981 resultados para Microfluidic Systems
Resumo:
Doppler Optical Coherence Tomography (DOCT) is a biomedical imaging technique that allows simultaneous structural imaging and flow monitoring inside biological tissues and materials with spatial resolution in the micrometer scale. It has recently been applied to the characterization of microfluidic systems. Structural and flow imaging of novel microfluidics platforms for cytotoxicologic applications were obtained with a real-time, Near Infrared Spectral Domain DOCT system. Characteristics such as flow homogeneity in the chamber, which is one of the most important parameters for cell culture, are investigated. OCT and DOCT images were used to monitor flow inside a specific platform that is based on microchannel division for a better flow homogeneity. In particular, the evolution of flow profile at the transition between the microchannel structure and the chamber is studied.
Resumo:
There are situations in which it is very important to quickly and positively identify an individual. Examples include suspects detained in the neighborhood of a bombing or terrorist incident, individuals detained attempting to enter or leave the country, and victims of mass disasters. Systems utilized for these purposes must be fast, portable, and easy to maintain. The goal of this project was to develop an ultra fast, direct PCR method for forensic genotyping of oral swabs. The procedure developed eliminates the need for cellular digestion and extraction of the sample by performing those steps in the PCR tube itself. Then, special high-speed polymerases are added which are capable of amplifying a newly developed 7 loci multiplex in under 16 minutes. Following the amplification, a postage stamp sized microfluidic device equipped with specially designed entangled polymer separation matrix, yields a complete genotype in 80 seconds. The entire process is rapid and reliable, reducing the time from sample to genotype from 1-2 days to under 20 minutes. Operation requires minimal equipment and can be easily performed with a small high-speed thermal-cycler, reagents, and a microfluidic device with a laptop. The system was optimized and validated using a number of test parameters and a small test population. The overall precision was better than 0.17 bp and provided a power of discrimination greater than 1 in 106. The small footprint, and ease of use will permit this system to be an effective tool to quickly screen and identify individuals detained at ports of entry, police stations and remote locations. The system is robust, portable and demonstrates to the forensic community a simple solution to the problem of rapid determination of genetic identity.
Resumo:
[EN] Therefore the understanding and proper evaluation of the flow and mixing behaviour at microscale becomes a very important issue. In this study, the diffusion behaviour of two reacting solutions of HCI and NaOH were directly observed in a glass/polydimethylsiloxane microfluidic device using adaptive coatings based on the conductive polymer polyaniline that are covalently attached to the microchannel walls. The two liquid streams were combined at the junction of a Y-shaped microchannel, and allowed to diffuse into each other and react. The results showed excellent correlation between optical observation of the diffusion process and the numerical results. A numerical model which is based on finite volume method (FVM) discretisation of steady Navier-Stokes (fluid flow) equations and mass transport equations without reactions was used to calculate the flow variables at discrete points in the finite volume mesh element. The high correlation between theory and practical data indicates the potential of such coatings to monitor diffusion processes and mixing behaviour inside microfluidic channels in a dye free environment.
Resumo:
Microfluidic systems have become competitive tools in the invitro modelling of diseases and promising alternatives to animal studies. They allow obtaining more invivo like conditions for cellular assays. Research in idiopathic pulmonary fibrosis could benefit from this novel methodological approach to understand the pathophysiology of the disease & develop efficient therapies. The use of hepatocyte growth factor (HGF) for alveolar reepithelisation is a promising approach. In this study, we show a new microfluidic system to analyse the effects of HGF on injured alveolar epithelial cells. Microfluidic systems in polydimethylsiloxane were fabricated by soft lithography. The alveolar A549 epithelial cells (10,000 cells) were seeded and studied in these microfluidic systems with media perfusion (1μl/30min). Injury tests were made on the cells by the perfusion with media containing H2O2 or bleomycin. The degree of injury was then assessed by a metabolic and an apoptotic assays. Wound assays were also performed with a central laminar flow of trypsin. Monitoring of wound closure with HGF vs control media was assessed. The alveolar A549 epithelial cells grew and proliferated in the microfluidic system. In the wound closure assay, the degree of wound closure after 5 hours was (53.3±1.3%) with HGF compared to (9.8±2.4%) without HGF (P <0.001). We present a novel microfluidic model that allows culture, injury and wounding of A549 epithelial cells and represents the first step towards the development of an invitro reconstitution of the alveolar-capillary interface. We were also able to confirm that HGF increased alveolar epithelial repair in this system.
