902 resultados para Optical computers


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this Letter we numerically investigate the fault-tolerant threshold for optical cluster-state quantum computing. We allow both photon loss noise and depolarizing noise (as a general proxy for all local noise), and obtain a threshold region of allowed pairs of values for the two types of noise. Roughly speaking, our results show that scalable optical quantum computing is possible for photon loss probabilities < 3x10(-3), and for depolarization probabilities < 10(-4).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumen El diseño de sistemas ópticos, entendido como un arte por algunos, como una ciencia por otros, se ha realizado durante siglos. Desde los egipcios hasta nuestros días los sistemas de formación de imagen han ido evolucionando así como las técnicas de diseño asociadas. Sin embargo ha sido en los últimos 50 años cuando las técnicas de diseño han experimentado su mayor desarrollo y evolución, debido, en parte, a la aparición de nuevas técnicas de fabricación y al desarrollo de ordenadores cada vez más potentes que han permitido el cálculo y análisis del trazado de rayos a través de los sistemas ópticos de forma rápida y eficiente. Esto ha propiciado que el diseño de sistemas ópticos evolucione desde los diseños desarrollados únicamente a partir de la óptica paraxial hasta lo modernos diseños realizados mediante la utilización de diferentes técnicas de optimización multiparamétrica. El principal problema con el que se encuentra el diseñador es que las diferentes técnicas de optimización necesitan partir de un diseño inicial el cual puede fijar las posibles soluciones. Dicho de otra forma, si el punto de inicio está lejos del mínimo global, o diseño óptimo para las condiciones establecidas, el diseño final puede ser un mínimo local cerca del punto de inicio y lejos del mínimo global. Este tipo de problemática ha llevado al desarrollo de sistemas globales de optimización que cada vez sean menos sensibles al punto de inicio de la optimización. Aunque si bien es cierto que es posible obtener buenos diseños a partir de este tipo de técnicas, se requiere de muchos intentos hasta llegar a la solución deseada, habiendo un entorno de incertidumbre durante todo el proceso, puesto que no está asegurado el que se llegue a la solución óptima. El método de las Superficies Múltiples Simultaneas (SMS), que nació como una herramienta de cálculo de concentradores anidólicos, se ha demostrado como una herramienta también capaz utilizarse para el diseño de sistemas ópticos formadores de imagen, aunque hasta la fecha se ha utilizado para el diseño puntual de sistemas de formación de imagen. Esta tesis tiene por objeto presentar el SMS como un método que puede ser utilizado de forma general para el diseño de cualquier sistema óptico de focal fija o v afocal con un aumento definido así como una herramienta que puede industrializarse para ayudar al diseñador a afrontar de forma sencilla el diseño de sistemas ópticos complejos. Esta tesis está estructurada en cinco capítulos: El capítulo 1, es un capítulo de fundamentos donde se presentan los conceptos fundamentales necesarios para que el lector, aunque no posea una gran base en óptica formadora de imagen, pueda entender los planteamientos y resultados que se presentan en el resto de capítulos El capitulo 2 aborda el problema de la optimización de sistemas ópticos, donde se presenta el método SMS como una herramienta idónea para obtener un punto de partida para el proceso de optimización. Mediante un ejemplo aplicado se demuestra la importancia del punto de partida utilizado en la solución final encontrada. Además en este capítulo se presentan diferentes técnicas que permiten la interpolación y optimización de las superficies obtenidas a partir de la aplicación del SMS. Aunque en esta tesis se trabajará únicamente utilizando el SMS2D, se presenta además un método para la interpolación y optimización de las nubes de puntos obtenidas a partir del SMS3D basado en funciones de base radial (RBF). En el capítulo 3 se presenta el diseño, fabricación y medidas de un objetivo catadióptrico panorámico diseñado para trabajar en la banda del infrarrojo lejano (8-12 μm) para aplicaciones de vigilancia perimetral. El objetivo presentado se diseña utilizando el método SMS para tres frentes de onda de entrada utilizando cuatro superficies. La potencia del método de diseño utilizado se hace evidente en la sencillez con la que este complejo sistema se diseña. Las imágenes presentadas demuestran cómo el prototipo desarrollado cumple a la perfección su propósito. El capítulo 4 aborda el problema del diseño de sistemas ópticos ultra compactos, se introduce el concepto de sistemas multicanal, como aquellos sistemas ópticos compuestos por una serie de canales que trabajan en paralelo. Este tipo de sistemas resultan particularmente idóneos para él diseño de sistemas afocales. Se presentan estrategias de diseño para sistemas multicanal tanto monocromáticos como policromáticos. Utilizando la novedosa técnica de diseño que en este capítulo se presenta el diseño de un telescopio de seis aumentos y medio. En el capítulo 5 se presenta una generalización del método SMS para rayos meridianos. En este capítulo se presenta el algoritmo que debe utilizarse para el diseño de cualquier sistema óptico de focal fija. La denominada optimización fase 1 se vi introduce en el algoritmo presentado de forma que mediante el cambio de las condiciones iníciales del diseño SMS que, aunque el diseño se realice para rayos meridianos, los rayos skew tengan un comportamiento similar. Para probar