29 resultados para Microcantilevers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption of dopamine (DA) molecules on gold and their interactions with Fe3+ were studied by a microcantilever in a flow cell. The microcantilever bent toward the Au side with the adsorption of DA due to the change Of Surface stress induced by the intermolecular hydrogen bonds of DA or the charge transfer effect between adsorbates and the Substrate. The interaction process between DA adsorbates and Fe3+ was revealed by the deflection curves of microcantilever. As indicated by the appearance of a variation during the decline of curves, two steps were observed in the curve at relative high concentrations of Fe3+. In this case, Fe3+ reacted with DA molecules only in the outer layers and the complexes removed with solution. Then Fe3+ reacted further with DA molecules forming the surface complex in the first layer next to the gold. At this stage, the stability Of Surface complexes was time dependent, i.e., unstable initially and stable finally. This may be due to the surface complexes change from mono-dentate to bi-dentate complexes. In another case, i.e., at relative low concentration of Fe3+, only the first step was observed as indicated by the absence of a variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gly-Gly-His tripeptide modified microcantilever was developed by carbodiimide attachment of the Gly-Gly-His tripeptide onto a 3-mercaptopropionic acid(MPA) modified gold surface. The interaction of peptide with Cu2+ ion was studied. At a relative high concentration of Cu2+, the cantilever bent toward the gold side initially as the N atom of imidazole ring and carboxyl group in different peptide coordinate with Cu2+, which results in a tensile surface stress. And then the reversed deflection of microcantilever was observed, which implies that the peptide-Cu2+ complex are formed with conformation transition. In another case, i.e., at a relative low concentration Of Cu2+, only the process of conformation transition was observed due to the coordination mode can not be formed initially. The influences of pH and salt concentration of the test solution on the performance of the sensor were studied. The results show that the maximum deflection was obtained at pH 7 and the bonding Of Cu2+ to the Gly-Gly-His tripeptide was inhibited due to the formation Of CuClx2-x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to investigate the evaporation dynamics of water microdrops deposited on atomic force microscope cantilevers, which were employed as sensitive stress, mass and temperature sensors with high time resolution. The technique has some advantages with respect to video-microscope imaging and ultra-precision weighting with electronic microbalances or quartz crystal microbalances, since it allows to measure more drop parameters simultaneously for smaller drop sizes. On hydrophobic surfaces a single measurement with a silicon cantilever provides data for the drop mass, contact angle and radius until very close to complete evaporation. On hydrophilic surfaces, it is as well possible to measure drop mass and inclination of the cantilever. The technique further allows to detect differences between water microdrops evaporating from clean hydrophilic and hydrophobic surfaces. On hydrophilic surfaces the cantilever inclination is negative at the end of the evaporation process. Negative inclination mostly occurs when drops are pinned. This effect can not be detected with any of the other well-established methods. The evidence arises that on the hydrophilic surface a thin water film forms, while this is not the case for the hydrophobic surface. Metal coated cantilevers can be used as thermometers, and allow to precisely measure the temperature of an evaporating microdrop. This can be relevant for further applications of cantilevers as calorimetric sensors for chemical reactions taking place in drops on their surface. The applicability of Young’s equation was verified for microdrops. It was shown that Young’s equation can not be applied to microscopic drops due to their fast evaporation. A study on evaporation of microdrops in saturated vapor atmosphere was performed to estimate evaporation times and compare them with a theory developed, which relates the initial drop volume with the overall evaporation time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultraviolet-ozone treatment is used as a standard surface cleaning procedure for removal of molecular organic contamination from analytical and sensing devices. Here, it is applied for injection-molded polymer microcantilevers before characterization and sensing experiments. This article examines the effects of the surface cleaning process using commercial equipment, in particular on the performance and mechanical properties of the cantilevers. It can be shown that the first chemical aging process essentially consist of the cross linking of the polymer chains together with a physical aging of the material. For longer exposure, the expected thermo-oxidative formation of carbonyl groups sets in and an exposure dependent chemical degradation can be detected. A process time of 20 min was found suitable as a trade-off between cleaning and stability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El gran crecimiento de los sistemas MEMS (Micro Electro Mechanical Systems) así como su presencia en la mayoría de los dispositivos que usamos diariamente despertó nuestro interés. Paralelamente, la tecnología CMOS (Complementary Metal Oxide Semiconductor) es la tecnología más utilizada para la fabricación de