Resumo:
Background: Microfluidics system are novel tools to study cell-cell interactions in vitro. This project focuses on the development of a new microfluidic device to co-culture alveolar epithelial cells and mesenchymal stem cells to study cellular interactions involved in healing the injured alveolar epithelium. Methods: Microfluidic systems in polydimethylsiloxane were fabricated by soft lithography. The alveolar A549 epithelial cells were seeded and injury tests were made on the cells by perfusion with media containing H2O2 or bleomycin during 6 or 18hrs. Rat Bone marrow derived stromal cells (BMSC) were then introduced into the system and cell-cell interaction was studied over 24 hrs. Results: A successful co-culture of A549 alveolar epithelial cells and BMS was achieved in the microfluidic system. The seeded alveolar epithelial cells and BMSC adhered to the bottom surface of the microfluidic device and proliferated under constant perfusion. Epithelial injury to mimic mechanisms seen in idiopathic pulmonary fibrosis was induced in the microchannels by perfusing with H2O2 or bleomycin. Migration of BMSC towards the injured epithelium was observed as well as cell-cell interaction between the two cell types was also seen. Conclusion: We demonstrate a novel microfluidic device aimed at showing interactions between different cell types on the basis of a changing microenvironment. Also we were able to confirm interaction between injured alvolar epithelium and BMSC, and showed that BMSC try to heal the injured epitelium.
Resumo:
The present dissertation aimed to develop a new microfluidic system for a point-of-care hematocrit device. Stabilization of microfluidic systems via surfactant additives and integration of semipermeable SnakeSkin® membranes was investigated. Both methods stabilized the microfluidic systems by controlling electrolysis bubbles. Surfactant additives, Triton X-100 and SDS stabilized promoted faster bubble detachment at electrode surfaces by lowering surface tension and decreased gas bubble formation by increasing gas solubility. The SnakeSkin® membranes blocked bubbles from entering the microchannel and thus less disturbance to the electric field by bubbles occurred in the microchannel. Platinum electrode performance was improved by carbonizing electrode surface using red blood cells. Irreversibly adsorbed RBCs lysed on platinum electrode surfaces and formed porous carbon layers while current response measurements. The formed carbon layers increase the platinum electrode surface area and thus electrode performance was improved by 140 %. The microfluidic system was simplified by employing DC field to use as a platform for a point-of-care hematocrit device. Feasibility of the microfluidic system for hematocrit determination was shown via current response measurements of red blood cell suspensions in phosphate buffered saline and plasma media. The linear trendline of current responses over red blood cell concentration was obtained in both phosphate buffered saline and plasma media. This research suggested that a new and simple microfluidic system could be a promising solution to develop an inexpensive and reliable point-of-care hematocrit device.
Resumo:
This paper critically analyzes, for the first time, the effect of nanofluid on thermally fully developed magnetohydrodynamic flows through microchannel, by considering combined effects of externally applied pressure gradient and electroosmosis. The classical boundary condition of uniform wall heat flux is considered, and the effects of viscous dissipation as well as Joule heating have been taken into account. Closed-form analytical expressions for the pertinent velocity and temperature distributions and the Nusselt number variations are obtained, in order to examine the role of nanofluids in influencing the fully developed thermal transport in electroosmotic microflows under the effect of magnetic field. Fundamental considerations are invoked to ascertain the consequences of particle agglomeration on the thermophysical properties of the nanofluid. The present theoretical formalism addresses the details of the interparticle interaction kinetics in tune with the pertinent variations in the effective particulate dimensions, volume fractions of the nanoparticles, as well as the aggregate structure of the particulate system. It is revealed that the inclusion of nanofluid changes the transport characteristics and system irreversibility to a considerable extent and can have significant consequences in the design of electroosmotically actuated microfluidic systems.
