906 resultados para On-line test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nursing school graduates are under pressure to pass the RN-NCLEX Exam on the first attempt since New York State monitors the results and uses them to evaluate the school’s nursing programs. Since the RN-NCLEX Exam is a standardized test, we sought a method to make our students better test takers. The use of on-line computer adaptive testing has raised our student’s standardized test scores at the end of the nursing course.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An on-line algorithm is developed for the location of single cross point faults in a PLA (FPLA). The main feature of the algorithm is the determination of a fault set corresponding to the response obtained for a failed test. For the apparently small number of faults in this set, all other tests are generated and a fault table is formed. Subsequently, an adaptive procedure is used to diagnose the fault. Functional equivalence test is carried out to determine the actual fault class if the adaptive testing results in a set of faults with identical tests. The large amount of computation time and storage required in the determination, a priori, of all the fault equivalence classes or in the construction of a fault dictionary are not needed here. A brief study of functional equivalence among the cross point faults is also made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An on-line algorithm is developed for the location of single cross point faults in a PLA (FPLA). The main feature of the valgorithm is the determination of a fault set corresponding to the response obtained for a failed test. For the apparently small number of faults in this set, all other tests are generated and a fault table is formed. Subsequently, an adaptive procedure is used to diagnose the fault. Functional equivalence test is carried out to determine the actual fault class if the adaptive testing results in a set of faults with identical tests. The large amount of computation time and storage required in the determination, a priori, of all the fault equivalence classes or in the construction of a fault dictionary are not needed here. A brief study of functional equivalence among the cross point faults is also made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

XXIV, 508 p.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a solid phase extraction mini-column home-made from a neutral extractant Cyanex 923, inorganic Hg could be on-line preconcentrated and simultaneously separated from methyl mercury. The preconcentrated Hg (11) was then eluted with 10% HNO3 and subsequently reduced by NaBH4 to form Hg vapor before determination by cold vapor atomic absorption spectrometry (CVAAS). Optimal conditions for and interferences on the Hg preconcentration and measurement were at 1% HCl, for a 25 mL sample uptake volume and a 10 mL min(-1) sample loading rate. The detection limit was 0.2 ng L-1 and much lower than that of conventional method (around 15.8 ng L-1). The relative standard deviation (RSD) is 1.8% for measurements of 40 ng L-1 of Hg and the linear working curve is from 20 to 2000 ng L-1 (with a correlation coefficient of 0.9996). The method was applied in determination of inorganic Hg in city lake and deep well water (from Changchun, Jilin, China), and recovery test results for both samples were satisfactory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biopolttoaineet ovat tärkeä energianlähde suomalaisessa energiantuotannossa. Biopoltto- aineille on kuitenkin ominaista laadun vaihtelevuus. Yksi tärkeimmistä laatutekijöistä on kosteus, joka vaikuttaa myös polttoaineen energiasisältöön. Laatutekijät puolestaan vai- kuttavat polttoainekäsittelyyn, polttoprosessiin ja koko laitoksen hyötysuhteeseen. Tämän työn tarkoituksena oli tutkia voisiko biopolttoaineiden online-laadunmittaus tuoda lisäarvoa energiantuotantolaitokselle. Esimerkkinä käytettiin yhtä online-laadunmittaus- sovellusta, InrayFuel-röntgenmittausjärjestelmää. Sillä voidaan seurata biopolttoaineiden kosteutta ja polttoaineen sisältämiä vierasaineita. Työssä on laadittu kustannusanalyysi, jolla pyritään selvittämään, onko nykyisen kertaluontoisen mittausmenetelmän korvaami- nen jatkuvatoimisella kannattavaa. Esimerkkilaitoksena on Etelä-Savon Energian Pur- sialan voimalaitos, jossa röntgenmittausjärjestelmään on testattu. Saatujen tulosten mukaan investoiminen esimerkkimittausjärjestelmään maksaisi itsensä takaisin alle vuodessa. Kun laitoksella pystytään seuraamaan polttoaineen laatua jatkuva- toimisesti, laadunhallinta paranee ja sitä kautta voidaan saavuttaa kustannussäästöjä. Polt- toaineesta johtuvat häiriötilanteet vähenevät, polttoaine on mahdollista optimoida edulli- semmaksi polton kannalta ja poltto-olosuhteita voidaan säätää paremmin, jolloin päästöt vähenevät ja hyötysuhde kasvaa. Työssä käytetty laskenta analysoi kuitenkin hyvin ylei- sellä tasolla, sillä käytössä ei ollut laitoksen omaa taselaskentajärjestelmää. Laskenta siis sisältää paljon oletuksia. Tämän ja rohkaisevien tulosten vuoksi tutkimusta jatkuvatoimi- sen laadunmittauksen hyödyistä kannattaa tehdä enemmän.