Background Recurrent nerve injury is 1 of the most important complications of thyroidectomy. During the last decade, nerve monitoring has gained increasing acceptance in several centers as a method to predict and to document nerve function at the end of the operation. We evaluated the efficacy of a nerve monitoring system in a series of patients who underwent thyroidectomy and critically analyzed the negative predictive value (NPV) and positive predictive value (PPV) of the method. Methods. NIM System efficacy was prospectively analyzed in 447 patients who underwent thyroidectomy between 2001 and 2008 (366 female/81 male; 420 white/47 nonwhite; 11 to 82 years of age; median, 43 years old). There were 421 total thyroidectomies and 26 partial thyroidectomies, leading to 868 nerves at risk. The gold standard to evaluate inferior laryngeal nerve function was early postoperative videolaryngoscopy, which was repeated after 4 to 6 months in all patients with abnormal endoscopic findings. Results. At the early evaluation, 858 nerves (98.8%) presented normal videolaryngoscopic features after surgery. Ten paretic/paralyzed nerves (1.2%) were detected (2 unexpected unilateral paresis, 2 unexpected bilateral paresis, 1 unexpected unilateral paralysis, 1 unexpected bilateral paralyses, and 1 expected unilateral paralysis). At the late videolaryngoscopy, only 2 permanent nerve paralyses were noted (0.2%), with an ultimate result of 99.8% functioning nerves. Nerve monitoring showed absent or markedly reduced electrical activity at the end of the operations in 25/868 nerves (2.9%), including all 10 endoscopically compromised nerves, with 15 false-positive results. There were no false-negative results. Therefore, the PPV was 40.0%, and the NPV was 100%. Conclusions. In the present series, nerve monitoring had a very high PPV but a low NPV for the detection of recurrent nerve injury. (C) 2011 Wiley Periodicals, Inc. Head Neck 34: 175-179, 2012
Resumo:
HYPOTHESIS Facial nerve monitoring can be used synchronous with a high-precision robotic tool as a functional warning to prevent of a collision of the drill bit with the facial nerve during direct cochlear access (DCA). BACKGROUND Minimally invasive direct cochlear access (DCA) aims to eliminate the need for a mastoidectomy by drilling a small tunnel through the facial recess to the cochlea with the aid of stereotactic tool guidance. Because the procedure is performed in a blind manner, structures such as the facial nerve are at risk. Neuromonitoring is a commonly used tool to help surgeons identify the facial nerve (FN) during routine surgical procedures in the mastoid. Recently, neuromonitoring technology was integrated into a commercially available drill system enabling real-time monitoring of the FN. The objective of this study was to determine if this drilling system could be used to warn of an impending collision with the FN during robot-assisted DCA. MATERIALS AND METHODS The sheep was chosen as a suitable model for this study because of its similarity to the human ear anatomy. The same surgical workflow applicable to human patients was performed in the animal model. Bone screws, serving as reference fiducials, were placed in the skull near the ear canal. The sheep head was imaged using a computed tomographic scanner and segmentation of FN, mastoid, and other relevant structures as well as planning of drilling trajectories was carried out using a dedicated software tool. During the actual procedure, a surgical drill system was connected to a nerve monitor and guided by a custom built robot system. As the planned trajectories were drilled, stimulation and EMG response signals were recorded. A postoperative analysis was achieved after each surgery to determine the actual drilled positions. RESULTS Using the calibrated pose synchronized with the EMG signals, the precise relationship between distance to FN and EMG with 3 different stimulation intensities could be determined for 11 different tunnels drilled in 3 different subjects. CONCLUSION From the results, it was determined that the current implementation of the neuromonitoring system lacks sensitivity and repeatability necessary to be used as a warning device in robotic DCA. We hypothesize that this is primarily because of the stimulation pattern achieved using a noninsulated drill as a stimulating probe. Further work is necessary to determine whether specific changes to the design can improve the sensitivity and specificity.
