960 resultados para Medical technology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Equity research report

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this thesis is to examine software licensing, how a software developer can benefit from it and to define specifications for licensing system of software based medical technology product. The thesis has been divided into theoretical and empirical parts. In the theoretical part the concept of software licensing and different aspects that are connected to it are examined with a help of research material. On the ground of this research, in the empirical part, a licensing system for a medical software product called iCentral is designed. The empirical part is based on interviews, questionnaire and on authors own experience gained while working for the case-company.The thesis has great practical importance for the case-company by proposing both an ideal, and more importantly, practical implementation for a licensing system of a product. Thesis shows that electronic licensing is a viable option to sell medical technology products without a need to revise existing procedures or the enterprise resource system in the case company.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Food and Drug Administration (FDA) is responsible for risk assessment and risk management in the post-market surveillance of the U.S. medical device industry. One of the FDA regulatory mechanisms, the Medical Device Reporting System (MDR) is an adverse event reporting system intended to provide the FDA with advance warning of device problems. It includes voluntary reporting for individuals, and mandatory reporting for device manufacturers. ^ In a study of alleged breast implant safety problems, this research examines the organizational processes by which the FDA gathers data on adverse events and uses adverse event reporting systems to assess and manage risk. The research reviews the literature on problem recognition, risk perception, and organizational learning to understand the influence highly publicized events may have on adverse event reporting. Understanding the influence of an environmental factor, such as publicity, on adverse event reporting can provide insight into the question of whether the FDA's adverse event reporting system operates as an early warning system for medical device problems. ^ The research focuses on two main questions. The first question addresses the relationship between publicity and the voluntary and mandatory reporting of adverse events. The second question examines whether government agencies make use of these adverse event reports. ^ Using quantitative and qualitative methods, a longitudinal study was conducted of the number and content of adverse event reports regarding breast implants filed with the FDA's medical device reporting system during 1985–1991. To assess variation in publicity over time, the print media were analyzed to identify articles related to breast implant failures. ^ The exploratory findings suggest that an increase in media activity is related to an increase in voluntary reporting, especially following periods of intense media coverage of the FDA. However, a similar relationship was not found between media activity and manufacturers' mandatory adverse event reporting. A review of government committee and agency reports on the FDA published during 1976–1996 produced little evidence to suggest that publicity or MDR information contributed to problem recognition, agenda setting, or the formulation of policy recommendations. ^ The research findings suggest that the reporting of breast implant problems to FDA may reflect the perceptions and concerns of the reporting groups, a barometer of the volume and content of media attention. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"OTA-H-262"--P. [4] of cover.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"OTA-TM-H-17"--P. [4] of cover.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The epidemiological methods have become useful tools for the assessment of the effectiveness and safety of health care technologies. The experimental methods, namely the randomized controlled trials (RCT), give the best evidence of the effect of a technology. However, the ethical issues and the very nature of the intervention under study sometimes make it difficult to carry out an RCT. Therefore, quasi-experimental and non-experimental study designs are also applied. The critical issues concerning these designs are discussed. The results of evaluative studies are of importance for decision-makers in health policy. The measurements of the impact of a medical technology should go beyond a statement of its effectiveness, because the essential outcome of an intervention or programme is the health status and quality of life of the individuals and populations concerned.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The assessment of medical technologies has to answer several questions ranging from safety and effectiveness to complex economical, social, and health policy issues. The type of data needed to carry out such evaluation depends on the specific questions to be answered, as well as on the stage of development of a technology. Basically two types of data may be distinguished: (a) general demographic, administrative, or financial data which has been collected not specifically for technology assessment; (b) the data collected with respect either to a specific technology or to a disease or medical problem. On the basis of a pilot inquiry in Europe and bibliographic research, the following categories of type (b) data bases have been identified: registries, clinical data bases, banks of factual and bibliographic knowledge, and expert systems. Examples of each category are discussed briefly. The following aims for further research and practical goals are proposed: criteria for the minimal data set required, improvement to the registries and clinical data banks, and development of an international clearinghouse to enhance information diffusion on both existing data bases and available reports on medical technology assessments.