997 resultados para Myopia control
Resumo:
Objective. To evaluate the degree of axial elongation with soft radial refractive gradient (SRRG) contact lenses, orthokeratology (OK), and single vision (SV) spectacle lenses (control) during a period of 1 year before treatment and 2 years after treatment. Methods. This was a prospective, longitudinal, nonrandomized study. The study groups consisted of 30, 29, and 41 children, respectively. The axial length (AL) was measured during 2 years after recruitment and lens fitting. Results. The baseline refractive sphere was correlated significantly (r 2 = 0.542; P < 0.0001) with the amount of myopia progression before baseline. After 2 years, the mean myopia progression values for the SRRG, OK, and SV groups were −0.56 ± 0.51, −0.32 ± 0.53, and −0.98 ± 0.58 diopter, respectively. The results represent reductions in myopic progression of 43% and 67% for the SRRG and OK groups, respectively, compared to the SV group. The AL increased more in the SV group compared to the SRRG and OK groups, with 27% and 38% lower axial elongation, respectively, compared to the SV group at the 2-year visit (P < 0.05). SRRG and OK showed no differences (P = 0.430). Conclusion. The SRRG lens significantly decreased AL elongation compared to the SV control group. The SRRG lens was similarly effective to OK in preventing myopia progression in myopic children and adolescent.
Resumo:
PURPOSE. To compare axial length growth between white children with myopia wearing orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) over a 2-year period. METHODS. Subjects 6 to 12 years of age with myopia -0.75 to -4.00 diopters of sphere (DS) and astigmatism ≤1.00 diopters of cylinder (DC) were prospectively allocated OK or SV correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals. RESULTS. Thirty-one children were fitted with OK and 30 with SV. Following 24 months, axial length increased significantly over time for both the OK group (0.47 mm) and SV group (0.69 mm; P < 0.001), with a significant interaction between time and group (P = 0.05) reflecting a greater increase in the SV group. Significant differences in refraction were found over time, between groups and for the interaction between time and group for spherical (all P < 0.001) but not cylindrical components of refraction (all P > 0.05). Significantly greater corneal flattening was evident in the OK group for the flatter and steeper corneal powers and for corneal shape factor (all P ≤0.05). CONCLUSIONS. Orthokeratology contact lens wear reduces axial elongation in comparison to distance single-vision spectacles in children. © 2012 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
Purpose: To compare vision-related quality-of-life measures between children wearing orthokeratology (OK) contact lenses and distance single-vision (SV) spectacles. Methods: Subjects 6 to 12 years of age and with myopia of -0.75 to -4.00 diopters and astigmatism less than or equal to 1.00 diopters were prospectively assigned OK contact lens or SV spectacle correction. A pediatric refractive error profile questionnaire was administered at 12- and 24-month intervals to evaluate children's perceptions in terms of overall vision, near vision, far distance vision, symptoms, appearance, satisfaction, activities, academic performance, handling, and peer perceptions. The mean score of all items was calculated as the overall score. Additionally, parents/guardians were asked to rate their child's mode of visual correction and their intention to continue treatment after study completion. Results: Thirty-one children were fitted with OK contact lenses and 30 with SV spectacles. Children wearing OK contact lenses rated overall vision, far distance vision, symptoms, appearance, satisfaction, activities, academic performance, handling, peer perceptions, and the overall score significantly better than children wearing SV spectacles (all P<0.05). Near vision and handling were, respectively, rated better (P<0.001) and similar (P=0.44) for SV spectacles in comparison to OK contact lenses. No significant differences were found between 12 and 24 months for any of the subjective ratings assessed (all P>0.05). Parents/guardians of children wearing OK contact lenses rated visual correction method and intention to continue treatment higher than parents of children wearing SV spectacles (P=0.01). Conclusion: The results indicate that the significant improvement in vision-related quality of life and acceptability with OK contact lenses is an incentive to engage in its use for the control of myopia in children.
