Resumo:

Tiotropium delivered at a dose of 5 μg with the Respimat inhaler showed efficacy similar to that of 18 μg of tiotropium delivered with the HandiHaler inhalation device in placebo-controlled trials involving patients with chronic obstructive pulmonary disease (COPD). Although tiotropium HandiHaler was associated with reduced mortality, as compared with placebo, more deaths were reported with tiotropium Respimat than with placebo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Lung deposition of intravenous cephalosporins is low. The lung deposition of equivalent doses of ceftazidime administered either intravenously or by ultrasonic nebulization using either nitrogen-oxygen or helium-oxygen as the carrying gas of the aerosol was compared in ventilated piglets with and without experimental bronchopneumonia. Methods: Five piglets with noninfected lungs and 5 piglets with Pseudomonas aeruginosa experimental bronchopneumonia received 33 mg/kg ceftazidime intravenously. Ten piglets with noninfected lungs and 10 others with experimental P. aeruginosa bronchopneumonia received 50 mg/kg ceftazidime by ultrasonic nebulization. In each group, the ventilator was operated in half of the animals with a 65%/35% helium-oxygen or nitrogen-oxygen mixture. Animals were killed, and multiple lung specimens were sampled for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography. Results: As compared with intravenous administration, nebulization of ceftazidime significantly increased lung tissue concentrations (17 ± 13 vs. 383 ± 84 μg/g in noninfected piglets and 10 ± 3 vs. 129 ± 108 μg/g in piglets with experimental bronchopneumonia; P < 0.001). The use of a 65%/35% helium-oxygen mixture induced a 33% additional increase in lung tissue concentrations in noninfected piglets (576 ± 141 μg/g; P < 0.001) and no significant change in infected piglets (111 ± 104 μg/g). Conclusion: Nebulization of ceftazidime induced a 5- to 30-fold increase in lung tissue concentrations as compared with intravenous administration. Using a helium-oxygen mixture as the carrying gas of the aerosol induced a substantial additional increase in lung deposition in noninfected piglets but not in piglets with experimental bronchopneumonia. © 2005 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To explore whether an association exists between health care professionals’ (HCPs) asthma knowledge and inhaler technique demonstration skills. Methods: HCPs’ asthma knowledge and inhaler technique demonstration skills were assessed at baseline at an inter-professional educational workshop focusing on asthma medication use. Asthma knowledge was assessed via a published questionnaire. Correct inhaler technique for the three inhalers, the Accuhaler, Turbuhaler and pressurized Metered Dose Inhaler (pMDI) was assessed using published checklists. Results: Two hundred HCPs agreed to participate: 10 specialists (medical doctors specialized in respiratory diseases) (5%), 46 general practitioners (23%), 79 pharmacists (39%), 15 pharmacists’ assistants (8%), 40 nurses (20%) and 10 respiratory therapists (5%). Backwards stepwise multiple regression conducted to determine predictors of HCPs’ inhaler technique, showed that out of many independent variables (asthma knowledge score, profession, age, gender, place of work, years in practice and previous personal use of the study inhaler/s), asthma knowledge score was the only variable showing significant association with inhaler technique (R²=0.162, p<0.001). Conclusion: This study revealed significant associations between asthma knowledge and inhaler technique scores for all HCPs. Providing inter-professional workshops for all HCPs involved integrating education on asthma knowledge and practice of inhaler technique skills are looked-for.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Burkholderia cepacia infection in cystic fibrosis (CF) patients is associated with significant morbidity and mortality, yet no definitive treatment is currently available. This report describes a new approach to treat B. cepacia infection in CF patients, using a combination of amiloride and tobramycin aerosols. Four adults with the typical clinical syndrome of CF were recruited after repeated positive sputum cultures for B. cepacia. Aerosols of amiloride and tobramycin were given three times daily for 1-6 months, and repeated sputum cultures were collected to assess efficacy. Three of the four patients treated with the combined therapy eradicated B. cepacia from their sputum cultures for at least 2 yrs, and there were no adverse events. This novel combination may provide a new therapeutic option for Burkholderia cepacia infections. Furthermore, the strategy of combining antibiotics with ion transport agents may have ramifications for the treatment of other multi-resistant organisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Asthma management guidelines advocate a stepwise approach to asthma therapy, including the addition of a long-acting bronchodilator to inhaled steroid therapy at step 3. This is almost exclusively prescribed as inhaled combination therapy.