Resumo:
The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices. © 2010 IOP Publishing Ltd.
Resumo:
微尺度相变传热广泛存在于微反应器、微型燃料电池、微蒸发器、微冷凝器、微热管、微汽泡执行器等微流控器件中,研究微流控系统中的相变问题对于微流控器件的设计和运行具有重要的科学意义。本文针对三类典型的微尺度相变问题,即微尺度流动沸腾、微尺度流动凝结以及微加热器上的汽泡动力学进行了深入细致的研究,实验研究中所采用的实验件均为标准MEMS微加工工艺制作,克服了常规机械加工所造成的表面粗糙度的影响。 考虑到微流控系统中大量应用交叉型、弯曲型等复杂结构的微通道,在微尺度流动沸腾研究中,设计了一种具有交错微通道结构的微流控芯片,并以丙酮为工质,对该芯片内的流动沸腾进行了研究。发现了周期为毫秒量级微时间尺度的流型结构,整个周期包括单相液体充液、两相分层流以及部分蒸干的液膜流三个阶段;在单个微通道区域,由于蒸发动量力的作用,液膜沿流动方向呈非均匀分布,蒸干首先发生在上游;由于液相弗劳德数较小,导致微通道中依然存在分层流流型。由于毕渥数较小,芯片背面温度几乎与芯片内壁面温度保持同步变化。虽然红外热像仪的响应频率较低,但仍然可以鉴别出由于流型周期性转换导致的壁面温度脉动。 在微尺度流动凝结换热研究中,为便于获取凝结过程的动态流动特性,设计了一种低高宽比的单微通道,并以水为工质,对该微通道中的流动凝结换热进行了研究。实验中采取了空气自然对流冷却和 水强制对流冷却两种冷却强度。研究发现,该微通道中的凝结换热呈周期性,其周期在毫秒量级。在通道上游入口处,存在一个呈准静止状态的长汽弹,汽弹前端周期性脱离汽泡。增加冷却强度会使汽泡的脱离频率增大,脱离直径减小;长汽弹前端周期性脱离汽泡是由于汽液界面具有较大的韦伯数。汽泡在该微通道内的运动过程中直径基本不变是由于汽泡在通道内的滞留时间远小于汽泡完全冷凝所需的总时间。 为澄清并联通道的多通道效应对微尺度凝结换热的影响,作者设计了由三个矩形通道组成的并联微通道冷凝器。研究发现,通道中的流型结构与单通道凝结过程类似,均为上游呈准静止状态的长汽弹和下游周期性的汽泡脱离。在中间通道和侧通道中,总共发现了三种不同的汽泡脱离模式,即单汽丝断裂模式、双汽丝同步断裂模式以及双汽丝非同步断裂模式。多通道效应主要表现在由于硅基固体导热的影响,三个通道中具有不同的温度分布,中间通道的温度关于其中心线成对称分布,而两侧通道中的高温区域均靠向中间通道。虽然硅具有良好的导热性,整个硅基上的温差很小,但在微尺度下,小温差依然可以导致较大的温度梯度,造成中间通道的双汽丝关于其中心线成对称分布,并且总是发生同步断裂;侧通道中的双汽丝偏向中间通道,并且在靠近中间通道的一侧汽丝总是首先发生断裂。由于温度梯度引起的Maragnoni对流效应,侧通道中的汽泡脱离后便靠向高温侧。 在微汽泡动力学研究中,设计了一种尺寸为 的Pt薄膜微加热器,研究了脉冲控制参数对微加热器上汽泡动力学特性的影响。研究发现在该微加热器上发生汽泡核化时,核化温度均达到液体的过热极限,因此为均质核化过程。在不同的脉冲控制参数下,存在三类不同的汽泡动力学特性,即(1)汽泡爆炸性生长和冷凝以及汽泡二次生长;(2)汽泡爆炸性生长继而分裂、吸引并聚合;(3)汽泡振荡生长而后持续生长并最终达到稳定状态。在第(1)类中,汽泡二次生长是由于脉冲加热过程中在玻璃基片上储存了热量;在第(2)类中,汽泡冷凝过程中的Marangoni效应导致分裂后的汽泡互相吸引并最终聚合。在第(3)类中,汽泡尺寸最终达到稳定是由于汽泡内蒸汽的发生量与汽液界面上蒸汽的凝结量相等。 本文的研究将为微反应器、微型燃料电池、微换热器、微汽泡执行器等相变微流控系统的设计和运行提供科学指导。
Resumo:
细胞生物学研究的一个重要方向是动态地控制细胞在基底上的黏附。最近,随着表面化学的研究深入,尤其是对烷基硫醇在金基底上形成自组装单层膜(self-assembled monolayers, SAMs)这一体系的研究,使得人们能在分子水平的表面上控制细胞黏附。精氨酸-甘氨酸-天冬氨酸(arginine-glycine-aspartate, RGD)序列首先是从细胞外基质蛋白中分离出来的,能够识别并非共价结合细胞膜表面的整合素受体,从而促进细胞黏附。以前的一些工作已经证实,将含有RGD的肽链连接到SAMs表面之后,能够生物特异性地黏附动物细胞。已有的手段比如光照、电压、加热、微电极、微流控以及表面纳米形貌的梯度变化,都不能真正实现可逆地控制细胞黏附,原因是这些方法所用的化学有限;这些方法也不能得到完全抗拒细胞黏附的表面,原因是这些方法产生的表面缺陷等不完整。用两种不同波长的光(紫外光和可见光)照射偶氮苯,偶氮苯会发生可逆的光致异构变化,因此,偶氮苯的光致异构性质可以用来可逆地控制细胞在表面黏附。运用含有偶氮苯的混合SAMs,偶氮苯的末端连接GRGDS肽,混合SAMs中是以末端为六聚乙二醇的硫醇为背景,该SAMs修饰而成的表面能够黏附或者抗拒细胞黏附,其表面黏附性质取决于SAMs中偶氮苯的构象。该方法提供了一种在分子水平的表面上我们所了解到的唯一能可逆控制细胞黏附的方法,该方法需要用到的光源来自于标准荧光显微镜所配置的汞灯。 为了实现在金基底表面可逆的控制细胞黏附,我们合成了如下三个化合物: 由于化合物1的溶解性很差,几乎在所有溶剂里都不溶,所以不能直接用化合物1制备SAMs;化合物2能高效地抗拒细胞的黏附;化合物3的偶氮苯末端是活化酯,能够连接GRGDS肽,从而控制细胞黏附。 