Resumo:
Editorial
Resumo:
Purpose: To describe the stabilization of early adult-onset myopia in three university students after initiating orthokeratology treatment with corneal refractive therapy contact lenses. Methods: Three Caucasian early adult-onset progressing myopic subjects (1 male, 2 females) were fitted with corneal refractive therapy lenses to correct myopia between ?1.50 and ?2.50 D of sphere using Paragon CRT (Paragon Vision Sciences, Mesa, AZ)lenses for overnight orthokeratology. The pre-treatment refractive history from 2005 as well as refraction and axial length after treatment onset are reported over a period of 3 years between December 2009 and January 2013 with an additional year of follow-up after treatment discontinuation (January–December 2013). The peripheral refractive patterns and topographic changes are also reported individually. Results: Treatment was successful in all three subjects achieving uncorrected visual acuity of 20/20 or better monocularly. During a period of 3 years of follow-up the subjects did not experience progression in their refractive error, nor in their axial length (measured during the last 2 years of treatment and 1 year after discontinuation). Furthermore, the subjects recovered to their baseline refraction and did not progressed further over the following year after lens wear discontinuation. Conclusions: We cannot attribute a causative effect to the orthokeratology treatment alone as underlying mechanism for myopia stabilization in this 3 patients. However, the present report points to the possibility of stabilization of early adult-onset myopia progression in young adults using corneal refractive therapy treatment.
Resumo:
PURPOSE: Myopia is a global public health issue; however, no information exists as to how potential myopia retardation strategies are being adopted globally. METHODS: A self-administrated, internet-based questionnaire was distributed in six languages, through professional bodies to eye care practitioners globally. The questions examined: awareness of increasing myopia prevalence, perceived efficacy and adoption of available strategies, and reasons for not adopting specific strategies. RESULTS: Of the 971 respondents, concern was higher (median 9/10) in Asia than in any other continent (7/10, p<0.001) and they considered themselves more active in implementing myopia control strategies (8/10) than Australasia and Europe (7/10), with North (4/10) and South America (5/10) being least proactive (p<0.001). Orthokeratology was perceived to be the most effective method of myopia control, followed by increased time outdoors and pharmaceutical approaches, with under-correction and single vision spectacles felt to be the least effective (p<0.05). Although significant intra-regional differences existed, overall most practitioners 67.5 (±37.8)% prescribed single vision spectacles or contact lenses as the primary mode of correction for myopic patients. The main justifications for their reluctance to prescribe alternatives to single vision refractive corrections were increased cost (35.6%), inadequate information (33.3%) and the unpredictability of outcomes (28.2%). CONCLUSIONS: Regardless of practitioners' awareness of the efficacy of myopia control techniques, the vast majority still prescribe single vision interventions to young myopes. In view of the increasing prevalence of myopia and existing evidence for interventions to slow myopia progression, clear guidelines for myopia management need to be established.
Resumo:
FULL TEXT: Like many people one of my favourite pastimes over the holiday season is to watch the great movies that are offered on the television channels and new releases in the movie theatres or catching up on those DVDs that you have been wanting to watch all year. Recently we had the new ‘Star Wars’ movie, ‘The Force Awakens’, which is reckoned to become the highest grossing movie of all time, and the latest offering from James Bond, ‘Spectre’ (which included, for the car aficionados amongst you, the gorgeous new Aston Martin DB10). It is always amusing to see how vision correction or eye injury is dealt with by movie makers. Spy movies and science fiction movies have a freehand to design aliens with multiples eyes on stalks or retina scanning door locks or goggles that can see through walls. Eye surgery is usually shown in some kind of day case simplified laser treatment that gives instant results, apart from the great scene in the original ‘Terminator’ movie where Arnold Schwarzenegger's android character encounters an injury to one eye and then proceeds to remove the humanoid covering to this mechanical eye over a bathroom sink. I suppose it is much more difficult to try and include contact lenses in such movies. Although you may recall the film ‘Charlie's Angels’, which did have a scene where one of the Angels wore a contact lens that had a retinal image imprinted on it so she could by-pass a retinal scan door lock and an Eddy Murphy spy movie ‘I-Spy’, where he wore contact lenses that had electronic gadgetry that allowed whatever he was looking at to be beamed back to someone else, a kind of remote video camera device. Maybe we aren’t quite there in terms of devices available but these things are probably not the behest of science fiction anymore as the technology does exist to put these things together. The technology to incorporate electronics into contact lenses is being developed and I am sure we will be reporting on it in the near future. In the meantime we can continue to enjoy the unrealistic scenes of eye swapping as in the film ‘Minority Report’ (with Tom Cruise). Much more closely to home, than in a galaxy far far away, in this issue you can find articles on topics much nearer to the closer future. More and more optometrists in the UK are becoming registered for therapeutic work as