Resumo:
1.Pre-assessment data of the patient A 2-year-old boy, weighing 15 kg was admitted with a history of limited mouth opening(inter-incisor distance of 6 mm), hypoplastic and retrognathic mandible (bird face deformity) and facial asymmetry from left temporomandibular joint ankylosis (TMJA). He was born at term, after an uneventful pregnancy, and there was no report of trauma during caesarean section. No other possible aetiologies were identified. He was scheduled for mandibular osteotomy. Preoperative ENT examination revealed adenotonsillar hypertrophy. 2. Anaesthetic Plan A fiberoptic nasal intubation was performed under deep inhalation anaesthesia with sevoflurane, with the patient breathing spontaneously. Midazolam (0.05 mg.kg-1) and alfentanil (0.03 mg.kg-1) were given and anaesthesia was maintained with O2/air and sevoflurane. No neuromuscular blocking agent was administered since the surgical team needed facial nerve monitoring. 3. Description of incident During surgery an accidental extubation occurred and an attempt was made to reintubate the trachea by direct laryngoscopy. Although the osteotomy was nearly completed, the vocal cords could not be visualized (Cormack-Lehane grade IV laryngoscopic view). 4. Solving the problem Re-intubation was finally accomplished with the flexible fiberscope and the procedure was concluded without any more incidents. Extubation was performed 24 hours postoperatively with the patient fully awake. After surgery mouth opening improved to inter-incisor gap of 15 mm. 5. Lessons learned and take home message Two airways issues present in this case can lead to difficultventilation and intubation: TMJA and adenotonsillar hypertrophy. These difficulties were anticipated and managed accordingly. The accidental extubation brought to our attention the fact that, even after surgical correction, this airway remains challenging. Even with intensive jaw stretchingexercises there is a high incidence of re-ankylosis, especially in younger patients. One should bear that in mind when anaesthetizing patients with TMJA.
Resumo:
Purpose Corneal confocal microscopy (CCM) is a rapid non-invasive ophthalmic technique, which has been shown to diagnose and stratify the severity of diabetic neuropathy. Current morphometric techniques assess individual static images of the subbasal nerve plexus; this work explores the potential for non-invasive assessment of the wide-field morphology and dynamic changes of this plexus in vivo. Methods In this pilot study, laser scanning CCM was used to acquire maps (using a dynamic fixation target and semi-automated tiling software) of the central corneal sub-basal nerve plexus in 4 diabetic patients with and 6 without neuropathy and in 2 control subjects. Nerve migration was measured in an additional 7 diabetic patients with neuropathy, 4 without neuropathy and in 2 control subjects by repeating a modified version of the mapping procedure within 2-8 weeks, thus facilitating re-identification of distinctive nerve landmarks in the 2 montages. The rate of nerve movement was determined from these data and normalised to a weekly rate (µm/week), using customised software. Results Wide-field corneal nerve fibre length correlated significantly with the Neuropathy Disability Score (r = -0.58, p < 0.05), vibration perception (r = -0.66, p < 0.05) and peroneal conduction velocity (r = 0.67, p < 0.05). Central corneal nerve fibre length did not correlate with any of these measures of neuropathy (p > 0.05 for all). The rate of corneal nerve migration was 14.3 ± 1.1 µm/week in diabetic patients with neuropathy, 19.7 ± 13.3µm/week in diabetic patients without neuropathy, and 24.4 ± 9.8µm/week in control subjects; however, these differences were not significantly different (p = 0.543). Conclusions Our data demonstrate that it is possible to capture wide-field images of the corneal nerve plexus, and to quantify the rate of corneal nerve migration by repeating this procedure over a number of weeks. Further studies on larger sample sizes are required to determine the utility of this approach for the diagnosis and monitoring of diabetic neuropathy.