AIMS: To examine whether asthma prescribing practice for inhaled combination therapy (inhaled corticosteroid/long-acting β2-agonist (ICS/LABA)) in primary care in Northern Ireland is in line with national asthma management guidelines.

METHODS: Using data from the Northern Ireland Enhanced Prescribing Database, we examined initiation of ICS/LABA in subjects aged 5-35 years in 2010.

RESULTS: A total of 2,640 subjects (67%) had no inhaled corticosteroid monotherapy (ICS) in the study year or six months of the preceding year (lead-in period) and, extending this to a 12-month lead-in period, 52% had no prior ICS. 41% of first prescriptions for ICS/LABA were dispensed in January to March. Prior to ICS/LABA prescription, in the previous six months only 17% had a short-acting β2-agonist (SABA) dispensed, 5% received oral steroids, and 17% received an antibiotic.

CONCLUSIONS: ICS/LABA therapy was initiated in the majority of young subjects with asthma without prior inhaled steroid therapy. Most prescriptions were initiated in the January to March period. However, the prescribing of ICS/LABA did not appear to be driven by asthma symptoms (17% received SABA in the previous 6 months) or severe asthma exacerbation (only 5% received oral steroids). Significant reductions in ICS/LABA, with associated cost savings, would occur if the asthma prescribing guidelines were followed in primary care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The emergence of electronic cigarettes (e-cigs) has given cannabis smokers a new method of inhaling cannabinoids. E-cigs differ from traditional marijuana cigarettes in several respects. First, it is assumed that vaporizing cannabinoids at lower temperatures is safer because it produces smaller amounts of toxic substances than the hot combustion of a marijuana cigarette. Recreational cannabis users can discretely "vape" deodorized cannabis extracts with minimal annoyance to the people around them and less chance of detection. There are nevertheless several drawbacks worth mentioning: although manufacturing commercial (or homemade) cannabinoid-enriched electronic liquids (e-liquids) requires lengthy, complex processing, some are readily on the Internet despite their lack of quality control, expiry date, and conditions of preservation and, above all, any toxicological and clinical assessment. Besides these safety problems, the regulatory situation surrounding e-liquids is often unclear. More simply ground cannabis flowering heads or concentrated, oily THC extracts (such as butane honey oil or BHO) can be vaped in specially designed, pen-sized marijuana vaporizers. Analysis of a commercial e-liquid rich in cannabidiol showed that it contained a smaller dose of active ingredient than advertised; testing our laboratory-made, purified BHO, however, confirmed that it could be vaped in an e-cig to deliver a psychoactive dose of THC. The health consequences specific to vaping these cannabis preparations remain largely unknown and speculative due to the absence of comprehensive, robust scientific studies. The most significant health concerns involve the vaping of cannabinoids by children and teenagers. E-cigs could provide an alternative gateway to cannabis use for young people. Furthermore, vaping cannabinoids could lead to environmental and passive contamination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Acute bronchiolitis is a common disorder of infants that often results in hospitalization. Apart from supportive care, no therapy has been shown to influence the course of the disease, except for a possible effect of nebulized hypertonic saline (HS). To determine whether this does have beneficial effects on length of stay in hospital or on severity scores, we undertook a double-blind, randomized, controlled trial in a pediatric department of a Portuguese hospital. METHODS: Previously healthy infants, younger than 12 months, hospitalized with mild-to-moderate acute viral bronchiolitis were randomized to receive either nebulized 3% (hypertonic, HS) or 0.9% (normal, NS) saline during their entire hospital stay. Primary endpoints were: length of hospital stay and severity scores on each day of hospitalization. Need for supplemental oxygen, further add-on medications and adverse effects were also analyzed. RESULTS: Sixty-eight patients completed the study (HS: 33; NS: 35). The median length of hospital stay did not differ between groups: HS: 5.6 ± 2.3 days; NS: 5.4 ± 2.1 days (P = 0.747). We found no difference between groups in severity scores from day 1 to day 4. There were no differences in need for supplemental oxygen or add-on medications. Patients in HS group had significantly more cough (46% vs. 20%, P = 0.025) and rhinorrhoe (58% vs. 31%, P = 0.30). CONCLUSION: This study does not support the use of nebulized HS over NS in therapy of hospitalized children with mild-to-moderate acute viral bronchiolitis

