934 resultados para Molecular-weight Compounds


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aerosol samples were collected in Zurich, Switzerland, at an urban background site and were analyzed with size exclusion chromatography (SEC) and laser/desorption ionization mass spectrometry (LDI-MS) for water-soluble organic compounds with high molecular weight. Daily samples were collected during two campaigns in winter and summer, for 1 month each. The concentration of high-molecular-weight compounds (humic-like substances (HULIS)) was between 0.4 and 4 μg/m3 in winter and summer. The most intense signals in the LDI-MS mass spectra were measured between m/z150 and 500, comparing well with the mode of the two main high mass peaks determined with SEC corresponding to masses between 200 and 600 Da. For the maximum molecular weight, however, different results were obtained by the two techniques: whereas a maximum molecular weight between 1300 and 3300 Da was found with SEC, hardly any peaks above m/z700 were measured with LDI-MS. During summer the maximum molecular weight of HULIS (determined with SEC) correlates positively with several parameters such as ozone and increased temperature indicative of enhanced atmospheric photo-oxidation. The HULIS concentration also correlates positively with the oxalic acid concentration in the particles. This suggests that HULIS are generated by secondary processes in summer. The lack of such correlations during winter suggests that other sources and processes might be important during colder seasons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mushrooms have the ability to promote apoptosis in tumor cell lines, but the mechanism of action is not quite well understood. Inhibition of the interaction between Bcl-2 and pro-apoptotic proteins could be an important step that leads to apoptosis. Therefore, the discovery of compounds with the ability to inhibit Bcl-2 is an ongoing research topic in drug discovery. In this study, we started by analyzing Bcl-2 experimental structures that are currently available in Protein Data Bank database. After analysis of the more relevant Bcl-2 structures, 4 were finally selected. An analysis of the best docking methodology was then performed using a cross-docking and re-docking approach while testing 2 docking softwares: AutoDock 4 and AutoDock Vina. Autodock4 provided the best docking results and was selected to perform a virtual screening study applied to a dataset of 40 Low Molecular Weight (LMW) compounds present in mushrooms, using the selected Bcl-2 structures as target. Results suggest that steroid are the more promising family, among the analyzed compounds, and may have the ability to interact with Bcl-2 and this way promoting tumor apoptosis. The steroids that presented lowest estimated binding energy (ΔG) were: Ganodermanondiol, Cerevisterol, Ganoderic Acid X and Lucidenic Lactone; with estimated ΔG values between -8,45 and -8,23 Kcal/mol. A detailed analysis of the docked conformation of these 4 top ranked LMW compounds was also performed and illustrates a plausible interaction between the 4 top raked steroids and Bcl-2, thus substantiating the accuracy of the predicted docked poses. Therefore, tumoral apoptosis promoted by mushroom might be related to Bcl-2 inhibition mediated by steroid family of compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increased awareness and evolved consumer habits have set more demanding standards for the quality and safety control of food products. The production of foodstuffs which fulfill these standards can be hampered by different low-molecular weight contaminants. Such compounds can consist of, for example residues of antibiotics in animal use or mycotoxins. The extremely small size of the compounds has hindered the development of analytical methods suitable for routine use, and the methods currently in use require expensive instrumentation and qualified personnel to operate them. There is a need for new, cost-efficient and simple assay concepts which can be used for field testing and are capable of processing large sample quantities rapidly. Immunoassays have been considered as the golden standard for such rapid on-site screening methods. The introduction of directed antibody engineering and in vitro display technologies has facilitated the development of novel antibody based methods for the detection of low-molecular weight food contaminants. The primary aim of this study was to generate and engineer antibodies against low-molecular weight compounds found in various foodstuffs. The three antigen groups selected as targets of antibody development cause food safety and quality defects in wide range of products: 1) fluoroquinolones: