998 resultados para Noninvasive methods
Resumo:
The Amazonian manatee (Trichechus inunguis) is endemic in the Amazonian basin and is the only exclusively fresh water sirenian. Historically hunted on a large scale, this species is now considered endangered, and Studies on the reproductive physiology are critical for the improvement of reproductive management of captive and wild Populations of manatees. The aim of this Study was to verify the viability of androgen measurement in saliva, lacrimal, urine, and fecal samples of the Amazonian manatee by conducting a hormone challenge. Two adult male manatees (A-1 and A-2) were Submitted to an experimentation protocol of 12 day (D1 to D10). On D0, the animals received an intramuscular injection of gonadotropin-releasing hormone (GnRH)-analogue. Salivary, lacrimal, urinary, and fecal samples were collected daily (between 0800 hours and 0900 hours) and frozen at -20 degrees C until assayed. Fecal samples were lyophilized, extracted with 80% methanol, and diluted in buffer before the radioimmunoassay (RIA). Urine samples underwent acid hydrolysis and were diluted in depleted bovine serum. Salivary and lacrimal samples were assayed without the extraction step. Hormonal assays were conducted with a commercial testosterone RIA kit. An androgen peak (>median + 2 interquartile range [IQR]) was observed in all matrices of both animals, although it was less prominent in the lacrimal samples of A-2. However, the fecal androgen peak (A-1 peak = 293.78 ng/g dry feces, median [IQR] = 143.58 [32.38] ng/g dry feces; A-2 peak = 686.72 ng/g dry feces, median [IQR] = 243.82 [193.16] ng/g dry feces) occurred later than urinary (A-1 peak = 648.16 ng/mg creatinine [Cr], median [IQR] = 23.88 [30.44] ng/mg Cr; A-2 peak = 370.44 ng/mg Cr, median [IQR] = 113.87 [117.73] ng/mg Cr) and salivary (A-1 peak = 678.89 pg/ml, median [IQR] = 103.69 [119.86] pg/ml; A-2 peak = 733.71 pg/ml, median [IQR] = 262.92 [211.44] pg/ml) androgen peaks. These intervals appear to be correlated with the long digesta passage time in this species. The salivary and urinary peaks were closely associated. These results demonstrate that androgen concentrations in saliva, urine, or feces samples reflect reliably physiologic events and are a powerful tool for noninvasive reproductive monitoring of Amazonian manatees.
Resumo:
OBJECTIVE: To determine the predictive values of noninvasive tests for the detection of allograft vascular disease. METHODS: We studied 39 patients with mean ages of 48±13 years and a follow-up period of 86±13 months. The diagnosis of allograft vascular disease was made by cine-coronary arteriography, and it was considered as positive if lesions existed that caused > or = 50% obstruction of the lumen. Patients underwent 24h Holter monitoring, thallium scintigraphy, a treadmill stress test, and dobutamine stress echocardiography. Sensitivity, specificity, and positive and negative predictive values were determined in percentages for each method, as compared with the cine-coronary arteriography results. RESULTS: Allograft vascular disease was found in 15 (38%) patients. The Holter test showed 15.4% sensitivity, 95.5% specificity. For the treadmill stress test, sensitivity was 10%, specificity was 100%. When thallium scintigraphy was used, sensitivity was 40%, specificity 95.8%. On echocardiography with dobutamine, we found a 63.6% sensitivity, 91.3% specificity. When the dobutamine echocardiogram was associated with scintigraphy, sensitivity was 71.4%, specificity was 87%. CONCLUSION: In this group of patients, the combination of two noninvasive methods (dobutamine echocardiography and thallium scintigraphy) may be a good alternative for the detection of allograft vascular disease in asymptomatic patients with normal ventricular function.
Resumo:
Foram comparados dois métodos não-invasivos de medida da pressão arterial, o Doppler vascular e o oscilométrico, com o objetivo de estabelecer parâmetros que possam auxiliar no diagnóstico seguro da hipertensão arterial. Para tal, foram utilizados 45 cães, machos e fêmeas, distribuídos em três grupos de acordo com o peso, pequeno, médio e grande porte. Em cada animal, procedeu-se a mensuração por meio do Doppler vascular e, em seguida, do oscilométrico. Na obtenção da pressão arterial sistólica, não houve diferença entre os métodos nos três grupos de animais, porém, na obtenção da pressão arterial diastólica, houve diferença estatística entre o Doppler vascular e o oscilométrico nos grupos de animais de pequeno e médio porte. Pôde-se concluir que valores confiáveis de pressão sistólica podem ser obtidos tanto por meio do Doppler vascular quanto do oscilométrico. Os valores da pressão arterial diastólica obtidos pelos dois métodos não se correlacionam, principalmente nos animais de pequeno e médio porte.
