991 resultados para Negative Poisson ratio
Resumo:
Tese de Doutoramento Engenharia Têxtil
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Auxetic materials (or metamaterials) are those with a negative Poisson ratio (NPR) and display the unexpected property of lateral expansion when stretched, as well as an equal and opposing densification when compressed. Such geometries are being progressively employed in the development of novel products, especially in the fields of intelligent expandable actuators, shape morphing structures and minimally invasive implantable devices. Although several auxetic and potentially auxetic geometries have been summarized in previous reviews and research, precise information regarding relevant properties for design tasks is not always provided. In this study we present a comparative study of two-dimensional and three-dimensional auxetic geometries carried out by means of computer-aided design and engineering tools (from now on CAD–CAE). The first part of the study is focused on the development of a CAD library of auxetics. Once the library is developed we simulate the behavior of the different auxetic geometries and elaborate a systematic comparison, considering relevant properties of these geometries, such as Poisson ratio(s), maximum volume or area reductions attainable and equivalent Young's modulus, hoping it may provide useful information for future designs of devices based on these interesting structures.
Resumo:
The computational design of a composite where the properties of its constituents change gradually within a unit cell can be successfully achieved by means of a material design method that combines topology optimization with homogenization. This is an iterative numerical method, which leads to changes in the composite material unit cell until desired properties (or performance) are obtained. Such method has been applied to several types of materials in the last few years. In this work, the objective is to extend the material design method to obtain functionally graded material architectures, i.e. materials that are graded at the local level (e.g. microstructural level). Consistent with this goal, a continuum distribution of the design variable inside the finite element domain is considered to represent a fully continuous material variation during the design process. Thus the topology optimization naturally leads to a smoothly graded material system. To illustrate the theoretical and numerical approaches, numerical examples are provided. The homogenization method is verified by considering one-dimensional material gradation profiles for which analytical solutions for the effective elastic properties are available. The verification of the homogenization method is extended to two dimensions considering a trigonometric material gradation, and a material variation with discontinuous derivatives. These are also used as benchmark examples to verify the optimization method for functionally graded material cell design. Finally the influence of material gradation on extreme materials is investigated, which includes materials with near-zero shear modulus, and materials with negative Poisson`s ratio.
Resumo:
Tese de Doutoramento em Engenharia Têxtil
Resumo:
Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (∞), NLR (0.017), and Ef (99%).
Resumo:
Since they present a negative Poisson's radio, auxetic materials are different from conventional ones. These materials present an unusual behaviour: when stretched (elongated in the longitudinal direction), their cross-section is increased. There are two different ways to obtain auxetic materials: through polymers or through structures. It is possible to affirm that those obtained through fibrous structures are very recent and that few authors have been dedicated to their study. The main objective of this work is to study the effect of the negative Poisson
Resumo:
Auxetic materials are a class of materials behaves unusual way compared to regular materials i.e. possess negative Poisson’s ratio. This paper reports, the development of auxetic structures based on re-entrant hexagon design from braided composite materials and testing of the mechanical properties (tensile property, auxetic property and work of rupture). The structure developed from glass and basalt braided composite rods and properties were compared between them. Later, the basic re-entrant hexagon design was modified with vertical straight rods to improve their mechanical behavior and their auxetic property was studied. Auxetic behavior of these structures was studied in a tensile testing machine taking video during testing by Digital camera, later the video converted into images to measure the strain values using simple software, ImageJ. Along with experimental work, analytical model was used to calculate the Poisson’s ratio of basic structure and results were compared
Resumo:
The spontaneous breathing trial (SBT)-relying on objective criteria assessed by the clinician-is the major diagnostic tool to determine if patients can be successfully extubated. However, little is known regarding the patient's subjective perception of autonomous breathing. We performed a prospective observational study in 211 mechanically ventilated adult patients successfully completing a SBT. Patients were randomly assigned to be interviewed during this trial regarding their prediction of extubation success. We compared post-extubation outcomes in three patient groups: patients confident (confidents; n = 115) or not (non-confidents; n = 38) of their extubation success and patients not subjected to interview (control group; n = 58). Extubation success was more frequent in confidents than in non-confidents (90 vs. 45%; p < 0.001/positive likelihood ratio = 2.00) or in the control group (90 vs. 78%; p = 0.04). On the contrary, extubation failure was more common in non-confidents than in confidents (55 vs. 10%; p < 0.001/negative likelihood ratio = 0.19). Logistic regression analysis showed that extubation success was associated with patient's prediction [OR (95% CI): 9.2 (3.74-22.42) for confidents vs.non-confidents] as well as to age [0.72 (0.66-0.78) for age 75 vs. 65 and 1.31 (1.28-1.51) for age 55 vs. 65]. Our data suggest that at the end of a sustained SBT, extubation success might be correlated to the patients' subjective perception of autonomous breathing. The results of this study should be confirmed by a large multicenter trial.
Resumo:
We validated the polymerase chain reaction (PCR) with a composite reference standard in 61 patients clinically suspected of having mucosal leishmaniasis, 36 of which were cases and 25 were non-cases according to this reference standard. Patient classification and test application were carried out independently by two blind observers. One pair of primers was used to amplify a fragment of 120 bp in the conserved region of kDNA and another pair was used to amplify the internal transcript spacers (ITS) rDNA. PCR showed 68.6% (95% CI 59.2-72.6) sensitivity and 92% (95% CI 78.9-97.7) specificity; positive likelihood ratio: 8.6 (95% CI 2.8-31.3) and negative likelihood ratio: 0.3 (95% CI 0.3-0.5), when kDNA molecular target was amplified. The test performed better on sensitivity using this target compared to the ITS rDNA molecular target which showed 40% (95% CI 31.5-42.3) sensitivity and 96% (95% CI 84.1-99.3) specificity; positive likelihood ratio: 10 (95% CI 2.0-58.8) and negative likelihood ratio: 0.6 (95% CI 0.6-0.8). The inter-observer agreement was excellent for both tests. Based upon results obtained and due to low performance of conventional methods for diagnosing mucosal leishmaniasis, we consider PCR with kDNA as molecular target is a useful diagnostic test and the ITS rDNA molecular target is useful when the aim is to identify species.