a family of synthetic broad-spectrum antibacterial drugs used to treat wide range of human and animal infections, 2) deoxynivalenol: type B trichothecene mycotoxin, a widely recognized problem for crops and animal feeds globally, and 3) skatole, or 3-methyindole is one of the two compounds responsible for boar taint, found in the meat of monogastric animals. This study describes the generation and engineering of antibodies with versatile binding properties against low-molecular weight food contaminants, and the consecutive development of immunoassays for the detection of the respective compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation presented to obtain a Ph.D. Degree in Chemical Physics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the PAH class of compounds, high molecular weight PAH are now considered as relevant cancer inducers, but not all of them have the same biological activity. However, their analysis is difficult, mainly due to the presence of numerous isomers and due to their low volatility. Retention indices (Ri) for 13 dibenzopyrenes and homologues were determined by high-resolution capillary gas chromatography (GC) with four different stationary phases: a 5% phenyl-substituted methylpolysiloxane column (DB-5 ms), a 35% phenyl-substituted methylpolysiloxane column (BPX-35), a 50% phenyl-substituted methylpolysiloxane column (BPX-50), and a 35% trifluoropropylmethyl polysiloxane stationary phase (Rtx-200). Correlations for retention on each phase were investigated by using 8 independent molecular descriptors. Ri has been shown to be linearly correlated to PAH volume, polarisability alpha, Hückel-pi energy on the four examined columns. Ionisation potential Ip is a fourth variable which improves the regression model for DB-5ms, BPX-35, and BPX-50 column. Correlation coefficients ranging from r2 = 0.935 to r2 = 0.952 are then observed. Application of these indices to the identification and quantification of PAH with MW 302 in certified diesel particulate matter SRM 1650a is presented and discussed. [Authors]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rhizoremediation is a bioremediation technique whereby enhanced microbial degradation of organic contaminants occurs within the plant root zone (rhizosphere). It is considered an effective and affordable ‘green technology’ for remediating soils contaminated with petroleum hydrocarbons (PHCs). This paper critically reviews the potential role of root exuded compounds in rhizoremediation, with emphasis on commonly exuded low molecular weight aliphatic organic acid anions (carboxylates). The extent to which remediation is achieved shows wide disparity among plant species. Therefore, plant selection is crucial for the advancement and widespread adoption of this technology. Root exudation is speculated to be one of the predominant factors leading to microbial changes in the rhizosphere and thus the potential driver behind enhanced petroleum biodegradation. Carboxylates can form a significant component of the root exudate mixture and are hypothesised to enhance petroleum biodegradation by: i) providing an easily degradable energy source; ii) increasing phosphorus supply; and/or iii) enhancing the contaminant bioavailability. These differing hypotheses, which are not mutually exclusive, require further investigation to progress our understanding of plant–microbe interactions with the aim to improve plant species selection and the efficacy of rhizoremediation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on the development and optimization of a modified Quick, Easy, Cheap Effective, Rugged and Safe (QuEChERS) based extraction technique coupled with a clean-up dispersive-solid phase extraction (dSPE) as a new, reliable and powerful strategy to enhance the extraction efficiency of free low molecular-weight polyphenols in selected species of dietary vegetables. The process involves two simple steps. First, the homogenized samples are extracted and partitioned using an organic solvent and salt solution. Then, the supernatant is further extracted and cleaned using a dSPE technique. Final clear extracts of vegetables were concentrated under vacuum to near dryness and taken up into initial mobile phase (0.1% formic acid and 20% methanol). The separation and quantification of free low molecular weight polyphenols from the vegetable extracts was achieved by ultrahigh pressure liquid chromatography (UHPLC) equipped with a phodiode array (PDA) detection system and a Trifunctional High Strength Silica capillary analytical column (HSS T3), specially designed for polar compounds. The performance of the method was assessed by studying the selectivity, linear dynamic range, the limit of detection (LOD) and limit of quantification (LOQ), precision, trueness, and matrix effects. The validation parameters of the method showed satisfactory figures of merit. Good linearity (View the MathML sourceRvalues2>0.954; (+)-catechin in carrot samples) was achieved at the studied concentration range. Reproducibility was better than 3%. Consistent recoveries of polyphenols ranging from 78.4 to 99.9% were observed when all target vegetable samples were spiked at two concentration levels, with relative standard deviations (RSDs, n = 5) lower than 2.9%. The LODs and the LOQs ranged from 0.005 μg mL−1 (trans-resveratrol, carrot) to 0.62 μg mL−1 (syringic acid, garlic) and from 0.016 μg mL−1 (trans-resveratrol, carrot) to 0.87 μg mL−1 ((+)-catechin, carrot) depending on the compound. The method was applied for studying the occurrence of free low molecular weight polyphenols in eight selected dietary vegetables (broccoli, tomato, carrot, garlic, onion, red pepper, green pepper and beetroot), providing a valuable and promising tool for food quality evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high molecular weight poly(ethylene oxide)/layered vanadyl phosphate di-hydrate intercalation compound was synthesized via the surfactant-assisted approach. Results confirmed that surfactant molecules were replaced with the polymer, while the lamellar structure of the matrix was retained, and that the material presents high specific surface area. In addition, intercalation produced a more thermally stable polymer as evidenced by thermal analysis. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

C2-C8 hydrocarbon concentrations (about 35 compounds identified, including saturated, aromatic, and olefinic compounds) from 38 shipboard sealed, deep-frozen core samples of Deep Sea Drilling Project Sites 585 (East Mariana Basin) and 586 (Ontong-Java Plateau) were determined by a gas stripping-thermovaporization method. Total concentrations, which represent the hydrocarbons dissolved in the pore water and adsorbed on the mineral surfaces of the sediment, vary from 20 to 630 ng/g of rock at Site 585 (sub-bottom depth range 332-868 m). Likewise, organic-carbon normalized yields range from 3*10**4 to 9*10**5 ng/g Corg, indicating that the organic matter is still in the initial, diagenetic evolutionary stage. The highest value (based on both rock weight and organic carbon) is measured in an extremely organic-carbon-poor sample of Lithologic Subunit VB (Core 585-30). In this unit (504-550 m) several samples with elevated organic-carbon contents and favorable kerogen quality including two thin "black-shale" layers deposited at the Cenomanian/Turonian boundary (not sampled for this study) were encountered. We conclude from a detailed comparison of light hydrocarbon compositions that the Core 585-30 sample is enriched in hydrocarbons of the C2-C8 molecular range, particularly in gas compounds, which probably migrated from nearby black-shale source layers. C2-C8 hydrocarbon yields in Site 586 samples (sub-bottom depth range 27-298 m) did not exceed 118 ng/g of dry sediment weight (average 56 ng/g), indicating the immaturity of these samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of C2-C8 hydrocarbons (including saturated, aromatic, and olefinic compounds) from deep-frozen core samples taken during DSDP Leg 75 (Holes 530A and 532) were analyzed by a combined hydrogen-stripping/thermovaporization method. Concentrations representing both hydrocarbons dissolved in the pore water and adsorbed on the mineral surfaces vary in Hole 530A from about 10 to 15,000 ng/g of dry sediment weight depending on the lithology (organic-carbon-lean calcareous oozes versus "black shales"). Likewise, the organic-carbon-normalized C2-C8 hydrocarbon concentrations vary from 3,500 to 93,100 ng/g Corg, reflecting drastic differences in the hydrogen contents and hence the hydrocarbon potential of the kerogens. The highest concentrations measured of nearly 10**5 ng/g Corg are about two orders of magnitude below those usually encountered in Type-II kerogen-bearing source beds in the main phase of petroleum generation. Therefore, it was concluded that Hole 530A sediments, even at 1100 m depth, are in an early stage of evolution. The corresponding data from Hole 532 indicated lower amounts (3,000-9,000 ng/g Corg), which is in accordance with the shallow burial depth and immaturity of these Pliocene/late Miocene sediments. Significant changes in the light hydrocarbon composition with depth were attributed either to changes in kerogen type or to maturity related effects. Redistribution pheonomena, possibly the result of diffusion, were recognized only sporadically in Hole 530A, where several organic-carbon lean samples were enriched by migrated gaseous hydrocarbons. The core samples from Hole 530A were found to be severely contaminated by large quantities of acetone, which is routinely used as a solvent during sampling procedures on board Glomar Challenger.