la potencia del algoritmo desarrollado se presenta un conjunto de diseños con diferente número de superficies. La estabilidad y potencia del algoritmo se hace evidente al conseguirse por primera vez el diseño de un sistema de seis superficies diseñado por SMS. vii Abstract The design of optical systems, considered an art by some and a science by others, has been developed for centuries. Imaging optical systems have been evolving since Ancient Egyptian times, as have design techniques. Nevertheless, the most important developments in design techniques have taken place over the past 50 years, in part due to the advances in manufacturing techniques and the development of increasingly powerful computers, which have enabled the fast and efficient calculation and analysis of ray tracing through optical systems. This has led to the design of optical systems evolving from designs developed solely from paraxial optics to modern designs created by using different multiparametric optimization techniques. The main problem the designer faces is that the different optimization techniques require an initial design which can set possible solutions as a starting point. In other words, if the starting point is far from the global minimum or optimal design for the set conditions, the final design may be a local minimum close to the starting point and far from the global minimum. This type of problem has led to the development of global optimization systems which are increasingly less sensitive to the starting point of the optimization process. Even though it is possible to obtain good designs from these types of techniques, many attempts are necessary to reach the desired solution. This is because of the uncertain environment due to the fact that there is no guarantee that the optimal solution will be obtained. The Simultaneous Multiple Surfaces (SMS) method, designed as a tool to calculate anidolic concentrators, has also proved useful for the design of image-forming optical systems, although until now it has occasionally been used for the design of imaging systems. This thesis aims to present the SMS method as a technique that can be used in general for the design of any optical system, whether with a fixed focal or an afocal with a defined magnification, and also as a tool that can be commercialized to help designers in the design of complex optical systems. The thesis is divided into five chapters. Chapter 1 establishes the basics by presenting the fundamental concepts which the reader needs to acquire, even if he/she doesn‟t have extensive knowledge in the field viii of image-forming optics, in order to understand the steps taken and the results obtained in the following chapters. Chapter 2 addresses the problem of optimizing optical systems. Here the SMS method is presented as an ideal tool to obtain a starting point for the optimization process. The importance of the starting point for the final solution is demonstrated through an example. Additionally, this chapter introduces various techniques for the interpolation and optimization of the surfaces obtained through the application of the SMS method. Even though in this thesis only the SMS2D method is used, we present a method for the interpolation and optimization of clouds of points obtained though the SMS3D method, based on radial basis functions (RBF). Chapter 3 presents the design, manufacturing and measurement processes of a catadioptric panoramic lens designed to work in the Long Wavelength Infrared (LWIR) (8-12 microns) for perimeter surveillance applications. The lens presented is designed by using the SMS method for three input wavefronts using four surfaces. The powerfulness of the design method used is revealed through the ease with which this complex system is designed. The images presented show how the prototype perfectly fulfills its purpose. Chapter 4 addresses the problem of designing ultra-compact optical systems. The concept of multi-channel systems, such as optical systems composed of a series of channels that work in parallel, is introduced. Such systems are especially suitable for the design of afocal systems. We present design strategies for multichannel systems, both monochromatic and polychromatic. A telescope designed with a magnification of six-and-a-half through the innovative technique exposed in this chapter is presented. Chapter 5 presents a generalization of the SMS method for meridian rays. The algorithm to be used for the design of any fixed focal optics is revealed. The optimization known as phase 1 optimization is inserted into the algorithm so that, by changing the initial conditions of the SMS design, the skew rays have a similar behavior, despite the design being carried out for meridian rays. To test the power of the developed algorithm, a set of designs with a different number of surfaces is presented. The stability and strength of the algorithm become apparent when the first design of a system with six surfaces if obtained through the SMS method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major research area is the representation of knowledge for a given application in a compact manner such that desired information relating to this knowledge is easily recoverable. A complicated procedure may be required to recover the information from the stored representation and convert it back to usable form. Coder/decoder are the devices dedicated to that task. In this paper the capabilities that an Optical Programmable Logic Cell offers as a basic building block for coding and decoding are analyzed. We have previously published an Optically Programmable Logic Cells (OPLC), for applications as a chaotic generator or as basic element for optical computing. In optical computing previous studies these cells have been analyzed as full-adder units, being this element a basic component for the arithmetic logic structure in computing. Another application of this unit is reported in this paper. Coder and decoder are basic elements in computers, for example, in connections between processors and memory addressing. Moreover, another main application is the generation of signals for machine controlling from a certain instruction. In this paper we describe the way to obtain a coder/decoder with the OPLC and which type of applications may be the best suitable for this type of cell.