Resumo:
Purpose We examined the age-dependent alterations and longitudinal course of subbasal nerve plexus (SNP) morphology in healthy individuals. Methods Laser-scanning corneal confocal microscopy, ocular screening, and health and metabolic assessment were performed on 64 healthy participants at baseline and at 12-month intervals for 3 years. At each annual visit, eight central corneal images of the SNP were selected and analyzed using a fully-automated analysis system to quantify corneal nerve fiber length (CNFL). Two linear mixed model approaches were fitted to examine the relationship between age and CNFL, and the longitudinal changes of CNFL over three years. Results At baseline, mean age was 51.9 ± 14.7 years. The cohort was sex balanced (χ2 = 0.56, P = 0.45). Age (t = 1.6, P = 0.12) and CNFL (t = -0.50, P = 0.62) did not differ between sexes. A total of 52 participants completed the 36-month visit and 49 participants completed all visits. Age had a significant effect on CNFL (F1,33 = 5.67, P = 0.02) with a linear decrease of 0.05 mm/mm2 in CNFL per one year increase in age. No significant change in CNFL was observed over the 36-month period (F1,55 = 0.69, P = 0.41). Conclusions The CNFL showed a stable course over a 36-month period in healthy individuals, although there was a slight linear reduction in CNFL with age. The findings of this study have implications for understanding the time-course of the effect of pathology and surgical or therapeutic interventions on the morphology of the SNP, and serves to confirm the suitability of CNFL as a screening/monitoring marker for peripheral neuropathies.
Resumo:
Purpose The aim of this study was to determine alterations to the corneal subbasal nerve plexus (SNP) over four years using in vivo corneal confocal microscopy (IVCM) in participants with type 1 diabetes and to identify significant risk factors associated with these alterations. Methods A cohort of 108 individuals with type 1 diabetes and no evidence of peripheral neuropathy at enrollment underwent laser-scanning IVCM, ocular screening, and health and metabolic assessment at baseline and the examinations continued for four subsequent annual visits. At each annual visit, eight central corneal images of the SNP were selected and analyzed to quantify corneal nerve fiber density (CNFD), branch density (CNBD) and fiber length (CNFL). Linear mixed model approaches were fitted to examine the relationship between risk factors and corneal nerve parameters. Results A total of 96 participants completed the final visit and 91 participants completed all visits. No significant relationships were found between corneal nerve parameters and time, sex, duration of diabetes, smoking, alcohol consumption, blood pressure or BMI. However, CNFD was negatively associated with HbA1c (β=-0.76, P<0.01) and age (β=-0.13, P<0.01) and positively related to high density lipids (HDL) (β=2.01, P=0.03). Higher HbA1c (β=-1.58, P=0.04) and age (β=-0.23, P<0.01) also negatively impacted CNBD. CNFL was only affected by higher age (β=-0.06, P<0.01). Conclusions Glycemic control, HDL and age have significant effects on SNP structure. These findings highlight the importance of diabetic management to prevent corneal nerve damage as well as the capability of IVCM for monitoring subclinical alterations in the corneal SNP in diabetes.
Resumo:
-Aminobutyric acid type A (GABAA) receptors, a family of Cl-permeable ion channels, mediate fast synaptic inhibition as postsynaptically enriched receptors for -aminobutyric acid at GABAergic synapses. Here we describe an alternative type of inhibition mediated byGABAA receptors present on neocortical glutamatergic nerve terminals and examine the underlying signaling mechanism(s). By monitoring the activity of the presynaptic CaM kinase II/synapsin I signaling pathway in isolated nerve terminals, we demonstrate that GABAA receptor activation correlated with an increase in basal intraterminal [Ca2]i. Interestingly, this activation of GABAA receptors resulted in a reduction of subsequent depolarization-evoked Ca2 influx, which thereby led to an inhibition of glutamate release. To investigate how the observed GABAA receptor-mediated modulation operates, we determined the sensitivity of this process to the Na-K-2Cl cotransporter 1 antagonist bumetanide, as well as substitution of Ca2 with Ba2, or Ca2/calmodulin inhibition by W7. All of these treatments abolished the modulation by GABAA receptors. Application of selective antagonists of voltage-gated Ca2 channels (VGCCs) revealed that the GABAA receptor-mediated modulation of glutamate release required the specific activity of L- and R-type VGCCs. Crucially, the inhibition of release by these receptors was abolished in terminals isolated from R-type VGCC knock-out mice. Together, our results indicate that a functional coupling between nerve terminal GABAA receptors and L- or R-type VGCCs is mediated by Ca2/calmodulin-dependent signaling. This mechanism provides a GABA-mediated control of glutamatergic synaptic activity by a direct inhibition of glutamate release.
Resumo:
We used an assembly of electrodes C3 and C4-Cz in order to activate the motor cortical area of the corticobulbar tract to elucidate the motor-evoked potential of the contralateral mentalis muscle. We compared this setup to that of an assembly with electrodes C5 or C6-Cz using a train of electrical pulses and a single electrical pulse. This analysis was made in 23 consecutive patients who underwent several varied surgeries and were prospectively operated on at Santa Paula Hospital between January and June 2011. The results showed that the assembly with C5 or C6-Cz produced a multisynaptic motor-evoked potential in the contralateral mentalis muscle in 86.9 % of the patients, whereas 82.6 % of patients stimulated at points C3 or C4-Cz presented the same response. However, both assemblies showed similar behavior with the use of a single electrical pulse for peripheral contralateral nerve stimulation. We concluded that the C5 or C6-Cz assembly was similar to C3 or C4-Cz in obtaining a multisynaptic response in the contralateral mentalis muscle, although it required less intensive stimulation than the C3 or C4- Cz assembly.
Resumo:
BACKGROUND: Electrical stimulation of the P6 acupuncture point reduces the incidence of postoperative nausea and vomiting (PONV). Neuromuscular blockade during general anesthesia can be monitored with electrical peripheral nerve stimulation at the wrist. The authors tested the effect of neuromuscular monitoring over the P6 acupuncture point on the reduction of PONV. METHODS: In this prospective, double-blinded, randomized control trial, the authors investigated, with institutional review board approval and informed consent, 220 women undergoing elective laparoscopic surgery anesthetized with fentanyl, sevoflurane, and rocuronium. During anesthesia, neuromuscular blockade was monitored by a conventional nerve stimulator at a frequency of 1 Hz over the ulnar nerve (n = 110, control group) or over the median nerve (n = 110, P6 group) stimulating at the P6 acupuncture point at the same time. The authors evaluated the incidence of nausea and vomiting during the first 24 h. RESULTS: No differences in demographic and morphometric data were found between both groups. The 24-h incidence of PONV was 45% in the P6 acupuncture group versus 61% in the control group (P = 0.022). Nausea decreased from 56% in the control group to 40% in the P6 group (P = 0.022), but emesis decreased only from 28% to 23% (P = 0.439). Nausea decreased substantially during the first 6 h of the observation period (P = 0.009). Fewer subjects in the acupuncture group required ondansetron as rescue therapy (27% vs. 39%; P = 0.086). CONCLUSION: Intraoperative P6 acupuncture point stimulation with a conventional nerve stimulator during surgery significantly reduced the incidence of PONV over 24 h. The efficacy of P6 stimulation is similar to that of commonly used antiemetic drugs in the prevention of PONV.
Resumo:
Purpose: To determine whether curve-fitting analysis of the ranked segment distributions of topographic optic nerve head (ONH) parameters, derived using the Heidelberg Retina Tomograph (HRT), provide a more effective statistical descriptor to differentiate the normal from the glaucomatous ONH. Methods: The sample comprised of 22 normal control subjects (mean age 66.9 years; S.D. 7.8) and 22 glaucoma patients (mean age 72.1 years; S.D. 6.9) confirmed by reproducible visual field defects on the Humphrey Field Analyser. Three 10°-images of the ONH were obtained using the HRT. The mean topography image was determined and the HRT software was used to calculate the rim volume, rim area to disc area ratio, normalised rim area to disc area ratio and retinal nerve fibre cross-sectional area for each patient at 10°-sectoral intervals. The values were ranked in descending order, and each ranked-segment curve of ordered values was fitted using the least squares method. Results: There was no difference in disc area between the groups. The group mean cup-disc area ratio was significantly lower in the normal group (0.204 ± 0.16) compared with the glaucoma group (0.533 ± 0.083) (p < 0.001). The visual field indices, mean deviation and corrected pattern S.D., were significantly greater (p < 0.001) in the glaucoma group (-9.09 dB ± 3.3 and 7.91 ± 3.4, respectively) compared with the normal group (-0.15 dB ± 0.9 and 0.95 dB ± 0.8, respectively). Univariate linear regression provided the best overall fit to the ranked segment data. The equation parameters of the regression line manually applied to the normalised rim area-disc area and the rim area-disc area ratio data, correctly classified 100% of normal subjects and glaucoma patients. In this study sample, the regression analysis of ranked segment parameters method was more effective than conventional ranked segment analysis, in which glaucoma patients were misclassified in approximately 50% of cases. Further investigation in larger samples will enable the calculation of confidence intervals for normality. These reference standards will then need to be investigated for an independent sample to fully validate the technique. Conclusions: Using a curve-fitting approach to fit ranked segment curves retains information relating to the topographic nature of neural loss. Such methodology appears to overcome some of the deficiencies of conventional ranked segment analysis, and subject to validation in larger scale studies, may potentially be of clinical utility for detecting and monitoring glaucomatous damage. © 2007 The College of Optometrists.