将化合物2和化合物3以一定的比例均匀混合在金基底表面形成SAMs,然后将GRGDS肽连接到偶氮苯(反式)的末端(通过GRGDS肽的甘氨酸上的伯胺基与偶氮苯末端的活化酯反应),从而得到细胞黏附的表面。用紫外光照射该细胞黏附表面5-10小时,随着偶氮苯的构象由反式变为顺式,偶氮苯末端的GRGDS肽淹没在化合物2的六聚乙二醇中,得到抗拒细胞黏附的惰性表面。再用可见光照射该惰性表面1个小时,随着偶氮苯的构象由顺式变为反式,原先埋没在六聚乙二醇中的GRGDS肽伸展至单层膜的末端,又得到了细胞黏附的表面。因此,该表面能完全可逆地控制细胞在金表面黏附。 An important area in cell biology is the dynamic control of cell adhesion on substrates. Recent advancements in surface chemistry, in particular, self-assembled monolayers (SAMs) of alkanethiols on gold substrates, have permitted unprecedented control of cell adhesion via molecularly defined surfaces. The tri-peptide sequence arginine-glycine-aspartate (RGD), initially isolated from the extracellular matrix (ECM) proteins, can recognize and non-covalently bind with integrin receptors on cell membranes to promote cell adhesion. Some previous work has demonstrated that RGD peptide grafted on SAMs can allow bio-specific adhesion of mammalian cells that mimic natural adhesion. Existing technologies such as light, voltage, heat, microelectrodes, microfluidic systems and surface gradient of nanotopography, either cannot realize fully reversible control of cell adhesion, due to the limitation in the chemistry used, or cannot yield a surface completely resistant against cell adhesion, due to the imperfection of surfaces. Azobenzenes undergo reversible photo-induced isomerization rapidly at two different wavelengths of light (UV and visible light), it therefore potentially allows the reversible control of cell adhesion on a surface. By using a mixed SAMs presenting azobenzene groups terminated in GRGDS peptides in a background of hexa(ethylene glycol) groups, the surface can either accommodate or resist cell adhesion depending on the conformation of the azobenzene embedded in SAMs. This method provides the only means we know to control cell adhesion reversibly on a molecularly well-defined surface by using light generated by a mercury lamp equipped on standard fluorescence microscopes. To realize the reversible control of cell adhesion on gold surface, we synthesized three kinds of compounds as following, We found that it was difficult to obtain SAMs directly from compound 1 because of its poor solubility in almost all kinds of solvents; compound 2 can resist cell adhesion efficiently; compound 3 presents an azobenzene terminated with