966 resultados para Micropattern gaseous detectors
Resumo:
This work presents the results on the development of a high pressure Xe gaseous detector envisaging medical imaging. The detector uses two VUV photosensors operating face-to-face, based on the CsI-MHSP with position discrimination capability. The known effect of the charge gain decrease with the gas pressure is compensated with a light gain using the electroluminescence process. Studies of signal amplitude, energy and position resolution are presented. On the second part, gaseous detectors based on THGEM where studied in order to fulfill the requirements of present and future high energy physics experiments. The work is focused on the application of THGEM in RICH detectors elements: a triple THGEM detector using CsI photocathodes in Ne mixtures was suggested. The ion backflow to the photocathode remains a concern and a limitation; to minimize it, the application of a new hole-structure, THCOBRA, was suggested. Preliminary results foresee good perspectives for the successful application of THCOBRA in ion back-flow suppression. This work contains several methods and measurements of the CsI photocathodes behaviour in radiation gaseous detectors. A long discussion on its issues and possible solutions are presented.
Resumo:
Este trabalho descreve o desenvolvimento e aplicação de sistemas baseados em detetores gasosos microestruturados, para imagiologia de fluorescência de raios-X por dispersão em energia (EDXRF). A técnica de imagiologia por fluorescência de raios-X assume-se como uma técnica poderosa, não-destrutiva, em análises da distribuição espacial de elementos em materiais. Os sistemas para imagiologia de EDXRF desenvolvidos são constituídos por: um tubo de raios-X, usado para excitar os elementos da amostra; um detetor gasoso microestruturado; e uma lente pinhole que foca a radiação de fluorescência no plano do detetor formando assim a imagem e permitindo a sua ampliação. Por outro lado é estudada a influência do diâmetro da abertura do pinhole bem como do fator de ampliação obtido para a imagem, na resolução em posição do sistema. Foram usados dois conceitos diferentes de detetores gasosos microestruturados. O primeiro, baseado na microestrutura designada por 2D-Micro-Hole & Strip Plate (2D-MHSP) com uma área ativa de 3 3 cm2, enquanto que o segundo, baseado na estrutura 2D-Thick-COBRA (2D-THCOBRA) apresenta uma área ativa de deteção de 10 10 cm2. Estes detetores de raios-X de baixo custo têm a particularidade de funcionar em regime de fotão único permitindo a determinação da energia e posição de interação de cada fotão que chega ao detetor. Deste modo permitem detetar a energia dos fotões X de fluorescência, bem como obter imagens 2D da distribuição desses fotões X para o intervalo de energias desejado. São por isso adequados a aplicações de imagiologia de EDXRF. Os detetores desenvolvidos mostraram resoluções em energia de 17% e 22% para fotões incidentes com uma energia de 5.9 keV, respectivamente para o detetor 2D-MHSP e 2D-THCOBRA e resoluções em posição adequadas para um vasto número de aplicações. Ao longo deste trabalho é detalhado o desenvolvimento, o estudo das características e do desempenho de cada um dos detetores, e sua influência na performance final de cada sistema proposto. Numa fase mais avançada apresentam-se os resultados correspondentes à aplicação dos dois sistemas a diversas amostras, incluindo algumas do nosso património cultural e também uma amostra biológica.
Resumo:
The development of computed tomography systems with energy resolving detectors is a current challenge in medical physics and biomedical engineering. A computed tomography system of this kind allows getting complementary informations relatively to conventional systems, that can help the medical diagnosis, being of great interest in medicine. The work described in this thesis is related to the development of a computed tomography system using micropattern gaseous detectors, which allow storing, simultaneously, information about the interaction position and the energy of each single photon that interacts with the detector. This kind of detectors has other advantages concerning the cost and characteristics of operation when compared with solid state detectors. Tomographic acquisitions were performed using a MicroHole & Strip Plate based detector, which allowed reconstructing cross-sectional images using energy windows, applying the energy weighting technique and performing multi-slice and tri-dimensional reconstructions. The contrast-to-noise ratio was improved by 31% by applying the energy weighting technique, comparing with the corresponding image obtained with the current medical systems. A prototype of a computed tomography with flexibility to change the detector was developed, making it possible to apply different detectors based on Thick-COBRA. Several images acquired with these detectors are presented and demonstrate their applicability in X-ray imaging. When operating in NeCH4, the detector allowed a charge gain of 8 104, an energy resolution of 20% (full width at half maximum at 8 keV), a count rate of 1 106 Hz/mm2, a very stable operation (gain fluctuations below 5%) and a spacial resolution of 1.2 mm for an energy photon of 3.6 keV. Operating the detector in pure Kr allowed increasing the detection efficiency and achieving a charge gain of 2 104, an energy resolution of 32% (full width at half maximum at 22 keV), a count rate of 1 105 Hz/mm2, very stable operation and a spatial resolution of 500 m. The software already existing in the group was improved and tools to correct geometric misalignments of the system were also developed. The reconstructions obtained after geometrical correction are free of artefacts due to the referred misalignments.