Resumo:
BACKGROUND: Terrestrial Trunked Radio (TETRA) is a telecommunications system widely used by police and emergency services around the world. The Stewart Report on mobile telephony and health raised questions about possible health effects associated with TETRA signals. This study investigates possible effects of TETRA signals on the electroencephalogram and electrocardiogram in human volunteers. METHODS: Blinded randomized provocation study with a standardized TETRA signal or sham exposure. In the first of two experiments, police officers had a TETRA set placed first against the left temple and then the upper-left quadrant of the chest and the electroencephalogram was recorded during rest and active cognitive processing. In the second experiment, volunteers were subject to chest exposure of TETRA whilst their electroencephalogram and heart rate variability derived from the electrocardiogram were recorded. RESULTS: In the first experiment, we found that exposure to TETRA had consistent neurophysiological effects on the electroencephalogram, but only during chest exposure, in a pattern suggestive of vagal nerve stimulation. In the second experiment, we observed changes in heart rate variability during exposure to TETRA but the electroencephalogram effects were not replicated. CONCLUSIONS: Observed effects of exposure to TETRA signals on the electroencephalogram (first experiment) and electrocardiogram are consistent with vagal nerve stimulation in the chest by TETRA. However given the small effect on heart rate variability and the lack of consistency on the electroencephalogram, it seems unlikely that this will have a significant impact on health. Long-term monitoring of the health of the police force in relation to TETRA use is on-going.
Resumo:
Intraoperative neurophysiologic monitoring is an integral part of spinal surgeries and involves the recording of somatosensory evoked potentials (SSEP). However, clinical application of IONM still requires anywhere between 200 to 2000 trials to obtain an SSEP signal, which is excessive and introduces a significant delay during surgery to detect a possible neurological damage. The aim of this study is to develop a means to obtain the SSEP using a much less, twelve number of recordings. The preliminary step involved was to distinguish the SSEP with the ongoing brain activity. We first establish that the brain activity is indeed quasi-stationary whereas an SSEP is expected to be identical every time a trial is recorded. An algorithm was developed using Chebychev time windowing for preconditioning of SSEP trials to retain the morphological characteristics of somatosensory evoked potentials (SSEP). This preconditioning was followed by the application of a principal component analysis (PCA)-based algorithm utilizing quasi-stationarity of EEG on 12 preconditioned trials. A unique Walsh transform operation was then used to identify the position of the SSEP event. An alarm is raised when there is a 10% time in latency deviation and/or 50% peak-to-peak amplitude deviation, as per the clinical requirements. The algorithm shows consistency in the results in monitoring SSEP in up to 6-hour surgical procedures even under this significantly reduced number of trials. In this study, the analysis was performed on the data recorded in 29 patients undergoing surgery during which the posterior tibial nerve was stimulated and SSEP response was recorded from scalp. This method is shown empirically to be more clinically viable than present day approaches. In all 29 cases, the algorithm takes 4sec to extract an SSEP signal, as compared to conventional methods, which take several minutes. The monitoring process using the algorithm was successful and proved conclusive under the clinical constraints throughout the different surgical procedures with an accuracy of 91.5%. Higher accuracy and faster execution time, observed in the present study, in determining the SSEP signals provide a much improved and effective neurophysiological monitoring process.