996 resultados para Noninvasive monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The fecal neutrophil-derived proteins calprotectin and lactoferrin have proven useful surrogate markers of intestinal inflammation. The aim of this study was to compare fecal calprotectin and lactoferrin concentrations to clinically, endoscopically, and histologically assessed Crohn’s disease (CD) activity, and to explore the suitability of these proteins as surrogate markers of mucosal healing during anti-TNFα therapy. Furthermore, we studied changes in the number and expression of effector and regulatory T cells in bowel biopsy specimens during anti-TNFα therapy. Patients and methods: Adult CD patients referred for ileocolonoscopy (n=106 for 77 patients) for various reasons were recruited (Study I). Clinical disease activity was assessed with the Crohn’s disease activity index (CDAI) and endoscopic activity with both the Crohn’s disease index of severity (CDEIS) and the simple endoscopic score for Crohn’s disease (SES-CD). Stool samples for measurements of calprotectin and lactoferrin, and blood samples for CRP were collected. For Study II, biopsy specimens were obtained from the ileum and the colon for histologic activity scoring. In prospective Study III, after baseline ileocolonoscopy, 15 patients received induction with anti-TNFα blocking agents and endoscopic, histologic, and fecal-marker responses to therapy were evaluated at 12 weeks. For detecting changes in the number and expression of effector and regulatory T cells, biopsy specimens were taken from the most severely diseased lesions in the ileum and the colon (Study IV). Results: Endoscopic scores correlated significantly with fecal calprotectin and lactoferrin (p<0.001). Both fecal markers were significantly lower in patients with endoscopically inactive than with active disease (p<0.001). In detecting endoscopically active disease, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for calprotectin ≥200 μg/g were 70%, 92%, 94%, and 61%; for lactoferrin ≥10 μg/g they were 66%, 92%, 94%, and 59%. Accordingly, the sensitivity, specificity, PPV, and NPV for CRP >5 mg/l were 48%, 91%, 91%, and 48%. Fecal markers were significantly higher in active colonic (both p<0.001) or ileocolonic (calprotectin p=0.028, lactoferrin p=0.004) than in ileal disease. In ileocolonic or colonic disease, colon histology score correlated significantly with fecal calprotectin (r=0.563) and lactoferrin (r=0.543). In patients receiving anti-TNFα therapy, median fecal calprotectin decreased from 1173 μg/g (range 88-15326) to 130 μg/g (13-1419) and lactoferrin from 105.0 μg/g (4.2-1258.9) to 2.7 μg/g (0.0-228.5), both p=0.001. The relation of ileal IL-17+ cells to CD4+ cells decreased significantly during anti-TNF treatment (p=0.047). The relation of IL-17+ cells to Foxp3+ cells was higher in the patients’ baseline specimens than in their post-treatment specimens (p=0.038). Conclusions: For evaluation of CD activity, based on endoscopic findings, more sensitive surrogate markers than CDAI and CRP were fecal calprotectin and lactoferrin. Fecal calprotectin and lactoferrin were significantly higher in endoscopically active disease than in endoscopic remission. In both ileocolonic and colonic disease, fecal markers correlated closely with histologic disease activity. In CD, these neutrophil-derived proteins thus seem to be useful surrogate markers of endoscopic activity. During anti-TNFα therapy, fecal calprotectin and lactoferrin decreased significantly. The anti-TNFα treatment was also reflected in a decreased IL-17/Foxp3 cell ratio, which may indicate improved balance between effector and regulatory T cells with treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We conducted a pilot study on 10 patients undergoing general surgery to test the feasibility of diffuse reflectance spectroscopy in the visible wavelength range as a noninvasive monitoring tool for blood loss during surgery. Ratios of raw diffuse reflectance at wavelength pairs were tested as a first-pass for estimating hemoglobin concentration. Ratios can be calculated easily and rapidly with limited post-processing, and so this can be considered a near real-time monitoring device. We found the best hemoglobin correlations were when ratios at isosbestic points of oxy- and deoxyhemoglobin were used, specifically 529/500 nm. Baseline subtraction improved correlations, specifically at 520/509 nm. These results demonstrate proof-of-concept for the ability of this noninvasive device to monitor hemoglobin concentration changes due to surgical blood loss. The 529/500 nm ratio also appears to account for variations in probe pressure, as determined from measurements on two volunteers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Traditionally, non-invasive monitoring of tidal volume in infants has been performed using impedance plethysmography analyzed using a one or two compartment model. We developed a new laser system for use in infants, which measures antero-posterior movement of the chest wall during quiet sleep. In 24 unsedated or sedated infants (11 healthy, 13 with respiratory disease), we examined whether the analysis of thoracoabdominal movement based on a three compartment model could more accurately estimate tidal volume in comparison to V(T) measured at the mouth. Using five laser signals, chest wall movements were measured at the right and left, upper and lower ribcage and the abdomen. Within the tidal volume range from 4.6 to 135.7 ml, a three compartment model showed good short term repeatability and the best agreement with tidal volume measured at mouth (r(2) = 0.86) compared to that of a single compartment model (r(2) = 0.62, P < 0.0001) and a two compartment model (r(2) = 0.82, P < 0.01), particularly in the presence of respiratory disease. Three compartment modeling of a 5 laser thoracoabdominal monitoring permits more accurate estimates of tidal volume in infants and potentially of regional differences of chest wall displacement in future studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tese de mestrado, Neurociências, Faculdade de Medicina, Universidade de Lisboa, 2015