independent prescribers and the number is likely to rise in the near future. These practitioners will be interested in the review paper by Michael Doughty, who is a member of the CLAE editorial panel (soon to be renamed the Jedi Council!), on prescribing drugs as part of the management of chronic meibomian gland dysfunction. Contact lenses play an active role in myopia control and orthokeratology has been used not only to help provide refractive correction but also in the retardation of myopia. In this issue there are three articles related to this topic. Firstly, an excellent paper looking at the link between higher spherical equivalent refractive errors and the association with slower axial elongation. Secondly, a paper that discusses the effectiveness and safety of overnight orthokeratology with high-permeability lens material. Finally, a paper that looks at the stabilisation of early adult-onset myopia. Whilst we are always eager for new and exciting developments in contact lenses and related instrumentation in this issue of CLAE there is a demonstration of a novel and practical use of a smartphone to assisted anterior segment imaging and suggestions of this may be used in telemedicine. It is not hard to imagine someone taking an image remotely and transmitting that back to a central diagnostic centre with the relevant expertise housed in one place where the information can be interpreted and instruction given back to the remote site. Back to ‘Star Wars’ and you will recall in the film ‘The Phantom Menace’ when Qui-Gon Jinn first meets Anakin Skywalker on Tatooine he takes a sample of his blood and sends a scan of it back to Obi-Wan Kenobi to send for analysis and they find that the boy has the highest midichlorian count ever seen. On behalf of the CLAE Editorial board (or Jedi Council) and the BCLA Council (the Senate of the Republic) we wish for you a great 2016 and ‘may the contact lens force be with you’. Or let me put that another way ‘the CLAE Editorial Board and BCLA Council, on behalf of, a great 2016, we wish for you!’
Resumo:
As we settle into a new year, this second issue of Contact Lens and Anterior Eye allows us to reflect on how new research in this field impacts our understanding, but more importantly, how we use this evidence basis to enhance our day to day practice, to educate the next generation of students and to construct the research studies to deepen our knowledge still further. The end of 2014 saw the publication of the UK governments Research Exercise Framework (REF) which ranks Universities in terms of their outputs (which includes their paper, publications and research income), environment (infrastructure and staff support) and for the first time impact (defined as “any effect on, change or benefit to the economy, society, culture, public policy or services, health, the environment or quality of life, beyond academia” [8]). The REF is a process of expert review, carried out in 36 subject-based units of assessment, of which our field is typically submitted to the Allied Health, Dentistry, Nursing and Pharmacy panel. Universities that offer Optometry did very well with Cardiff, Manchester and Aston in the top 10% out of the 94 Universities that submitted to this panel (Grade point Average ranked order). While the format of the new exercise (probably in 2010) to allocate the more than £2 billion of UK government research funds is yet to be determined, it is already rumoured that impact will contribute an even larger proportion to the weighting. Hence it is even more important to reflect on the impact of our research. In this issue, Elisseef and colleagues [5] examine the intriguing potential of modifying a lens surface to allow it to bind to known wetting agents (in this case hyaluronic acid) to enhance water retention. Such a technique has the capacity to reduced friction between the lens surface and the eyelids/ocular surface, presumably leading to higher comfort and less reason for patients to discontinue with lens wear. Several papers in this issue report on the validity of new high precision, fast scanning imaging and quantification equipment, utilising techniques such as Scheimpflug, partial coherence interferometry, aberrometry and video allowing detailed assessment of anterior chamber biometry, corneal topography, corneal biomechanics, peripheral refraction, ocular aberrations and lens fit. The challenge is how to use this advanced instrumentation which is becoming increasingly available to create real impact. Many challenges in contact lenses and the anterior eye still prevail in 2015 such as: -While contact lens and refractive surgery complications are relatively rare, they are still too often devastating to the individual and their quality of life (such as the impact and prognosis of patients with Acanthmoeba Keratitis reported by Jhanji and colleagues in this issue [7]). How can we detect those patients who are going to be affected and what modifications do we need to make to contact lenses and patient management prevent this occurring? -Drop out from contact lenses still occurs at a rapid rate and symptoms of dry eye seem to be the leading cause driving this discontinuation of wear [1] and [2]. What design, coating, material and lubricant release mechanism will make a step change in end of day comfort in particular? -Presbyopia is a major challenge to hassle free quality vision and is one of the first signs of ageing noticed by many people. As an emmetrope approaching presbyopia, I have a vested interest in new medical devices that will give me high quality vision at all distances when my arms won’t stretch any further. Perhaps a new definition of presbyopia could be when you start to orientate your smartphone in the landscape direction to gain the small increase in print size needed to read! Effective accommodating intraocular lenses