999 resultados para Obturator maxillary
Resumo:
Obturators and facial prostheses are important not only in rehabilitation and aesthetics, but also in patient re-socialisation. The level of reintegration is directly related to the degree of satisfaction with rehabilitation. So, the maxillofacial prosthetics must provide patient satisfaction during treatment. This study aimed to search information in database and conduct a literature review on patient satisfaction with maxillofacial prosthesis. The problems experienced by these patients may decrease when specialists keep the patient on regular inspection. Rehabilitation through alloplasty or prosthetic restoration provides satisfactory conditions in aesthetics and well-being and reinstates individuals in familial and social environment. (C) 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
The hybrid obturator prosthesis aims to provide a sense of well-being to the patient, offering improvements in speech, chewing, and swallowing. Thus, the retention and stabilization of the prosthesis become decisive factors for the success of the rehabilitation treatment. The objective of this study was to describe the treatment of a 70-year-old man with a congenital maxillary cleft performed through aesthetic and functional prosthetic rehabilitation with hybrid obturator prosthesis. In this study, the fabricated prosthesis achieved its purpose by providing adequate functional and aesthetic conditions to the patient, promoting the reduction of airspace through the sealing of the oronasal communication, with consequent improvement in the quality of life. Copyright © 2013 by Mutaz B. Habal, MD.
Resumo:
Patient perspectives on the treatment options for maxillary defects, which include free tissue transfers or obturator prostheses, may help eliminate current uncertainty as to the best choice of treatment plan. The purpose of this systematic review was to evaluate the quality of life (QoL) of patients with maxillary defects who had undergone restoration with obturator prostheses and/or free tissue transfers. A systematic search of Medline/PubMed and Web of Science databases for articles published before April 2015 was performed by 2 independent reviewers. A manual search of articles published from January 2005 to March 2015 was also conducted. Studies published in English that evaluated the QoL in patients with head and neck cancers were included. The Cohen kappa method was used to calculate inter-reviewer agreement. Ten studies were included. The University of Washington Head and Neck Questionnaire (UW-QOL) was most commonly used to measure QoL. The majority of maxillary defects were Class IIa-b. Two studies reported that the global QoL for patients with obturator prostheses is equivalent to or even better than that of other chronic disease populations. One study revealed no significant difference in QoL when the 2 treatment options were compared. The limited data indicate that the QoL of patients treated with obturator prostheses and that of patients free of tumors is similar. Well-designed clinical studies are necessary to draw definitive conclusions about how obturator prostheses compare with free tissue transfers in terms of affecting patient QoL.
Resumo:
Prosthetic rehabilitation of the midfacial defects has always perplexed prosthodontists. These defects lead to functional and esthetic deficiencies. The purpose of this clinical case report was the presentation of the prosthetic rehabilitation of an extraoral-intraoral defect using two-piece prosthesis magnetically connected. This prosthesis has dramatically improved the patient’s speech, mastication, swallowing, and esthetic.
Resumo:
Statement of problem. The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. Purpose. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. Material and methods. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Results. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. Conclusions. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342)
Resumo:
BACKGROUND: In addition to prosthetic rehabilitation, maxillary defects can also be surgically reconstructed. Soft-tissue reconstruction employs a radial forearm or latissimus dorsi muscle flap, while bony reconstruction can be achieved using a fibula, iliac crest, or scapular flap. Reconstruction using a scapular flap is further divided into two subgroups: the traditional scapular flap with the circumflex scapular artery as the donor vessel and the scapular angle flap with the angular artery originating from the thoracodorsal artery as the donor vessel. MATERIALS AND METHODS: We report on four patients who underwent successful reconstruction with a free scapular angle flap between 2009 and 2011, following maxillary resection due to malignancy. RESULTS: Vertical positioning of the scapular angle flap enables reconstruction of the facial contour, whereas its horizontal alignment and microvascular anastomosis makes a bony reconstruction of the hard palate possible. CONCLUSIONS: The versatility, low rate of donor site morbidity and shape of the scapular angle flap--which resembles that of the hard palate--render it ideal for plastic reconstruction. The suitability of bone quality for dental rehabilitation with implants is a topic of controversial discussion. The scapular angle flap represents an alternative to obturator prosthesis for the reconstruction of maxillary defects ≥ grade I according to Okay et al.
Resumo:
Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning. © 2013 SPIE.
