14 resultados para Microfocus


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have focused a beam (BL3) of FLASH (Free-electron LASer in Hamburg: lambda = 13.5 nm, pulse length 15 fs, pulse energy 10-40 mu J, 5Hz) using a fine polished off-axis parabola having a focal length of 270 mm and coated with a Mo/Si multilayer with an initial reflectivity of 67% at 13.5 nm. The OAP was mounted and aligned with a picomotor controlled six-axis gimbal. Beam imprints on poly(methyl methacrylate) -PMMA were used to measure focus and the focused beam was used to create isochoric heating of various slab targets. Results show the focal spot has a diameter of

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiolarians in the Arctic Ocean have been studied lately in both plankton and sediment trap samples in the Chukchi Sea area. These studies have shed light on new radiolarian taxa, especially within the order Entactinaria, including two new species of Joergensenium, Joergensenium arcticum from the western Arctic Ocean, so far restricted to the Pacific Winter Water in the Chukchi Sea, and Joergensenium clevei hitherto found in the northern part of the Norwegian Sea south of the Fram Strait. The taxonomic position of the order Entactinaria is discussed and the genus Joergensenium has been emended. We have also observed in detail the internal structure of J. arcticum using Microfocus X-ray Computed Tomography and have utilized three-dimensional imaging for the first time in a species description.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function - MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device. © 2009 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Animal - FMVA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cryptococcosis is an opportunistic fungal infection caused by Cryptococcus yeasts, especially C. neoformans and Cryptococcus gattii. The fungus is found in substrates of animal and vegetable origin, and infection occurs through inhalation and seedlings present in the environment. The present study aimed to investigate the existence of microfocus Cryptococcus sp. from the environmental samples of Araçatuba city, São Paulo, featuring new niches, by decoupling the direct relationship between fungus and host in order to minimize the risk of contamination of man and animals, understanding the ecoepidemiology of Cryptococcus. Fifty samples from hollows and tree trunks were harvested (Cassia sp., Ficus sp., Caesalpinea peltophorides) from ten representatives in the urban perimeter. The samples were immediately sent to the Laboratory of Bacteriology and Mycology, Faculty of Veterinary Medicine Araçatuba - Unesp where they were processed and plated on Petri dishes containing agar seed Niger and Sabouraud dextrose agar with chloramphenicol, incubated at 30ºC for a period of no less than 5 days. Afterwards they were subimitted to biochemical tests: urease production, thermotolerance at 37°C and quimiotipagem in CGB agar (L- Canavanine-Glycine-Bromothymol blue). The results showed that 17 (34%) cultures were positive for Cryptococcus, 9 (18%) for Cryptococcus gattii and 8 (16%) for Cryptococcus neoformans. Other yeast correlated as Rhodotorula sp. and Candida sp. were isolated. We conclude that the infectious propagules of Cryptococcus are dispersed in nature and constitute an environmental microfocus, not necessarily being bound to a single host.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In der vorliegenden Arbeit wurden Untersuchungen zur Aufklärung des Versagens thermisch verschweißter Polymergrenzflächen (hier: Polymethylmethacrylat) durchgeführt. Solch ein Wissen kommt in der Praxis bei sogenannten Sollbruchstellen zum Einsatz. Dabei muss die Grenzschicht bis zu einer bestimmten Belastungsintensität stabil bleiben bei höherer Belastung jedoch brechen. Zudem ist eine stabile Risspropagation entlang der Grenzschicht wichtig.Neben der Bruchstabilitätsbestimmung mit Hilfe des Double Cantilever Beam Tests wurden die beim Versagen der Grenzschicht entstandenen Defekte untersucht. Die Analyse der Bruchfläche erfolgte mit Mikroskopie und Höhenprofilometrie. Defekte im Volumen wurden durch Scanning-Ultra Small Angle X-ray Scattering und Scanning Microfokus-Small Angle X-ray Scattering untersucht.Im Modellsystem können Sollbruchstellen bis zu einer Belastungsintensität von maximal 280J/m² durch die Verschweißungsdauer eingestellt werden. Die Untersuchung der Bruchflächen lieferte ein kombiniertes Modell aus Ausheil- und Interdiffusionsprozess. Ferner folgt aus den Streuuntersuchungen, dass beim Modellsystem keine hochgeordneten Defektstrukturen vorliegen. Die entstandenen Strukturen folgen einem Modell diffuser Defektgrenzflächen. Über die gemessene Diffusivität kann zudem auf die Energiedissipation im Bereich um das Rissende geschlossen werden. Sie ist im unmittelbaren Rissbereich am Höchsten und nimmt mit Entfernung davon ab. Dabei haben die Defektbereiche eine Größe bis zu 650µm. Die Richtung der von außen angelegten Belastung spielt bei der räumlichen Orientierung der Defekte keine Rolle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interest in automatic volume meshing for finite element analysis (FEA) has grown more since the appearance of microfocus CT (μCT), due to its