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The scaling of decoherence rates with qubit number N is studied for a simple model of a quantum computer in the situation where N is large. The two state qubits are localized around well-separated positions via trapping potentials and vibrational centre of mass motion of the qubits occurs. Coherent one and two qubit gating processes are controlled by external classical fields and facilitated by a cavity mode ancilla. Decoherence due to qubit coupling to a bath of spontaneous modes, cavity decay modes and to the vibrational modes is treated. A non-Markovian treatment of the short time behaviour of the fidelity is presented, and expressions for the characteristic decoherence time scales obtained for the case where the qubit/cavity mode ancilla is in a pure state and the baths are in thermal states. Specific results are given for the case where the cavity mode is in the vacuum state and gating processes are absent and the qubits are in (a) the Hadamard state (b) the GHZ state.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical-phase conjugation nonlinearity compensation (OPC-NLC) in optical networks is evaluated using a built-in tool including self-channel and crosstalk channel interference effects. Though significant improvements are observed, a further refined launch power policy is required to fully take advantage of OPC-NLC capability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the use of optical and nonoptical aids during reading and writing activities in individuals with acquired low vision. This study was performed using descriptive and cross-sectional surveys. The data collection instrument was created with structured questions that were developed from an exploratory study and a previous test based on interviews, and it evaluated the following variables: personal characteristics, use of optical and nonoptical aids, and activities that required the use of optical and nonoptical aids. The study population included 30 subjects with acquired low vision and visual acuities of 20/200-20/400. Most subjects reported the use of some optical aids (60.0%). Of these 60.0%, the majority (83.3%) cited spectacles as the most widely used optical aid. The majority (63.3%) of subjects also reported the use of nonoptical aids, the most frequent ones being letter magnification (68.4%), followed by bringing the objects closer to the eyes (57.8%). Subjects often used more than one nonoptical aid. The majority of participants reported the use of optical and nonoptical aids during reading activities, highlighting the use of spectacles, magnifying glasses, and letter magnification; however, even after the use of these aids, we found that the subjects often needed to read the text more than once to understand it. During writing activities, all subjects reported the use of optical aids, while most stated that they did not use nonoptical aids for such activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this cross-sectional observational study was to quantify the pattern-shift visual evoked potentials (VEP) and the thickness as well as the volume of retinal layers using optical coherence tomography (OCT) across a cohort of Parkinson's disease (PD) patients and age-matched controls. Forty-three PD patients and 38 controls were enrolled. All participants underwent a detailed neurological and ophthalmologic evaluation. Idiopathic PD cases were included. Cases with glaucoma or increased intra-ocular pressure were excluded. Patients were assessed by VEP and high-resolution Fourier-domain OCT, which quantified the inner and outer thicknesses of the retinal layers. VEP latencies and the thicknesses of the retinal layers were the main outcome measures. The mean age, with standard deviation (SD), of the PD patients and controls were 63.1 (7.5) and 62.4 (7.2) years, respectively. The patients were predominantly in the initial Hoehn-Yahr (HY) disease stages (34.8% in stage 1 or 1.5, and 55.8 % in stage 2). The VEP latencies and the thicknesses as well as the volumes of the retinal inner and outer layers of the groups were similar. A negative correlation between the retinal thickness and the age was noted in both groups. The thickness of the retinal nerve fibre layer (RNFL) was 102.7 μm in PD patients vs. 104.2 μm in controls. The thicknesses of retinal layers, VEP, and RNFL of PD patients were similar to those of the controls. Despite the use of a representative cohort of PD patients and high-resolution OCT in this study, further studies are required to establish the validity of using OCT and VEP measurements as the anatomic and functional biomarkers for the evaluation of retinal and visual pathways in PD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To investigate misalignments (MAs) on retinal nerve fiber layer thickness (RNFLT) measurements obtained with Cirrus(©) SD-OCT. Methods. This was a retrospective, observational, cross-sectional study. Twenty-seven