894 resultados para Negative refraction
Resumo:
We examined the optical properties of nanolayered metal-dielectric lattices. At subwavelength regimes, the periodic array of metallic nanofilms demonstrates nonlocality-induced double refraction, conventional positive and as well as negative. In particular, we report on energy-flow considerations concerning both refractive behaviors concurrently. Numerical simulations provide transmittance of individual beams in Ag-TiO2 metamaterials under different configurations. In regimes of the effective-medium theory predicting elliptic dispersion, negative refraction may be stronger than the expected positive refraction.
Resumo:
RESUMO: Na parte inicial incluem-se algumas notas sucintas com base no panorama científico,histórico e cultural da visão considerada segundo três abordagens - o olho (o olho humano na especificidade da sua posição filogenética, elemento anátomo-funcional básico do sistema visual ao qual o cérebro pertence), os olhos (unidades gémeas essenciais do rosto na sua actividade consensual e conjugada da binocularidade), o olhar (carregado de expressão psicológica e o seu efeito sobre o observador, sinal para o comportamento e criador de sentimentos, sedimentado em obras de arte e em formas de superstição dos povos). Segue-se a apresentação de um estudo descritivo transversal, como contribuição para o conhecimento do estado de saúde visual da população infantil da região de Lisboa e determinar factores que o influenciam. Entre Outubro de 2005 e Agosto de 2006 examinaram-se 649 crianças com idade inferior a 10 anos da Consulta de Oftalmologia Pediátrica dos Serviços de Assistência Médico-Social do Sindicato dos Bancários do Sul e Ilhas (SAMS). Colheram-se dados respeitantes a mais de 250 variáveis primárias que cobriram a maior parte dos itens do exame oftalmológico habitual. Na análise dos dados teve-se especialmente em conta a idade, com um papel decisivo nas principais fases de desenvolvimento do sistema visual. No caso das crianças de 6 a 7 anos de idade põem-se lado a lado resultados dos SAMS e das Escolas. A profusão de dados numéricos ditou a necessidade da determinação frequente da significância estatística dos resultados de subgrupos. Alguns resultados do estudo, na sua maioria do grupo SAMS: Crianças de 6-7 anos, 71,1% (SAMS) e 91,5% (Escolas) não tinham sido examinadas com menos de 4 anos. Frequência global de alterações miópicas 9,4%, de alterações hipermetrópicas 25,3%, umas e outras com variações acentuadas com a idade. Estrabismo convergente 3,9%. Ambliopia 2,6% (13/491 crianças >=4 anos de idade), mais frequente no sexo feminino, naquelas que tiveram a sua 1ª observação depois dos 4 anos e em que os pais não aderiam à terapêutica prescrita. Objectivos específicos ocuparam-se da acuidade visual e da refracção ocular. O estudo comparativo da refractometria automática sem e com cicloplegia permitiu evidenciar que o teste da acuidade visual é insuficiente, por si só, para fazer o diagnóstico correcto. A análise dos antecedentes familiares oftalmológicos demonstrou a importância do seu conhecimento e pôs em evidência, entre outras, as seguintes relações: 10 pag1.qxp 27-11-2001 18:28 Page 10 Índice Geral 11 Crianças com antecedentes de alterações miópicas têm maior frequência de diagnóstico de alterações miópicas e de refracção negativa, uma taxa mais elevada de correspondência quantitativa diagnóstico/refracção nas alterações miópicas. Estas crianças também têm, em geral, características inversas no que diz respeito a alterações hipermetrópicas. Crianças com antecedentes de alterações hipermetrópicas têm maior frequência de diagnóstico de alterações hipermetrópicas. Crianças com antecedentes de estrabismo têm maior frequência de diagnóstico de estrabismo convergente manifesto e de esodesvios no seu todo. Crianças com antecedentes familiares de astigmatismo têm maior frequência de diagnóstico de astigmatismo. Traçam-se alguns perfis oftalmológicos infantis que permitem apreciar de forma sinóptica um conjunto de parâmetros da saúde da visão. Os dados colhidos sobre a aderência dos pais à terapêutica prescrita e sobre a atitude em relação ao uso de óculos assim como os dados sobre o comportamento da criança na sala de aula e dificuldades de aprendizagem foram em geral escassos para permitirem tirar conclusões, embora mostrem indícios a investigar futuramente. Paralelamente ortoptistas e enfermeiras efectuaram um rastreio escolar da acuidade visual <0,8 e de alterações da motilidade ocular extrínseca que abrangeu 520 alunos do 1º ano do 1º ciclo do ensino básico (2005/2006) das escolas públicas da cidade de Lisboa. 101 destas crianças foram observadas no consultório da autora, umas referidas a partir do rastreio, outras como controlo deste. Quanto à acuidade visual o valor preditivo do teste negativo foi de 91% mas o do teste positivo de apenas 67% (33% de falsos positivos, consequentemente uma alta taxa de sobrerreferenciação). A qualidade do rastreio efectuado por ortoptistas foi inferior à do efectuado por enfermeiras. O rastreio não teve qualidade aceitável. Foi feito um inquérito a médicos e enfermeiros de centros de saúde sobre conhecimentos, atitudes e práticas em relação com os cuidados de oftalmologia pediátrica. Discutem-se os resultados, tiram-se conclusões e fazem-se recomendações susceptíveis de contribuir para uma melhor saúde visual das crianças. ABSTRACT: Firstly some brief remarks are made based on the scientific, historical and cultural panorama of the human vision with regard to three approaches: the eye (the human eye in its specific filogenetic place, fundamental anatomofunctional element of the visual system in interaction with the brain), the eyes (essential twin units of the face with their consensual and conjugated binocular activity), the gaze (psychologicaly overloaded, a means to express oneself and to influence the observer, a guide to other persons' behaviour, consolidated in works of art and in people's traditional superstitious believes and ways of thinking). A report is made on a cross-sectional descriptive study whose goal is to contribute to the knowledge of the level of visual health of children in the Lisbon Region and to identify factors which determine it. Between October 2005 and August 2006 649 children under 10 years were observed at the pediatric ophthalmologic consultation in the SAMS (Serviços de Assistência Médico-Social do Sindicato dos Bancários do Sul e Ilhas). Data were collected concerning more than 250 primary variables covering most itens of the usual ophthalmological examination. Special attention was paid to children's age since it plays a crucial role in main stages of visual system development. In the case of children age 6 to 7 SAMS and school results are often put side by side. On account of the great number of numerical data it was often necessary to look at the degree of statistical significancy of differencies between subgroups. Some of the study's results (mostly SAMS): Children age 6 to 7 - 71,1% (SAMS) and 91,5% (Schools) had not an ophthalmologic examination before 4 years old. Total frequency of myopic disorders 9,4%, of hypermetropic disorders 25,3%, both showing great differences between age groups; convergent strabismus 3,9%; amblyopia 2,6% (13/491 children over 3 years old), more frequent among little girls, in those with 1st examination after 4 years old and in those whose parents didn´t complied to the therapy ordered for the child. Specific objectives dealt with visual acuity and ocular refraction. The comparison of automatic refractometry without and with cycloplegy showed that visual acuity testing is often not enough for a correct diagnosis. Eye disorders in the family history proved to be a very important information. Analysis of corresponding data disclosed a lot of relationships among others: 12 pag1.qxp 27-11-2001 18:28 Page 12 Índice Geral 13 Children with a family history of myopic disorders have more frequently a diagnosis of myopic disorders and a negative refraction, a higher rate of quantitative diagnosis/refraction matching concerning myopic disorders. Those children have in general inverse characteristics regarding hypermetropic disorders. Children with a family history of hypermetropic disorders have more frequently a diagnosis of hypermetropic disorders. Children with a family history of strabismus have more frequently a diagnosis of manifest convergent strabismus and all forms of esodeviations. Children with a family history of astigmatism have more frequently a diagnosis of astigmatism. Ophthalmologic profiles are drawn allowing to take into account in a synoptic way a set of visual health parameters. Data on parents' compliance with therapy ordered for the child, and attitudes regarding child's glass wearing, as well as data on child's behaviour in the classroom and learning difficulties were as a rule too few to allow conclusions but still need more studies in the future. Orthoptists and nurses performed in the same study period a screening of visual acuity <0,8 and of ocular motility disorders addressed to children of 1srt degree of public schools (term 2005/2006) in the town of Lisbon. 520 of such children were screened. 101 of them were examined by the author in her medical office; some were refered, the others taken as a control. Regarding visual acuity the predictive value of a negative test was 91% but the predictive value of a positive test was only 67% (33% of false positive results, consequently a too high rate of overreferal). Performed by orthoptists screening quality was inferior in comparison with screening done by nurses. On the whole this screening had not the required quality. A survey on physicians' and nurses' knowledge, attitudes and practices related to pediatric ophthalmologic care was carried out in health centers. Results are discussed, conclusions drawn. Some suggestions are made aiming at a better children's visual health.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
An exact expression is derived for the time-averaged electromagnetic energy within a magneto-dielectric coated sphere, which is irradiated by a plane and time-harmonic electromagnetic wave. Both the spherical shell and core are considered to be dispersive and lossy, with a realistic dispersion relation of an isotropic split-ring resonator metamaterial. We obtain analytical expressions for the stored electromagnetic energies inside the core and the shell separately and calculate their contributions to the total average energy density. The stored electromagnetic energy is calculated for two situations involving a metamaterial coated sphere: a dielectric shell and dispersive metamaterial core, and vice versa. An explicit relation between the stored energy and the optical absorption efficiency is also obtained. We show that the stored electromagnetic energy is an observable sensitive to field interferences responsible for the Fano effect. This result, together with the fact that the Fano effect is more likely to occur in metamaterials with negative refraction, suggest that our findings may be explored in applications.
