6 resultados para Monochromators


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Near infrared (NIR) spectroscopy, usually in reflectance mode, has been applied to the analysis of faeces to measure the concentrations of constituents such as total N, fibre, tannins and delta C-13. In addition, an unusual and exciting application of faecal NIR [F.NIR] analyses is to directly predict attributes of the diet of herbivores such as crude protein and fibre contents, proportions of plant species and morphological components, diet digestibility and voluntary DM intake. This is an unusual application of NIR spectroscopy insofar as the spectral measurements are made, not on the material of interest [i.e. the diet), but on a derived material (i.e. faeces). Predictions of diet attributes from faecal spectra clearly depend on there being sufficient NIR spectral information in the diet residues present in faeces to describe the diet, although endogenous components of faeces such as undigested debris of micro-organisms from the rumen and Large intestine and secretions into the gastrointestinal tract wilt also contribute spectral information. Spectra of forage and of faeces derived from the forage are generally similar and the observed differences are principally in the spectral regions associated with constituents of forages known to be of low, or of high, digestibility. Some diet components (for example, ureal which are likely to be entirely digested apparently cannot be predicted from faecal NIR spectra because they cannot contribute to faecal spectra except through modifying the microbial and endogenous components. The errors and robustness of F.NIR calibrations to predict the crude protein concentration and digestibility of the diet of herbivores are generally comparable with those to directly predict the same attributes in forage from NIR spectra of the forage. Some attributes of the animal, such as species, gender, pregnancy status and parasite burden have been successfully discriminated into classes based on their faecal NIR spectra. Such discrimination was likely associated with differences in the diet selected and/or differences in the metabolites excreted in the faeces. NIR spectroscopy of faeces has usually involved scanning dried and ground samples in monochromators in the 400-2500nm or 1100-2500nm ranges. Results satisfactory for the purpose have also been reported for dried and ground faeces scanned using a diode array instrument in the 800-1700nm range and for wet faeces and slurries of excreta scanned with monochromators. Chemometric analysis of faecal spectra has generally used the approaches established for forage analysis. The capacity to predict many attributes of the diet, and some aspects of animal physiology, from NIR spectra of faeces is particularly useful to study the quality and quantity of the diet selected by both domestic and feral grazing herbivores and to enhance production and management of both herbivores and their grazing environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present paper the measured values of vibrational temperature behind strong shock waves are compared with theoretical ones. The histories of vibrational temperature behind strong shock waves in a shock tube were measured using two monochromators. The test gas was pure nitrogen at 100-300Pa, and the speeds of shock waves were 5.0-6.0km/s. The electronic temperature of N-2(+) was also approximately determined from experiment and compared with the experimental vibrational temperature. The results show that the presented calculational method is effective, and the electronic energy of N2+ is excited much faster than its vibrational energy. One Langmuir probe was used to determine the effective time of region 2. The influence of viscosity in the shock tube is also analyzed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thin films of undoped and Sb-doped SnO2 have been prepared by a sol-gel dip-coating technique. For the high doping level (2-3 mol% Sb) n-type degenerate conduction is expected, however, measurements of resistance as a function of temperature show that doped samples exhibit strong electron trapping, with capture levels at 39 and 81 meV. Heating in a vacuum and irradiation with UV monochromatic light (305 nm) improve the electrical characteristics, decreasing the carrier capture at low temperature. This suggests an oxygen related level, which can be eliminated by a photodesorption process. Absorption spectral dependence indicates an indirect bandgap transition with Eg ≅ 3.5 eV. Current-voltage characteristics indicate a thermionic emission mechanism through interfacial states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tissue repair is an integration of dynamic interactive processes that involves soluble mediators, blood components, production of extra-cellular matrix and mesenchymal cells. Many studies involving the use of LLLT shows that the healing process is favored by such therapy. The aim of this work was to evaluate, through histological analysis, the tissue effects of cutaneous wounds submitted to different intensities and a same irradiation dose with lasers in λ670 or λ685nm. Eighteen animals were divided in two experimental groups according to wavelength used (λ670 or λ685nm). Each one of these groups was divided still in three subgroups of three animals each, related to the intensity of applied irradiation (2, 15 or 25mW). Twelve animals acted as untreated controls and were not irradiated. The irradiation was carried out during seven days. The animals were sacrificed eight days after surgery. The specimens were removed, kept in 4% formaldehyde for 24 hours, routinely prepared to wax, stained with H&E and analyzed under light microscopy. The histological characteristics observed, so much in the irradiated animals, as in the control, they are indicative of a substitution repair process, however, the LLLT modulatory positive effect was observed, in the healing