972 resultados para N-1 safety criterion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Legislative Oversight Committee of the South Carolina House of Representatives, referred allegations pertaining to the Department of Juvenile Justice (DJJ) which were generated during its ongoing oversight study of DJJ. Specifically, the safety issues focused on lack of control; lack of trust; and lack of adequate staffing. This review’s scope and objectives were: Investigate specific complainant allegations of DJJ employees underreporting, misreporting, or destroying ERs; Review the efficiency and effectiveness of DJJ’s event reporting process and follow-up on anomalies or potential patterns of systemic underreporting, misreporting, or missing ERs; and Assess juvenile and employee safety conditions through interviewing a cross-section of relevant employees, record review, and possibly an employee survey.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hydroelectric power plant Hidroltuango represents a major expansion for the Colombian electrical system (with a total capacity of 2400 MW). This paper analyzes the possible interconnections and investments involved in connecting Hidroltuango, in order to strengthen the Colombian national transmission system. A Mixed Binary Linear Programming (MBLP) model was used to solve the Multistage Transmission Network Expansion Planning (MTEP) problem of the Colombian electrical system, taking the N-1 safety criterion into account. The N-1 safety criterion indicates that the transmission system must be expanded so that the system will continue to operate properly if an outage in a system element (within a pre-defined set of contingencies) occurs. The use of a MBLP model guaranteed the convergence with existing classical optimization methods and the optimal solution for the MTEP using commercial solvers. Multiple scenarios for generation and demand were used to consider uncertainties within these parameters. The model was implemented using the algebraic modeling language AMPL and solved using the commercial solver CPLEX. The proposed model was then applied to the Colombian electrical system using the planning horizon of 2018-2025. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introducción: La evaluación de tecnologías en salud aplicadas a la selección de un módulo de proteína para uso hospitalario, tiene como finalidad servir de apoyo en la elección de productos costo efectivos y seguros, con el fin de favorecer la toma de decisiones a los diferentes agentes que participan en la elección de alternativas terapéuticas, recomendadas en pacientes con necesidades elevadas de proteínas, como es el caso de la presente investigación. Objetivo: Aplicar un método matemático - multicriterio que permita evaluar los módulos de proteína disponibles en el mercado para la terapia nutricional institucional. Métodos: Se establecieron dos fases, una revisión de la literatura para establecer y priorizar los criterios de evaluación técnica de las diferentes ofertas de módulos de proteína, y dos se realizó una aplicación de un modelo matemático con el fin de considerar el modulo proteico para uso dentro de las instituciones hospitalarias, el cual consistió en la asignación de un valor a cada una de las variables mediante una escala diferencial semántica establecida, que permitieron calcular el peso porcentual de cada una de las variables, cuya sumatoria arrojo la calificación porcentual de cada alternativa. Resultados: Respecto a la búsqueda de criterios de evaluación técnica para las diferentes ofertas de módulos de proteína, en la literatura se identificaron las siguientes variables para evaluación, la naturaleza o equivalencia, condiciones de administración y uso, seguridad, y eficacia. La naturaleza se evaluó mediante la calificación del cómputo químico de aminoácidos corregido por digestibilidad proteica (PDCAAS) con un peso en la evaluación del 39.05%, en referencia a las condiciones de administración y uso se tuvo en cuenta factores incluidos en los sistemas de distribución por dosis unitaria con un peso del 27.61%, la eficacia fue definida por la tasa de eficiencia proteica (PER) la cual impacta el 19.53% de la calificación y finalmente, el criterio de seguridad con un 13.81% referente al empaque y etiquetado. Conclusiones: Al realizar la evaluación de cuatro alternativas de módulos de proteína, ofertadas por las diferentes casas farmacéuticas, la mayor puntuación correspondiente a las alternativas con una calificación superior al 90%, la obtuvieron dos alternativas de módulos de proteína para uso hospitalario, las cuales contienen proteínas del suero (“Whey”) y aminoácidos en combinaciones.