931 resultados para Non-therapeutic ventilation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we examine the lawfulness of a proposal to provide elective ventilation to incompetent patients who are potential organ donors. Under the current legal framework, this depends on whether the best interests test could be satisfied. It might be argued that, because the Mental Capacity Act 2005 (UK) (and the common law) makes it clear that the best interests test is not confined to the patient's clinical interests, but extends to include the individual's own values, wishes and beliefs, the proposal will be in the patient's best interests. We reject this claim. We argue that, as things currently stand, the proposal could not lawfully be justified as a blanket proposition by reference to the best interests test. Accordingly, a modification of the law would be necessary to render the proposal lawful. We conclude with a suggestion about how that could be achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The inconsistent definition of non-therapeutic medication omissions, under-reporting, and a poor understanding of their associated factors hamper efforts to improve medication administration practices. Aim: To examine the incidence of non-therapeutic medication omissions among acutely ill medical and surgical adult patients; and to identify the patient-, drug- and system-related predictors of these omissions. Method: A medication chart audit of 288 acutely ill adult medical and surgical patients admitted to 4 target wards (2 surgical and 2 medical) at an Australian hospital. Patients admitted to these wards from December 2008 to November 2009, with at least one regularly prescribed medication, were eligible. The sample was stratified according to gender, season and ward. A medication chart audit identified medication omissions, and data were collected on gender, age, length of stay, comorbidities, medication history and clinical pharmacy review. Results: Of the 288 medication charts audited, 220 (75%) had one or more medication omissions. Of the 15 020 medication administration episodes, there were 1687 omissions, resulting in an omission rate per medication administration episode of 11%. Analgesics and aperients were the most frequently omitted medications, with failure to sign the medication record and patient refusal, the main reasons for omission. Female gender (p < 0.001) and the number of medication administration episodes (p < 0.001) were statistically significant predictors of non-therapeutic medication omissions. Conclusion: The high incidence of medication omissions suggests there is need for an agreed definition of medication omission and its inclusion as a reportable incident. Increasing medication reconciliation via implementation of the Medication Management Plan may also reduce the opportunity for error. J Pharm Pract Res 2011; 41: 188-91.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive ventilation may be a means to temporarily reverse or slow the progression of respiratory failure in cystic fibrosis. To compare the effect of non-invasive ventilation versus no non-invasive ventilation in people with cystic fibrosis. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches, handsearching relevant journals and abstract books of conference proceedings. We searched the reference lists of each trial for additional publications possibly containing other trials.Most recent search: 22 February 2013. Randomised controlled trials comparing a form of pressure preset or volume preset non-invasive ventilation to no non-invasive ventilation in people with acute or chronic respiratory failure in cystic fibrosis. Three reviewers independently assessed trials for inclusion criteria and methodological quality, and extracted data. Fifteen trials were identified; seven trials met the inclusion criteria with a total of 106 participants. Six trials evaluated single treatment sessions and one evaluated a six-week intervention.Four trials (79 participants) evaluated non-invasive ventilation for airway clearance compared with an alternative chest physiotherapy method and showed that airway clearance may be easier with non-invasive ventilation and people with cystic fibrosis may prefer it. We were unable to find any evidence that NIV increases sputum expectoration, but it did improve some lung function parameters.Three trials (27 participants) evaluated non-invasive