990 resultados para Measurement procedure


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper, the results of the time dispersion parameters obtained from a set of channel measurements conducted in various environments that are typical of multiuser Infostation application scenarios are presented. The measurement procedure takes into account the practical scenarios typical of the positions and movements of the users in the particular Infostation network. To provide one with the knowledge of how much data can be downloaded by users over a given time and mobile speed, data transfer analysis for multiband orthogonal frequency division multiplexing (MB-OFDM) is presented. As expected, the rough estimate of simultaneous data transfer in a multiuser Infostation scenario indicates dependency of the percentage of download on the data size, number and speed of the users, and the elapse time.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate high-definition and conventional oscillometry in comparison with direct blood pressure measurements in anaesthetised dogs. METHODS: Eight simultaneous readings for systolic, diastolic and mean pressure were obtained directly and with each of two devices in nine anaesthetised dogs. Measurement procedure and validation were based on the 2007 ACVIM guidelines. RESULTS: Sixty-three simultaneous readings were evaluated for each device and direct measurements. The mean differences (bias) to direct values were within 10 mmHg for both devices although bias for systolic and diastolic blood pressures was higher for Memodiagnostic. The standard deviations of differences (precision) were within 15 mmHg for Dinamap but exceeded for Memodiagnostic. Correlation coefficients were higher for Dinamap than Memodiagnostic but both failed to reach a correlation of 0.9. Over 50% of values lay within 10 mmHg of direct measures for both devices, but this percentage was greater for Dinamap than Memodiagnostic. Over 80% of values lay within 20 mmHg of direct measures for Dinamap but not for Memodiagnostic. CLINICAL SIGNIFICANCE: Both devices failed to meet ACVIM guideline validation. However, Dinamap only failed with regards to correlation. Memodiagnostic failed on several requirements, and based on poor correlation, accuracy and precision, this device cannot be currently recommended for dogs under anaesthesia.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Considering the measurement procedures recommended by the ICNIRP, this communication is a proposal for a measurement procedure based in the maximum peak values of equivalent plane wave power density. This procedure has been included in a project being developed in Leganés, Spain. The project plans to deploy a real time monitoring system for RF to provide the city with a useful tool to adapt the environmental EM conditions to the new regulations approved. A first stage consisting of 105 measurement points has been finished and all the values are under the threshold of the regulation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We show how the measurement induced model of quantum computation proposed by Raussendorf and Briegel ( 2001, Phys. Rev. Letts., 86, 5188) can be adapted to a nonlinear optical interaction. This optical implementation requires a Kerr nonlinearity, a single photon source, a single photon detector and fast feed forward. Although nondeterministic optical quantum information proposals such as that suggested by KLM ( 2001, Nature, 409, 46) do not require a Kerr nonlinearity they do require complex reconfigurable optical networks. The proposal in this paper has the benefit of a single static optical layout with fixed device parameters, where the algorithm is defined by the final measurement procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Motor vehicles are a major source of gaseous and particulate matter pollution in urban areas, particularly of ultrafine sized particles (diameters < 0.1 µm). Exposure to particulate matter has been found to be associated with serious health effects, including respiratory and cardiovascular disease, and mortality. Particle emissions generated by motor vehicles span a very broad size range (from around 0.003-10 µm) and are measured as different subsets of particle mass concentrations or particle number count. However, there exist scientific challenges in analysing and interpreting the large data sets on motor vehicle emission factors, and no understanding is available of the application of different particle metrics as a basis for air quality regulation. To date a comprehensive inventory covering the broad size range of particles emitted by motor vehicles, and which includes particle number, does not exist anywhere in the world. This thesis covers research related to four important and interrelated aspects pertaining to particulate matter generated by motor vehicle fleets. These include the derivation of suitable particle emission factors for use in transport modelling and health impact assessments; quantification of motor vehicle particle emission inventories; investigation of the particle characteristic modality within particle size distributions as a potential for developing air quality regulation; and review and synthesis of current knowledge on ultrafine particles as it relates to motor vehicles; and the application of these aspects to the quantification, control and management of motor vehicle particle emissions. In order to quantify emissions in terms of a comprehensive inventory, which covers the full size range of particles emitted by motor vehicle fleets, it was necessary to derive a suitable set of particle emission factors for different vehicle and road type combinations for particle number, particle volume, PM1, PM2.5 and PM1 (mass concentration of particles with aerodynamic diameters < 1 µm, < 2.5 µm and < 10 µm respectively). The very large data set of emission factors analysed in this study were sourced from measurement studies conducted in developed countries, and hence the derived set of emission factors are suitable for preparing inventories in other urban regions of the developed world. These emission factors are particularly useful for regions with a lack of measurement data to derive emission factors, or where experimental data are available but are of insufficient scope. The comprehensive particle emissions inventory presented in this thesis is the first published inventory of tailpipe particle emissions prepared for a motor