877 resultados para Operational amplifiers
Resumo:
The departures of the operational amplifiers (OA's) from the ideal performance and their effect on VCV's in the inverting and noninverting mode are discussed. It is found that for the same ideal gain, the bandwidths for the inverting and noninverting modes are different, the former being less. Complete equivalent circuits describing the frequency dependance of the input and output impedances for both modes are given. In particular, the output impedance is shown to be inductive for the frequencies of interest, and this is also confirmed by experimental results.
Resumo:
The deviation in the performance of active networks due to practical operational amplifiers (OA) is mainly because of the finite gain bandwidth productBand nonzero output resistanceR_0. The effect ofBandR_0on two OA impedances and single and multi-OA filters are discussed. In filters, the effect ofR_0is to add zeros to the transfer function often making it nonminimum phase. A simple method of analysis has been suggested for 3-OA biquad and coupled biquad circuits. A general method of noise minimization of the generalized impedance converter (GIC), while operating OA's within the prescribed voltage and current limits, is also discussed. The 3-OA biquadratic sections analyzed also exhibit noise behavior and signal handling capacity similar to the GIC. The GIC based structures are found to be better than other configurations both in biquadratic sections and direct realizations of higher order transfer functions.
Resumo:
A procedure has been given for minimizing the total output noise of a Generalized Impedance Converter (GIC), subject to constraints dictated by signal handling capability of the Operational Amplifiers and ease of microcircuit fabrication. The noise reduction is achieved only by the adjustment of RC elements of the GIC, and the total output noise after optimization in the example cited is close to the theoretical lower limit. The output noise of a higher-order filter can be reduced by RC-optimizing the individual GIC's of the active realization. Experimental results on a 20–24 kHz channel bank band-pass filter demonstrate the effectiveness of the above procedure.
Resumo:
A new method of network analysis, a generalization in several different senses of existing methods and applicable to all networks for which a branch-admittance (or impedance) matrix can be formed, is presented. The treatment of network determinants is very general and essentially four terminal rather than three terminal, and leads to simple expressions based on trees of a simple graph associated with the network and matrix, and involving products of low-order, usually(2 times 2)determinants of tree-branch admittances, in addition to tree-branch products as in existing methods. By comparison with existing methods, the total number of trees and of tree pairs is usually considerably reduced, and this fact, together with an easy method of tree-pair sign determination which is also presented, makes the new method simpler in general. The method can be very easily adapted, by the use of infinite parameters, to accommodate ideal transformers, operational amplifiers, and other forms of network constraint; in fact, is thought to be applicable to all linear networks.
Resumo:
Closed loop current sensors used in power electronics applications are expected to have high bandwidth and minimal measurement transients. In this paper, a closed loop compensated Hall-effect current sensor is modeled. The model is used to tune the sensor's compensator. Analytical expression of step response is used to evaluate the performance of the PI compensator in the current sensor. This analysis is used to devise a procedure to design parameters of the PI compensator for fast dynamic response and for small dynamic error. A prototype current sensor is built in the laboratory. Simulations using the model are compared with experimental results to validate the model and to study the variation in performance with compensator parameters. The performance of the designed PI compensator for the sensor is compared with a commercial current sensor. The measured bandwidth of the designed current sensor is above 200 kHz, which is comparable to commercial standards. Implementation issues of PI compensator using operational amplifiers are also addressed.