process, mainly associate to the use of the shorter wavelength and low power. The results of the present study indicate that LLLT improves cutaneous wound repair and best results are achieved when higher potencies associated to short wavelengths or lower potencies associated to higher wavelengths are used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photoluminescence and photo-excited conductivity data as well as structural analysis are presented for sol-gel SnO2 thin films doped with rare earth ions Eu3+ and Er3+, deposited by sol-gel-dip-coating technique. Photoluminescence spectra are obtained under excitation with various types of monochromatic light sources, such as Kr+, Ar+ and Nd:YAG lasers, besides a Xe lamp plus a selective monochromator with UV grating. The luminescence fine structure is rather different depending on the location of the rare-earth doping, at lattice symmetric sites or segregated at the asymmetric grain boundary layer sites. The decay of photo-excited conductivity also shows different trapping rate depending on the rare-earth concentration. For Er-doped films, above the saturation limit, the evaluated capture energy is higher than for films with concentration below the limit, in good agreement with the different behaviour obtained from luminescence data. For Eu-doped films, the difference in the capture energy is not so evident in these materials with nanoscocopic crystallites, even though the luminescence spectra are rather distinct. It seems that grain boundary scattering plays a major role in Eu-doped SnO2 films. Structural evaluation helps to interpret the electro-optical data. © 2010 IOP Publishing Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La preservación del medio ambiente, el avance en las técnicas para que el impacto de la actividad humana sobre la fauna y flora sea lo menor posible, hacen que se deban monitorizar los diversos indicadores de calidad. El presente estudio viene motivado debido a que actualmente existen sistemas de medida y control en continuo de la calidad de las aguas, al margen de los estudios de laboratorio por toma de muestras, a través de los cuales se obtienen indicadores de calidad. El desarrollo tecnológico en analizadores en continuo para la medida de fósforo, amonio, DBO y otros, hacen que cada vez se consiga un control más exhaustivo de la calidad en tiempo real. Sin embargo, la detección temprana de contaminantes que no deben encontrarse presentes en el agua, hacen que el desarrollo de sensores de detección de estos contaminantes sea de gran utilidad. A este respecto, las técnicas mediante fluorescencia presentan enormes ventajas, ya que no existe contacto directo con la muestra, reduciéndose el desgaste y alargando el tiempo entre mantenimientos, como se ha comprobado en numerosos desarrollos con tecnología láser. Para la producir fluorescencia, tradicionalmente se vienen utilizando en el laboratorio principalmente lámparas de gas y monocromadores. Los nuevos LED de alta potencia en el espectro ultravioleta son una alternativa muy interesante que además puede ser aplicada en los mencionados sistemas de medición en continuo. En este trabajo se realiza un estudio de viabilidad de estos dispositivos como fuentes de excitación para la producción de fluorescencia tomando como contaminantes los hidrocarburos. El funcionamiento en estaciones en continuo hace que se tenga que realizar además ensayos de vida acelerados, así como estudios de modos de trabajo. Al respecto de la fluorescencia producida, se estudia la influencia de factores que pueden afectar a las medidas, tales como la temperatura. El estudio del espectro y su análisis para la identificación del contaminante es otro de los puntos desarrollados en este trabajo. Por último, y dado que la monitorización se realiza en modo continuo, es necesario un sistema de comunicaciones compacto y fiable: en este apartado se analizan los metamateriales como solución tecnológica, ya que se adapta perfectamente a la filosofía de estas estaciones de medición. ABSTRACT Currently the monitoring of quality indicators is a need to preserve the environment and minimize the impact of human activity on the fauna and flora. Currently there are measuring systems and continuous monitoring of water quality, regardless of sampling laboratory studies, through which quality indicators are obtained. Technological development in continuous analyzers for the measurement of phosphorus, ammonia, BOD and others increasingly make a more comprehensive real-time quality control is achieved. However, early detection of contaminants that should not be present in the water, make the development of sensors for detecting these contaminants is very useful. In this regard, fluorescence techniques have huge advantages, since there is no direct contact with the sample, reducing wear and extending the time between maintenance, as has been demonstrated in numerous developments in laser technology. To produce fluoresce, traditionally are being used mainly gas lamps and monochromators at the laboratory. The new high-power LEDs in the ultraviolet spectrum are a very interesting alternative that can also be applied in the above continuous measurement systems. In this paper a viability study of these devices as excitation sources to produce fluorescence using hydrocarbon as contaminants is performed. The stations in continuous operation makes it necessary to also perform accelerated life tests and studies operating modes. In regard to the fluorescence produced, the influence of factors that may affect the measurements, such as temperature is studied. The study of the spectrum and analysis to identify the contaminant is another of the points developed in this work. Finally, since the monitoring is carried out in continuous mode, a compact and reliable communication is necessary: in this section metamaterials as a technological solution is analyzed since it fits perfectly with the philosophy of these measuring stations.