Resumo:
A Micro-Hole & Strip Plate (MHSP) é uma microestrutura desenvolvida recentemente em instituições universitárias portuguesas. Neste trabalho, o seu desempenho como detector para imagiologia é explorado, tendo como objectivo a imagiologia não só de neutrões, mas também de raios X. A aplicação do método da divisão resistiva de carga é aplicada a uma MHSP especialmente desenhada para sensibilidade em posição. Várias abordagens em termos da electrónica de aquisição de sinal são testadas, sem perder de vista a relação desempenho-preço. Resoluções espaciais abaixo de 1 mm foram obtidas com a MHSP a operar em xénon e tetrafluorometano, com um sistema de detecção a um preço modesto quando comparado com as alternativas, e apropriado para inúmeras aplicações em imagiologia de neutrões e de raios X.
Resumo:
气体探测器是历史最悠久的核探测器之一气体探测器具有成本低廉、制备简单、性能可靠和使用方便等特点。而且气体探测器的形状和尺寸可任意设计,厚度可随气体气压的变化而改变,适合做大面积位置灵敏、大立本角探测和有较宽的动态测量范围。所以气体探测器在各自的应用范围内发挥着巨大的作用。在兰州放射性束流线(RIBLL)上开展次级束实验的过程中,束流的定位和发散度测定都是非常重要的。我们研制了两种高性能的双维位置灵勘平行板雪崩计数器(PPAC),一种为传统的三个极板结构,另外一种为五个极板的多极结构,分别适用于较重粒子和轻粒子的位置测量。对于五个极板的多极结构的探测器,灵敏面积为100mm×100mm,采用电荷分除法读出位置,我们用3组分α源测试,工作气体选用异丁烷。测试在6.5mb气压下,位置分辨为0.55mm(FWHM),探测效率大于99.2%,位置离散小于士0.2mm。一系列的性能指标都达到了同类探测器的最好水平。该探测器和以前研制的三极板PPAC的性能均已满足RIBLL的要求,将会用作RIBLL重要的束诊元件和位置探测器。同时改进后还能在即将建成的兰州重离子加速器冷却存储环(HIRFL-CSR)上的束流诊断过程中发挥重要的作用。同时,为在RIBLL上开展超重元素和超重核素的合成实验研制了一种多阳极横向场气体电离室(MAIC)。在100mbP10气体下,对应第四块大灵敏区域,5.806MeV~(244)Cm的α粒子的能量损失为1.30MeV,得出该探测器的能量分辨为41.1keV(FwHM),相对分辨为3.16%。该探测器适合于较重粒子的鉴别,性能指标已经满足RIBLL鉴glI灼子的要求。
Resumo:
Uma descrição detalhada do processo de electroluminescência é um prérequisito na optimização de detectores gasosos para sistemas de imagiologia, astrofísica, física de altas energias e experiências de eventos raros. Neste trabalho, é apresentada e caracterizada uma nova e versátil plataforma de simulação da emissão de luz durante a deriva de electrões em gases nobres, desenvolvida usando os programas Magboltz e Garfield. Propriedades intrínsecas da electroluminescência em gases nobres são calculadas e apresentadas em função do campo eléctrico aplicado, nomeadamente eficiências, rendimento e flutuações estatísticas associadas. São obtidos resultados em grande concordância com dados experimentais e simulações Monte Carlo anteriores. A plataforma é usada para determinar as condições óptimas de funcionamento de detectores como o NEXT (Neutrino Experiment with a Xenon TPC) e outros baseados nas micro-estruturas GEM (Gas Electron Multiplier) e MHSP (Micro- Hole & Strip Plate).
Resumo:
Cherenkov Imaging counters require large photosensitive areas, capable of single photon detection, operating at stable high gains under radioactive backgrounds while standing high rates, providing a fast response and a good time resolution, and being insensitive to magnetic fields. The development of photon detectors based in Micro Pattern Gaseous detectors (MPGDs), represent a new generation of gaseous photon detectors. In particular, gaseous detectors based on stacked Thick-Gaseous Electron Multipliers (THGEMs), or THGEM based structures, coupled to a CsI photoconverter coating, seem to fulfil the requirements imposed by Cherenkov imaging counters. This work focus on the study of the THGEM-based detectors response as function of its geometrical parameters and applied voltages and electric fields, aiming a future upgrade of the Cherenkov Imaging counter RICH-1 of the COMPASS experiment at CERN SPS. Further studies to decrease the fraction of ions that reach the photocathode (Ion Back Flow – IBF) to minimize the ageing and maximize the photoelectron extraction are performed. Experimental studies are complemented with simulation results, also perfomed in this work.
