990 resultados para Olmedo, José Joaquín de, 1780-1847.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biographical foot-notes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A poem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Crítica al poema: homenaje de la Academia Colombiana de Historia en el sesquicentenario de la batalla de Junín, 1974; edición dirigida por Rafael Bernal Medina, miembro de número, Litografía Arco, Bogotá, Colombia": p.85-122.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. Simón Bolívar.--2. El genral S. Martín--3. José Morales Lemus.--4. José Joaquín de Olmedo.--5. Daniel Wébster.--6. José Francisco Heredia.--7. Gabriel de la Concepción Valdés.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

At head of title: César Arroyo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Apuntes biográficos del Sr. D. José Joaquin Pesado": signed R.B. de la Colina.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El uso de las partículas magnéticas ha venido a más durante los últimos 10 años. Lo anterior ha estado condicionado por factores como la amplia investigación en materiales a nivel atómico, los retos propuestos por las diferentes áreas de investigación donde los niveles nanométricos cobran importancia, la inherente innovación tecnológica que pueden aportar a la industria dichas escalas y finalmente, el impacto socioeconómico que pueden tener estos avances tecnológicos. Sin embargo, la traslación a la industria de los avances tecnológicos se ha visto limitada por la falta de estrategias, ya que el 88% del conocimiento se queda en Universidades y Centros de Investigación y el resto, 12%, pasa a la industria o es obtenido en ella. En este trabajo de investigación se ha tratado de completar el círculo de idea, conceptualización, generación de conocimiento, prototipo, prueba in vitro y prueba in vivo; todo ello para dejar el menor espacio posible entre Investigación e Industria. Se ha fabricado un recinto que permite la observación del comportamiento de las partículas magnéticas cuando están inmersas en un medio con viscosidad controlada y con una fuente magnética estática. De la observación experimental se han encontrado fenómenos magnéticos como la aglomeración y la autoorganización, que han sido aprovechados, no solo para ofrecer una solución alternativa a la corrección del desprendimiento de retina, sino también para promover las mejoras de métodos de separación y/o filtrado celular, ayuda en correcciones ortopédicas o en el diagnóstico y tratamiento de enfermedades degenerativas. Particularizando en la corrección del desprendimiento de retina, se ha desarrollado y patentado un Dispositivo Ocular cuya función es la de tapón del agujero retiniano, ayudando en la cicatrización de la retina. Dicho dispositivo ha sido evaluado en conejos albinos neozelandeses obteniéndose un éxito en la reaplicación de la retina del 80% y resultando su toxicidad en condición difusa tras evaluación anatomopatológica. Así mismo, el ferrofluido diseñado y fabricado se ha localizado en la zona de interacción magnética siempre y su disposición ha sido en el mayor de los casos en forma de placa pero también se han formado anillos; lo anterior no ha afectado en ningún sentido el éxito en la reaplicación de la retina. Por otro lado, no se han encontrado indicios de siderosis en la zona de interacción magnética, sus alrededores o el resto del globo ocular; ni las células han presentado apoptosis inducida por los materiales introducidos en el ojo. Sin embargo, se ha encontrado una fuerte necrosis inducida por la presión ejercida sobre la retina por el dispositivo ocular, evidenciando la necesidad de un mejor control de dicha presión. Tras la caracterización de los copos y la presión que éstos ejercen, se ha podido identificar que el dispositivo ocular se puede sintonizar para inducir una presión entre 0.5 y 2.5 mmHg; por tanto se puede vislumbrar que es posible minimizar la muerte celular causada en las células retinianas. Finalmente, tras la experimentación con conejos se ha observado que el dispositivo ocular resuelve los problemas inducidos por las siliconas o los gases e inclusive aporta ventajas competitivas de alto valor añadido como: no requerir de posiciones incómodas en el post-operatorio, no modifica las propiedades ópticas del ojo ya que no es necesario dejar silicona o gases en el interior del ojo, se pueden sellar múltiples agujeros retinianos, corrección de desprendimiento de retina inferior sin complicaciones asociadas, etc.; en definitiva mejora la calidad de vida domiciliaria del paciente además de solventar los problemas inducidos por las soluciones actuales. The using of magnetic particles has become more important during last 10 years. This event has been conditioned by several factors like a wide researching on materials at atomic level, the challenges proposed by different research areas where nanometric levels became important, the inherent technological innovation to the industry and finally, the socioeconomic impact of these kinds of technologies. However, the nanotechnological advances have not been well addressed to the industry since 88% of the acknowledge keeps on Universities and Research Centers, and the remaining 12% goes through the industry or is obtained in it. In this research work, we have tried to complete the entire process about idea, concept, acknowledge generation, prototyping and in vitro and in vivo testing; all to leave as little space as possible between Research and Industry. We have built an experimental hall which allows us the observation of magnetic particles' behavior when are immersing in a controlled viscous medium and under a static magnetic field. The experimental observation has been useful to identify and use two magnetic phenomena: agglomeration and self-organization; no