79 resultados para Microsurgery


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Near-infrared laser-based microsurgery is promising for noninvasive cancer treatment. To make it a safe technique, a therapeutic process should be controllable and energy efficient, which requires the cancer cells to be identifiable and observable. In this work, for the first time we use a miniaturized nonlinear optical endomicroscope to achieve microtreatment of cancer cells labeled with gold nanorods. Due to the high two-photon-excited photoluminescence of gold nanorods, HeLa cells inside a tissue phantom up to 250 μm deep can be imaged by the nonlinear optical endomicroscope. This facilitates microsurgery of selected cancer cells by inducing instant damage through the necrosis process, or by stopping cell proliferation through the apoptosis process. The results indicate that a combination of nonlinear endomicroscopy with gold nanoparticles is potentially viable for minimally invasive cancer treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motion analysis of a parallel robot assisted minimally invasive surgery/microsurgery system (PRAMiSS) and the control structures enabling it to achieve milli/micromanipulations under the constraint of moving through a fixed penetration point or so-called remote centre-of-motion (RCM) are presented in this article. Two control algorithms are proposed suitable for minimally invasive surgery (MIS) with submillimeter accuracy and for minimally invasive micro-surgery (MIMS) with submicrometer accuracy. The RCM constraint is performed without having any mechanical constraint. Control algorithms also apply orientation constraint preventing the tip to orient relative to the soft tissues due to the robot movements. Experiments were conducted to verify accuracy and effectiveness of the proposed control algorithms for MIS and MIMS operations. The experimental results demonstrate accuracy and performance of the proposed position control algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postoperative pelvic abscesses in patients submitted to colorectal surgery are challenging. The surgical approach may be too risky, and image-guided drainage often is difficult due to the complex anatomy of the pelvis. This article describes novel access for drainage of a pelvic collection using a minimally invasive natural orifice approach. A 37 year-old man presented with sepsis due to a pelvic abscess during the second postoperative week after a Hartmann procedure due to perforated rectal cancer. Percutaneous drainage was determined by computed tomography to be unsuccessful, and another operation was considered to be hazardous. Because the pelvic fluid was very close to the rectal stump, transrectal drainage was planned. The rectal stump was opened using transanal endoscopic microsurgery (TEM) instruments. The endoscope was advanced through the TEM working channel and the rectal stump opening, accessing the abdominal cavity and pelvic collection. The pelvic collection was endoscopically drained and the local cavity washed with saline through the scope channel. A Foley catheter was placed in the rectal stump. The patient's recovery after the procedure was successful, without the need for further intervention. Transrectal endoscopic drainage may be an option for selected cases of pelvic fluid collection in patients submitted to Hartmann's procedure. The technique allows not only fluid drainage but also visualization of the local cavity, cleavage of multiloculated abscesses, and saline irrigation if necessary. The use of TEM instrumentation allows safe access to the peritoneal cavity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumors involving bone and soft tissues are extremely challenging situations. With the recent advances of multi-modal treatment, not only the type of surgery has moved from amputation to limb-sparing procedures, but also the survivorship has improved considerably and reconstructive techniques have the goal to allow a considerably higher quality of life. In bone reconstruction, tissue engineering strategies are the main area of research. Re-vascularization and re-vitalisation of a massive allograft would considerably improve the outcome of biological reconstructions. Using a rabbit animal model, in this study we showed that, by implanting a vascular pedicle inside a weight bearing massive cortical allograft, the bone regeneration inside the allograft was higher compared to the non-vascularized implants, given the patency of the vascular pedicle. Improvement in the animal model and the addition of Stem Cells and Growth factors will allow a further improvement in the results. In soft tissue tumors, free and pedicled flaps have been proven to be of great help as reconstruction strategies. In this study we analyzed the functional and overall outcome of 14 patients who received a re-innervated vascularized flap. We have demonstrated that the use of the innovative technique of motor re-innervated muscular flaps is effective when the resection involves important functional compartments of the upper or lower limb, with no increase of post-operative complications. Although there was no direct comparison between this type of reconstruction and the standard non-innervated reconstruction, we underlined the remarkable high overall functional scores and patient satisfaction following this procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concerns of rising healthcare costs and the ever increasing desire to improve surgical outcome have motivated the development of a new robotic assisted surgical procedure for the implantation of artificial hearing devices (AHDs). This paper describes our efforts to enable minimally invasive, cost effective surgery for the implantation of AHDs. We approach this problem with a fundamental goal to reduce