circuitos integrados. Además de ventajas relacionadas con el funcionamiento electrónico del dispositivo final, la integración de sistemas MEMS en la tecnología CMOS reduce significantemente los costes de fabricación. Algunos de los dispositivos MEMS con mayor variedad de aplicaciones son los microflejes. Estos dispositivos pueden ser utilizados para la extracción de energía, en microscopios de fuerza atómica o en sensores, como por ejemplo, para biodetección. Los materiales piezoeléctricos más comúnmente utilizados en aplicaciones MEMS se sintetizan a altas temperaturas y por lo tanto no son compatibles con la tecnología CMOS. En nuestro caso hemos usado nitruro de alumino (AlN), que se deposita a temperatura ambiente y es compatible con la tecnología CMOS. Además, es biocompatible, y por tanto podría formar parte de un dispositivo que actúe como biosensor. A lo largo de esta tesis hemos prestado especial atención en desarrollar un proceso de fabricación rápido, reproducible y de bajo coste. Para ello, todos los pasos de fabricación han sido minuciosamente optimizados. Los parámetros de sputtering para depositar el AlN, las distintas técnicas y recetas de ataque, los materiales que actúan como electrodos o las capas sacrificiales para liberar los flejes son algunos de los factores clave estudiados en este trabajo. Una vez que la fabricación de los microflejes de AlN ha sido optimizada, fueron medidos para caracterizar sus propiedades piezoeléctricas y finalmente verificar positivamente su viabilidad como dispositivos piezoeléctricos. ABSTRACT The huge growth of MEMS (Micro Electro Mechanical Systems) as well as their presence in most of our daily used devices aroused our interest on them. At the same time, CMOS (Complementary Metal Oxide Semiconductor) technology is the most popular technology for integrated circuits. In addition to advantages related with the electronics operation of the final device, the integration of MEMS with CMOS technology reduces the manufacturing costs significantly. Some of the MEMS devices with a wider variety of applications are the microcantilevers. These devices can be used for energy harvesting, in an atomic force microscopes or as sensors, as for example, for biodetection. Most of the piezoelectric materials used for these MEMS applications are synthesized at high temperature and consequently are not compatible with CMOS technology. In our case we have used aluminum nitride (AlN), which is deposited at room temperature and hence fully compatible with CMOS technology. Otherwise, it is biocompatible and and can be used to compose a biosensing device. During this thesis work we have specially focused our attention in developing a high throughput, reproducible and low cost fabrication process. All the manufacturing process steps of have been thoroughly optimized in order to achieve this goal. Sputtering parameters to synthesize AlN, different techniques and etching recipes, electrode material and sacrificial layers are some of the key factors studied in this work to develop the manufacturing process. Once the AlN microcantilevers fabrication was optimized, they were measured to characterize their piezoelectric properties and to successfully check their viability as piezoelectric devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improvements to the current state of the art in microfabricated cantilevers are investigated in order to realize enhanced functionality and increased versatility for use in ultrafast electrophoretic molecular sorting and delivery. Design rationale and fabrication process flow are described for six types of electro-thermal microcantilevers. Devices have been tailored for the process of separating mixtures of heterogeneous molecules into discrete detectable bands based on electrophoretic mobility, and delivering them to a conductive substrate using electric fields. Four device types include integrated heating elements capable of warming samples to catalyze reactions or cleaning the device for reuse. Similar devices have been shown to be capable of targeting temperatures between ambient conditions and the melting point of silicon, to within 0.1˚C precision or better. All microcantilevers types are equipped with a highly doped conductive silicon tip capable of interacting with a conductive substrate to deliver molecules under the presence of an electric field. Devices are equipped with additional electrodes to aid in sorting molecules on the surface of the probe end. Two designs contain two legs and one additional sorting electrode while four designs contain three legs and have two sorting electrodes. Devices having two sorting electrodes are designed to be capable of sorting three or more molecular species, a distinctive advancement in the state of the art. A detailed process flow of the fabrication process for all six electro-thermal cantilever designs are explained in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A post-complementary metal oxide semiconductor (CMOS) compatible microfabrication process of piezoelectric cantilevers has been developed. The fabrication process is suitable for standard silicon technology and provides low-cost and high-throughput manufacturing. This work reports design, fabrication and characterization of piezoelectric cantilevers based on aluminum nitride (AlN) thin films synthesized at room temperature. The proposed microcantilever system is a sandwich structure composed of chromium (Cr) electrodes and a sputtered AlN film. The key issue for cantilever fabrication is the growth at room temperature of the AlN layer by reactive