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Transferring patients with ST-elevation myocardial infarction (STEMI) for primary percutaneous coronary intervention (PCI) from a community hospital to a PCI centre has been evaluated in randomised trials and shown to be safe and effective. A prolonged transfer time may restrict the benefit of this strategy. AIM: We sought to assess 1) safety of transfer from Neuchâtel to Berne, 2) time intervals of patients transferred either directly from on-site or after evaluation in the local emergency room, and 3) clinical long-term outcome. METHODS AND RESULTS: 42 patients with STEMI eligible for reperfusion therapy were prospectively included between January 2003 and June 2004. Twenty patients (48%, group 1) were directly transferred to the PCI centre from on-site. Twenty-two were transferred after initial treatment in the local emergency room: 11 patients (26%, group 2) presented spontaneously at the hospital and 11 patients (26%, group 3) were admitted by the rescue team. No major complication occurred during transport. Median transport time was 33 minutes. Median time from first healthcare contact to balloon consisted of 131 minutes in group 1, 158 minutes in group 2 and 174 minutes in group 3. The overall rate of Major Adverse Cardiac Events (MACE) at 6 months amounted to 9.5%. CONCLUSIONS: Transfer for primary PCI of our patients with acute STEMI was safe. Direct transfer from on-site to the PCI centre reduced the time of ischaemia. The overall MACE rate was low.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research is one of several ongoing studies conducted within the IT Professional Services (ITPS) research programme at Queensland University of Technology (QUT). In 2003, ITPS introduced the IS-Impact model, a measurement model for measuring information systems success from the viewpoint of multiple stakeholders. The model, along with its instrument, is robust, simple, yet generalisable, and yields results that are comparable across time, stakeholders, different systems and system contexts. The IS-Impact model is defined as “a measure at a point in time, of the stream of net benefits from the Information System (IS), to date and anticipated, as perceived by all key-user-groups”. The model represents four dimensions, which are ‘Individual Impact’, ‘Organizational Impact’, ‘Information Quality’ and ‘System Quality’. The two Impact dimensions measure the up-to-date impact of the evaluated system, while the remaining two Quality dimensions act as proxies for probable future impacts (Gable, Sedera & Chan, 2008). To fulfil the goal of ITPS, “to develop the most widely employed model” this research re-validates and extends the IS-Impact model in a new context. This method/context-extension research aims to test the generalisability of the model by addressing known limitations of the model. One of the limitations of the model relates to the extent of external validity of the model. In order to gain wide acceptance, a model should be consistent and work well in different contexts. The IS-Impact model, however, was only validated in the Australian context, and packaged software was chosen as the IS understudy. Thus, this study is concerned with whether the model can be applied in another different context. Aiming for a robust and standardised measurement model that can be used across different contexts, this research re-validates and extends the IS-Impact model and its instrument to public sector organisations in Malaysia. The overarching research question (managerial question) of this research is “How can public sector organisations in Malaysia measure the impact of information systems systematically and effectively?” With two main objectives, the managerial question is broken down into two specific research questions. The first research question addresses the applicability (relevance) of the dimensions and measures of the IS-Impact model in the Malaysian context. Moreover, this research question addresses the completeness of the model in the new context. Initially, this research assumes that the dimensions and measures of the IS-Impact model are sufficient for the new context. However, some IS researchers suggest that the selection of measures needs to be done purposely for different contextual settings (DeLone & McLean, 1992, Rai, Lang & Welker, 2002). Thus, the first research question is as follows, “Is the IS-Impact model complete for measuring the impact of IS in Malaysian public sector organisations?” [RQ1]. The IS-Impact model is a multidimensional model that consists of four dimensions or constructs. Each dimension is represented by formative measures or indicators. Formative measures are known as composite variables because these measures make up or form the construct, or, in this case, the dimension in the IS-Impact model. These formative measures define different aspects of the dimension, thus, a measurement model of this kind needs to be tested not just on the structural relationship between the constructs but also the validity of each measure. In a previous study, the IS-Impact model was validated using formative validation techniques, as proposed in the literature (i.e., Diamantopoulos and Winklhofer, 2001, Diamantopoulos and Siguaw, 2006, Petter, Straub and Rai, 2007). However, there is potential for improving the validation testing of the model by adding more criterion or dependent variables. This includes identifying a consequence of the IS-Impact construct for the purpose of validation. Moreover, a different approach is employed in this research, whereby the validity of the model is tested using the Partial Least Squares (PLS) method, a component-based structural equation modelling (SEM) technique. Thus, the second research question addresses the construct validation of the IS-Impact model; “Is the IS-Impact model valid as a multidimensional formative construct?” [RQ2]. This study employs two rounds of surveys, each having a different and specific aim. The first is qualitative and exploratory, aiming to investigate the applicability and