47 resultados para NSM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the main features of finite element FE numerical model developed using the computer code FEMIX to predict the near-surface mounted NSM carbon-fiber-reinforced polymer CFRP rods shear repair contribution to corroded reinforced concrete RC beams. In the RC beams shear repaired with NSM technique, the Carbon Fibre Reinforced Polymer (CFRP) rods are placed inside pre-cut grooves onto the concrete cover of the RC beam’s lateral faces and are bonded to the concrete with high epoxy adhesive. Experimental and 3D numerical modelling results are presented in this paper in terms of load-deflection curves, and failure modes for 4 short corroded beams: two corroded beams (A1CL3-B and A1CL3-SB) and two control beams (A1T-B and A1T-SB), the beams noted with B were let repaired in bending only with NSM CFRP rods while the ones noted with SB were repaired in both bending and shear with NSM technique. The corrosion of the tensile steel bars and its effect on the shear capacity of the RC beams was discussed. Results showed that the FE model was able to capture the main aspects of the experimental load-deflection curves of the RC beams, moreover it has presented the experimental failure modes and FE numerical modelling crack patterns and both gave similar results for non-shear repaired beams which failed in diagonal tension mode of failure and for shear-repaired beams which failed due to large flexural crack at the middle of the beams along with the concrete crushing, three dimensional crack patterns were produced for shear-repaired beams in order to investigate the splitting cracks occurred at the middle of the beams and near the support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using prestressed near surface mounted fibre reinforced polymers (NSM-FRP) is nowadays regaining the attention from the scientific community for the strengthening of existing reinforced concrete (RC) structures. The application of prestressed internal FRP bars and externally bonded prestressed FRPs has already been deeply investigated and revealed considerable benefits when compared to the corresponding passive solutions. A certain amount of prestress provides benefits mainly associated to structural integrity and material durability. Immediately after prestress transference, it is possible to close some of the existing cracks, decreasing the susceptibility of the element to corrosion and, a certain amount of deflection can be recovered due to the creation of a negative curvature. However, very few studies have been carried out to properly assess the preservation of prestress over time. In this context, several reinforced concrete beams strengthened with prestressed NSM carbon FRP (CFRP) laminates were prestressed and monitored for about 40 days. The data obtained from these experimental programs is in this paper presented and analysed. The observed prestress losses were later modelled using finite elements analysis and, although this topic is not addressed in this paper, the obtained results revealed considerable precision. The largest strain losses in the CFRP laminate were found to be mainly located in the extremities of the bonded length, while in the central zone most of the applied pre-strain was retained over time. The highest CFRP strain losses were observed in the first 6 to 12 days after prestress transfer, suggesting that the application of prestressed NSM-FRP will be very effective over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the extensive research that has been conducted on the debonding behaviour of FRP strengthening systems, no standard methodology has been yet established on its experimental characterization. In this context, to assess the performance and reliability of small scale testing on NSM (near surface mounted) FRP strengthening systems, an experimental program was carried out on a series of nine NSM FRP strengthening systems, in the framework of an international Round Robin Testing (RRT). Eleven laboratories and seven manufacturers and suppliers participated in this extensive international exercise, which regarded both NSM and EBR FRP strengthening systems. Test results obtained for the NSM systems by the participating laboratories are discussed and compared in this paper to investigate the feasibility of the adopted single/double pulling shear test method, to investigate the mechanism of bond between NSM FRP reinforcement and concrete, and to investigate the level of variability obtained between the participating laboratories testing the same material batches. It is concluded that the tested variants in the adopted single/double shear pulling test have a significant influence, stressing the importance of the level of detail of standardized test protocols for bond verification. On overall, given the variants included in this study, the obtained variation in bond stress-slip behaviour between the laboratories remained fairly limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of prestressed near surface mounted fibre reinforced polymers (NSM-FRP) has been long acknowledged to be a suitable approach to strengthen and retrofit existing reinforced concrete structures. The application of a certain amount of prestress to the FRP prior to its installation provides a number of benefits, mainly related to crack width and deflection requisites at serviceability limit state conditions. After transferring the prestress to a