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heparin has been used as a clinical anticoagulant for more than 50 years, making it one of the most effective pharmacological agents known. Much of heparin's activity can be traced to its ability to bind antithrombin III (AT-III). Low molecular weight heparin (LMWH), derived from heparin by its controlled breakdown, maintains much of the antithrombotic activity of heparin without many of the serious side effects. The clinical significance of LMWH has highlighted the need to understand and develop chemical or enzymatic means to generate it. The primary enzymatic tools used for the production of LMWH are the heparinases from Flavobacterium heparinum, specifically heparinases I and II. Using pentasaccharide and hexasaccharide model compounds, we show that heparinases I and II, but not heparinase III, cleave the AT-III binding site, leaving only a partially intact site. Furthermore, we show herein that glucosamine 3-O sulfation at the reducing end of a glycosidic linkage imparts resistance to heparinase I, II, and III cleavage. Finally, we examine the biological and pharmacological consequences of a heparin oligosaccharide that contains only a partial AT-III binding site. We show that such an oligosaccharide lacks some of the functional attributes of heparin- and heparan sulfate-like glycosaminoglycans containing an intact AT-III site.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of core samples taken during Cruise 79 of Glomar Challenger, drilling offshore Morocco (Mazagan Plateau), is analyzed for their low-molecular-weight hydrocarbon contents. Fifty-four samples from DSDP Holes 544A, 545, 547A, and 547B, deep frozen on board immediately after recovery, are studied by a hydrogen-stripping/thermovaporization technique combined with capillary gas chromatography. Thirty-eight compounds in the C2-C8 molecular range, including saturated, olefinic, and aromatic hydrocarbons, are identified. Because of large differences in organic carbon contents, the total C2-C8 hydrocarbon concentrations vary from about 20 to 1500 ng/g dry sediment weight in the whole sample series. Organic-carbon normalized values are about 3.2 x 10**4 ng/g Corg for Lithologic Subunits IIIA and IIIB at Site 545 (Cenomanian to Aptian) and 1.0 x 10**5 ng/g Corg for Unit V at Site 547 (Cenomanian to Albian) reflecting the slightly more advanced maturity stage at the latter site. Values exceeding 10**5 ng/g Corg (Site 545) and 2 x 10**5 ng/g Corg (Site 547) are associated with samples that are very lean in organic carbon and are generally rich in carbonate. These samples are enriched by small amounts of gaseous hydrocarbons. A detailed study of individual hydrocarbon concentrations, plotted against depth, reveal additional indications for migration phenomena. At Site 547, for instance, the most mobile hydrocarbons studied (e.g., ethane) appear to migrate by diffusion or a related process from more than 700 m depth toward the surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

C2-C8 hydrocarbons (36 compounds identified) from 56 shipboard sealed, deep-frozen core samples of DSDP Leg 71, Site 511, Falkland Plateau, South Atlantic, were analyzed by a combined hydrogen stripping-thermovaporization method. Concentrations, which represent hydrocarbons dissolved in the pore water and adsorbed to the mineral surfaces of the sediment, vary from 24 ng/g of dry weight sediment in Lithologic Unit 4 to 17,400 ng/g in Lithologic Unit 6 ("black shale" unit). Likewise, the organic carbon normalized C2-C8 hydrocarbon concentrations range from 104 to 3.5 x 105 ng/g Corg. The latter value is more than one order of magnitude lower than expected for petroleum source beds in the main phase of oil generation. The low maturity at 600 meters depth is further supported by light hydrocarbon concentration ratios. The change of the kerogen type from Lithologic Unit 5 (Type III) to 6 (Type II) is evidenced by changes in the C6 and C7 hydrocarbon composition. Redistribution phenomena are observed close to the Tertiary-Cretaceous unconformity and at the contact between the "black shale" unit and the overlying Cretaceous chalks and claystones. Otherwise, the low molecular weight hydrocarbons in Hole 511 are formed in situ and remain at their place of formation. The core samples turned out to be contaminated by large quantities of acetone, which is routinely used as a solvent during sampling procedures onboard Glomar Challenger.