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We verified the relevance of measuring fecal glucocorticoid metabolites (FGM) to assess the stress response of the Syrian hamster. Male and female hamsters (n = 10 each) were submitted to an adrenocorticotropic hormone (ACTH) challenge test, whereas animals in the control group received 0.5 mL of sterile isotonic saline solution. All feces voided by each animal were collected at 4 h intervals from 24 h before (baseline) until 48 h after injections. FGM were quantified using an 11-oxoetiocholanolone enzyme immunoassay (EIA). Basal concentrations of FGM were almost four times higher in males than in females. Following ACTH administration, FGM levels started rising from 8 h onwards, reaching peak concentrations 20 or 28 h post injection in males and females, respectively. Despite the much higher absolute concentrations present in males, the relative increase (500%) in response to the ACTH stimulation was similar in both sexes. Sex differences in FGM levels are in accordance with results reported by others regarding the hamster adrenal physiology. The comparison of the adrenocortical response of males and females to an ACTH challenge provided new information about the amplitude and the timing of such a response and the excretion of glucocorticoids in both sexes. We demonstrated for the first time in the Syrian hamster that adrenocortical activity can be monitored in fecal samples in a noninvasive way. Our study provides a humane, practical, and noninvasive alternative to blood removal and therefore a powerful tool for stress-related studies in a species frequently used as an animal model in medical research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The subject of this thesis is in the area of Applied Mathematics known as Inverse Problems. Inverse problems are those where a set of measured data is analysed in order to get as much information as possible on a model which is assumed to represent a system in the real world. We study two inverse problems in the fields of classical and quantum physics: QCD condensates from tau-decay data and the inverse conductivity problem. Despite a concentrated effort by physicists extending over many years, an understanding of QCD from first principles continues to be elusive. Fortunately, data continues to appear which provide a rather direct probe of the inner workings of the strong interactions. We use a functional method which allows us to extract within rather general assumptions phenomenological parameters of QCD (the condensates) from a comparison of the time-like experimental data with asymptotic space-like results from theory. The price to be paid for the generality of assumptions is relatively large errors in the values of the extracted parameters. Although we do not claim that our method is superior to other approaches, we hope that our results lend additional confidence to the numerical results obtained with the help of methods based on QCD sum rules. EIT is a technology developed to image the electrical conductivity distribution of a conductive medium. The technique works by performing simultaneous measurements of direct or alternating electric currents and voltages on the boundary of an object. These are the data used by an image reconstruction algorithm to determine the electrical conductivity distribution within the object. In this thesis, two approaches of EIT image reconstruction are proposed. The first is based on reformulating the inverse problem in terms of integral equations. This method uses only a single set of measurements for the reconstruction. The second approach is an algorithm based on linearisation which uses more then one set of measurements. A promising result is that one can qualitatively reconstruct the conductivity inside the cross-section of a human chest. Even though the human volunteer is neither two-dimensional nor circular, such reconstructions can be useful in medical applications: monitoring for lung problems such as accumulating fluid or a collapsed lung and noninvasive monitoring of heart function and blood flow.