Resumo:
We report on a procedure to improve the resolution of far-field imaging by using a neighboring high-index medium that is coated with a left-handed metamaterial. The resulting plot can also exhibit an enhanced transmission by considering proper conditions to retract backscattering. Based on negative refraction, geometrical aberrations are considered in detail since they may cause a great impact in this sort of diffraction-unlimited imaging by reducing its resolution power. We employ a standard aberration analysis to refine the asymmetric configuration of metamaterial superlenses. We demonstrate that low-order centrosymmetric aberrations can be fully corrected for a given object plane. For subwavelength-resolution imaging, however, high-order aberrations become of relevance, which may be balanced with defocus. Not only the point spread function but also numerical simulations based on the finite-element method support our theoretical analysis, and subwavelength resolution is verified in the image plane.
Resumo:
We show that subwavelength diffracted wave fields may be managed inside multilayered plasmonic devices to achieve ultra-resolving lensing. For that purpose we first transform both homogeneous waves and a broad band of evanescent waves into propagating Bloch modes by means of a metal/dielectric (MD) superlattice. Beam spreading is subsequently compensated by means of negative refraction in a plasmon-induced anisotropic effective-medium that is cemented behind. A precise design of the superlens doublet may lead to nearly aberration-free images with subwavelength resolution in spite of using optical paths longer than a wavelength.
Resumo:
Metamaterials are artificial materials that exhibit properties, such as negative index of refraction, that are not possible through natural materials. Due to many potential applications of negative index metamaterials, significant progress in the field has been observed in the last decade. However, achieving negative index at visible frequencies is a challenging task. Generally, fishnet metamaterials are considered as a possible route to achieve negative index in the visible spectrum. However, so far no metamaterial has been demonstrated to exhibit simultaneously negative permittivity and permeability (double-negative) beyond the red region of the visible spectrum. This study is mainly focused on achieving higher operating frequency for low-loss, double-negative metamaterials. Two double-negative metamaterials have been proposed to operate at highest reported frequencies. The first proposed metamaterial is based on the interaction of surface plasmon polaritons of a thin metal film with localized surface plasmons of a metallic array placed close to the thin film. It is demonstrated that the metamaterial can easily be scaled to operate at any frequency in the visible spectrum as well as possibly to the ultraviolet spectrum. Furthermore, the underlying physical phenomena and possible future extensions of the metamaterial are also investigated. The second proposed metamaterial is a modification to the so-called fishnet metamaterial. It has been demonstrated that this ‘modified fishnet’ exhibits two double-negative bands in the visible spectrum with highest operating frequency in the green region with considerably high figure of merit. In contrast to most of the fishnet metamaterials proposed in the past, behavior of this modified fishnet is independent of polarization of the incident field. In addition to the two negative index metamaterials proposed in this study, the use of metamaterial as a spacer, named as metaspacer, is also investigated. In contrast to naturally available dielectric spacers used in microfabrication, metaspacers can be realized with any (positive or negative) permittivity and permeability. As an example, the use of a negative index metaspacer in place of the dielectric layer in a fishnet metamaterial is investigated. It is shown that fishnet based on negative index metaspacer gives many improved optical properties over the conventional fishnet such as wider negative index band, higher figure of merit, higher optical transmission and stronger magnetic response. In addition to the improved properties, following interesting features were observed in the metaspacer based fishnet metamaterial. At the resonance frequency, the shape of the permeability curve was ‘inverted’ as compared to that for conventional fishnet metamaterial. Furthermore, dependence of the resonance frequency on the fishnet geometry was also reversed. Moreover, simultaneously negative group and phase velocities were observed in the low-loss region of the metaspacer based fishnet metamaterial. Due to interesting features observed using metaspacer, this study will open a new horizon for the metamaterial research.
