894 resultados para Nível freático
Resumo:
The objective of this study was to determine the influence of five different water levels on the crop development of Calla. The crop parameters evaluated were leaf area and evapotranspiration. The study was conducted in glass greenhouse with 50% of sunlight reduction. The plants were grown in PVC pots with 150 mm diameter, which were filled with substrate. The plant tubers weighed from 10 g to 12 g. The pots were placed within containers, under water level constant automatically.. The table water levels used were 10, 17, 24, 31 and 38 cm. Nine evaluations during the growth cycle checked the growth development. The evaporation varied from 26.89 to 46.14 L.plant-1 for 38 and 10 cm water levels, respectively and leaf area per plant showed 1011.6 to 2016.3 for the same levels. The substrate water was more available in the treatment 24 cm, with more restrictions in the upper and lower treatments. There was positive correlation between leaf area and evapotranspiration at the final of the culture.
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Partindo da premissa de que não só o nível freático acompanha a linha topográfica do terreno, mas também a direcção de escorrência das bacias subterrâneas tende a coincidir com a direcção predominante de escorrência das bacias hidrográficas à superfície, principalmente em aquíferos fracturados, foi realizado um estudo com o objectivo de definir um modelo explicativo do nível freático no sistema aquífero Estremoz-Cano e no sector pouco produtivo das rochas ígneas e metamórficas da Zona de Ossa Morena (ZOM), em função das característica métricas do terreno, aferidas a partir da uma análise espacial raster, com multi-resolução, gradativa e interpolativa. Diferentes modelos foram criados e testados a partir dos dados do nível hidroestático, da elevação do terreno e de indíces métricos do terreno computados a partir de uma superfície digital de terreno hidrologicamente funcional. A análise estatística das variáveis independentes computadas permitiu concluir que o nível hidrostático (NHE) é extremamente correlacionável com o índice de convexidade calculado (Convex) e a elevação do terreno numa Regressão Linear do Tipo Piecewise.
Resumo:
Because the penetration depth of Ground Penetrating Radar (GPR) signals is very limited in high conductive soils, the usefullness of this method in tropical regions is not yet completly known. The main objective of this researh is to test the usefullness of the method in Brazil. Two typical problems where GPR has been used in Europe and North American were choosed for this test: the first one is to characterize the internal structures of a sand body and the second problem is the localization of old buried pipes lines. The first test was done near the city of São Bento do Norte, in the northern coast of Rio Grande do Norte state, NE Brazil. In this region, there is a sand dune that is migrating very fast in the direction of adjacent settling areas. To characterize the internal structure of the dune and its relationship to the prevailing wind direction, as a preliminary step to understand the dune migration, GPR profiles using the 400 MHz frequency were performed in E-W, N-S, NE-SW, and SE-NW directions over the sand dune intersecting at the top of the dune. The practical resolution of the GPR data is around 30 cm; this was sufficient to distinguish individual foresets inside the dune. After applying the elevation correction to the data, we identified that dips of bedding structures are smallest for the N-S profile, which is perpendicular to the dominant wind direction, largest for the E-W profile, and intermediate for the SW-NE and SE-NW profiles. Foresets in the E-W profile dip with angles varying from 2 to 6 degrees. In the E-W profile, the water table and a horizontal truncation interface separating two generations of dunes were identified, as well as an abrupt directional change in the foreset patterns associated to a lateral contact between two dune generations, the older one extending to the west. The used high frequency of 400 Mhz does not allow a penetration deep enough to map completely these internal contacts. The second test was done near Estreito, a small town near Carnaúbais city, also in Rio Grande do Norte state. In this locality, there are several old pipe lines buried in area covered by plantations where digging should be minimized. Several GPR profiles using the 400 and 200 MHz frequency were performed trying to intercept perpendicularly the possible pipe lines. Because of the high conductivity of the soil, the raw original data can hardly be use to identify the pipe lines. However, after an adequate processing over the 200 MHz profiles, six pipe lines were identified. As a global result of the tests, GPR can be very usefull if the conductivity of the ground is low or, in the case of medium conductivities of the soils, if adequate processing is performed
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)