Resumo:
Background We validated a strategy for diagnosis of coronary artery disease ( CAD) and prediction of cardiac events in high-risk renal transplant candidates ( at least one of the following: age >= 50 years, diabetes, cardiovascular disease). Methods A diagnosis and risk assessment strategy was used in 228 renal transplant candidates to validate an algorithm. Patients underwent dipyridamole myocardial stress testing and coronary angiography and were followed up until death, renal transplantation, or cardiac events. Results The prevalence of CAD was 47%. Stress testing did not detect significant CAD in 1/3 of patients. The sensitivity, specificity, and positive and negative predictive values of the stress test for detecting CAD were 70, 74, 69, and 71%, respectively. CAD, defined by angiography, was associated with increased probability of cardiac events [log-rank: 0.001; hazard ratio: 1.90, 95% confidence interval (CI): 1.29-2.92]. Diabetes (P=0.03; hazard ratio: 1.58, 95% CI: 1.06-2.45) and angiographically defined CAD (P=0.03; hazard ratio: 1.69, 95% CI: 1.08-2.78) were the independent predictors of events. Conclusion The results validate our observations in a smaller number of high-risk transplant candidates and indicate that stress testing is not appropriate for the diagnosis of CAD or prediction of cardiac events in this group of patients. Coronary angiography was correlated with events but, because less than 50% of patients had significant disease, it seems premature to recommend the test to all high-risk renal transplant candidates. The results suggest that angiography is necessary in many high-risk renal transplant candidates and that better noninvasive methods are still lacking to identify with precision patients who will benefit from invasive procedures. Coron Artery Dis 21: 164-167 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
Background. Heart transplantation (OHT) has traditionally been contraindicated in the presence of severe pulmonary hypertension (PH), as detected by right heart catheterization. Noninvasive methods are still not reliably accurate to make this evaluation. Objectives. Determine the efficacy of echo Doppler analysis for the diagnosis of severe PH. Methods. One hundred thirty patients (mean age = 42 +/- 15 years, 82 men) showed severe left ventricular dysfunction (mean ejection fraction = 29 +/- 12%; functional class III-IV). We excluded patients with atrial fibrillation, heart failure secondary to congenital disease, and valvulopathy. The pulmonary parameters defined as severe PH were: systolic pulmonary artery pressure (sPAP) >= 60 mm Hg; a mean transpulmonary gradient >= 15; or pulmonary vascular resistance >= 5 Wood units. Patients underwent a right heart catheterization using a Swan-Ganz catheter to measure hemodynamic parameters and to noninvasively estimate right-sided pressures from spectral Doppler recordings of tricuspid regurgitation velocity (right ventricular systolic pressure [RVsP]). A Pearson correlation of sPAP was obtained with RVsP by; the sensitivity of RVsP for the diagnosis of PH was determined by a receiver operating characteristic (ROC) curve. Results. A good correlation between sPAP and RVsP was obtained by Pearson correlation analysis (r = 0.64; 95% confidence interval [CI] 0.50-0.75; P < .001). The ROC curve analysis showed a sensitivity of 100%, a specificity of 37.2%, (95% CI 0.69-0.83, P < .0001) of a RVsP < 45 mm Hg (cutoff) on the exclusion of severe PH. Conclusions. The cutoff of RVsP < 45 mm Hg, on noninvasive echo Doppler evaluation of PH is an efficient method to replace invasive heart catheterization in OHT candidates.