Resumo:
Super-resolution (SR) systems surpassing the Abbe diffraction limit have been theoretically and experimentally demonstrated using a number of different approaches and technologies: using materials with a negative refractive index, utilizing optical super-oscillation, using a resonant metalens, etc. However, recently it has been proved theoretically that in the Maxwell fish-eye lens (MFE), a device made of positive refractive index materials, the same phenomenon takes place. Moreover, using a simpler device equivalent to the MFE called the spherical geodesic waveguide (SGW), an SR of up to λ/3000 was simulated in COMSOL. Until now, only one piece of experimental evidence of SR with positive refraction has been reported (up to λ/5) for an MFE prototype working at microwave frequencies. Here, experimental results are presented for an SGW prototype showing an SR of up to λ/105. The SGW prototype consists of two concentric metallic spheres with an air space in between and two coaxial ports acting as an emitter and a receiver. The prototype has been analyzed in the range 1 GHz to 1.3 GHz.
Resumo:
Background: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). Methods: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later. Results: The autorefractor prescription was similar (average difference: 0.09±0.53 D; p=0.19) to that found by subjective refraction, with ~71% within ±0.50 D. The horizontal cylindrical components were similar (difference: 0.00±0.39 D; p=0.96), although the oblique (J45) autorefractor cylindrical vector was slightly more negative (by -0.06±0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was
Resumo:
Background: The aim was to evaluate the validity and repeatability of the auto-refraction function of the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) compared with non-cycloplegic subjective refraction. The Nidek OPD-Scan III is a new aberrometer/corneal topographer workstation based on the skiascopy principle. It combines a wavefront aberrometer, topographer, autorefractor, auto keratometer and pupillometer/pupillographer. Methods: Objective refraction results obtained using the Nidek OPD-Scan III were compared with non-cycloplegic subjective refraction for 108 eyes of 54 participants (29 female) with a mean age of 23.7±9.5 years. Intra-session and inter-session variability were assessed on 14 subjects (28 eyes). Results: The Nidek OPD-Scan III gave slightly more negative readings than results obtained by subjective refraction (Nidek mean difference -0.19±0.36 DS, p<0.01 for sphere; -0.19±0.35 DS, p<0.01 for mean spherical equivalent; -0.002±0.23 DC, p=0.91 for cylinder; -0.06±0.38 DC, p=0.30 for J0 and -0.36±0.31 DC for J45, p=0.29). Auto-refractor results for 74 per cent of spherical readings and 60 per cent of cylindrical powers were within±0.25 of subjective refraction. There was high intra-session and inter-session repeatability for all parameters; 90 per cent of inter-session repeatability results were within 0.25 D. Conclusion: The Nidek OPD-Scan III gives valid and repeatable measures of objective refraction when compared with non-cycloplegic subjective refraction. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Resumo:
Despite the remarkable improvements in breast cancer (BC) characterization, accurate prediction of BC clinical behavior is often still difficult to achieve. Some studies have investigated the association between the molecular subtype, namely the basal-like BC and the pattern of relapse, however only few investigated the association between relapse pattern and immunohistochemical defined triple-negative breast cancers (TNBCs). The aim of this study was to evaluate the pattern of relapse in patients with TNBC, namely the primary distant relapse site. One-hundred twenty nine (129) invasive breast carcinomas with follow-up information were classified according to the molecular subtype using immunohistochemistry for ER, PgR and Her2. The association between TNBC and distant relapse primary site was analyzed by logistic regression. Using multivariate logistic regression analysis patients with TNBC displayed only 0.09 (95% CI: 0.00-0.74; p=0.02) the odds of the non-TNBC patients of developing bone primary relapse. Regarding visceral and lymph-node relapse, no differences between in this cohort were found. Though classically regarded as aggressive tumors, TNBCs rarely development primary relapse in bone when compared to non-TNBC, a clinical relevant fact when investigating a metastasis of an occult or non-sampled primary BC.