NHS-activated ester, which can couple with a GRGDS peptide to control cell adhesion. After coating a gold surface with compound 2 and 3 in appropriate ratios to form a SAM followed by coupling the GRGDS peptides with NHS-activated esters at the end of azobenzene (E configuration) resulted in a cell-adhesive SAM. Irradiating this cell-adhesive SAM with UV light for 5-10 h converted the E configuration of azobenzene into the Z form, the GRGDS peptides becoming masked in the PEG, resulting in a cell-resistant surface. These SAM could again support cell adhesion as a result of the conformational switch of azobenzene from Z to E with the irradiation of visible light for 1 h. This surface, therefore, allows completely reversible control of cell adhesion on a gold surface.
Resumo:
Herein, one water-soluble functionalized ionic liquid (IL), 1-butyl-3-methylimidazolium dodecanesulfonate (BAS), was designed, investigated and successfully applied to microchip micellar electrokinetic chromatography (MEKC) construction. It possessed the properties of both IL and surfactant. A fairly stable pH value similar to 7.4, which was fit to pH values of general biological buffers, was nicely placed at the optimum concentration of 20 mM BAS solution. While applying BAS solution as running buffer in poly(dimethylsiloxane) (PDMS) microfluidic systems, significantly enhanced electroosmotic flow (8-fold) and resolutions between analytes were obtained than that using other supporting electrolytes or surfactants.
Resumo:
An on-chip disk electrode based on sol-gel-derived carbon composite material could be easily and reproducibly fabricated. Unlike other carbon-based electrodes reported previously, this detector is rigid, convenient to fabricate, and amenable to chemical modifications. Based on the stable and reproducible characters of this detector, a copper particle-modified detector was developed for the detection of carbohydrates which extends the application of the carbon-based electrode. In our experiments, the performance of the new integrated detector for rapid on-chip measurement of epinephrine and glucose was illustrated. Experimental procedures including the fabrication of this detector, the configuration of separation channel outlet and electrode verge, and the performance characteristics of this new electrochemical detector were investigated.