1000 resultados para Medio de Hoyer
Resumo:
Se comunican resultados obtenidos empleando Medio de Hoyer para el montaje de huevos de helmintos enteroparásitos, destinado a preparaciones para colecciones docentes y/o de investigación. La utilización de esta técnica en muestras fecales conteniendo huevos de A. lumbricoides, T. trichiura, Uncinaria sp., Taenia sp., Diphyllobothrium sp., H. nana, H. diminuta y F. hepática, permitió la correcta observación de ellos en lecturas iniciadas a las 24 horas y mantenidas hasta 180 días después.
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
OBJETIVO: O objetivo deste trabalho foi estudar a grandeza practical peak voltage (PPV), determinada a partir da forma de onda de tensão aplicada a tubos radiológicos, e compará-la com algumas definições de kVp para diferentes tipos de geradores: monofásico (onda completa, clínico), trifásico (seis pulsos, clínico) e potencial constante (industrial). MATERIAIS E MÉTODOS: O trabalho envolveu a comparação do PPV medido invasivamente (utilizando um divisor de tensão) com a resposta de dois medidores comerciais não invasivos, além dos valores de outras grandezas usadas para medição da tensão de pico aplicada ao tubo de raios X, e a análise da variação do PPV com a ondulação percentual da tensão (ripple). RESULTADOS: Verificou-se que a diferença entre o PPV e as definições mais comuns de tensão de pico aumenta com o ripple. Os valores de PPV variaram em até 3% e 5%, respectivamente, na comparação entre medições invasivas e não invasivas feitas com os equipamentos trifásico e monofásico. CONCLUSÃO: Os resultados demonstraram que a principal grandeza de influência que afeta o PPV é o ripple da tensão. Adicionalmente, valores de PPV obtidos com medidores não invasivos devem ser avaliados considerando que eles dependem da taxa de aquisição e da forma de onda adquirida pelo instrumento.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
OBJETIVO: Esta pesquisa tem como objetivo propor uma forma de medir a posição vertical da laringe (PVL) no pescoço, em repouso, de adultos jovens sem queixas vocais. FORMA DE ESTUDO: Estudo de coorte transversal. MATERIAL E MÉTODO: Participaram da pesquisa 68 sujeitos, faixa etária de 18 a 44 anos de idade, sendo 33 do sexo feminino e 35 do sexo masculino. Os pontos de referência utilizados para a pesquisa foram os ângulos da mandíbula direito e esquerdo (AMD e AME), o centro do arco da cartilagem cricóidea (CC) e o centro da fúrcula esternal (FE). Para a obtenção das medidas, os sujeitos foram orientados a permanecerem sentados com a cabeça em hiperextensão máxima. Os materiais utilizados foram um compasso e uma régua de 20cm. RESULTADOS: A obtenção das medidas se mostrou ser de fácil realização e não apresentou qualquer tipo de desconforto aos participantes. Houve diferença estatisticamente significante entre os sexos feminino e masculino quanto à posição vertical da laringe, sendo que as mulheres apresentaram a laringe em posição mais alta que os homens. A posição vertical da laringe foi de fácil obtenção e parece ser um parâmetro muito interessante no acompanhamento clínico intra-sujeitos.