991 resultados para OGC SOS specification


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presentación de gvSIG Mobile Sensor, que integra la tecnología SOS (Sensor Observation Service) en los dispositivos móviles a partir de una nueva extensión de gvSIG Mobile. Esta funcionalidad almacena las peticiones SOS en plantillas, representado a los distintos sensores registrados. Las plantillas sirven para transformar los datos obtenidos por el sensor en un instante dado, en peticiones de inserción de observación válidas para el servicio SOS-T

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El protocolo SOS (Sensor Observation Service) es una especificación OGC dentro de la iniciativa Sensor Web Enablement (SWE), que permite acceder a las observaciones y datos de sensores heterogéneos de una manera estándar. En el proyecto gvSIG se ha abierto una línea de investigación entorno a la SWE, existiendo en la actualidad dos prototipos de clientes SOS para gvSIG y gvSIG Mobile. La especificación utilizada para describir las medidas proporcionadas por sensores es Observation & Measurement (O&M) y la descripción de los metadatos de los sensores (localización. ID, fenómenos medidos, procesamiento de los datos, etc) se obtiene a partir del esquema Sensor ML. Se ha implementado el siguiente conjunto de operaciones: GetCapabilities para la descripción del servicio; DescribeSensor para acceder a los metadatos del sensor y el GetObservation para recibir las observaciones. En el caso del prototipo para gvSIG escritorio se puede acceder a los datos procedentes de los distintos grupos de sensores “offerings” añadiéndolos en el mapa como nuevas capas. Los procedimientos o sensores que están incluidos en un “offering” son presentados como elementos de la capa que se pueden cartografiar en el mapa. Se puede acceder a las observaciones (GetObservation) de estos sensores filtrando los datos por intervalo de tiempo y propiedad del fenómeno observado. La información puede ser representada sobre el mapa mediante gráficas para una mejor comprensión con la posibilidad de comparar datos de distintos sensores. En el caso del prototipo para el cliente móvil gvSIG Mobile, se ha utilizado la misma filosofía que para el cliente de escritorio, siendo cada “offering” una nueva capa. Las observaciones de los sensores pueden ser visualizadas en la pantalla del dispositivo móvil y se pueden obtener mapas temáticos,con el objetivo de facilitar la interpretación de los datos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loebl, Komlos, and Sos conjectured that if at least half the vertices of a graph G have degree at least some k is an element of N, then every tree with at most k edges is a subgraph of G. We prove the conjecture for all trees of diameter at most 5 and for a class of caterpillars. Our result implies a bound on the Ramsey number r( T, T') of trees T, T' from the above classes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important recent improvements in cardiology is the use of ventricular assist devices (VADs) to help patients with severe heart diseases, especially when they are indicated to heart transplantation. The Institute Dante Pazzanese of Cardiology has been developing an implantable centrifugal blood pump that will be able to help a sick human heart to keep blood flow and pressure at physiological levels. This device will be used as a totally or partially implantable VAD. Therefore, an improvement on device performance is important for the betterment of the level of interaction with patient`s behavior or conditions. But some failures may occur if the device`s pumping control does not follow the changes in patient`s behavior or conditions. The VAD control system must consider tolerance to faults and have a dynamic adaptation according to patient`s cardiovascular system changes, and also must attend to changes in patient conditions, behavior, or comportments. This work proposes an application of the mechatronic approach to this class of devices based on advanced techniques for control, instrumentation, and automation to define a method for developing a hierarchical supervisory control system that is able to perform VAD control dynamically, automatically, and securely. For this methodology, we used concepts based on Bayesian network for patients` diagnoses, Petri nets to generate a VAD control algorithm, and Safety Instrumented Systems to ensure VAD system security. Applying these concepts, a VAD control system is being built for method effectiveness confirmation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a model of specification-based testing of interactive systems. This model provides the basis for a framework to guide such testing. Interactive systems are traditionally decomposed into a functionality component and a user interface component; this distinction is termed dialogue separation and is the underlying basis for conceptual and architectural models of such systems. Correctness involves both proper behaviour of the user interface and proper computation by the underlying functionality. Specification-based testing is one method used to increase confidence in correctness, but it has had limited application to interactive system development to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Randomized trials that studied clinical outcomes after percutaneous coronary intervention (PCI) with bare metal stenting versus coronary artery bypass grafting (CABG) are underpowered to properly assess safety end points like death, stroke, and myocardial infarction. Pooling data from randomized controlled trials increases the statistical power and allows better assessment of the treatment effect in high-risk subgroups. Methods and Results-We performed a pooled analysis of 3051 patients in 4 randomized trials evaluating the relative safety and efficacy of PCI with stenting and CABG at 5 years for the treatment of multivessel coronary artery disease. The primary end point was the composite end point of death, stroke, or myocardial infarction. The secondary end point was the occurrence of major adverse cardiac and cerebrovascular accidents, death, stroke, myocardial infarction, and repeat revascularization. We tested for heterogeneities in treatment effect in patient subgroups. At 5 years, the cumulative incidence of death, myocardial infarction, and stroke was similar in patients randomized to PCI with stenting versus CABG (16.7% versus 16.9%, respectively; hazard ratio, 1.04, 95% confidence interval, 0.86 to 1.27; P = 0.69). Repeat revascularization, however, occurred significantly more frequently after PCI than CABG (29.0% versus 7.9%, respectively; hazard ratio, 0.23; 95% confidence interval, 0.18 to 0.29; P<0.001). Major adverse cardiac and cerebrovascular events were significantly higher in the PCI than the CABG group (39.2% versus 23.0%, respectively; hazard ratio, 0.53; 95% confidence interval, 0.45 to 0.61; P<0.001). No heterogeneity of treatment effect was found in the subgroups, including diabetic patients and those presenting with 3-vessel disease. Conclusions-In this pooled analysis of 4 randomized trials, PCI with stenting was associated with a long-term safety profile similar to that of CABG. However, as a result of persistently lower repeat revascularization rates in the CABG patients, overall major adverse cardiac and cerebrovascular event rates were significantly lower in the CABG group at 5 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test templates and a test template framework are introduced as useful concepts in specification-based testing. The framework can be defined using any model-based specification notation and used to derive tests from model-based specifications-in this paper, it is demonstrated using the Z notation. The framework formally defines test data sets and their relation to the operations in a specification and to other test data sets, providing structure to the testing process. Flexibility is preserved, so that many testing strategies can be used. Important application areas of the framework are discussed, including refinement of test data, regression testing, and test oracles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Meta-analysis is increasingly being employed as a screening procedure in large-scale association studies to select promising variants for follow-up studies. However, standard methods for meta-analysis require the assumption of an underlying genetic model, which is typically unknown a priori. This drawback can introduce model misspecifications, causing power to be suboptimal, or the evaluation of multiple genetic models, which augments the number of false-positive associations, ultimately leading to waste of resources with fruitless replication studies. We used simulated meta-analyses of large genetic association studies to investigate naive strategies of genetic model specification to optimize screenings of genome-wide meta-analysis signals for further replication. Methods Different methods, meta-analytical models and strategies were compared in terms of power and type-I error. Simulations were carried out for a binary trait in a wide range of true genetic models, genome-wide thresholds, minor allele frequencies (MAFs), odds ratios and between-study heterogeneity (tau(2)). Results Among the investigated strategies, a simple Bonferroni-corrected approach that fits both multiplicative and recessive models was found to be optimal in most examined scenarios, reducing the likelihood of false discoveries and enhancing power in scenarios with small MAFs either in the presence or in absence of heterogeneity. Nonetheless, this strategy is sensitive to tau(2) whenever the susceptibility allele is common (MAF epsilon 30%), resulting in an increased number of false-positive associations compared with an analysis that considers only the multiplicative model. Conclusion Invoking a simple Bonferroni adjustment and testing for both multiplicative and recessive models is fast and an optimal strategy in large meta-analysis-based screenings. However, care must be taken when examined variants are common, where specification of a multiplicative model alone may be preferable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past years, component-based software engineering has become an established paradigm in the area of complex software intensive systems. However, many techniques for analyzing these systems for critical properties currently do not make use of the component orientation. In particular, safety analysis of component-based systems is an open field of research. In this chapter we investigate the problems arising and define a set of requirements that apply when adapting the analysis of safety properties to a component-based software engineering process. Based on these requirements some important component-oriented safety evaluation approaches are examined and compared.