high resolution, which allows for the assessment of mechanical behaviour at a high precision. Nevertheless, the basic meshing approach of generating one hexahedron per voxel produces jagged edges. To prevent this effect, smoothing algorithms have been introduced to enhance the topology of the mesh. However, whether smoothing also improves the accuracy of voxel-based meshes in clinical applications is still under question. There is a trade-off between smoothing and quality of elements in the mesh. Distorted elements may be produced by excessive smoothing and reduce accuracy of the mesh. In the present work, influence of smoothing on the accuracy of voxel-based meshes in micro-FE was assessed. An accurate 3D model of a trabecular structure with known apparent mechanical properties was used as a reference model. Virtual CT scans of this reference model (with resolutions of 16, 32 and 64 μm) were then created and used to build voxel-based meshes of the microarchitecture. Effects of smoothing on the apparent mechanical properties of the voxel-based meshes as compared to the reference model were evaluated. Apparent Young’s moduli of the smooth voxel-based mesh were significantly closer to those of the reference model for the 16 and 32 μm resolutions. Improvements were not significant for the 64 μm, due to loss of trabecular connectivity in the model. This study shows that smoothing offers a real benefit to voxel-based meshes used in micro-FE. It might also broaden voxel-based meshing to other biomechanical domains where it was not used previously due to lack of accuracy. As an example, this work will be used in the framework of the European project ContraCancrum, which aims at providing a patient-specific simulation of tumour development in brain and lungs for oncologists. For this type of clinical application, such a fast, automatic, and accurate generation of the mesh is of great benefit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main goal of this study was to relate physical changes in image quality measured by Modulation Transfer Function (MTF) to diagnostic accuracy.^ One Hundred and Fifty Kodak Min-R screen/film combination conventional craniocaudal mammograms obtained with the Pfizer Microfocus Mammographic system were selected from the files of the Department of Radiology, at M.D. Anderson Hospital and Tumor Institute.^ The mammograms included 88 cases with a variety of benign diagnosis and 62 cases with a variety of malignant biopsy diagnosis. The average age of the patient population was 55 years old. 70 cases presented calcifications with 30 cases having calcifications smaller than 0.5mm. 46 cases presented irregular bordered masses larger than 1 cm. 30 cases presented smooth bordered masses with 20 larger than 1 cm.^ Four separated copies of the original images were made each having a different change in the MTF using a defocusing technique whereby copies of the original were obtained by light exposure through different thicknesses (spacing) of transparent film base.^ The mammograms were randomized, and evaluated by three experienced mammographers for the degree of visibility of various anatomical breast structures and pathological lesions (masses and calicifications), subjective image quality, and mammographic interpretation.^ 3,000 separate evaluations were anayzed by several statistical techniques including Receiver Operating Characteristic curve analysis, McNemar test for differences between proportions and the Landis et al. method of agreement weighted kappa for ordinal categorical data.^ Results from the statistical analysis show: (1) There were no statistical significant differences in the diagnostic accuracy of the observers when diagnosing from mammograms with the same MTF. (2) There were no statistically significant differences in diagnostic accuracy for each observer when diagnosing from mammograms with the different MTF's used in the study. (3) There statistical significant differences in detail visibility between the copies and the originals. Detail visibility was better in the originals. (4) Feature interpretations were not significantly different between the originals and the copies. (5) Perception of image quality did not affect image interpretation.^ Continuation and improvement of this research ca be accomplished by: using a case population more sensitive to MTF changes, i.e., asymptomatic women with minimum breast cancer, more observers (including less experienced radiologists and experienced technologists) must collaborate in the study, and using a minimum of 200 benign and 200 malignant cases.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After decades of slow progress, the pace of research on membrane protein structures is beginning to quicken thanks to various improvements in technology, including protein engineering and microfocus X-ray diffraction. Here we review these developments and, where possible, highlight generic new approaches to solving membrane protein structures based on recent technological advances. Rational approaches to overcoming the bottlenecks in the field are urgently required as membrane proteins, which typically comprise ~30% of the proteomes of organisms, are dramatically under-represented in the structural database of the Protein Data Bank.