Resumo:
RATIONALE AND OBJECTIVES: To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATERIALS: A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. RESULTS: Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.
Resumo:
PURPOSE: The aim of this study was to conduct a systematic review and perform a meta-analysis on the diagnostic performances of (18)F-fluorodeoxyglucose positron emission tomography (FDG PET) for giant cell arteritis (GCA), with or without polymyalgia rheumatica (PMR). METHODS: MEDLINE, Embase and the Cochrane Library were searched for articles in English that evaluated FDG PET in GCA or PMR. All complete studies were reviewed and qualitatively analysed. Studies that fulfilled the three following criteria were included in a meta-analysis: (1) FDG PET used as a diagnostic tool for GCA and PMR; (2) American College of Rheumatology and Healey criteria used as the reference standard for the diagnosis of GCA and PMR, respectively; and (3) the use of a control group. RESULTS: We found 14 complete articles. A smooth linear or long segmental pattern of FDG uptake in the aorta and its main branches seems to be a characteristic pattern of GCA. Vessel uptake that was superior to liver uptake was considered an efficient marker for vasculitis. The meta-analysis of six selected studies (101 vasculitis and 182 controls) provided the following results: sensitivity 0.80 [95% confidence interval (CI) 0.63-0.91], specificity 0.89 (95% CI 0.78-0.94), positive predictive value 0.85 (95% CI 0.62-0.95), negative predictive value 0.88 (95% CI 0.72-0.95), positive likelihood ratio 6.73 (95% CI 3.55-12.77), negative likelihood ratio 0.25 (95% CI 0.13-0.46) and accuracy 0.84 (95% CI 0.76-0.90). CONCLUSION: We found overall valuable diagnostic performances for FDG PET against reference criteria. Standardized FDG uptake criteria are needed to optimize these diagnostic performances.
Resumo:
BACKGROUND: Our objective was to evaluate procalcitonin (PCT) and C-reactive protein (CRP) as predictors of a pneumococcal etiology in community-acquired pneumonia (CAP) in hospitalized children. METHODS: Children requiring hospitalization for CAP were prospectively enrolled. The following indices were determined: antibodies against pneumococcal surface proteins (anti-PLY, pneumococcal histidine triad D, pneumococcal histidine triad E, LytB and pneumococcal choline-binding protein A), viral serology, nasopharyngeal cultures and polymerase chain reaction for 13 respiratory viruses, blood pneumococcal polymerase chain reaction, pneumococcal urinary antigen, PCT and CRP. Presumed pneumococcal CAP (P-CAP) was defined as a positive blood culture or polymerase chain reaction for Streptococcus pneumoniae or as a pneumococcal surface protein seroresponse (≥2-fold increase). RESULTS: Seventy-five patients were included from which 37 (49%) met the criteria of P-CAP. Elevated PCT and CRP values were strongly associated with P-CAP with odds ratios of 23 (95% confidence interval: 5-117) for PCT and 19 (95% confidence interval: 5-75) for CRP in multivariate analysis. The sensitivity was 94.4% for PCT (cutoff: 1.5 ng/mL) and 91.9% for CRP (cutoff: 100 mg/L). A value≤0.5 ng/mL of PCT ruled out P-CAP in >90% of cases (negative likelihood ratio: 0.08). Conversely, a PCT value≥1.5 ng/mL associated with a positive pneumococcal urinary antigen had a diagnostic probability for P-CAP of almost 80% (positive likelihood ratio: 4.59). CONCLUSIONS: PCT and CRP are reliable predictors of P-CAP. Low cutoff values of PCT allow identification of children at low risk of P-CAP. The association of elevated PCT or CRP with a positive pneumococcal urinary antigen is a strong predictor of P-CAP.
Resumo:
OBJECTIVE: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. METHODS: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. RESULTS: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.
Resumo:
Background: The Pulmonary Embolism Rule-out Criteria (PERC) rule is a clinical diagnostic rule designed to exclude pulmonary embolism (PE) without further testing. We sought to externally validate the diagnostic performance of the PERC rule alone and combined with clinical probability assessment based on the revised Geneva score. Methods: The PERC rule was applied retrospectively to consecutive patients who presented with a clinical suspicion of PE to six emergency departments, and who were enrolled in a randomized trial of PE diagnosis. Patients who met all eight PERC criteria [PERC(-)] were considered to be at a very low risk for PE. We calculated the prevalence of PE among PERC(-) patients according to their clinical pretest probability of PE. We estimated the negative likelihood ratio of the PERC rule to predict PE. Results: Among 1675 patients, the prevalence of PE was 21.3%. Overall, 13.2% of patients were PERC(-). The prevalence of PE was 5.4% [95% confidence interval (CI): 3.1-9.3%] among PERC(-) patients overall and 6.4% (95% CI: 3.7-10.8%) among those PERC(-) patients with a low clinical pretest probability of PE. The PERC rule had a negative likelihood ratio of 0.70 (95% CI: 0.67-0.73) for predicting PE overall, and 0.63 (95% CI: 0.38-1.06) in low-risk patients. Conclusions: Our results suggest that the PERC rule alone or even when combined with the revised Geneva score cannot safely identify very low risk patients in whom PE can be ruled out without additional testing, at least in populations with a relatively high prevalence of PE.