structural element, some of the existing cracks can be closed, decreasing the vulnerability of the element to corrosion and, a certain amount of deflection can be recovered due to the introduced negative curvature. However, these benefits can only be assured if the prestress is properly preserved over time. In this context, three series of reinforced concrete beams, in a total of 10 beams, were strengthened with a prestressed carbon FRP laminate (CFRP) and monitored for about 40 days. The data obtained from these tests is in this paper presented and analysed. The observed losses of strain in the CFRP laminate were found to be mainly located in the extremities of the bonded length, while in the central zone most of the initial strain was well-preserved over time. Additionally, the highest CFRP strain losses were observed in the first 6 to 12 days after prestress transfer, suggesting that the benefits of prestressed NSM-FRP will not be considerably lost over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the main features of finite element FE numerical model developed using the computer code FEMIX to predict the near-surface mounted NSM carbon-fiber-reinforced polymer CFRP rods shear repair contribution to corroded reinforced concrete RC beams. In the RC beams shear repaired with NSM technique, the Carbon Fibre Reinforced Polymer (CFRP) rods are placed inside pre-cut grooves onto the concrete cover of the RC beam’s lateral faces and are bonded to the concrete with high epoxy adhesive. Experimental and 3D numerical modelling results are presented in this paper in terms of load-deflection curves, failure modes and slip information of the tensile steel bars for 4 short corroded beams: two corroded beams (A1CL3-B and A1CL3-SB) and two control beams (A1T-B and A1T-SB), the beams noted with B were let repaired in bending only with NSM CFRP rods while the ones noted with SB were repaired in both bending and shear with NSM technique. The corrosion of the tensile steel bars and its effect on the shear capacity of the RC beams was discussed. Results showed that the FE model was able to capture the main aspects of the experimental load-deflection curves of the RC beams, moreover it has presented the experimental failure modes and FE numerical modelling crack patterns and both gave similar results for non-shear repaired beams which failed in diagonal tension mode of failure and for shear-repaired beams which failed due to large flexural crack at the middle of the beams along with the concrete crushing, three dimensional crack patterns were produced for shear-repaired beams in order to investigate the splitting cracks occurred at the middle of the beams and near the support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an experimental program to assess the tensile strain distribution along prestressed carbon fiber reinforced polymer (CFRP) reinforcement flexurally applied on the tensile surface of RC beams according to near surface mounted (NSM) technique. Moreover, the current study aims to propose an analytical formulation, with a design framework, for the prediction of distribution of CFRP tensile strain and bond shear stress and, additionally, the prestress transfer length. After demonstration the good predictive performance of the proposed analytical approach, parametric studies were carried out to analytically evaluate the influence of the main material properties, and CFRP and groove cross section on the distribution of the CFRP tensile strain and bond shear stress, and on the prestress transfer length. The proposed analytical approach can also predict the evolution of the prestress transfer length during the curing time of the adhesive by considering the variation of its elasticity modulus during this period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of Near Surface Mounted (NSM) Fiber Reinforced Polymers (FRPs) for strengthening masonry structures can be a suitable substitute for Externally Bonded Reinforcement (EBR) technique. NSM technique has many advantages such as larger bonded area, better anchorage capacity, higher resistance, higher percentage exploitation of the FRP and reduced installation time. However, information regarding the effectiveness of this strengthening technique for masonry structures is scarce and characterization of the critical mechanisms such as bond behavior is necessary. This paper presents experimental investigation of the bond performance in NSM-strengthened brick specimens. CFRP laminates are used for NSM strengthening of masonry bricks with different bonded lengths. The bond between FRP and masonry substrate is investigated by performing conventional pull-out tests and the experimental results are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Timber frame buildings are well known as an efficient seismic resistant structure popular all over the world not only due to their seismic performance, but also to their low cost and the strength they offer. These constructions still exist today and it is important to be able to preserve them, so a better knowledge on their behaviour is sought. Furthermore, historic technologies could be used even in modern constructions to build seismic resistant buildings using more natural materials with lesser costs. A great rehabilitation effort is being carried out on this type of buildings, as their neglect has led to decay or their change in use and alterations to the structure has led to the need to retrofit such