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lung disease in cystic fibrosis (CF) is typified by the development of chronic airways infection culminating in bronchiectasis and progression to end-stage respiratory disease. Pseudomonas aeruginosa, a ubiquitous gram-negative bacteria, is the archetypical CF pathogen and is associated with an accelerated clinical decline. The development and widespread use of chronic suppressive aerosolized antibacterial therapies, in particular Tobramycin Inhalation Solution (TIS), in CF has contributed to reduced lung function decline and improved survival. However, the requirement for the aerosolization of these agents through nebulizers has been associated with increased treatment burden, reduced quality of life and remain a barrier to broader uptake. Tobramycin Inhalation Powder (TIP™) has been developed by Novartis with the express purpose of delivering the same benefits as TIS in a time-effective manner. Administered via the T-326™ (Novartis) Inhaler in four individual 28-mg capsules, TIP can be administered in a quarter of the time of traditional nebulizers and is inherently portable. In clinical studies, TIP has been shown to be safe, result in equivalent or superior reductions in P. aeruginosa sputum density and produce similar improvements in pulmonary function. TIP offers significant advantages in time saving, portability and convenience over traditional nebulized TIS with comparable clinical outcomes for individuals with CF.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Background: Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. Aim: Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. Methods: Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer (Intersurgical(®) Cirrus(®)), and a pressurized metered dose inhaler (pMDI; GSK) with a detergent-coated holding chamber (AeroChamber(®) MV) in the premature infant nose throat-model (PrINT-model) of a 32-week preterm infant (1,750 g). A filter or an impactor was placed below the infant model's "trachea" to capture the drug dose or particle size, respectively, that would have been deposited in the lung. Results: Lung dose (percentage of nominal dose) was 1.5%, 6.8%, and 18.0-20.6% for the jet nebulizer, pMDI-holding chamber, and investigational eFlow nebulizers, respectively (p<0.001). Jet nebulizer residue was 69.4% and 10.7-13.9% for the investigational eFlow nebulizers (p<0.001). Adding an elbow extension between the eFlow and the model significantly lowered lung dose (p<0.001). A breathing pattern with lower tidal volume decreased deposition in the PrINT-model and device residue (p<0.05), but did not decrease lung dose. Conclusions: In a model for infant aerosol inhalation, we confirmed low lung dose using jet nebulizers and pMDI-holding chambers, whereas newer, more specialized vibrating membrane devices, designed specifically for use in preterm infants, deliver up to 20 times more drug to the infant's lung.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two Meinhard microconcentric nebulizers, model AR30-07-FM02 and AR 30-07-FM005, were employed as a self-installed micro-sampling system for inductively coupled plasma-mass spectrometry (ICP-MS). The FM02 nebulizer at 22 muL/min of solution uptake rate gave the relative standard deviations of 7.6%, 3.0%, 2.7%, 1.8% for determinations (n = 10) of 20 mug/L Be, Co, In and Bi, respectively, and the detection limits (3s) of 0.14, 0.10, 0.02 and 0.01 mug/L for Be, Co In and Bi, respectively. The mass intensity of In-115 obtained by this micro-sampling system was 60% of that by conventional pneumatic nebulizer system at 1.3 mL/min. The analytical results for La, Ce, Pr and Nd in 20 muL Wistar rat amniotic fluid obtained by the present micro-sampling system were precisely in good agreement with those obtained using conventional pneumatic nebulization system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.