sputtering, making possible the innovative compatibility of piezoelectric MEMS devices with CMOS circuits already processed. AlN and Cr have been etched by inductively coupled plasma (ICP) dry etching using a BCl3–Cl2–Ar plasma chemistry. As part of the novelty of the post-CMOS micromachining process presented here, a silicon Si (1 0 0) wafer has been used as substrate as well as the sacrificial layer used to release the microcantilevers. In order to achieve this, the Si surface underneath the structure has been wet etched using an HNA (hydrofluoric acid + nitric acid + acetic acid) based solution. X-ray diffraction (XRD) characterization indicated the high crystalline quality of the AlN film. An atomic force microscope (AFM) has been used to determine the Cr electrode surface roughness. The morphology of the fabricated devices has been studied by scanning electron microscope (SEM). The cantilevers have been piezoelectrically actuated and their out-of-plane vibration modes were detected by vibrometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to simulate and optically characterize the piezoelectric performance of complementary metal oxide semiconductor (CMOS) compatible microcantilevers based on aluminium nitride (AlN) and manufactured at room temperature. This study should facilitate the integration of piezoelectric micro-electro-mechanical systems (MEMS) such as microcantilevers, in CMOS technology. Besides compatibility with standard integrated circuit manufacturing procedures, low temperature processing also translates into higher throughput and, as a consequence, lower manufacturing costs. Thus, the use of the piezoelectric properties of AlN manufactured by reactive sputtering at room temperature is an important step towards the integration of this type of devices within future CMOS technology standards. To assess the reliability of our fabrication process, we have manufactured arrays of free-standing microcantilever beams of variable dimension and studied their piezoelectric performance. The characterization of the first out-of-plane modes of AlN-actuated piezoelectric microcantilevers has been carried out using two optical techniques: laser Doppler vibrometry (LDV) and white light interferometry (WLI). In order to actuate the cantilevers, a periodic chirp signal in certain frequency ranges was applied between the device electrodes. The nature of the different vibration modes detected has been studied and compared with that obtained by a finite element model based simulation (COMSOL Multiphysics), showing flexural as well as torsional modes. The correspondence between theoretical and experimental data is reasonably good, probing the viability of this high throughput and CMOS compatible fabrication process. To complete the study, X-ray diffraction as well as d33 piezoelectric coefficient measurements were also carried out.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metal-based piezoresistive sensing devices could find a much wider applicability if their sensitivity to mechanical strain could be substantially improved. Here, we report a simple method to enhance the strain sensitivity of metal films by over two orders of magnitude and demonstrate it on specially designed microcantilevers. By locally inhomogenizing thin gold films using controlled electromigration, we have achieved a logarithmic divergence in the strain sensitivity with progressive microstructural modification. The enhancement in strain sensitivity could be explained using non-universal tunneling-percolation transport. We find that the Johnson noise limited signal-to-noise ratio is an order of magnitude better than silicon piezoresistors. This method creates a robust platform for engineering low resistance, high gauge factor metallic piezoresistors that may have profound impact on micro and nanoscale self-sensing technology. (C) 2012 American Institute of Physics. http://dx.doi.org/10.1063/1.4761817]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physical forces generated by cells drive morphologic changes during development and can feedback to regulate cellular phenotypes. Because these phenomena typically occur within a 3-dimensional (3D) matrix in vivo, we used microelectromechanical systems (MEMS) technology to generate arrays of microtissues consisting of cells encapsulated within 3D micropatterned matrices. Microcantilevers were used to simultaneously constrain the remodeling of a collagen gel and to report forces generated during this process. By concurrently measuring forces and observing matrix remodeling at cellular length scales, we report an initial correlation and later decoupling between cellular contractile forces and changes in tissue morphology. Independently varying the mechanical stiffness of the cantilevers and collagen matrix revealed that cellular forces increased with boundary or matrix rigidity whereas levels of cytoskeletal and extracellular matrix (ECM) proteins correlated with levels of mechanical stress. By mapping these relationships between cellular and matrix mechanics, cellular forces, and protein expression onto a bio-chemo-mechanical model of microtissue contractility, we demonstrate how intratissue gradients of mechanical stress can emerge from collective cellular contractility and finally, how such gradients can be used to engineer protein composition and organization within a 3D tissue. Together, these findings highlight a complex and dynamic relationship between cellular forces, ECM remodeling, and cellular phenotype and describe a system to study and apply this relationship within engineered 3D microtissues.