Resumo:
针对远距离声源发射的水声信号微弱、水声接收设备电源能量有限的特点,提出一种功耗小、对无源元件误差灵敏度低、高增益放大的微弱水声信号通用放大电路。系统采用场效应管共源单调谐放大器为前置放大级,由四级级联低功耗运放构成带通滤波放大电路,省去传统的R、C低通网络,实现了对微弱水声信号的高增益放大和海洋背景噪声的归一化处理。通过计算电路网络传递函数极点证明了电路系统的稳定性。海上使用表明系统具有精度高、适应性强、电路稳定性好、功耗小等优点。
Resumo:
叙述了在自动控制、仪器仪表、信号变换以及传感器信号采集与处理等电路中实现大时间常数的一种新方法。根据近代电工理论中的回转器原理 ,利用运算放大器及电阻、电容器件可以实现模拟电容和模拟电感。给出了理论计算与应用实例
Resumo:
A novel Lorenz-type system of nonlinear differential equations is proposed. Unlike the original Lorenz system, where the chaotic dynamics remain confined to the positive half-space with respect to the Z state variable due to a limiting threshold effect, the proposed system enables bipolar swing of this state variable. In addition, the classical set of parameters (a, b, c) controlling the behavior of the Lorenz system are reduced to a single parameter, namely a. Two possible modes of operation are admitted by the system; switching between these two modes results in the creation of a complex butterfly chaotic attractor. Numerical simulations and results from an experimental setup are presented
Resumo:
Neste trabalho são apresentados o desenvolvimento e a implementação de estratégias de controle digital para regulação automática de tensão e para o amortecimento de oscilações eletromecânicas em um sistema de potência em escala reduzida de 10kVA, localizado no Laboratório de Controle de Sistemas de Potência (LACSPOT), da Universidade Federal do Pará (UFPA). O projeto dos dois controladores é baseado na técnica de alocação polinomial de polos. Para o projeto do Regulador Automático de Tensão (RAT) foi adotado um modelo simplificado, de primeira ordem, da máquina síncrona, cujos parâmetros foram levantados experimentalmente. Para o controlador amortecedor, por sua vez, também chamado de Estabilizador de Sistemas de Potência (ESP), foi utilizado um modelo discreto, do tipo auto regressivo com entrada exógena (ARX). Este modelo foi estimado por meio de técnicas de identificação paramétrica, considerando para tal, o conjunto motor-gerador interligado a um sistema de maior porte (concessionária de energia elétrica). As leis de controle foram embarcadas em um microcontrolador de alto desempenho e, para a medição dos sinais utilizados nos controladores, foi desenvolvida uma instrumentação eletrônica baseada em amplificadores operacionais para o condicionamento dos sinais dos sensores. O sinal de controle é baseado na técnica de modulação por largura de pulso (PWM) e comanda o valor médio da tensão de um conversor CC-CC, o qual é utilizado como circuito de excitação que energiza o enrolamento de campo do gerador. Além disso, o acionamento elétrico das máquinas que compõem o grupo gerador de 10kVA foi projetado e automatizado somando segurança aos operadores e ao componentes deste sistema de geração. Os resultados experimentais demonstraram o bom desempenho obtido pela estratégia proposta.
Resumo:
A circuit for transducer linearizer tasks have been designed and built using discrete components and it implements by: a Radial Basis Function Network (RBFN) with three basis functions. The application in a linearized thermistor showed that the network has good approximation capabilities. The circuit advantages is the amplitude, width and center.