healthy and 29 glaucomatous eyes of 56 individuals with one normal exam and another showing MA were included. MAs were defined as an improper alignment of vertical vessels in the en face image. MAs were classified in complete MA (CMA) and partial MA (PMA), according to their site: 1 (superior, outside the measurement ring (MR)), 2 (superior, within MR), 3 (inferior, within MR), and 4 (inferior, outside MR). We compared RNFLT measurements of aligned versus misaligned exams in all 4 sectors, in the superior area (sectors 1 + 2), inferior area (sectors 3 + 4), and within the measurement ring (sectors 2 + 3). Results. RNFLT measurements at 12 clock-hour of eyes with MAs in the superior area (sectors 1 + 2) were significantly lower than those obtained in the same eyes without MAs (P = 0.043). No significant difference was found in other areas (sectors 1 + 2 + 3 + 4, sectors 3 + 4, and sectors 2 + 3). Conclusion. SD-OCT scans with superior MAs may present lower superior RNFLT measurements compared to aligned exams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate an experimental animal model to study the abdominal tissue activity considering its interaction with a polypropylene mesh, through the use of one of the optical phenomena of light Laser, the biospeckle. METHODS: Fifty Wistar male rats were divided into four groups: Group 1: ten animals not submitted to surgery; Group 2: ten animals submitted to surgery without polypropylene mesh; Group 3: 20 animals submitted to surgery followed by the mesh placement; Group 4: (sham) with ten animals. None of the animals presented post surgical complications being submitted to the optical tests at the 20th postoperative day. RESULTS: The analysis from the biospeckle tests, comparing the medians and standard deviations with T Student test, indicated that no significative difference was observed on the abdominal wall tissue activity in the four groups considered, with and without polypropylene mesh prosthesis implantation. CONCLUSION: The animal model is viable and the biospeckle open ways for a great number of experiments to be developed in evaluating tissue activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The biochemical alterations between inflammatory fibrous hyperplasia (IFH) and normal tissues of buccal mucosa were probed by using the FT-Raman spectroscopy technique. The aim was to find the minimal set of Raman bands that would furnish the best discrimination. Background: Raman-based optical biopsy is a widely recognized potential technique for noninvasive real-time diagnosis. However, few studies had been devoted to the discrimination of very common subtle or early pathologic states as inflammatory processes that are always present on, for example, cancer lesion borders. Methods: Seventy spectra of IFH from 14 patients were compared with 30 spectra of normal tissues from six patients. The statistical analysis was performed with principal components analysis and soft independent modeling class analogy cross-validated, leave-one-out methods. Results: Bands close to 574, 1,100, 1,250 to 1,350, and 1,500 cm(-1) (mainly amino acids and collagen bands) showed the main intragroup variations that are due to the acanthosis process in the IFH epithelium. The 1,200 (C-C aromatic/DNA), 1,350 (CH(2) bending/collagen 1), and 1,730 cm(-1) (collagen III) regions presented the main intergroup variations. This finding was interpreted as originating in an extracellular matrix-degeneration process occurring in the inflammatory tissues. The statistical analysis results indicated that the best discrimination capability (sensitivity of 95% and specificity of 100%) was found by using the 530-580 cm(-1) spectral region. Conclusions: The existence of this narrow spectral window enabling normal and inflammatory diagnosis also had useful implications for an in vivo dispersive Raman setup for clinical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy of photodynamic therapy (PDT) depends on a variety of parameters: concentration of the photosensitizer at the time of treatment, light wavelength, fluence, fluence rate, availability of oxygen within the illuminated volume, and light distribution in the tissue. Dosimetry in PDT requires the congregation of adequate amounts of light, drug, and tissue oxygen. The adequate dosimetry should be able to predict the extension of the tissue damage. Photosensitizer photobleaching rate depends on the availability of molecular oxygen in the tissue. Based on photosensitizers photobleaching models, high photobleaching has to be associated with high production of singlet oxygen and therefore with higher photodynamic action, resulting in a greater depth of necrosis. The purpose of this work is to show a possible correlation between depth of necrosis and the in vivo photosensitizer (in this case, Photogem (R)) photodegradation during PDT. Such correlation allows possibilities for the development of a real time evaluation of the photodynamic action during PDT application. Experiments were performed in a range of fluence (0-450 J/cm(2)) at a constant fluence rate of 250 mW/cm(2) and applying different illumination times (0-1800 s) to achieve the desired fluence. A quantity was defined (psi) as the product of fluorescence ratio (related to the photosensitizer degradation at the surface) and the observed depth of necrosis. The correlation between depth of necrosis and surface fluorescence signal is expressed in psi and could allow, in principle, a noninvasive monitoring of PDT effects during treatment. High degree of correlation is observed and a simple mathematical model to justify the results is presented.