Resumo:
This case report describes the orthodontic treatment of a 32-year-old woman with a Class III malocclusion, whose chief compliant was her dentofacial esthetics. The pretreatment lateral cephalometric tracings showed the presence of a Class III dentoskeletal malocclusion with components of maxillary deficiency. After discussion with the patient, the treatment option included surgically assisted rapid maxillary expansion (SARME) followed by orthopedic protraction (Sky Hook) and Class III elastics. Patient compliance was excellent and satisfactory dentofacial esthetics was achieved after treatment completion.
Resumo:
Bonded maxillary expansion appliances have been suggested to control increases in the vertical dimension of the face after rapid maxillary expansion (RME). However, there is still no consensus in the literature about its real skeletal effects. The purpose of this prospective study was to evaluate, longitudinally, the vertical and sagittal cephalometric alterations after RME performed with bonded maxillary expansion appliance. The sample consisted of 26 children, with a mean age of 8.7 years (range: 6.9-10.9 years), with posterior skeletal crossbite and indication for RME. After maxillary expansion, the bonded appliance was used as a fixed retention for 3.4 months, being replaced by a removable retention subsequently. The cephalometric study was performed onto lateral radiographs, taken before treatment was started, and again 6.3 months after removing the bonded appliance. Intra-group comparison was made using paired t test. The results showed that there were no significant sagittal skeletal changes at the end of treatment. There was a small vertical skeletal increase in five of the eleven evaluated cephalometric measures. The maxilla displaced downward, but it did not modify the facial growth patterns or the direction of the mandible growth. Under the specific conditions of this research, it may be concluded that RME with acrylic bonded maxillary expansion appliance did promote signifciant vertical or sagittal cephalometric alterations. The vertical changes found with the use of the bonded appliance were small and probably transitory, similar to those occurred with the use of banded expansion appliances.
Resumo:
This study evaluated the influence of internal tooth bleaching with 38% hydrogen peroxide (H2O2) on the permeability of the coronal dentin in maxillary anterior teeth and premolars. Seventy teeth (14 per group) were used: central incisors (CI), lateral incisor (LI), canines (C), first premolars (1PM) and second premolars (2PM). Pulp chamber access and transversal sectioning at 2 mm from the cementoenamel junction were performed and the specimens were divided into 2 groups (n= 7): a) no treatment and b) bleaching with 38% H2O2. The bleaching agent was applied to the buccal surface and to the pulp chamber for 10 min. This procedure was repeated 3 times. The specimens were processed histochemically with copper sulfate and rubeanic acid, sectioned longitudinally, and digitalized in a scanner. The area of stained dentin was measured using Image Tool software. Data were analyzed statistically by ANOVA and Tukey's HSD test (?=0.05). There was statistically significant difference (p<0.001) among the untreated groups, CI (0.23 ± 0.26) having the lowest permeability and LI (10.14 ± 1.89) the highest permeability. Among the bleached groups, dentin permeability was increased in all groups of teeth except for 2PM. It may be concluded that bleaching with 38% H2O2 affected dentin permeability near the pulp chamber in maxillary anterior teeth and in first and second premolars.
Resumo:
Patients using obturator prostheses often present denture-induced stomatitis. In order to detect the presence of oral Candida albicans in patients with oronasal communications and to evaluate the effectiveness of a topical antifungal treatment, cytological smears obtained from the buccal and palatal mucosa of 10 adult patients, and from the nasal acrylic surface of their obturator prostheses were examined. A therapeutic protocol comprising the use of oral nystatin (Mycostatin®) and prosthesis disinfection with sodium hypochlorite was prescribed for all patients. Seven patients were positive for C. albicans in the mucosa, with 1 negative result for the prosthetic surface in this group of patients. Post-treatment evaluation revealed the absence of C. albicans on prosthesis surface and on the oral mucosa of all patients. The severity of the candidal infection was significantly higher in the palatal mucosa than in the buccal mucosa, but similar in the palatal mucosa and prosthesis surface, indicating that the mucosa underlying the prosthesis is more susceptible to infection. The therapeutic protocol was effective in all cases, which emphasizes the need for denture disinfection in order to avoid reinfection of the mucosa.
Resumo:
This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP), and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA) and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA). The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP), with a 20º variation of the horizontal angle (GM) and 25º variation of the horizontal angle combined with 15º vertical angle (GMV). Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV) to dissociate maxillary premolar roots in both radiography systems.