that truly mimic the pre-presbyopic crystalline lenses are still a way off [3] and hence simultaneous images achieved through contact lenses, intraocular lenses or refractive surgery still have a secure future. However, splitting light reaching the retina and requiring the brain to supress blurred images will always be a compromise on contrast sensitivity and is liable to cause dysphotopsia; so how will new designs account for differences in a patient's task demands and own optical aberrations to allow focused patient selection, optimising satisfaction? -Drug delivery from contact lenses offers much in terms of compliance and quality of life for patients with chronic ocular conditions such as glaucoma, dry eye and perhaps in the future, dry age-related macular degeneration; but scientific proof-of-concept publications (see EIShaer et al. [6]) have not yet led to commercial products. Part of this is presumably the regulatory complexity of combining a medical device (the contact lens) and a pharmaceutical agent. Will 2015 be the year when this innovation finally becomes a reality for patients, bringing them an enhanced quality of life through their eye care practitioners and allowing researchers to further validate the use of pharmaceutical contact lenses and propose enhancements as the technology matures? -Last, but no means least is the field of myopia control, the topic of the first day of the BCLA's Conference in Liverpool, June 6–9th 2015. The epidemic of myopia is a blight, particularly in Asia, with significant concerns over sight threatening pathology resulting from the elongated eye. This is a field where real impact is already being realised through new soft contact lens optics, orthokeratology and low dose pharmaceuticals [4], but we still need to be able to better predict which technique will work best for an individual and to develop new techniques to retard myopia progression in those who don’t respond to current treatments, without increasing their risk of complications or the treatment impacting their quality of life So what will your New Year's resolution be to make 2015 a year of real impact, whether by advancing science or applying the findings published in journals such as Contact Lens and Anterior Eye to make a real difference to your patients’ lives?
Resumo:
Purpose: The Shin-Nippon SRW-5000 is an open view autorefractor that superseded the Canon R-1 autorefractor in the mid-1990s and has been used widely in optometry and vision science laboratories. It has been used to measure refractive error, accommodation responses both statically and dynamically, off-axis refractive error, and adapted to measure pupil size. This paper presents an overview of the original 2001 clinical evaluation of the SRW-5000 in adults (Mallen et al., Ophthal Physiol Opt 2001; 21: 101) and provides an update on the use and modification of the instrument since the original publication. Recent findings: The SRW-5000 instrument, and the family of devices which followed, have shown excellent validity, repeatability, and utility in clinical and research settings. The instruments have also shown great potential for increased research functionality following a number of modifications. Summary: The SRW-5000 and its derivatives have been, and continue to be, of significant importance in our drive to understand myopia progression, myopia control techniques, and oculomotor function in human vision.
Resumo:
Purpose: Several studies have suggested accommodative lags may serve as a stimulus for myopic growth, and while a blurred foveal image is believed to the main stimulus for accommodation, spectral composition of the retinal image is also believed to influence accommodative accuracy. Of particular interest is how altering spectral lighting conditions influences accommodation in the presence of soft multifocal contact lenses, which are currently being used off-label for myopia control. Methods: Accommodative responses were assessed using a Grand Seiko WAM-5500 autorefractor for four target distances: 25, 33, 50, and 100cm for 30 young adult subjects (14 myopic, 16 emmetropic; mean refractive errors (±SD, D) -4.22±2.04 and -0.15±0.67 respectively). Measurements were obtained with four different soft contact lenses, Single vision distance (SVD), Single vision near (SVN), Centre-Near (CN) and Centre-Distance (CD) (+1.50 add), and three different lighting conditions: red (peak λ 632nm), blue (peak λ 460nm), and white (peak λ 560nm). Corrections for chromatic differences in refraction were made prior to calculating accommodative errors. Results: The size of accommodative errors was significantly affected by lens design (p<0.001), lighting (p=0.027), and target distance (p=0.009). Mean accommodative errors were significantly larger with the SV lenses compared to the CD and CN designs (p<0.001). Errors were also significantly larger under blue light compared to white (p=0.004) and a significant interaction noted between lens design and lighting (p<0.001). Blue light generally decreased accommodative lags and increased accommodative leads relative to white and red light, the opposite was true of red light (p≤0.001). Lens design also significantly influenced direction of accommodative error (i.e. lag or lead) (p<0.001). Interactions with or between refractive groups were not found to be statistically significant for either the magnitude or direction of accommodative error (p>0.05 for all). Conclusions: Accuracy of accommodation is affected by both lens design and by wavelength of lighting. These accommodative lag data lend some support to recent speculation about the potential therapeutic value of lighting with a spectral bias towards blue during near work for myopia, although such treatment effects are likely to be more subtle under broad compared to the narrow spectrum lighting conditions used here.