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this thesis, I examine the diffusion process for a complex medical technology, the PET scanner, in two different health care systems, one of which is more market-oriented (Switzerland) and the other more centrally managed by a public agency (Quebec). The research draws on institutional and socio-political theories of the diffusion of innovations to examine how institutional contexts affect processes of diffusion. I find that diffusion proceeds more rapidly in Switzerland than in Quebec, but that processes in both jurisdictions are characterized by intense struggles among providers and between providers and public agencies. I show that the institutional environment influences these processes by determining the patterns of material resources and authority available to actors in their struggles to strategically control the technology, and by constituting the discursive resources or institutional logics on which actors may legitimately draw in their struggles to give meaning to the technology in line with their interests and values. This thesis illustrates how institutional structures and meanings manifest themselves in the context of specific decisions within an organizational field, and reveals the ways in which governance structures may be contested and realigned when they conflict with interests that are legitimized by dominant institutional logics. It is argued that this form of contestation and readjustment at the margins constitutes one mechanism by which institutional frameworks are tested, stretched and reproduced or redefined.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The data indispensable for carrying out the comprehensive, multi-faceted process of medical technology assessment (MTA) should be collected from a variety of sources. The authors distinguish between type "A" general data, useful for assessment but collected without this specific aim, and type "B" data. Registries of health care procedures or of diseases, as well as clinical data bases are quoted as examples of type "B" data, specifically relating to MTA. Since demographic methods are of importance for the evaluation of long-term effects of medical technologies, examples of sources of type "A" data are presented. Their significance for health policy making is discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives. To investigate procedural gender equity by assessing predisposing, enabling and need predictors of gender differences in annual medical expenditures and utilization among hypertensive individuals in the U.S. Also, to estimate and compare lifetime medical expenditures among hypertensive men and women in the U.S. ^ Data source. 2001-2004 the Medical Expenditure Panel Survey (MEPS);1986-2000 National Health Interview Survey (NHIS) and National Health Interview Survey linked to mortality in the National Death Index through 2002 (2002 NHIS-NDI). ^ Study design. We estimated total medical expenditure using four equations regression model, specific medical expenditures using two equations regression model and utilization using negative binomial regression model. Procedural equity was assessed by applying the Aday et al. theoretical framework. Expenditures were estimated in 2004 dollars. We estimated hypertension-attributable medical expenditure and utilization among men and women. ^ To estimate lifetime expenditures from ages 20 to 85+, we estimated medical expenditures with cross-sectional data and survival with prospective data. The four equations regression model were used to estimate average annual medical expenditures defined as sum of inpatient stay, emergency room visits, outpatient visits, office based visits, and prescription drugs expenditures. Life tables were used to estimate the distribution of life time medical expenditures for hypertensive men and women at different age and factors such as disease incidence, medical technology and health care cost were assumed to be fixed. Both total and hypertension attributable expenditures among men and women were estimated. ^ Data collection. We used the 2001-2004 MEPS household component and medical condition files; the NHIS person and condition files from 1986-1996 and 1997-2000 sample adult files were used; and the 1986-2000 NHIS that were linked to mortality in the 2002 NHIS-NDI. ^ Principal findings. Hypertensive men had significantly less utilization for most measures after controlling predisposing, enabling and need factors than hypertensive women. Similarly, hypertensive men had less prescription drug (-9.3%), office based (-7.2%) and total medical (-4.5%) expenditures than hypertensive women. However, men had more hypertension-attributable medical expenditures and utilization than women. ^ Expected total lifetime expenditure for average life table individuals at age 20, was $188,300 for hypertensive men and $254,910 for hypertensive women. But the lifetime expenditure that could be attributed to hypertension was $88,033 for men and $40,960 for women. ^ Conclusion. Hypertensive women had more utilization and expenditure for most measures than hypertensive men, possibly indicating procedural inequity. However, relatively higher hypertension-attributable health care of men shows more utilization of resources to treat hypertension related diseases among men than women. Similar results were reported in lifetime analyses.^ Key words: gender, medical expenditures, utilization, hypertension-attributable, lifetime expenditure ^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.