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND.: Urine is a potentially rich source of biomarkers for monitoring kidney dysfunction. In this study, we have investigated the potential of soluble human leukocyte antigen (sHLA)-DR in the urine for noninvasive monitoring of renal transplant patients. METHODS.: Urinary soluble HLA-DR levels were measured by sandwich enzyme-linked immunosorbent assay in 103 patients with renal diseases or after renal transplantation. sHLA-DR in urine was characterized by Western blotting and mass spectrometry. RESULTS.: Acute graft rejection was associated with a significantly elevated level of urinary sHLA-DR (P<0.0001), compared with recipients with stable graft function or healthy individuals. A receiver operating characteristic curve analysis showed the area under the curve to be 0.88 (P<0.001). At a selected threshold, the sensitivity was 80% and specificity was 98% for detection of acute renal transplant rejection. sHLA-DR was not exosomally associated and was of lower molecular weight compared with the HLA-DR expressed as heterodimer on the plasma membrane of antigen-presenting cells. CONCLUSIONS.: sHLA-DR excreted into urine is a promising indicator of renal transplant rejection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND The correlation between noninvasive markers with endoscopic activity according to the modified Baron Index in patients with ulcerative colitis (UC) is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), hemoglobin, platelets, blood leukocytes, and the Lichtiger Index (clinical score). METHODS UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically. Samples from feces and blood were analyzed in UC patients and controls. RESULTS We enrolled 228 UC patients and 52 healthy controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), platelets (r = 0.488), blood leukocytes (r = 0.401), and hemoglobin (r = -0.388). FC was the only marker that could discriminate between different grades of endoscopic activity (grade 0, 16 [10-30] μg/g; grade 1, 35 [25-48] μg/g; grade 2, 102 [44-159] μg/g; grade 3, 235 [176-319] μg/g; grade 4, 611 [406-868] μg/g; P < 0.001 for discriminating the different grades). FC with a cutoff of 57 μg/g had a sensitivity of 91% and a specificity of 90% to detect endoscopically active disease (modified Baron Index ≥ 2). CONCLUSIONS FC correlated better with endoscopic disease activity than clinical activity, CRP, platelets, hemoglobin, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Propõe-se método novo e completo para análise de acetona em ar exalado envolvendo coleta com pré-concentração em água, derivatização química e determinação eletroquímica assistida por novo algoritmo de processamento de sinais. Na literatura recente a acetona expirada vem sendo avaliada como biomarcador para monitoramento não invasivo de quadros clínicos como diabetes e insuficiência cardíaca, daí a importância da proposta. Entre as aminas que reagem com acetona para formar iminas eletroativas, estudadas por polarografia em meados do século passado, a glicina apresentou melhor conjunto de características para a definição do método de determinação por voltametria de onda quadrada sem a necessidade de remoção de oxigênio (25 Hz, amplitude de 20 mV, incremento de 5 mV, eletrodo de gota de mercúrio). O meio reacional, composto de glicina (2 mol·L-1) em meio NaOH (1 mol·L-1), serviu também de eletrólito e o pico de redução da imina em -1,57 V vs. Ag|AgCl constituiu o sinal analítico. Para tratamento dos sinais, foi desenvolvido e avaliado um algoritmo inovador baseado em interpolação de linha base por ajuste de curvas de Bézier e ajuste de gaussiana ao pico. Essa combinação permitiu reconhecimento e quantificação de picos relativamente baixos e largos sobre linha com curvatura acentuada e ruído, situação em que métodos convencionais falham e curvas do tipo spline se mostraram menos apropriadas. A implementação do algoritmo (disponível em http://github.com/batistagl/chemapps) foi realizada utilizando programa open source de álgebra matricial integrado diretamente com software de controle do potenciostato. Para demonstrar a generalidade da extensão dos recursos nativos do equipamento mediante integração com programação externa em linguagem Octave (open source), implementou-se a técnica da cronocoulometria tridimensional, com visualização de resultados já tratados em projeções de malha de perspectiva 3D sob qualquer ângulo. A determinação eletroquímica de acetona em fase aquosa, assistida pelo algoritmo baseado em curvas de Bézier, é rápida e automática, tem limite de detecção de 3,5·10-6 mol·L-1 (0,2 mg·L-1) e faixa linear que atende aos requisitos da análise em ar exalado. O acetaldeído, comumente presente em ar exalado, em especial, após consumo de bebidas alcoólicas, dá origem a pico voltamétrico em -1,40 V, contornando interferência que prejudica vários outros métodos publicados na literatura e abrindo possibilidade de determinação simultânea. Resultados obtidos com amostras reais são concordantes com os obtidos por método espectrofotométrico, em uso rotineiro desde o seu aperfeiçoamento na dissertação de mestrado do autor desta tese. Em relação à dissertação, também se otimizou a geometria do dispositivo de coleta, de modo a concentrar a acetona num volume menor de água gelada e prover maior conforto ao paciente. O método completo apresentado, englobando o dispositivo de amostragem aperfeiçoado e o novo e efetivo algoritmo para tratamento automático de sinais voltamétricos, está pronto para ser aplicado. Evolução para um analisador portátil depende de melhorias no limite de detecção e facilidade de obtenção eletrodos sólidos (impressos) com filme de mercúrio, vez que eletrodos de bismuto ou diamante dopado com boro, entre outros, não apresentaram resposta.