Resumo:
Urine is an ideal source of materials to search for potential disease-related biomarkers as it is produced by the affected tissues and can be easily obtained by noninvasive methods. 2-DE-based proteomic approach was used to better understand the molecular mechanisms of injury induced by fluoride (F(-)) and define potential biomarkers of dental fluorosis. Three groups of weanling male Wistar rats were treated with drinking water containing 0 (control), 5, or 50 ppm F(-) for 60 days (n = 15/group). During the experimental period, the animals were kept individually in metabolic cages, to analyze the water and food consumption, as well as fecal and urinary F excretion. Urinary proteome profiles were examined using 2-DE and Colloidal Coomassie Brilliant Blue staining. A dose-response regarding F(-) intake and excretion was detected. Quantitative intensity analysis revealed 8, 11, and 8 significantly altered proteins between control vs. 5 ppm F(-), control vs. 50 ppm F(-) and 5 ppm F(-) vs. 50 ppm F(-) groups, respectively. Two proteins regulated by androgens (androgen-regulated 20-KDa protein and 0c-2,1-globulin) and one related to detoxification (aflatoxin-Bl-aldehyde-reductase) were identified by MALDI-TOF-TOF MS/MS. Thus, proteomic analysis can help to better understand the mechanisms underlying F(-) toxicity, even in low doses. 2010 Wiley Periodicals, Inc. J Biochem Mol Toxicol 25:8-14, 2011; View this article online at wileyonlinelibrary.com. DOI 10:1002/jbt.20353
Resumo:
Bone histomorphometry is defined as a quantitative evaluation of bone micro architecture, remodelling and metabolism. Bone metabolic assessment is based on a dynamic process, which provides data on bone matrix formation rate by incorporating a tetracycline compound. In the static evaluation, samples are stained and a semi-automatic technique is applied in order to obtain bone microarchitectural parameters such as trabecular area, perimeter and width. These parameters are in 2D, but they can be extrapolated into 3D, applying a stereological formula. Histomorphometry can be applied to different areas; however, in recent decades it has been a relevant tool in monitoring the effect of drug administration in bone. The main challenge for the future will be the development of noninvasive methods that can give similar information. In the herein review paper we will discuss the general principles and main applications of bone histomorphometry.
Resumo:
Neural signatures of humans' movement intention can be exploited by future neuroprosthesis. We propose a method for detecting self-paced upper limb movement intention from brain signals acquired with both invasive and noninvasive methods. In the first study with scalp electroencephalograph (EEG) signals from healthy controls, we report single trial detection of movement intention using movement related potentials (MRPs) in a frequency range between 0.1 to 1 Hz. Movement intention can be detected above chance level (p<0.05) on average 460 ms before the movement onset with low detection rate during the on-movement intention period. Using intracranial EEG (iEEG) from one epileptic subject, we detect movement intention as early as 1500 ms before movement onset with accuracy above 90% using electrodes implanted in the bilateral supplementary motor area (SMA). The coherent results obtained with non-invasive and invasive method and its generalization capabilities across different days of recording, strengthened the theory that self-paced movement intention can be detected before movement initiation for the advancement in robot-assisted neurorehabilitation.
Resumo:
Animal studies suggest that renal tissue hypoxia plays an important role in the development of renal damage in hypertension and renal diseases, yet human data were scarce due to the lack of noninvasive methods. Over the last decade, blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI), detecting deoxyhemoglobin in hypoxic renal tissue, has become a powerful tool to assess kidney oxygenation noninvasively in humans. This paper provides an overview of BOLD-MRI studies performed in patients suffering from essential hypertension or chronic kidney disease (CKD). In line with animal studies, acute changes in cortical and medullary oxygenation have been observed after the administration of medication (furosemide, blockers of the renin-angiotensin system) or alterations in sodium intake in these patient groups, underlining the important role of renal sodium handling in kidney oxygenation. In contrast, no BOLD-MRI studies have convincingly demonstrated that renal oxygenation is chronically reduced in essential hypertension or in CKD or chronically altered after long-term medication intake. More studies are required to clarify this discrepancy and to further unravel the role of renal oxygenation in the development and progression of essential hypertension and CKD in humans.
Resumo:
Twitch mouth pressure (Pmo,tw) during magnetic phrenic nerve stimulation and sniff nasal inspiratory pressure (SNIP) were recently proposed as alternative noninvasive methods for assessing inspiratory muscle strength. This study aimed to compare their reproducibility with maximal inspiratory pressure (MIP) in normal subjects. Ten healthy subjects were studied at functional residual capacity in semirecumbent position. Cervical magnetic phrenic nerve stimulation was performed during gentle expiration against an occlusion incorporating a small leak. Constancy of stimulation was controlled by recording diaphragmatic electromyogram. Within and between-session reproducibility of pressure were studied for Pmo,tw, SNIP, and MIP. The subjects were studied during a session of 10 manoeuvres repeated after 1 day and 1 month. The mean values were 16 cmH2O for Pmo,tw, 118 cmH2O for SNIP, and 115 cmH2O for MIP. For the three tests, the within subject variation was small in relation to between-subject variation, with the intraclass correlation coefficient ranging 0.79-0.90 for Pmo,tw, 0.85-0.92 for SNIP, and 0.88-0.92 for MIP. At 1 day interval, the coefficient of repeatability (2 SD of differences) was 3.6 cmH2O for Pmo,tw, 32 cmH2O for SNIP and 28 cmH2O for MIP. At 1 month interval, the coefficient of repeatability was 5.8 cmH2O for Pmo,tw, 23 cmH2O for SNIP and 21 cmH2O for MIP. We conclude that the within session reproducibility of the new tests twitch mouth pressure and sniff nasal inspiratory pressure is sufficient to be clinically useful. For sniff nasal inspiratory pressure, the between session reproducibility established after 1 day was maintained after 1 month. For twitch mouth pressure, the between session reproducibility declined slightly after 1 month. These characteristics should be considered when using these methods to follow an individual patient over time.
