920 resultados para Monitoring Systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The modern structural diagnosis process is rely on vibration characteristics to assess safer serviceability level of the structure. This paper examines the potential of change in flexibility method to use in damage detection process and two main practical constraints associated with it. The first constraint addressed in this paper is reduction in number of data acquisition points due to limited number of sensors. Results conclude that accuracy of the change in flexibility method is influenced by the number of data acquisition points/sensor locations in real structures. Secondly, the effect of higher modes on damage detection process has been studied. This addresses the difficulty of extracting higher order modal data with available sensors. Four damage indices have been presented to identify their potential of damage detection with respect to different locations and severity of damage. A simply supported beam with two degrees of freedom at each node is considered only for a single damage cases throughout the paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Automatic recording instruments provide the ideal means of recording the responses of rivers, lakes and reservoirs to short-term changes in the weather. As part of the project ‘Using Automatic Monitoring and Dynamic Modelling for the Active Management of Lakes and Reservoirs', a family of three automatic monitoring stations were designed by engineers at the Centre for Ecology and Hydrology in Windermere to monitor such responses. In this article, the authors describe this instrument network in some detail and present case studies that illustrate the value of high resolution automatic monitoring in both catchment and reservoir applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A wearable silver nano particle inkjet printed antenna suitable for wireless biomedical sensing is presented. The performance is evaluated on a synthetic variable layered phantom test-bed, representative of human tissue for operation in the 868/915 MHz, and 2400 MHz industrial, scientific and medical frequency bands. Antenna radiation efficiency measurements on the phantom were compared with antennas prototyped with copper. Total radiation efficiencies up to ???6.5 dB are reported, with less than 0.5 dB difference in performance between copper and silver nano particle variants, showing promising application for low-cost disposable wireless sensing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis to obtain the Master Degree in Electronics and Telecommunications Engineering

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mirids (Sahlbergella singularis and Distantiella theobroma) are the most important insect pests affecting cocoa production across West Africa. Understanding the population dynamics of mirids is key to their management, however, the current recommended hand-height assessment method is labour intensive. The objective of the study was to compare recently developed mirid sex pheromone trapping and visual hand-height assessment methods as monitoring tools on cocoa farms and to consider implications for a decision support system. Ten farms from the Eastern and Ashanti regions of Ghana were used for the study. Mirid numbers and damage were assessed fortnightly on twenty trees per farm, using both methods, from January 2012 to April 2013. The mirid population increased rapidly in June, reached a peak in September and began to decline in October. There was a significant linear relationship between numbers of mirids sampled to hand-height and mirid damage. High numbers of male mirids were recorded in pheromone traps between January and April 2012 after which there was a gradual decline. There was a significant inverse relationship between numbers of trapped adult mirids and mirids sampled to hand-height (predominantly nymphs). Higher temperatures and lower relative humidities in the first half of the year were associated with fewer mirids at hand-height but larger numbers of adult males were caught in pheromone traps. The study showed that relying solely on one method is not sufficient to provide accurate information on mirid population dynamics and a combination of the two methods is necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated cardiac output (CO) using three new methods – the auto-calibrated FloTrac–Vigileo (COed), the non-calibrated Modelflow (COmf ) pulse contour method and the ultra-sound HemoSonic system (COhs) – with thermodilution (COtd) as the reference. In 13 postoperative cardiac surgical patients, 104 paired CO values were assessed before, during and after four interventions: (i) an increase of tidal volume by 50%; (ii) a 10 cm H2O increase in positive end-expiratory pressure; (iii) passive leg raising and (iv) head up position. With the pooled data the difference (bias (2SD)) between COed and COtd, COmf and COtd and COhs and COtd was 0.33 (0.90), 0.30 (0.69) and −0.41 (1.11) l.min−1, respectively. Thus, Modelflow had the lowest mean squared error, suggesting that it had the best performance. COed significantly overestimates changes in cardiac output while COmf and COhs values are not significantly different from those of COtd. Directional changes in cardiac output by thermodilution were detected with a high score by all three methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development and application of a novel combination of electrochemical techniques and computerized field-based battery-operated instrumentation is investigated. Low-power complementary metal oxide semiconductor technology has been utilized for the development of the field data acquisition systems and the instrumental performance of the complete analytical system is critically evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigates the growth and metabolite production of microorganisms causing spoilage of Atlantic cod (Gadus morhua) fillets packaged under air and modified atmosphere (60 % CO2, 40 % O2). Samples were provided by two different retailers (A and B). Storage of packaged fillets occurred at 4 °C and 8 °C. Microbiological quality and metabolite production of cod fillets stored in MAP 4 °C, MAP 8 °C and air were monitored during 13 days, 7 days and 3 days of storage, respectively. Volatile compounds concentration in the headspace were quantified by Selective ion flow tube mass spectrometry and a correlation with microbiological spoilage was studied. The onset of volatile compounds detection was observed to be mostly around 7 log cfu/g of total psychrotrophic count. Trimethylamine and dimethyl sulfide were found to be the dominant volatiles in all of the tested storage conditions, nevertheless there was no close correlation between concentrations of each main VOC and percentages of rejection based on sensory evaluation. According to results it was concluded that they cannot be considered as only indicators of the quality of cod fillets stored in modified atmosphere and air.  

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the multiple case-study was to determine how hospital subsystems (such as physician monitoring and credentialing; quality assurance; risk management; and peer review) were supporting the monitoring of physicians? Three large metropolitan hospitals in Texas were studied and designated as hospitals #1, #2, and #3. Realizing that hospital subsystems are a unique entity and part of a larger system, conclusions were made on the premises of a quality control system, in relation to the tools of government (particularly the Health Care Quality Improvement Act (HCQIA)), and in relation to itself as a tool of a hospital.^ Three major analytical assessments were performed. First, the subsystems were analyzed as to their "completeness"; secondly, the subsystems were analyzed for "performance"; and thirdly, the subsystems were analyzed in reference to the interaction of completeness and performance.^ The physician credentialing and monitoring and the peer review subsystems as quality control systems were most complete, efficient, and effective in hospitals #1 and #3. The HCQIA did not seem to be an influencing factor in the completeness of the subsystem in hospital #1. The quality assurance and risk management subsystem in hospital #2 was not representative of completeness and performance and the HCQIA was not an influencing factor in the completeness of the Q.A. or R.M. systems in any hospital. The efficiency (computerization) of the physician credentialing, quality assurance and peer review subsystems in hospitals #1 and #3 seemed to contribute to their effectiveness (system-wide effect).^ The results indicated that the more complete, effective, and efficient subsystems were characterized by (1) all defined activities being met, (2) the HCQIA being an influencing factor, (3) a decentralized administrative structure, (4) computerization an important element, and (5) staff was sophisticated in subsystem operations. However, other variables were identified which deserve further research as to their effect on completeness and performance of subsystems. They include (1) medical staff affiliations, (2) system funding levels, (3) the system's administrative structure, and (4) the physician staff "cultural" characteristics. Perhaps by understanding other influencing factors, health care administrators may plan subsystems that will be compatible with legislative requirements and administrative objectives. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"March 1990."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prepared under contract no. HSM 110-70-406.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.