ventilation for overnight ventilatory support, measuring lung function, validated quality of life scores and nocturnal transcutaneous carbon dioxide. Due to the small numbers of participants and statistical issues, there were discrepancies in the results between the RevMan and the original trial analyses. No clear differences were found between non-invasive ventilation compared with oxygen or room air except for exercise performance, which significantly improved with non-invasive ventilation compared to room air over six weeks. Non-invasive ventilation may be a useful adjunct to other airway clearance techniques, particularly in people with cystic fibrosis who have difficulty expectorating sputum. Non-invasive ventilation, used in addition to oxygen, may improve gas exchange during sleep to a greater extent than oxygen therapy alone in moderate to severe disease. These benefits of non-invasive ventilation have largely been demonstrated in single treatment sessions with small numbers of participants. The impact of this therapy on pulmonary exacerbations and disease progression remain unclear. There is a need for long-term randomised controlled trials which are adequately powered to determine the clinical effects of non-invasive ventilation in cystic fibrosis airway clearance and exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The real utilisation scenario of non-invasive ventilation (NIV) in Swiss ICUs has never been reported. Using a survey methodology, we developed a questionnaire sent to the directors of the 79 adult ICUs to identify the perceived pattern of NIV utilisation. We obtained a response rate of 62%. The overall utilisation rate for NIV was 26% of all mechanical ventilations, but we found significant differences in the utilisation rates among different linguistic areas, ranging from 20% in the German part to 48% in the French part (p <0.01). NIV was mainly indicated for the acute exacerbations of COPD (AeCOPD), acute cardiogenic pulmonary edema (ACPE) and acute respiratory failure (ARF) in selected do-not-intubate patients. In ACPE, CPAP was much less used than bi-level ventilation and was still applied in AeCOPD. The first line interface was a facial mask (81%) and the preferred type of ventilator was an ICU machine with an NIV module (69%). The perceived use of NIV is generally high in Switzerland, but regional variations are remarkable. The indications of NIV use are in accordance with international guidelines. A high percentage of units consider selected do-not-intubate conditions as an important additional indication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS This study's objective is to assess the safety of non-therapeutic atomoxetine exposures reported to the US National Poison Database System (NPDS). METHODS This is a retrospective database study of non-therapeutic single agent ingestions of atomoxetine in children and adults reported to the NPDS between 2002 and 2010. RESULTS A total of 20 032 atomoxetine exposures were reported during the study period, and 12 370 of these were single agent exposures. The median age was 9 years (interquartile range 3, 14), and 7380 were male (59.7%). Of the single agent exposures, 8813 (71.2%) were acute exposures, 3315 (26.8%) were acute-on-chronic, and 166 (1.3%) were chronic. In 10 608 (85.8%) cases, exposure was unintentional, in 1079 (8.7%) suicide attempts, and in 629 (5.1%) cases abuse. Of these cases, 3633 (29.4 %) were managed at health-care facilities. Acute-on-chronic exposure was associated with an increased risk of a suicidal reason for exposure compared with acute ingestions (odds ratio 1.44, 95% confidence interval 1.26-1.65). Most common clinical effects were drowsiness or lethargy (709 cases; 5.7%), tachycardia (555; 4.5%), and nausea (388; 3.1%). Major toxicity was observed in 21 cases (seizures in nine (42.9%), tachycardia in eight (38.1%), coma in six (28.6%), and ventricular dysrhythmia in one case (4.8%)). CONCLUSIONS Non-therapeutic atomoxetine exposures were largely safe, but seizures were rarely observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Non-invasive ventilation (NIV) is increasingly used in patients with Acute Respiratory Distress Syndrome (ARDS). Whether, during NIV, the categorization of ARDS severity based on the PaO2/FiO2 Berlin criteria is useful is unknown. The evidence supporting NIV use in patients with ARDS remains relatively sparse.