sufficiency of the IS-Impact dimensions and measures in the new context. This survey was conducted in a state government in Malaysia. A total of 77 valid responses were received, yielding 278 impact statements. The results from the qualitative analysis demonstrate the applicability of most of the IS-Impact measures. The analysis also shows a significant new measure having emerged from the context. This new measure was added as one of the System Quality measures. The second survey is a quantitative survey that aims to operationalise the measures identified from the qualitative analysis and rigorously validate the model. This survey was conducted in four state governments (including the state government that was involved in the first survey). A total of 254 valid responses were used in the data analysis. Data was analysed using structural equation modelling techniques, following the guidelines for formative construct validation, to test the validity and reliability of the constructs in the model. This study is the first research that extends the complete IS-Impact model in a new context that is different in terms of nationality, language and the type of information system (IS). The main contribution of this research is to present a comprehensive, up-to-date IS-Impact model, which has been validated in the new context. The study has accomplished its purpose of testing the generalisability of the IS-Impact model and continuing the IS evaluation research by extending it in the Malaysian context. A further contribution is a validated Malaysian language IS-Impact measurement instrument. It is hoped that the validated Malaysian IS-Impact instrument will encourage related IS research in Malaysia, and that the demonstrated model validity and generalisability will encourage a cumulative tradition of research previously not possible. The study entailed several methodological improvements on prior work, including: (1) new criterion measures for the overall IS-Impact construct employed in ‘identification through measurement relations’; (2) a stronger, multi-item ‘Satisfaction’ construct, employed in ‘identification through structural relations’; (3) an alternative version of the main survey instrument in which items are randomized (rather than blocked) for comparison with the main survey data, in attention to possible common method variance (no significant differences between these two survey instruments were observed); (4) demonstrates a validation process of formative indexes of a multidimensional, second-order construct (existing examples mostly involved unidimensional constructs); (5) testing the presence of suppressor effects that influence the significance of some measures and dimensions in the model; and (6) demonstrates the effect of an imbalanced number of measures within a construct to the contribution power of each dimension in a multidimensional model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis presents methods for incrementally constructing controllers in the presence of uncertainty and nonlinear dynamics. The basic setting is motion planning subject to temporal logic specifications. Broadly, two categories of problems are treated. The first is reactive formal synthesis when so-called discrete abstractions are available. The fragment of linear-time temporal logic (LTL) known as GR(1) is used to express assumptions about an adversarial environment and requirements of the controller. Two problems of changes to a specification are posed that concern the two major aspects of GR(1): safety and liveness. Algorithms providing incremental updates to strategies are presented as solutions. In support of these, an annotation of strategies is developed that facilitates repeated modifications. A variety of properties are proven about it, including necessity of existence and sufficiency for a strategy to be winning. The second category of problems considered is non-reactive (open-loop) synthesis in the absence of a discrete abstraction. Instead, the presented stochastic optimization methods directly construct a control input sequence that achieves low cost and satisfies a LTL formula. Several relaxations are considered as heuristics to address the rarity of sampling trajectories that satisfy an LTL formula and demonstrated to improve convergence rates for Dubins car and single-integrators subject to a recurrence task.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.

Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.

Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.

Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The Velocity Sourced Series Elastic Actuator has been proposed as a method for providing safe force or torque based actuation for robots without compromising the actuator performance. In this paper we assess the safety of Velocity Sourced Series Elastic Actuators by measuring the Head Injury Criterion scores for collisions with a model head. The study makes a comparative analysis against stiff, high impedance actuation using the same motor without the series elastic component, showing that the series elastic component brings about a massive reduction in the chance of head injury. The benefits of a collision detection and safe reaction system are shown to be limited to collisions at low speeds, providing greater interaction comfort but not necessarily contributing to safety from injury.