only for retinal detachment, but also to improve cellular separation and/or filtered methods, orthopedic solutions or the diagnostic and treatment of degenerative diseases. Particularizing on retinal detachment, we have developed and patented an Ocular Device which its function is acting like a tampon of the retinal hole for helping with the scarring retina. The device has been evaluated in animals and the results show that we can achieve a success of 80% before rabbit’s death and non cell apoptosis, only necrosis, over the retina attached by the ocular device after anatomopathological evaluation. Also we have identified a diffuse toxicity after anatomopathological evaluation, so more experimenting must be proposed. Otherwise, the ferrofluid has been localized where the magnetic interaction area is located and its deposition has been in most cases plaque shape like but rings have also been observed; this has not affected in any way the successful reattachment of the retina. On the other hand, we have not found any evidence of siderosis in the magnetic interaction zone, near of or some other place of the ocular globe; and we did not find any apoptosis induced by the materials inserted within the eye. However full necrosis, exactly on the magnetic interaction zone, has been found and induced by the pressure exerted over the retina by the ocular device, evidencing the needing of its better control. After flakes’ characterization and its pressure exerted, we identified that the ocular device can be tuned in order to induce a pressure between 0.5 and 2.5 mmHg; therefore we can perceive that death caused to the retinal cells can be minimized. Finally, the experimentation has shown that the ocular device solves all problems induced by silicone or gases an even contributes with some other competitive advantages of high added value like: no uncomfortable postoperative positions, it does not modify any optical property of the eye because there is no needing of leaving silicone or gases inside the eye, many holes can be sealed, the inferior retinal detachment can be solve without any complications, etc.; definitively the ocular device improves patients’ quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Bioinstrumentation Laboratory belongs to the Centre for Biomedical Technology (CTB) of the Technical University of Madrid and its main objective is to provide the scientific community with devices and techniques for the characterization of micro and nanostructures and consequently finding their best biomedical applications. Hyperthermia (greek word for “overheating”) is defined as the phenomenon that occurs when a body is exposed to an energy generating source that can produce a rise in temperature (42-45ºC) for a given time [1]. Specifically, the aim of the hyperthermia methods used in The Bioinstrumentation Laboratory is the development of thermal therapies, some of these using different kinds of nanoparticles, to kill cancer cells and reduce the damage on healthy tissues. The optical hyperthermia is based on noble metal nanoparticles and laser irradiation. This kind of nanoparticles has an immense potential associated to the development of therapies for cancer on account of their Surface Plasmon Resonance (SPR) enhanced light scattering and absorption. In a short period of time, the absorbed light is converted into localized heat, so we can take advantage of these characteristics to heat up tumor cells in order to obtain the cellular death [2]. In this case, the laboratory has an optical hyperthermia device based on a continuous wave laser used to kill glioblastoma cell lines (1321N1) in the presence of gold nanorods (Figure 1a). The wavelength of the laser light is 808 nm because the penetration of the light in the tissue is deeper in the Near Infrared Region. The first optical hyperthermia results show that the laser irradiation produces cellular death in the experimental samples of glioblastoma cell lines using gold nanorods but is not able to decrease the cellular viability of cancer cells in samples without the suitable nanorods (Figure 1b) [3]. The generation of magnetic hyperthermia is performed through changes of the magnetic induction in magnetic nanoparticles (MNPs) that are embedded in viscous medium. The Figure 2 shows a schematic design of the AC induction hyperthermia device in magnetic fluids. The equipment has been manufactured at The Bioinstrumentation Laboratory. The first block implies two steps: the signal selection with frequency manipulation option from 9 KHz to 2MHz, and a linear output up to 1500W. The second block is where magnetic field is generated ( 5mm, 10 turns). Finally, the third block is a software control where the user can establish initial parameters, and also shows the temperature response of MNPs due to the magnetic field applied [4-8]. The Bioinstrumentation Laboratory in collaboration with the Mexican company MRI-DT have recently implemented a new research line on Nuclear Magnetic Resonance Hyperthermia, which is sustained on the patent US 7,423,429B2 owned by this company. This investigation is based on the use of clinical MRI equipment not only for diagnosis but for therapy [9]. This idea consists of two main facts: Magnetic Resonance Imaging can cause focal heating [10], and the differentiation in resonant frequency between healthy and cancer cells [11]. To produce only heating in cancer cells when the whole body is irradiated, it is necessary to determine the specific resonant frequency of the target, using the information contained in the spectra of the area of interest. Then, special RF pulse sequence is applied to produce fast excitation and relaxation mechanism that generates temperature increase of the tumor, causing cellular death or metabolism malfunction that stops cellular division