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Understanding arterial distensibility has shown to be important in the pathogenesis of cardiovascular abnormalities like hypertension. It is also known that arterial pulse wave velocity (PWV) is a measure of the elasticity or stiffness of peripheral arterial blood vessels. However, it generally requires complex instrumentations to have an accurate measurement and not suited for continual monitoring. In this paper, it describes a simple and non-intrusive method to detect the cardiovascular pulse from a human wrist above the radial artery and a fingertip. The main components of this proposed method are a piezoelectric transducer and a photo-plethysmography circuitry. 5 healthy adults (4 male) with age ranging from 25 to 38 years were recruited. The timing consistency of the detected pulsations is first evaluated and compared to that obtained from a commercial electrocardiogram. Furthermore, the derived PWV is then assessed by the predicted values attained from regression equations of two previous similar studies. The results show good correlations (p < 0.05) and similarities for the former and latter respectively. The simplicity and non-invasive nature of the proposed method can be attractive for even younger or badly disturbed patients. Moreover, it can be used for prolonged monitoring for the comfort of the patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Trials of new technologies to remotely monitor for signs and symptoms of worsening heart failure are continually emerging. The extent to which technological differences impact the effectiveness of non-invasive remote monitoring for heart failure management is unknown. Objective To examine the effect of specific technology used for non-invasive remote monitoring of people with heart failure on all-cause mortality and heart failure-related hospitalisations. Methods A sub-analysis of a large systematic review and meta-analysis was conducted. Studies were stratified according to the specific type of technology used and separate meta-analyses were performed. Four different types of non-invasive remote monitoring technologies were identified including structured telephone calls, videophone, interactive voice response devices and telemonitoring. Results Only structured telephone calls and telemonitoring were effective in reducing the risk of all-cause mortality (RR 0.87; 95% CI=0.75-1.01; p=0.06 and 0.62; 95% CI=0.50-0.77; p<0.0001) and heart failure-related hospitalisations (RR 0.77; 95% CI=0.68-0.87; p<0.001) and 0.75; 95% CI=0.63-0.91; p=0.003). More research data is required for videophone and interactive voice response technologies. Conclusions This sub-analysis identified that only two of the four specific technologies used for non-invasive remote monitoring in heart failure improved outcomes. When results of studies that involved these disparate technologies were combined in previous meta-analyses, significant improvements in outcomes were identified. As such, this study has highlighted implications for future meta-analyses of randomised controlled trials focused on evaluating the effectiveness of remote monitoring in heart failure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Water held in the unsaturated zone is important for agriculture and construction and is replenished by infiltrating rainwater. Monitoring the soil water content of clay soils using ground-penetrating radar (GPR) has not been researched, as clay soils cause attenuation of GPR signal. In this study, GPR common-midpoint soundings (CMPs) are used in the clayey soils of the Miller Run floodplain to monitor changes in the soil water content (SWC) before and after rainfall events. GPR accomplishes this task because increases in water content will increase the dielectric constant of the subsurface material, and decrease the velocity of the GPR wave. Using an empirical relationship between dielectric constant and SWC, the Topp relation, we are able to calculate a SWC from these velocity measurements. Non-invasive electromagnetics, resistivity, and seismic were performed, and from these surveys, the layering at the field site was delineated. EM characterized the horizontal variation of the soil, allowing us to target the most clay rich area. At the CMP location, resistivity indicates the vertical structure of the subsurface consists of a 40 cm thick layer with a resistivity of 100 ohm*m. Between 40 cm and 1.5 m is a layer with a resistivity of 40 ohm*m. The thickness estimates were confirmed with invasive auger and trenching methods away from the CMP location. GPR CMPs were collected relative to a July 2013 and September 2013 storm. The velocity observations from the CMPs had a precision of +/- 0.001 m/ns as assessed by repeat analysis. In the case of both storms, the GPR data showed the expected relationship between the rainstorms and calculated SWC, with the SWC increasing sharply after the rainstorm and decreasing as time passed. We compared these data to auger core samples collected at the same time as the CMPs were taken, and the volumetric analysis of the cores confirmed the trend seen in the GPR, with SWC values between 3 and 5 percent lower than the GPR estimates. Our data shows that we can, with good precision, monitor changes in the SWC of conductive soils in response to rainfall events, despite the attenuation induced by the clay.