705 resultados para Mobile substations


Relevância:

60.00% 60.00%

Publicador:

Resumo:

One of the most important decisions to turn a substation automatic and no attended it relates to the communication media between this substation and Operation Center. Generally energy companies uses radio or optic fiber, depending of distances and infrastructure of each situation. This rule applies to common substations. Mobile substations are a particular case, therefore they are conceived for use at provisional situations, emergencies, preventive or corrective maintenance. Thus the telecommunication solution used at common substations are not applied so easily to mobile substations, due absence of infrastructure (media) or difficulty to insert the mobile substation data in existing automation network not long. The ideal media must supply covering in a great geographic area to satisfy presented requirements. The implantation costs of this big infrastructure are expensive, however a existing operator may be used. Two services that fulfill that requirements are satellite and cellular telephony. This work presents a solution for automation of mobile substations through satellite. It was successfully implanted at a brazilian electric energy concessionaire named COSERN. The operation became transparent to operators. Other gotten benefits had been operational security, quality in the supply of electric energy and costs reduction. The project presented is a new solution, designed to substations and general applications where few data should be transmitted, but there is difficulties in relation to the media. Despite the satellite having been used, the same resulted can be gotten using celullar telephony, through Short Messages or packet networks as GPRS or EDGE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work has aimed to determine the 16 US EPA priority PAH atmospheric particulate matter levels present in three sites around Salvador, Bahia: (i) Lapa bus station, strongly impacted by heavy-duty diesel vehicles; (ii) Aratu harbor, impacted by an intense movement of goods, and (iii) Bananeira village on Maré Island, a non vehicle-influenced site with activities such as handcraft work and fisheries. Results indicated that BbF (0.130-6.85 ng m-3) is the PAH with highest concentration in samples from Aratu harbor and Bananeira and CRY (0.075-6.85 ng m-3) presented higher concentrations at Lapa station. PAH sources from studied sites were mainly of anthropogenic origin such as gasoline-fueled light-duty vehicles and diesel-fueled heavy-duty vehicles, discharges in the port, diesel burning from ships, dust ressuspension, indoor soot from cooking, and coal and wood combustion for energy production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, nonlinear dynamic equations of a wheeled mobile robot are described in the state-space form where the parameters are part of the state (angular velocities of the wheels). This representation, known as quasi-linear parameter varying, is useful for control designs based on nonlinear H(infinity) approaches. Two nonlinear H(infinity) controllers that guarantee induced L(2)-norm, between input (disturbances) and output signals, bounded by an attenuation level gamma, are used to control a wheeled mobile robot. These controllers are solved via linear matrix inequalities and algebraic Riccati equation. Experimental results are presented, with a comparative study among these robust control strategies and the standard computed torque, plus proportional-derivative, controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many Archean cratons are surrounded by Proterozoic mobile belts that have experienced episodes of tectonic re-activation over their lifetimes. This suggests that mobile belt lithosphere may be associated with long lived, inherited weakness. It is proposed that the proximity of this weakness can increase the longevity of deep Archean lithosphere by buffering Archean cratons from mantle derived stresses. The physical plausibility of this idea is explored through numerical simulations of mantle convection that include continents and allow for material rheologies that model the combined brittle and ductile behavior of the lithosphere. Within the simulations, the longevity of deep cratonic lithosphere does increase if it is buffered by mobile belts that can fail at relatively low stress levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mobile Lipids detected using H-1-NMR in stimulated lymphocytes were correlated with cell cycle phase, expression of the interleukin-2 receptor alpha and proliferation to assess the activation status of the lymphocytes. Mobile lipid levels, IL-2R alpha expression and proliferation increased after treatment with PMA and ionomycin. PMA or ionomycin stimulation alone induced increased IL-2R alpha expressiom but not proliferation, PMA- but not ionomycin-stimulation generated mobile lipid, Treatment with anti-CD3 antibody did not increase IL-2R alpha expression or proliferation but did generate increased amounts of mobile lipid, The cell cycle status of thymocytes treated with anti-CD3, PMA or ionomycin alone indicated an. accumulation of the cells in the G(1) phase of the cell cycle, The generation of mobile lipid was abrogated in anti-CD3 antibody-stimulated thymic lymphocytes but not in splenic lymphocytes, using a phosphatidylcholine-specific phospholipase C (PC-PLC) inhibitor which blocked cells in the G(1)/S phase of the cell cycle, This suggests that the H-1-NMR-detectable mobile Lipid may be generated in anti-CD3 antibody-stimulated thymic lymphocytes by the action of PC-PLC activity via the catabolism of PC, in the absence of classical signs of activation. (C) 1997 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cervical cancer is a serious public health problem in women in developing countries because of absence or ineffectiveness of screening programs. Several biases to access medical care and inequity of public health system in a continental country like Brazil limit the implementation of adequate programs to appropriately prevent the cervical cancer. Therefore, the aim of this study was to evaluate the results of applying the mobile unit (MU) for cervical cancer screening. From May 2003 to May 2004, a cervical cancer screening was offered to women aged 20-69 years, residing in 19 municipal districts of the Barretos county region, in Sao Paulo. Out of the 9,560 examination available, 2,964 (31%) women underwent screening. The medium distance traveled by the MU was 45 km. The medium time spent by women in the MU for completion of the questionnaire and doing the exam was 20 minutes. It was observed that 17.0% of women screened had never had the test or had not had it repeated within the last 3 years. The negative response was more common among women aged 20 to 29 years and 60 to 69 years and among women with less schooling and lower socio-economic income (P < 0.05). MU can significantly overcome the chronic deficiency of public health system accessibility offering opportunity to these women to participate in screening programs. Diagn. Cytopathol. 2010;38:727-730. (C) 2009 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To evaluate the initial results of a prostate cancer screening program using mobile units in Brazil. METHODS Since 2004, we have conducted a program of prostate cancer screening using mobile units across 231 municipalities from 6 Brazilian states. RESULTS A total of 17 571 men were evaluated by clinical history, digital rectal examination (DRE), and serum free and total prostate-specific antigen (PSA) levels. The recommendations for biopsy were a PSA level of >= 4.0 ng/mL, DRE findings suspicious for cancer, or a PSA level of 2.5-4.0 ng/mL with a percent-free PSA level <15%. The biopsy protocol included 12 biopsy cores from the peripheral zone, 2 from the transition zone, and additional sampling of suspicious areas. The cumulative cancer detection rate was 3.7%. The main indication for biopsy was a PSA level of >= 4.0 ng/mL (51.2%), with a positive predictive value (PPV) of 44.1%. Another 19.7% of biopsied men had suspicious DRE findings with a normal PSA level (PPV 23.5%). A percent-free PSA level of <15% in men with a PSA level of 2.5-4.0 ng/mL and normal DRE findings yielded a PPV of 31.1%. The PPV was greater (70.9%) for the 7.1% of men with both suspicious DRE findings and a PSA level of >4.0 ng/mL. Most cancers were Stage T1-T2 (93.4%), and the percentage of Gleason score of >= 7 was 32.5%. The proportion of insignificant cancers according to Epstein`s criteria was 13.5%. CONCLUSIONS A mobile prostate cancer screening unit enabled an underserved population to gain access to specialized care through the public healthcare system. The cancer detection rate in this population was similar to those from international studies. UROLOGY 76: 1052-1057, 2010. (C) 2010 Published by Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador: