983 resultados para Metaphors on Vision


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background To determine the impact of cataract surgery on vision-related quality of life (VRQOL) and examine the association between objective visual measures and change in VRQOL after surgery among bilateral cataract patients in Ho Chi Minh City, Vietnam. Methods A cohort of older patients with bilateral cataract was assessed one week before and one to three months after first eye or both eye cataract surgery. Visual measures including visual acuity, contrast sensitivity and stereopsis were obtained. Vision-related quality of life was assessed using the NEI VFQ-25. Descriptive analyses and a generalized linear estimating equation (GEE) analysis were undertaken to measure change in VRQOL after surgery. Results Four hundred and thirteen patients were assessed before cataract surgery and 247 completed the follow-up assessment one to three months after first or both eye cataract surgery. Overall, VRQOL significantly improved after cataract surgery (p < 0.001) particularly after both eye surgeries. Binocular contrast sensitivity (p < 0.001) and stereopsis (p < 0.001) were also associated with change in VRQOL after cataract surgery. Visual acuity was not associated with VRQOL. Conclusions Cataract surgery significantly improved VRQOL among bilateral cataract patients in Vietnam. Contrast sensitivity as well as stereopsis, rather than visual acuity significantly affected VRQOL after cataract surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the past several decades there has been a sharp increase in the number of studies focused on the relationship between vision and driving. The intensified attention to this topic has most likely been stimulated by the lack of an evidence basis for determining vision standards for driving licensure and a poor understanding about how vision impairment impacts driver safety and performance. Clinicians depend on the literature on vision and driving to advise visually impaired patients appropriately about driving fitness. Policy makers also depend on the scientific literature in order to develop guidelines that are evidence-based and are thus fair to persons who are visually impaired. Thus it is important for clinicians and policy makers alike to understand how various study designs and measurement methods should be interpreted so that the conclusions and recommendations they make are not overly broad, too narrowly constrained, or even misguided. We offer a methodological framework to guide interpretations of studies on vision and driving that can also serve as a heuristic for researchers in the area. Here, we discuss research designs and general measurement methods for the study of vision as they relate to driver safety, driver performance, and driver-centered (self-reported) outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To examine internal consistency, refine the response scale, and obtain a linear scoring system for the visual function instrument, the Daily Living Tasks Dependent on Vision (DLTV). METHODS. Data were available from 186 participants with a clinical diagnosis of AMD who completed the 22-item DLTV (DLTV-22) according to four-point ordinal response scale. An independent group of 386 participants with AMD were administered a reduced version of the DLTV with 11 items (DLTV-11), according to a five-point response scale. Rasch analysis was performed on both datasets and used to generate item statistics for measure order, response odds ratios per item and per person, and infit and outfit mean square statistics. The Rasch output from the DLTV-22 was examined to identify redundant items and for factorial validity and person item measure separation reliabilities. RESULTS. The average rating for the DLTV-22 changed monotonically with the magnitude of the latent person trait. The expected versus observed average measures were extremely close, with step calibrations evenly separated for the four-point ordinal scale. In the case of the DLTV-11, step calibrations were not as evenly separated, suggesting that the five-point scale should be reduced to either a four- or three-point scale. Five items in the DLTV-22 were removed, and all 17 remaining items had good infit and outfit mean squares. PCA with residuals from Rasch analysis identified two domains containing 7 and 10 items each. The domains had high person separation reliabilities (0.86 and 0.77 for domains 1 and 2, respectively) and item measure reliabilities (0.99 and 0.98 for domains 1 and 2, respectively). CONCLUSIONS. With the improved internal consistency, establishment of the accuracy and precision of the rating scale for the DLTV and the establishment of a valid domain structure we believe that it constitutes a useful instrument for assessing visual function in older adults with age-related macular degeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The recently completed Chinese "Million Cataract Surgeries Program" (MCSP) is among the largest such campaigns ever, providing 1.05 million operations. We report MCSP outcomes for the first time, in Jiangxi, the province with the greatest program output. Methods: Ten county hospitals participating in MCSP were selected in Jiangxi (range of gross domestic product per capita US$743-2998). Each hospital sought to enroll 75 consecutive MCSP patients aged ≥50 years. Data recorded included type of cataract procedure, bilateral uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), and refractive error pre- and ≥50 days postoperatively. Results: Among 715 patients (mean age 72.3±9.1 years, 55.5% female), preoperative UCVA was <3/60 (legally blind) bilaterally in 13.3% and unilaterally in the operated eye in 50.9%. No subjects had UCVA >6/18 preoperatively. Small incision cataract surgery was performed in 92.3% patients. Among 662 patients (92.6%) completing follow-up was ≥ 40 days after surgery, BCVA was ≥6/18 in 80.1%, UCVA was ≥6/18 in 57.1% and UCVA was <3/60 in 2.1%. Older age (p<0.001), female sex (p=0.04), worse refractive error (p=0.02) and presence of intra- (p=0.002) and postoperative surgical complications (p<0.001), were independently associated with worse postoperative UCVA. Based on these results, the MCSP cured an estimated 124,950 cases (13.3%×[100-2.1%]×1.05 million) of bilateral and 502,500 (50.9%×[100-2.1%]×1.05 million) of unilateral blindness. Conclusions: Due to relatively good outcomes and the large number of surgeries performed on blind persons, the sight-restoring impact of the MCSP was probably substantial. © Informa Healthcare USA, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To study the effect of posterior capsular opacification (PCO) on vision and visual function in patients undergoing cataract surgery in rural China, and to compare this with the effect of refractive error. METHODS: Patients undergoing cataract surgery in at least one eye by local surgeons in a rural setting between 8 August and 31 December 2005 were examined with slit lamp grading of PCO 10-14 months after surgery. Subjects with any PCO associated with best-corrected visual acuity of 6/7.5 or worse, or with grade 2+ or worse PCO without visual decrement, were offered YAG laser capsulotomy. Vision and self-reported visual function were assessed, and various demographic and clinical factors potentially associated with PCO were recorded. RESULTS: Of 313 patients operated on within the study window, 239 (76%) could be contacted by telephone; study examinations were performed on 176 (74%). Examined subjects had a mean (SD) age of 69.4 (10.5) years, 116 (67%) were female, and 149 (86%) had been blind (presenting visual acuity < or = 6/60) in the operated eye before surgery. PCO of grade 1 or above was present in 34 of 204 operated eyes (16.7%). Those with PCO had significantly worse presenting vision (p = 0.007) but not visual function (p>0.3) than those without PCO. Women had a significantly higher prevalence of PCO (20.9%) than did men (8.6%, p<0.05). Of 19 eyes undergoing capsulotomy with best-corrected visual acuity measured the next day, 13 (68%) improved by one or more lines, and seven (37%) improved by two or more lines. Despite a higher uptake of capsulotomy (95%) as opposed to refraction (35%) in this cohort, the yield in terms of eyes with poor presenting visual acuity (< 6/18) that could be improved was higher for refraction (26% = 9/35) than for capsulotomy (9% = 3/35). CONCLUSION: The prevalence of PCO and impact on vision and visual function in this cohort was modest 1 year after surgery. However, PCO prevalence increases with time. Follow-up of this cohort is underway to determine the effectiveness of this early intervention in identifying and treating subjects who will eventually experience clinically significant PCO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM To report on an intraradicular visual test in a simulated clinical setting under different optical conditions. METHODOLOGY Miniaturized visual tests with E-optotypes (bar distance from 0.01 to 0.05 mm) were fixed inside the root canal system of an extracted maxillary molar at different locations: at the orifice, a depth of 5 mm and the apex. The tooth was mounted in a phantom head for a simulated clinical setting. Unaided vision was compared with Galilean loupes (2.5× magnification) with integrated light source and an operating microscope (6× magnification). The influence of the dentists' age within two groups was evaluated: <40 years (n = 9) and ≥40 years (n = 15). RESULTS Some younger dentists were able to identify the E-optotypes at the orifice, but otherwise, natural vision did not reveal any measurable result. With Galilean loupes, the younger dentists <40 years could see a 0.05 mm structure at the root canal orifice, in contrast to the older group ≥40 years. Only the microscope allowed the observation of structures inside the root canal, independent of age. CONCLUSION Unaided vision and Galilean loupes with an integrated light source could not provide any measurable vision inside the root canal, but younger dentists <40 years could detect with Galilean loupes a canal orifice corresponding to the tip of the smallest endodontic instruments. Dentists over 40 years of age were dependent on the microscope to inspect the root canal system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bound with other pamphlets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To examine the effect of uncorrected astigmatism in older adults. SETTING: University Vision Clinic METHOD: Twenty-one healthy presbyopes, aged 58.9±2.8 years, had astigmatism of 0.0 to -4.0 x 90?DC and -3.0DC of cylinder at 90?, 180? and 45? induced with spectacle lenses, with the mean spherical equivalent compensated to plano, in random order. Visual acuity was assessed binocularly using a computerised test chart at 95%, 50% and 10% contrast. Near acuity and reading speed were measured using standardised reading texts. Light scatter was quantified with the cQuant and driving reaction times with a computer simulator. Finally visual clarity of a mobile phone and computer screen was subjectively rated. RESULTS: Distance visual acuity decreased with increasing uncorrected astigmatic power (F=174.50, p<0.001) and was reduced at lower contrasts (F=170.77, p<0.001). Near visual acuity and reading speed also decreased with increasing uncorrected astigmatism power (p<0.001). Light scatter was not significantly affected by uncorrected astigmatism (p>0.05), but the reliability and variability of measurements decreased with increasing uncorrected astigmatic power (p<0.05). Driving simulator performance was also unaffected by uncorrected astigmatism (p>0.05), but subjective rating of clarity decreased with increasing uncorrected astigmatic power (p<0.001). Uncorrected astigmatism at 45? or 180? orientation resulted in a worse distance and near visual acuity, and subjective rated clarity than 90? orientation (p<0.05). CONCLUSION: Uncorrected astigmatism, even as low as 1.0DC, causes a significant burden on a patient’s vision. If left uncorrected, this could impact significantly on their independence, quality of life and wellbeing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To show that the limited quality of surfaces produced by one model of excimer laser systems can degrade visual performance with a polymethylmethacrylate (PMMA) model. METHODS: A range of lenses of different powers was ablated in PMMA sheets using five DOS-based Nidek EC-5000 laser systems (Nidek Technologies, Gamagori, Japan) from different clinics. Surface quality was objectively assessed using profilometry. Contrast sensitivity and visual acuity were measured through the lenses when their powers were neutralized with suitable spectacle trial lenses. RESULTS: Average surface roughness was found to increase with lens power, roughness values being higher for negative lenses than for positive lenses. Losses in visual contrast sensitivity and acuity measured in two subjects were found to follow a similar pattern. Findings are similar to those previously published with other excimer laser systems. CONCLUSIONS: Levels of surface roughness produced by some laser systems may be sufficient to degrade visual performance under some circumstances.