buildings; only recently studies on their behaviour have become available and only a few of them address the issue of possible strengthening techniques for this kind of walls. In this scope, an innovative retrofitting technique (near surface mounted steel flat bars) is proposed and validated on traditional timber frame walls based on an extensive experimental program. The results of the static cyclic tests on distinct wall typologies retrofitted with the NSM technique are herein presented and discussed in detail. The main features on deformation, lateral stiffness, lateral resistance and seismic performance indexes are analysed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decade the near-surface mounted (NSM) strengthening technique using carbon fibre reinforced polymers (CFRP) has been increasingly used to improve the load carrying capacity of concrete members. Compared to externally bonded reinforcement (EBR), the NSM system presents considerable advantages. This technique consists in the insertion of carbon fibre reinforced polymer laminate strips into pre-cut slits opened in the concrete cover of the elements to be strengthened. CFRP reinforcement is bonded to concrete with an appropriate groove filler, typically epoxy adhesive or cement grout. Up to now, research efforts have been mainly focused on several structural aspects, such as: bond behaviour, flexural and/or shear strengthening effectiveness, and energy dissipation capacity of beam-column joints. In such research works, as well as in field applications, the most widespread adhesives that are used to bond reinforcements to concrete are epoxy resins. It is largely accepted that the performance of the whole application of NSM systems strongly depends on the mechanical properties of the epoxy resins, for which proper curing conditions must be assured. Therefore, the existence of non-destructive methods that allow monitoring the curing process of epoxy resins in the NSM CFRP system is desirable, in view of obtaining continuous information that can provide indication in regard to the effectiveness of curing and the expectable bond behaviour of CFRP/adhesive/concrete systems. The experimental research was developed at the Laboratory of the Structural Division of the Civil Engineering Department of the University of Minho in Guimar\~aes, Portugal (LEST). The main objective was to develop and propose a new method for continuous quality control of the curing of epoxy resins applied in NSM CFRP strengthening systems. This objective is pursued through the adaptation of an existing technique, termed EMM-ARM (Elasticity Modulus Monitoring through Ambient Response Method) that has been developed for monitoring the early stiffness evolution of cement-based materials. The experimental program was composed of two parts: (i) direct pull-out tests on concrete specimens strengthened with NSM CFRP laminate strips were conducted to assess the evolution of bond behaviour between CFRP and concrete since early ages; and, (ii) EMM-ARM tests were carried out for monitoring the progressive stiffness development of the structural adhesive used in CFRP applications. In order to verify the capability of the proposed method for evaluating the elastic modulus of the epoxy, static E-Modulus was determined through tension tests. The results of the two series of tests were then combined and compared to evaluate the possibility of implementation of a new method for the continuous monitoring and quality control of NSM CFRP applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El refuerzo de elementos estructurales sometidos a flexión mediante la utilización de barras (FRP) pretensadas es una técnica novedosa. En el presente trabajo se describe una nueva técnica para efectuar dicho pretensado. Se describen además los resultados obtenidos en una campaña de ensayos con 9 vigas: 3 probetas sin refuerzo, 3 probetas con refuerzo pasivo y 3 probetas con refuerzo activo. Para conseguir una rotura a flexión las vigas fueron reforzadas a cortante con unos anillos de tejido de fibra de carbono. La rotura de las vigas testigo fue dúctil, y las vigas reforzadas rompieron a cortante de forma explosiva. El pretensado de los elementos de refuerzo permitió incrementar la capacidad resistente de las vigas un 170% respecto de la viga testigo, produciéndose además un aumento en la rigidez de los elementos reforzados y una disminución en la fisuración de la viga. Se detectaron deficiencias en la técnica de refuerzo empleada, derivadas principalmente del método de aplicación del adhesivo estructural, que se propone mejorar en próximos trabajos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El uso de refuerzos NSM‐FRP en estructuras de hormigón armado se ha incrementado considerablemente en los últimos años como método de refuerzo estructural. Los ensayos de arrancamiento en viga de los refuerzos NSM‐FRP permiten el estudio del comportamiento de la unión pegada. El principal objetivo del presente trabajo aborda la simulación numérica de este tipo de ensayos, con el propósito de caracterizar correctamente la adherencia entre las barras de NSM‐FRP y el hormigón. En una fase inicial se simuló un modelo bidimensional para conseguir evaluar y verificar el comportamiento de los elementos cohesivos y ver su comportamiento primero ante diferentes modelos de material y segundo ante un modo mixto de fallo, debido a la aplicación simultanea de carga axial y carga cortante. En una segunda fase