Resumo:
The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.
Resumo:
The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 pb-1 of data collected in pp collisions at s = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV/c is above 95% over the whole region of pseudorapidity covered by the CMS muon system, < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeVc is higher than 90% over the full η range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100GeV/c and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV/c. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation. © 2012 IOP Publishing Ltd and Sissa Medialab srl.
Resumo:
COMPASS is an experiment at CERN’s SPS whose goal is to study hadron structure and spectroscopy. The experiment includes a wide acceptance RICH detector, operating since 2001 and subject to a major upgrade of the central region of its photodetectors in 2006. The remaining 75% of the photodetection area are still using MWPCs from the original design, who suffer from limitations in gain due to aging of the photocathodes from ion bombardment and due to ion-induced instabilities. Besides the mentioned limitations, the increased luminosity conditions expected for the upcoming years of the experiment make an upgrade to the remaining detectors pertinent. This upgrade should be accomplished in 2016, using hybrid detectors composed of ThGEMs and MICROMEGAS. This work presents the study, development and characterization of gaseous photon detectors envisaging the foreseen upgrade, and the progress in production and evaluation techniques necessary to reach increasingly larger area detectors with the performances required. It includes reports on the studies performed under particle beam environment of such detectors. MPGD structures can also be used in a variety of other applications, of which nuclear medical imaging is a notorious example. This work includes, additionally, the initial steps in simulating, assembling and characterizing a prototype of a gaseous detector for application as a Compton Camera.
Resumo:
The detection efficiency of a GEM based UV sensitive gaseous photomultiplier (GPM) depends on the focusing of electrons from the drift gap to the GEM aperture. We have studied the effect of drift parameters on the efficiency of electron focusing into Thick GEM (THGEM) holes in a GPM with semitransparent UV photoconverter. This study comprises simulation of electron focusing into THGEM holes using GARFIELD for different Ar and Ne based gas mixtures and experimental investigations of the same with P10 gas mixture. (c) 2013 Elsevier B.V. All rights reserved.
Resumo:
In this study, it was developed a methodology for the determination of the dispersion of a gaseous tracer in porous media using the radiotracer technique. In order to evaluate several porous media, a cylindrical filter was constructed in PVC and connected to a system with constant flow. Inside this unit silica crystals (16-20) mesh was used as porous media and CH3Br (Methyl Bromide) marked with 82Br was used as radiotracer. An instantaneous pulse of tracer was applied in the system entrance and registered by two NaI (3x3)” scintillation detectors located one before and the other after the filter. The curves produced by the radioactive cloud and recorded by the detector were analyzed statistically using the weighted moment method. The mathematical model one considered as great dispersion of tracer was used to evaluate the flow conditions inside the filter system. The results show us that the weight moment method associated with radiotracer techniques is useful to evaluated an industrial filter and allows to measure the residence time distribution, τ, and the axial dispersion, DAB, gas in a porous medium.
Resumo:
A novel technique was used to measure emission factors for commonly used commercial aircraft including a range of Boeing and Airbus airframes under real world conditions. Engine exhaust emission factors for particles in terms of particle number and mass (PM2.5), along with those for CO2, and NOx were measured for over 280 individual aircraft during the various modes of landing/takeoff (LTO) cycle. Results from this study show that particle number, and NOx emission factors are dependant on aircraft engine thrust level. Minimum and maximum emissions factors for particle number, PM2.5, and NOx emissions were found to be in the range of 4.16×1015-5.42×1016 kg-1, 0.03-0.72 g.kg-1, and 3.25-37.94 g.kg-1 respectively for all measured airframes and LTO cycle modes. Number size distributions of emitted particles for the naturally diluted aircraft plumes in each mode of LTO cycle showed that particles were predominantly in the range of 4 to 100 nm in diameter in all cases. In general, size distributions exhibit similar modality during all phases of the LTO cycle. A very distinct nucleation mode was observed in all particle size distributions, except for taxiing and landing of A320 aircraft. Accumulation modes were also observed in all particle size distributions. Analysis of aircraft engine emissions during LTO cycle showed that aircraft thrust level is considerably higher during taxiing than idling suggesting that International Civil Aviation Organization (ICAO) standards need to be modified as the thrust levels for taxi and idle are considered to be the same (7% of total thrust) [1].