Resumo:
Las FPAA´s son dispositivos analógicos programables. Estos dispositivos se basan en el uso de condensadores conmutados junto con amplificadores operacionales. Este tipo de tecnología presenta una serie de ventajas, ya que combinan las ventajas de dispositivos digitales, como la reprogramación en función de las variables del entorno que los rodean, con la diferencia de ser dispositivos analógicos, permitiendo la realización de una amplia gama de diseños analógicos en un solo chip. En este proyecto se ha realizado un estudio sobre el funcionamiento de los condensadores conmutados y su uso en el dispositivo AN221E04 del fabricante Anadigm. Una vez descrita la arquitectura del AN221E04 y explicadas las bases del funcionamiento de los condensadores conmutados, utilizando como ejemplo los modelos facilitados por Anadigm, se desarrolla un modelo de amplificador de instrumentación teórico y se describe la metodología para su implementación en un AN221E04 con el software Anadigm Designer 2. Una vez implementado este modelo de amplificador de instrumentación se han efectuado una serie de pruebas con el objetivo de estudiar la capacidad de estos dispositivos. Dichas pruebas ponen de manifiesto que las FPAA´s tienen una serie de ventajas a tener en cuenta a la hora de realizar diseños analógicos. La precisión obtenida por el modelo de amplificador de instrumentación realizado es más que aceptable, llegando a obtener errores de ganancia inferiores al 1% con ganancias de 200V/V sin tener la necesidad de realizar grandes ajustes. En las conclusiones de este estudio se exponen tanto ventajas como inconvenientes de la utilización de FPAA´s en diseños analógicos. La principal ventaja de este uso es el ahorro de costes, ya que una vez desarrollada una plataforma de diseño, la capacidad de reconfiguración permite utilizar dicha plataforma para un amplio abanico de aplicaciones, reduciendo el número de componentes y simplificando las etapas de diseño. Como desventaja, las FPAA´s tienen una serie de limitaciones qué hay que tener en cuenta en ciertos casos pudiendo hacer irrealizable un diseño concreto; como puede ser el valor máximo o mínimo de ganancia. The FPAA's are programmable analog devices. These devices rely on the use of switched capacitors together with operational amplifiers. This type of technology has a number of advantages, because they combine the advantages of digital devices such as the reprogramming function of the variables of the surrounding environment, with the difference being analog devices, allowing the realization of a wide range of designs analog on a single chip. This project has conducted a study on the operation of the switched capacitor and its use in the device AN221E04 from Anadigm. Having described the architecture of AN221E04 and explained the basis for the operation of the switched capacitor, using the example models provided by Anadigm is developing an instrumentation amplifier theory model and describes the methodology for implementation in a AN221E04 with the Anadigm Designer 2 software. Once implemented this instrumentation amplifier model, have made a series of tests in order to study the ability of these devices. These tests show that the FPAA's have a number of advantages to take into account when making analog designs. The accuracy obtained by the instrumentation amplifier model is made more than acceptable, earning gain errors of less than 1% with gains of 200V / V without the need for major adjustments. The conclusions of this study are presented both advantages and disadvantages of using FPAA's in analog designs. The main advantage of this application is the cost savings, because once developed a platform for design, reconfiguration capability allows you to use this platform for a wide range of applications, reducing component count and simplifying design stages. As a disadvantage, the FPAA's have a number of limitations which must be taken into account in certain cases may make impossible a specific design, such as the maximum or minimum gain, or the magnitude of the possible settings.
Resumo:
Some photodetectors like PMTs and SiPMs give pulses of few nanosecond width at their outputs, which need to be properly processed with analog circuits. Power splitters with two and three outputs are required to distribute this kind of fast pulses equally among different outputs. Good matching and low pass response are necessary to avoid shape deformation, which discard low frequency designs with operational amplifiers. To match these requirements two Wilkinson dividers were designed, substituting the lambda quarter lines for lumped elements. These changes provide us with low pass response and much smaller size, using SMD devices. The splitters were manufactured and measured, with good results.
Resumo:
The modulation instability (MI) is one of the main factors responsible for the degradation of beam quality in high-power laser systems. The so-called B-integral restriction is commonly used as the criteria for MI control in passive optics devices. For amplifiers the adiabatic model, assuming locally the Bespalov-Talanov expression for MI growth, is commonly used to estimate the destructive impact of the instability. We present here the exact solution of MI development in amplifiers. We determine the parameters which control the effect of MI in amplifiers and calculate the MI growth rate as a function of those parameters. The safety range of operational parameters is presented. The results of the exact calculations are compared with the adiabatic model, and the range of validity of the latest is determined. We demonstrate that for practical situations the adiabatic approximation noticeably overestimates MI. The additional margin of laser system design is quantified. © 2010 Optical Society of America.