Methods: The Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study described the management of patients with ARDS. This sub-study examines the current practice of NIV use in ARDS, the utility of the PaO2/FiO2 ratio in classifying patients receiving NIV and the impact of NIV on outcome.

Results: Of 2,813 patients with ARDS, 436 (15.5%) were managed with NIV on days 1 and 2 following fulfillment of diagnostic criteria. Classification of ARDS severity based on PaO2/FiO2 ratio was associated with an increase in intensity of ventilatory support, NIV failure, and Intensive Care Unit (ICU) mortality. NIV failure occurred in 22.2% of mild, 42.3% of moderate and 47.1% of patients with severe ARDS. Hospital mortality in patients with NIV success and failure was 16.1 % and 45.4%, respectively. NIV use was independently associated with increased ICU (HR 1.446; [1.159-1.805]), but not hospital mortality. In a propensity matched analysis, ICU mortality was higher in NIV than invasively ventilated patients with a PaO2/FiO2 lower than 150 mmHg.

Conclusions: NIV was used in 15% of patients with ARDS, irrespective of severity category. NIV appears to be associated with higher ICU mortality in patients with a PaO2/FiO2 lower than 150 mmHg.

Trial Registration: ClinicalTrials.gov NCT02010073

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive ventilation performed through an oronasal mask is a standard in clinical and homecare mechanical ventilation. Besides all its advantages, inevitable leaks through the mask cause errors in the feedback information provided by the airflow sensor and, hence, patient-ventilator asynchrony with multiple negative consequences. Here we investigate a new way to provide a trigger to the ventilator. The method is based on the measurement of rib cage movement at the onset of inspiration and during breathing by fibre-optic sensors. In a series of simultaneous measurements by a long-period fibre grating sensor and pneumotachograph we provide the statistical evidence of the 200 ms lag of the pneumo with respect the fibre-optic signal. The lag is registered consistently across three independent delay metrics. Further, we discuss exceptions from this trend and identify the needed improvements to the proposed fibre-sensing scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive ventilation (NIV) is the application of a ventilatory support without resorting to invasive methods. Today it’s considered a credible therapeutic option, with enough scientiic evidence to support its application in various situations and clinical settings related to the treatment of acute respiratory disease, as well as chronic respiratory disease. Objectives: Characterize patients undergoing NIV admitted in Unit Intermediate Care (ICU) in the period from October 1st 2015 to June 30th 2016. Methods: Prospective study conducted in ICU between October 2015 and June 2016. In this study were included all patients hospitalized in this unit (ICU) and in that time period a sample of 57 participants was obtained. As data collection instruments we used a questionnaire for sociodemographic and clinical data and the Braden scale. Results: Participants were mostly male 38 (66.7%), the average age 69.5 ± 11.3 years, ranging between 43 and 92 years. They weighed on average 76.6 kg (52 and 150), with an average body mass index of 28.5 kg/m2 (20 to 58.5). With skin intact 28 (49.1%) with abnormal perfusion 12 (21.1%), with altered sensitivity 11 (19.3%) and a high risk of ulcer on the scale of Braden 37 (65%). The admission diagnosis was respiratory failure 33 (57.3%) and had different backgrounds. We used reused mask 53 (93.0%), the average time of NIV was 7.1 days (1-28), 4.8 days of hospitalization (1-18) and an average of 7.8 IPAP pressure. 11 (19.3%) of the participants developed face ulcer pressure.Conclusions: The NIV is used in patients with advanced age, obesity, respiratory failure and high risk of face ulcer development.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective
Preliminary assessment of an automated weaning system (SmartCare™/PS) compared to usual management of weaning from mechanical ventilation performed in the absence of formal protocols.


Design and setting
A randomised, controlled pilot study in one Australian intensive care unit.


Patients
A total of 102 patients were equally divided between SmartCare/PS and Control.

Interventions
The automated system titrated pressure support, conducted a spontaneous breathing trial and provided notification of success (“separation potential”).

Measurements and results
The median time from the first identified point of suitability for weaning commencement to the state of “separation potential” using SmartCare/PS was 20 h (interquartile range, IQR, 2–40) compared to 8 h (IQR 2–43) with Control (log-rank P = 0.3). The median time to successful extubation was 43 h (IQR 6–169) using SmartCare/PS and 40 (14–87) with Control (log-rank P = 0.6). Unadjusted, the estimated probability of reaching “separation potential” was 21% lower (95% CI, 48% lower to 20% greater) with SmartCare/PS compared to Control. Adjusted for other covariates (age, gender, APACHE II, SOFAmax, neuromuscular blockade, corticosteroids, coma and elevated blood glucose), these estimates were 31% lower (95% CI, 56% lower to 9% greater) with SmartCare/PS. The study groups showed comparable rates of reintubation, non-invasive ventilation post-extubation, tracheostomy, sedation, neuromuscular blockade and use of corticosteroids.

Conclusions
Substantial reductions in weaning duration previously demonstrated were not confirmed when the SmartCare/PS system was compared to weaning managed by experienced critical care specialty nurses, using a 1:1 nurse-to-patient ratio. The effect of SmartCare/PS may be influenced by the local clinical organisational context.