central retinal grading centre. Method: 40 optometry practices involved in diabetic retinopathy screening were enrolled and had modified computer software installed. Referrals were made by conventional fast track FAX to the macular clinic, and patients were photographed by the optometrist and images transmitted to a central grading centre Results of the two pathways were compared in terms of 1)speed of diagnosis and 2)sensitivity and specificity of diagnosis of wet AMD. Results: Over a ten month period, 62 consecutive patients were referred. The mean time for conventional pathway was 20.8 days (range 3-34),and for new teleophthalmology pathway was 6.9 days (range 1-13). Sensitivity of technician grading of images was 96%, Specificity 53%, and consultant ophthalmologist was sensitivity 96%, specificiity 87%. The technician showed a learning effect with specificity increasing from 30.7% for first 31 patient cohort, to 70.6% for the second cohort. One patient had images that could not be graded. Conclusion: Rapid referral of wet AMD cases by optometrists using modified diabetic retinopathy screening software, allows fast and accurate diagnosis, and may reduce unnecessary referrals. Retinal grading technicians can be trained to grade wet AMD images.
Resumo:
Background Ocular allergies frequently present in pharmacy practices. However, research into the actual management of ocular allergy in pharmacies is lacking. Objective To determine and quantify history and symptom questioning of a patient with presumed allergic conjunctivitis and management strategies employed by pharmacy staff in the UK. Method A mystery shopper technique was used to simulate an episode of allergic conjunctivitis in 100 community pharmacies across the UK. Results The mean number of questions asked by pharmacy staff to the patient was 3.5 ± 2.6, with a range of 0-10. The most common question was whether the patient had a history of allergies (45 %).Ninety-one percent advised on treatment, with the remaining 9 % directly referring to the patient's general practitioner (n = 4) or pharmacist(n = 4), but only two to their optometrist. The most common treatment suggested was sodium cromoglycate 2 % (50 %). However, many pharmacies advising treatment did not ask the patient's age (37 %), if they wore contact lenses (43 %), or gave dosage advice (43 %). Only 5 % of pharmacies advised follow up and 14 % suggested visiting a general practitioner and 1 % an optometrist if symptoms did not resolve with treatment. Conclusion There is a need for improved ophthalmological training for pharmacy staff with respect to the management of allergic conjunctivitis. © Springer Science+Business Media Dordrecht 2012.
Resumo:
A clinical evaluation of the Shin-Nippon SRW-5000 (Japan), a newly released commercial autorefractor, was undertaken to assess its repeatability and validity compared to subjective refraction. Measurements of refractive error were performed on 200 eyes of 100 subjects (aged 24.4±8.0 years) subjectively (non-cycloplegic) by one optometrist and objectively with the SRW-5000 autorefractor by a second. Repeatability was assessed by examining the differences between the seven autorefractor readings taken from each eye and by re-measuring the objective prescription of 50 eyes at a subsequent session. Although the SRW-5000 read slightly more plus than subjective refraction (mean spherical equivalent +0.16±0.44D), it was found to be highly valid (accurate) compared to subjective refraction and repeatable over the prescription range of +6.50 to -15.00D examined. The Shin-Nippon SRW-5000 autorefractor is therefore a valuable complement to subjective refraction and as it offers the advantage of a binocular open field-of-view, has a great potential benefit for accommodation research studies. Copyright © 2001 The College of Optometrists.