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dado el interés que se presenta con los temas de gobierno corporativo, este trabajo busca describir si la divulgación on-line de los contenidos de los códigos de buen gobierno, es determinante en el posicionamiento que tienen las Instituciones de Educación Superior (IES) en el ranking QS. Partiendo de una muestra de 20 IES, se recolectaron un conjunto de datos dicotómicos para 30 variables independientes y se relacionaron con la variable dependiente denominada posicionamiento en el ranking. A partir de lo anterior, se elaboró un trabajo descriptivo y correlacional con el fin de probar las hipótesis de investigación. Este estudio reveló que la divulgación on-line de los contenidos de los códigos de buen gobierno en las IES, no es determinante para el posicionamiento en el ranking QS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The computational grammatical complexity ( CGC) hypothesis claims that children with G(rammatical)-specific language impairment ( SLI) have a domain-specific deficit in the computational system affecting syntactic dependencies involving 'movement'. One type of such syntactic dependencies is filler-gap dependencies. In contrast, the Generalized Slowing Hypothesis claims that SLI children have a domain-general deficit affecting processing speed and capacity. Aims: To test contrasting accounts of SLI we investigate processing of syntactic (filler-gap) dependencies in wh-questions. Methods & Procedures: Fourteen 10; 2 - 17; 2 G-SLI children, 14 age- matched and 17 vocabulary-matched controls were studied using the cross- modal picturepriming paradigm. Outcomes & Results: G-SLI children's processing speed was significantly slower than the age controls, but not younger vocabulary controls. The G- SLI children and vocabulary controls did not differ on memory span. However, the typically developing and G-SLI children showed a qualitatively different processing pattern. The age and vocabulary controls showed priming at the gap, indicating that they process wh-questions through syntactic filler-gap dependencies. In contrast, G-SLI children showed priming only at the verb. Conclusions: The findings indicate that G-SLI children fail to establish reliably a syntactic filler- gap dependency and instead interpret wh-questions via lexical thematic information. These data challenge the Generalized Slowing Hypothesis account, but support the CGC hypothesis, according to which G-SLI children have a particular deficit in the computational system affecting syntactic dependencies involving 'movement'. As effective remediation often depends on aetiological insight, the discovery of the nature of the syntactic deficit, along side a possible compensatory use of semantics to facilitate sentence processing, can be used to direct therapy. However, the therapeutic strategy to be used, and whether such similar strengths and weaknesses within the language system are found in other SLI subgroups are empirical issues that warrant further research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the first realtime ionospheric predictions network and its capabilities to ingest a global database and forecast F-layer characteristics and "in situ" electron densities along the track of an orbiting spacecraft. A global network of ionosonde stations reported around-the-clock observations of F-region heights and densities, and an on-line library of models provided forecasting capabilities. Each model was tested against the incoming data; relative accuracies were intercompared to determine the best overall fit to the prevailing conditions; and the best-fit model was used to predict ionospheric conditions on an orbit-to-orbit basis for the 12-hour period following a twice-daily model test and validation procedure. It was found that the best-fit model often provided averaged (i.e., climatologically-based) accuracies better than 5% in predicting the heights and critical frequencies of the F-region peaks in the latitudinal domain of the TSS-1R flight path. There was a sharp contrast however, in model-measurement comparisons involving predictions of actual, unaveraged, along-track densities at the 295 km orbital altitude of TSS-1R In this case, extrema in the first-principle models varied by as much as an order of magnitude in density predictions, and the best-fit models were found to disagree with the "in situ" observations of Ne by as much as 140%. The discrepancies are interpreted as a manifestation of difficulties in accurately and self-consistently modeling the external controls of solar and magnetospheric inputs and the spatial and temporal variabilities in electric fields, thermospheric winds, plasmaspheric fluxes, and chemistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us simultaneously to measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the online water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δ D robustness. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water, resulting in an artificial water background with well-known δ D and δ18O values. The speleothem sample is placed in a copper tube, attached to the line, and after system stabilisation it is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements, a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain &delta D; and δ18O isotopic compositions of measured water aliquots. Precision is better than 1.5 ‰ for δ D and 0.4 ‰ for δ18O for water measurements for an extended range (−210 to 0 ‰ for δ D and −27 to 0 ‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to the isotope ratio mass spectrometry (IRMS) technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project has been made in cooperation with Stora Enso Research Centre Falun (Research). Thebackground of the project is that Research has customers who demand a method to measure the quantityof varnish online in offset printing. The aim with the project is to investigate if any test method correlateswith the quantity of varnish and to improve the understanding of the variables in the varnishingunit. The goal with the project is to develop a functional method. Two printing trials have beenperformed. The aim with the first trial was to investigate how different factors in the printer influencedthe quantity of varnish using reduced factoranalysis. The aim of the second trial was to analyse onlya reduced numbers of factors in the varnishing unit. The methods that were used to measure the varnishingquantity are weighing, IR-analysis, gloss, whiteness and brightness. Results from the projectshow that the weighing method does not work in this study due to basis weight variations of the sheets.The results from weighing did not agree with the results from the other methods. On the other handthere is a strong correation between the IR- and the glossmethods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Design - FAAC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)