Resumo:
Purpose: To investigate the role of corneal endothelial surface enlargement in the chicken myopia model in inducing corneal endothelial changes. Methods: Lid suture was performed on one eye of 1-day-old cockerels. Five chickens were killed at 1 week, and four chickens killed at each of 3 weeks, 6 weeks, and 10 weeks postnatal. The endothelial morphology was obtained by flat mounting the endothelial surface and the subsequent digitisation. Comparisons were undertaken between the control unsutured eye and the lid-sutured eye endothelium, and between the central endothelial areas compared to the peripheral endothelial areas in both the myopic and the normal corneas. Calculation of the contribution to the endothelial change by hypertrophy and mitosis were calculated using Bahn's formula. Results: Total endothelial surface area increased significantly over time in the myopic model compared to control eyes but the mean cell area of endothelial cells remained the same for both the enlarged myopic endothelial surface area and in the normal controls. Sampling from the central and the peripheral corneal endothelial surface also disclosed no difference. The mean cell area did increase steadily with age but was the same for both normal and myopic corneas. Conclusions: It would appear that there are equal contributions from hypertrophy and mitosis in the myopic group and the normal corneal group with a slightly increasing trend towards mitotic activity in the myopic corneal endothelial layer.
Resumo:
Background Corrective eyeglasses are frequently worn by adults, particularly at older ages. Their lenses and frames provide ultraviolet protection. Medial canthal basal cell carcinomas are infrequent (38%), and their relation with the use of corrective glasses was not yet investigated. Objectives To assess the prevalence of corrective eyeglasses use in individuals with medial canthal basal cell carcinoma. Methods Case-control study using two controls matched by age, gender, and ethnicity for each case. Cases were patients with medial canthal basal cell carcinoma, and controls were patients with basal cell carcinoma elsewhere on the face. The prevalence of major risk variables was estimated and adjusted by conditional multiple logistic regression. Results Fifty cases and 100 controls were assessed. The mean patient age was 69.7 years, and 54% of the subjects were females. No difference regarding the eyeglasses use or use duration was found between groups. However, when visual defects were separately evaluated, eyeglasses for myopia correction were independently associated with lower risk of medial canthal basal cell carcinoma development (OR = 0.26; P = 0.03), what can be related to long term local photoprotection. Conclusion The use of eyeglasses for myopia correction is associated with lower prevalence of medial cantal basal cell carcinoma. Risk-reducing mechanisms should be elucidated.
Resumo:
PURPOSE. The purposes of the present study were to assess the effect of a sympathetic inhibitory pharmacologic agent, timolol maleate, on the magnitude of nearwork-induced transient myopia (NITM) and its decay in different refractive groups for an extended near task duration and to determine the proportion of the young adult population manifesting effective sympathetic access under naturalistic closed-loop viewing conditions. METHODS. Ten subjects with emmetropia and 10 with myopia were tested. They read binocularly for 1 hour at a distance of 35 to 40 cm. NITM was calculated as the difference in distance refractive state after task as compared with before task immediately after reading. All subjects received timolol maleate to block the sympathetic nervous system and betaxolol as a control agent in independent test sessions separated by at least 3 days. Forty minutes after drug instillation, the NITM measurement procedure was repeated. RESULTS. Initial NITM magnitude was larger in subjects with myopia than in subjects with emmetropia before and after timolol instillation. Furthermore, NITM magnitude in subjects with sympathetic access was increased after timolol instillation. In contrast, with the control agent betaxolol, there was no increase. NITM decay duration to baseline was increased after timolol instillation in the subjects with myopia only. Only 15% of the subjects (n = 3 subjects with myopia) demonstrated effective and significant access to sympathetic facility. CONCLUSIONS. Subjects with myopia demonstrated an increase in decay duration with timolol, thus suggesting impaired sympathetic inhibition of accommodation. This may be a precursor for myopia progression in some persons.