Resumo:
We assessed associations between steroid receptors including: estrogen-alpha, estrogen-beta, androgen receptor, progesterone receptor, the HER2 status and triple-negative epithelial ovarian cancer (ERα-/PR-/HER2-; TNEOC) status and survival in women with epithelial ovarian cancer. The study included 152 women with primary epithelial ovarian cancer. The status of steroid receptor and HER2 was determined by immunohistochemistry. Disease-free and overall survival were calculated and compared with steroid receptor and HER2 status as well as clinicopathological features using the Cox Proportional Hazards model. A mean follow-up period of 43.6 months (interquartile range=41.4 months) was achieved where 44% of patients had serous tumor, followed by mucinous (23%), endometrioid (9%), mixed (9%), undifferentiated (8.5%) and clear cell tumors (5.3%). ER-alpha staining was associated with grade II-III tumors. Progesterone receptor staining was positively associated with a Body Mass Index≥25. Androgen receptor positivity was higher in serous tumors. In stand-alone analysis of receptor contribution to survival, estrogen-alpha positivity was associated with greater disease-free survival. However, there was no significant association between steroid receptor expression, HER2 status, or TNEOC status, and overall survival. Although estrogen-alpha, androgen receptor, progesterone receptor and the HER2 status were associated with key clinical features of the women and pathological characteristics of the tumors, these associations were not implicated in survival. Interestingly, women with TNEOC seem to fare the same way as their counterparts with non-TNEOC.
Resumo:
To evaluate whether dyspareunia is associated with HIV status in menopausal women and also to assess which factors are associated with dyspareunia in a group of HIV-positive menopausal women. A cross-sectional study was conducted with 178 HIV-negative and 128 HIV-positive women aged 40-60 years. The Short Personal Experiences Questionnaire (SPEQ) was used to collect data. Sociodemographic, clinical, behavioural and reproductive factors were evaluated, as well as factors related to the HIV infection. Dyspareunia was defined as pain during intercourse. A bivariate analysis and Poisson multiple regression analysis were performed. Overall, 41.4% of the HIV-positive women reported dyspareunia compared with 34.8% of the HIV-negative women (p=0.242). In the HIV-positive women, bivariate analysis revealed an association between dyspareunia and having a steady partner (p=0.047); the woman's partner having undergone HIV testing (p=0.020); vaginal dryness (p<0.001); muscle/joint pain (p=0.021); physical/emotional violence (p=0.049); urinary incontinence (p=0.004); and the use of lamivudine/zidovudine (p=0.048). The Poisson multiple regression analysis found an association between dyspareunia and vaginal dryness (prevalence ratio (PR)=1.96, 95% CI 1.10 to 3.50, p=0.023) and urinary incontinence (PR=1.86, 95% CI 1.06 to 3.27, p=0.031). Dyspareunia was common in this group of HIV-positive women and was associated principally with vaginal dryness and urinary incontinence. The importance of treating dyspareunia within the context of sexual health in this group of women should be emphasised and appropriate management of this issue may reduce the likelihood of lesions on the vaginal wall, which may act as a portal of entry for other infections.
Resumo:
Um total de 109 cepas de Staphylococci coagulase-negativa foi isolado de leite de vacas com mastite clínica e subclínica, em 35 fazendas, situadas em nove estados brasileiros, no período de fevereiro a maio de 2005. Os isolados foram investigados em relação a susceptibilidade in vitro a diversos agentes antimicrobianos. A resistência à penicilina foi a observação mais freqüente (93,5%), seguida por sulfonamida (88,9%), novobiocina (88,6%) e ampicilina (85,3%). Todas as cepas examinadas mostraram resistência a pelo menos uma das drogas antimicrobianas testadas. Cepas apresentando resistência múltipla foram extremamente comuns, com 10,0% dos microrganismos isolados apresentando resistência a todas as drogas antimicrobianas. Os resultados obtidos indicaram que as cepas de Staphylococci coagulase-negativas, isoladas no Brasil, apresentaram um alto grau de resistência a antimicrobianos. Estes resultados são, provavelmente, uma conseqüência da pressão devida ao uso intensivo de drogas antimicrobianas.
Resumo:
Avaliou-se a sensibilidade antimicrobiana in vitro de 121 cepas de estafilococos coagulase-negativa isolada de leite de ovelhas Santa Inês, aos fármacos: penicilina, amoxicilina, ampicilina, estreptomicina, oxaciclina, neomicina, cefalotina, gentamicina e sulfonamida. A resistência à sulfonamida foi a mais frequente (27,3%), seguida pela estreptomicina (14,0%) e pela oxaciclina (14,0%), enquanto da gentamicina (1,6%) foi a menos frequente. Todas as cepas foram sensíveis a pelo menos um antimicrobiano, e 20,3% das cepas apresentaram resistência múltipla. Os resultados mostram a importância de Staphylococci coagulase-negativas como agentes causadores de mastite em ovinos, e o perfil de resistência múltipla indica a importância da determinação da resistência à oxaciclina como indicador da presença de ilhas de patogenicidade que contêm fatores de virulência e resistência a outros antimicrobianos que contribuem para a sobrevivência da bactéria ao tratamento.