se creó un modelo tridimensional para estudiar el arrancamiento de una barra de material compuesto insertada en hormigón, creando un modelo de material de hormigón y viendo el comportamiento cualitativo del sistema ante variaciones en los parámetros de los diferentes materiales. En la tercera fase, la más importante del presente trabajo, se abordó la simulación numérica del ensayo de arrancamiento en viga. Se simularon todos los componentes del ensayo y se evaluaron diferentes alternativas para representar la interfase NSM‐FRP ‐ hormigón, usando elementos cohesivos y diferentes distribuciones de los mismos en la interfase. Para conseguir representar lo más fielmente posible las condiciones del ensayo, se diseñó también un controlador PID que permite realizar las simulaciones numéricas mediante un control en desplazamientos, lo cual permite capturar más correctamente el comportamiento de reblandecimiento de la unión pegada. El controlador PID aplica técnicas de ingeniería de control para conseguir calcular a priori la amplitud necesaria del desplazamiento impuesto que provoque una evolución establecida en una variable interna del sistema. La variable usada para correlacionar los ensayos es la diferencia en desplazamientos entre dos puntos y se escoge una evolución lineal de la misma, pero en la tesis también se exponen los resultados de escoger otras posibles variables internas con diferentes evoluciones. Se compararon las simulaciones numéricas con resultados de mediciones experimentales previamente publicadas. Los resultados carga‐deslizamiento obtenidos encajan bien con los datos experimentales. El modelo propuesto es también capaz de predecir el modo de fallo en la interfase NSM‐FRP ‐ hormigón. Finalmente, también se han llevado a cabo estudios paramétricos, para evaluar la influencia de cada parámetro en los resultados. También se realizó un estudio cualitativo de cómo se comporta la unión pegada en cada momento de la simulación, mediante el uso macros y gráficas tridimensionales, para conseguir una mejor visualización y facilitar el análisis de los resultados. ABSTRACT The use of near‐surface mounted FRP reinforcement in reinforced concrete structures has seen a considerable increase in recent years as a strengthening method. Beam pull‐out tests for near‐surface reinforcement allow obtaining the local bond‐slip behavior of a bonded joint. The main objective of the current work deals with the three‐dimensional modeling of this kind of test with the purpose of characterizing suitably the mechanics of bond between FRP rods and concrete. In an initial stage, a two bidimensional in order to evaluate and to verify the behavior of the cohesive elements. Its behavior was evaluated first testing different material models and second testing the behavior when mixed mode failure appears, due to simultaneous axial and shear load. In a second stage a tridimensional model was created in order to study the pull‐out of an inserted beam of composite material in concrete. A concrete material model was created and the influence of each material parameter was studied qualitatively. The third part, the most relevant of the present work, the numerical simulation of the Beam Pull‐Out test was faced. All the parts of the Beam Pull‐Out test were included inthe simulation and different alternatives to represent the FRP bar – concrete interface have been evaluated, using cohesive elements and different distributions of them. In order to reproduce the test conditions more reliably, a PID controller has also been designed to conduct suitably the numerical tests in order to properly capture the softening branch of the load‐slip behaviour. The PID controller applies control techniques to calculate a priori the necessary amplitude of the load in order to achieve a given evolution through the simulation of an internal variable previously chosen. The variable used in order to correlate the simulation with the test results is the difference in displacements between two points and a linear evolution was chosen, but in the thesis the results of choosing other possible internal variables with different evolutions are also shown. The numerical FE simulations were compared with experimental measurements previously published. Load‐slip predictions compare well with the corresponding experimental data. The proposed model is also able to predict the failure mode at the FRP‐concrete interface. Some parametric studies have also been carried out, in order to evaluate the influence of each material parameter in the results. A qualitative study of the behaviour of the joint was also performed, using the results of the numeric simulations and through the use of macros and 3D graphs, the tensional state of each point of the joint can be visualized in each moment of the simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper explains and explores the concept of "semantic molecules" in the NSM methodology of semantic analysis. A semantic molecule is a complex lexical meaning which functions as an intermediate unit in the structure of other, more complex concepts. The paper undertakes an overview of different kinds of semantic molecule, showing how they enter into more complex meanings and how they themselves can be explicated. It shows that four levels of "nesting" of molecules within molecules are attested, and it argues that while some molecules such as 'hands' and 'make', may well be language-universal, many others are language-specific.