Resumo:
The principal work reported in this thesis is the examination of autonomic profile of ciliary muscle innervation as a risk factor in myopia development. Deficiency in sympathetic inhibitory control of accommodation has been proposed as a contributory factor in the development of late onset myopia (LOM). Complementary measurements of ocular biometry, oculomotor function and dynamic accommodation response were carried out on the same subject cohort, thus allowing cross-correlation of these factors with. autonomic profile. Subjects were undergraduate and postgraduate students of Aston University. A 2.5 year longitudinal study of refractive error progression in 40 subjects revealed the onset of LOM in 10, initially emmetropic, young adult subjects (age range 18-24 years) undertaking substantial amounts of near work. A controlled, double blind experimental protocol was conducted concurrently to measure post-task open-loop accommodative regression following distance (0 D) or near (3 D above baseline tonic accommodation) closed-loop tasks of short (10 second) or long (3 minute) duration. Closed-loop tasks consisted of observation of a high contrast Maltese cross target; open-loop conditions were imposed by observation of a 0.2 c/deg Difference of Gaussian target. Accommodation responses were recorded continuously at 42 Hz using a modified Shin-Nippon SRW-5000 open-view infra-red optometer. Blockade of the sympathetic branch of accommodative control was achieved by topical instillation of the non-selective b-adrenoceptor antagonist timolol maleate. Betaxolol hydrochloride (non-selective b1-adrenoceptor antagonist) and normal saline were employed as control agents. Retarded open-loop accommodative regression under b2 blockade following the 3 minute near task indicated the presence of sympathetic facility. Sympathetic inhibitory facility in accommodation control was found in similar proportions between LOM and stable emmetropic subjects. A cross-sectional study (N=60) of autonomic profile showed that sympathetic innervation of ciliary muscle is present in similar proportions between emmetropes, early-, and late-onset myopes. Sympathetic facility was identified in 27% of emmetropes, 21% of EOMs and 29% of LOMs.
Resumo:
Objective: To assess the magnitude of nearwork-induced transient myopia (NITM) under binocular viewing conditions separately in each eye of individuals with mild to moderate anisometropia to determine the relationship between NITM and their interocular refractive error. Methods: Forty-three children and young adults with anisometropia [cycloplegic spherical equivalent (SE) difference >1.00 D] were tested (ages 9-28 years). NITM was measured with binocular viewing separately in each eye after binocularly performing a sustained near task (5 D) for 5 min incorporating a cognitive demand using an open-field, infrared autorefractor (Grand-Seiko, WAM-5500). Data were averaged over 10 s bins for 3 min in each eye. Initial NITM, its decay time (DT), and its decay area (DA) were determined. A-scan ultrasound ocular biometry was also performed to determine the axial length of each eye. Results: The more myopic eye exhibited increased initial NITM, DT, and DA as compared to the less myopic eye (0.21 ± 0.16 D vs 0.15 ± 0.13 D, p = 0.026; 108.4 ± 64.3 secs vs 87.0 ± 65.2 secs, p = 0.04; and 17.6 ± 18.7 D*secs vs 12.3 ± 15.7 D*secs, p = 0.064), respectively. The difference in DA and the difference in SE between the more versus less myopic eye were significantly correlated (r = 0.31, p = 0.044). Furthermore, 63% (27/43), 56% (24/43), and 70% (30/43) of the more myopic eyes exhibited increased initial NITM, longer DT, and larger DA, respectively, than found in the less myopic eye. Conclusions: In approximately two-thirds of the anisometropic individuals, the initial NITM and its decay area were significantly increased in the more myopic eye as compared to the less myopic eye. NITM may play an important role in the development of interocular differences in myopia, although a causal relationship is yet to be established. Furthermore, the findings have potentially important implications regarding accommodative control and interocular accommodative responsitivity in anisometropia, in particular for anisomyopia. © 2013 The College of Optometrists.