errors from every component of the surgical workflow from imaging and trajectory planning to patient tracking and robot development. These efforts were successful in reducing overall system error to a previously unattained level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The delicate anatomy of the ear require surgeons to use great care when operating on its internal structures. One example for such an intervention is the stapedectomy, where a small crook shaped piston is placed in the oval window of the cochlea and connected to the incus through crimping thus bypassing the diseased stapes. Performing the crimp process with the correct force is necessary since loose crimps poorly transmit sound whereas tight crimps will eventually result in necrosis of the incus. Clinically, demand is high to reproducibly conduct the crimp process through a precise force measurement. For this reason, we have developed a fiber Bragg grating (FBG) integrated microforceps for use in such interventions. This device was calibrated, and tested in cadaver preparations. With this instrument we were able to measure for the first time forces involved in crimping a stapes prosthesis to the incus. We also discuss a method of attaching and actuating such forceps in conjunction with a robot currently under development in our group. Each component of this system can be used separately or combined to improve surgical accuracy, confidence and outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of an operating microscope in animal liver surgery has made it possible to obtain new experimental models. The goal of this prospective animal study is to present our experience with dogfish portocaval microanastomoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apical surgery is an important treatment option for teeth with post-treatment apical periodontitis. Knowledge of the long-term prognosis is necessary when weighing apical surgery against alternative treatments. This study assessed the 5-year outcome of apical surgery and its predictors in a cohort for which the 1-year outcome was previously reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image-guided microsurgery requires accuracies an order of magnitude higher than today's navigation systems provide. A critical step toward the achievement of such low-error requirements is a highly accurate and verified patient-to-image registration. With the aim of reducing target registration error to a level that would facilitate the use of image-guided robotic microsurgery on the rigid anatomy of the head, we have developed a semiautomatic fiducial detection technique. Automatic force-controlled localization of fiducials on the patient is achieved through the implementation of a robotic-controlled tactile search within the head of a standard surgical screw. Precise detection of the corresponding fiducials in the image data is realized using an automated model-based matching algorithm on high-resolution, isometric cone beam CT images. Verification of the registration technique on phantoms demonstrated that through the elimination of user variability, clinically relevant target registration errors of approximately 0.1 mm could be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments using animal models are the most common way to learn microsurgery. This expertise is necessary for liver research, microsurgical reconstruction of the esophagus by free jejunum or reconstruction of the hepatic artery during reimplantation from living donors. The goal of this prospective study is to assess the reliability of an invertebrate model for microsurgical training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The management of patients with small, often asymptomatic meningiomas is controversial and includes observation, microsurgery (MS) and stereotactic radiosurgery (SRS). The purpose of this retrospective study was to analyze the morbidity and the extent of removal after MS for small (< or =3 cm) intracranial meningiomas and compare these results to those of SRS reported in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A retrospective evaluation of glass ionomer cement (GIC) in middle ear surgery with emphasis on short- and long-term safety was conducted at the tertiary referral center. GIC was applied between 1995 and 2006 in 444 patients in otologic surgery. Technical aspects, safety, benefits and complications due to GIC were analysed until 2011 (follow-up 5-16 years; mean 10 years). GIC was applied in stapes surgery (228 primary, 92 revisions), cochlear implants (108) and implantable hearing aids (7), ossiculoplasty (7), for coverage of opened mastoid air cells towards the external ear canal (1) and inner ear fistula closure (1). GIC turned out to be very handy in stapes surgery for optimal prosthesis fixation at the incus (260) and on the malleus handle (60) without complications. Results suggest that GIC may diminish the danger of incus necrosis in primary stapedotomy. In cochlear implants and implantable hearing aids, GIC was used for casing alone (74), casing and electrode fixation (27) and electrode alone fixation (14). Inflammatory reactions were observed in five cases (4.3 %), mostly after trauma. Broken cement fragments appeared to promote foreign body rejection. In seven cases an incudo-stapedial gap was repaired with GIC with excellent hearing gain; in three cases (43 %) revision surgery was needed due to cement breakage. In one case, GIC was applied for a watertight coverage of opened mastoid cells, and in the other for fistula closure of the lateral semi-circular canal over cartilage, covered with bone pathé; follow-up was uneventful. Targeted use of GIC in middle ear surgery rarely poses problems. GIC cannot be used in neuro-otosurgery in contact with cerebrospinal fluid because of possible aluminium encephalopathy.