Resumo:
The purpose of the present study was to identify noninvasive methods to evaluate the severity of iron overload in transfusion-dependent ß-thalassemia and the efficiency of intensive intravenous therapy as an additional tool for the treatment of iron-overloaded patients. Iron overload was evaluated for 26 ß-thalassemia homozygous patients, and 14 of them were submitted to intensive chelation therapy with high doses of intravenous deferoxamine (DF). Patients were classified into six groups of increasing clinical severity and were divided into compliant and non-compliant patients depending on their adherence to chronic chelation treatment. Several methods were used as indicators of iron overload. Total gain of transfusion iron, plasma ferritin, and urinary iron excretion in response to 20 to 60 mg/day subcutaneous DF for 8 to 12 h daily are useful to identify iron overload; however, urinary iron excretion in response to 9 g intravenous DF over 24 h and the increase of urinary iron excretion induced by high doses of the chelator are more reliable to identify different degrees of iron overload because of their correlation with the clinical grades of secondary hemochromatosis and the significant differences observed between the groups of compliant and non-compliant patients. Finally, the use of 3-9 g intravenous DF for 6-12 days led to a urinary iron excretion corresponding to 4.1 to 22.4% of the annual transfusion iron gain. Therefore, continuous intravenous DF at high doses may be an additional treatment for these patients, as a complement to the regular subcutaneous infusion at home, but requires individual planning and close monitoring of adverse reactions.
Resumo:
Medical fields requires fast, simple and noninvasive methods of diagnostic techniques. Several methods are available and possible because of the growth of technology that provides the necessary means of collecting and processing signals. The present thesis details the work done in the field of voice signals. New methods of analysis have been developed to understand the complexity of voice signals, such as nonlinear dynamics aiming at the exploration of voice signals dynamic nature. The purpose of this thesis is to characterize complexities of pathological voice from healthy signals and to differentiate stuttering signals from healthy signals. Efficiency of various acoustic as well as non linear time series methods are analysed. Three groups of samples are used, one from healthy individuals, subjects with vocal pathologies and stuttering subjects. Individual vowels/ and a continuous speech data for the utterance of the sentence "iruvarum changatimaranu" the meaning in English is "Both are good friends" from Malayalam language are recorded using a microphone . The recorded audio are converted to digital signals and are subjected to analysis.Acoustic perturbation methods like fundamental frequency (FO), jitter, shimmer, Zero Crossing Rate(ZCR) were carried out and non linear measures like maximum lyapunov exponent(Lamda max), correlation dimension (D2), Kolmogorov exponent(K2), and a new measure of entropy viz., Permutation entropy (PE) are evaluated for all three groups of the subjects. Permutation Entropy is a nonlinear complexity measure which can efficiently distinguish regular and complex nature of any signal and extract information about the change in dynamics of the process by indicating sudden change in its value. The results shows that nonlinear dynamical methods seem to be a suitable technique for voice signal analysis, due to the chaotic component of the human voice. Permutation entropy is well suited due to its sensitivity to uncertainties, since the pathologies are characterized by an increase in the signal complexity and unpredictability. Pathological groups have higher entropy values compared to the normal group. The stuttering signals have lower entropy values compared to the normal signals.PE is effective in charaterising the level of improvement after two weeks of speech therapy in the case of stuttering subjects. PE is also effective in characterizing the dynamical difference between healthy and pathological subjects. This suggests that PE can improve and complement the recent voice analysis methods available for clinicians. The work establishes the application of the simple, inexpensive and fast algorithm of PE for diagnosis in vocal disorders and stuttering subjects.
Resumo:
Objetivos: Determinar si existe correlación entre las variables SaFiO2 y PaFiO2 de pacientes con patología respiratoria aguda en la unidad de Cuidado Intensivo Pediátrico, en la Fundación Cardioinfantil en la ciudad de Bogotá D.C. Materiales y métodos: Se analizaron las variables cuantitativas con medidas de tendencia central como la media y medidas de dispersión como la desviación estándar. Se utilizó un nivel de confiabilidad del 95% y un poder estimado 80%, para prueba de hipótesis de una proporción. Se realizó un análisis de correlación para medir la fuerza de la relación entre las variables PaO2/FiO2 y SO2/FiO2 a través del coeficiente de correlación. Resultados: Se incluyeron 12 pacientes y se tomaron un total de 65 registros de SO2/FiO2 y PaO2/FiO2 encontrando que existe relación positiva entre las variables SaO2/FIO2 y PaO2/FIO2, la cual es variable dependiendo de la fracción inspirada de oxigeno con el cual se encuentre el paciente. De acuerdo a las observaciones realizadas, la variable SaO2/FIO2 está moderadamente correlacionada (r = 0,602) con la PaO2/FIO2, cuando la FIO2 está entre 0.35 y 0.55; un grado de correlación aceptable (r = 0,319) cuando la FIO2 está entre 0.60 0.80 y 0.81 1 (r = 0,318). Conclusiones: Los métodos no invasivos en la evaluación de la oxigenación podrían ser una alternativa para el seguimiento clínico en niños con lesión pulmonar aguda o síndrome de dificultad respiratorio agudo. Se requiere de estudios analíticos que brinden una mejor evidencia científica que pueda ser extrapolable a la población infantil objeto de este estudio.
Resumo:
Nowadays, noninvasive methods of diagnosis have increased due to demands of the population that requires fast, simple and painless exams. These methods have become possible because of the growth of technology that provides the necessary means of collecting and processing signals. New methods of analysis have been developed to understand the complexity of voice signals, such as nonlinear dynamics aiming at the exploration of voice signals dynamic nature. The purpose of this paper is to characterize healthy and pathological voice signals with the aid of relative entropy measures. Phase space reconstruction technique is also used as a way to select interesting regions of the signals. Three groups of samples were used, one from healthy individuals and the other two from people with nodule in the vocal fold and Reinke`s edema. All of them are recordings of sustained vowel /a/ from Brazilian Portuguese. The paper shows that nonlinear dynamical methods seem to be a suitable technique for voice signal analysis, due to the chaotic component of the human voice. Relative entropy is well suited due to its sensibility to uncertainties, since the pathologies are characterized by an increase in the signal complexity and unpredictability. The results showed that the pathological groups had higher entropy values in accordance with other vocal acoustic parameters presented. This suggests that these techniques may improve and complement the recent voice analysis methods available for clinicians. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
pós-infarto agudo do miocárdio (IAM) têm mostrado baixo valor preditivo positivo quando estudados isoladamente. A possibilidade da Eletrocardiografia Dinâmica de 24 horas (ECGD) fornecer dados referentes a isquemia silenciosa (IS), arritmias ventriculares e modulação autonômica do coração pelo estudo da variabilidade da freqüência cardíaca (VFC), levou o autor a empregar este método em pacientes acometidos de IAM com o objetivo de avaliar se estas três variáveis estariam relacionadas a presença de eventos desfavoráveis em evolução a médio prazo. Material e Métodos – Foram selecionados 91 pacientes acometidos de um primeiro IAM não-complicado e realizados exames de ECGD de 24 h por dois dias consecutivos, antes da alta hospitalar. Os parâmetros pesquisados nos exames foram: isquemia silenciosa, identificação e quantificação de arritmias ventriculares e determinação dos índices de VFC pelos métodos do domínio do tempo e do mapa de retorno tridimensional. Foram considerados como desfechos: re-infarto, angina instável, taquicardia ventricular sustentada e morte. Resultados – No seguimento médio de 27,7 meses (DP=15,45), 23 (25%) dos pacientes apresentaram eventos, sendo nove fatais. Os eventos foram mais freqüentes entre os pacientes que apresentaram extra-sístoles ventriculares ≥10/hora (p=0,01) e também naqueles com IS (p=0,02). Em modelo de análise multifatorial, a presença de dislipidemia elevou o valor preditivo positivo dessas variáveis. Nenhum dos índices de VFC esteve significativamente relacionado ao surgimento de eventos. Conclusões – Em pacientes pós-IAM de baixo risco, a presença de arritmias ventriculares freqüentes ou de isquemia silenciosa está relacionada a um prognóstico desfavorável. O estudo da VFC não mostrou utilidade na estratificação de risco destes pacientes.