vehicle fleet, and included the quantification of particle emissions covering the full size range of particles emitted by vehicles, based on measurement data. The inventory quantified particle emissions measured in terms of particle number and different particle mass size fractions. It was developed for the urban South-East Queensland fleet in Australia, and included testing the particle emission implications of future scenarios for different passenger and freight travel demand. The thesis also presents evidence of the usefulness of examining modality within particle size distributions as a basis for developing air quality regulations; and finds evidence to support the relevance of introducing a new PM1 mass ambient air quality standard for the majority of environments worldwide. The study found that a combination of PM1 and PM10 standards are likely to be a more discerning and suitable set of ambient air quality standards for controlling particles emitted from combustion and mechanically-generated sources, such as motor vehicles, than the current mass standards of PM2.5 and PM10. The study also reviewed and synthesized existing knowledge on ultrafine particles, with a specific focus on those originating from motor vehicles. It found that motor vehicles are significant contributors to both air pollution and ultrafine particles in urban areas, and that a standardized measurement procedure is not currently available for ultrafine particles. The review found discrepancies exist between outcomes of instrumentation used to measure ultrafine particles; that few data is available on ultrafine particle chemistry and composition, long term monitoring; characterization of their spatial and temporal distribution in urban areas; and that no inventories for particle number are available for motor vehicle fleets. This knowledge is critical for epidemiological studies and exposure-response assessment. Conclusions from this review included the recommendation that ultrafine particles in populated urban areas be considered a likely target for future air quality regulation based on particle number, due to their potential impacts on the environment. The research in this PhD thesis successfully integrated the elements needed to quantify and manage motor vehicle fleet emissions, and its novelty relates to the combining of expertise from two distinctly separate disciplines - from aerosol science and transport modelling. The new knowledge and concepts developed in this PhD research provide never before available data and methods which can be used to develop comprehensive, size-resolved inventories of motor vehicle particle emissions, and air quality regulations to control particle emissions to protect the health and well-being of current and future generations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new fibre-optic sensor, based on the speckle phenomenon, for the measurement of current is described. The technique has the advantages of simplicity and sensitivity, but requires a two-step measurement procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report an experimental study of recently formulated entropic Leggett-Garg inequality (ELGI) by Usha Devi et al. Phys. Rev. A 87, 052103 (2013)]. This inequality places a bound on the statistical measurement outcomes of dynamical observables describing a macrorealistic system. Such a bound is not necessarily obeyed by quantum systems, and therefore provides an important way to distinguish quantumness from classical behavior. Here we study ELGI using a two-qubit nuclear magnetic resonance system. To perform the noninvasive measurements required for the ELGI study, we prepare the system qubit in a maximally mixed state as well as use the ``ideal negative result measurement'' procedure with the help of an ancilla qubit. The experimental results show a clear violation of ELGI by over four standard deviations. These results agree with the predictions of quantum theory. The violation of ELGI is attributed to the fact that certain joint probabilities are not legitimate in the quantum scenario, in the sense they do not reproduce all the marginal probabilities. Using a three-qubit system, we also demonstrate that three-time joint probabilities do not reproduce certain two-time marginal probabilities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This technical memorandum reports on the noise measurement results performed on MBARI's Ventana ROV. The measurement procedure and the instrumentation for this experiment are also described. This report is organized as follows: Section 1 provides some introductory information. Section 2 describes the experiment and the instrumentation. Section 3 presents the results. Section 4 contains some concluding remarks. (PDF contains 16 pages.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As many as 20-70% of patients undergoing breast conserving surgery require repeat surgeries due to a close or positive surgical margin diagnosed post-operatively [1]. Currently there are no widely accepted tools for intra-operative margin assessment which is a significant unmet clinical need. Our group has developed a first-generation optical visible spectral imaging platform to image the molecular composition of breast tumor margins and has tested it clinically in 48 patients in a previously published study [2]. The goal of this paper is to report on the performance metrics of the system and compare it to clinical criteria for intra-operative tumor margin assessment. The system was found to have an average signal to noise ratio (SNR) >100 and <15% error in the extraction of optical properties indicating that there is sufficient SNR to leverage the differences in optical properties between negative and close/positive margins. The probe had a sensing depth of 0.5-2.2 mm over the wavelength range of 450-600 nm which is consistent with the pathologic criterion for clear margins of 0-2 mm. There was <1% cross-talk between adjacent channels of the multi-channel probe which shows that multiple sites can be measured simultaneously with negligible cross-talk between adjacent sites. Lastly, the system and measurement procedure were found to be reproducible when evaluated with repeated measures, with a low coefficient of variation (<0.11). The only aspect of the system not optimized for intra-operative use was the imaging time. The manuscript includes a discussion of how the speed of the system can be improved to work within the time constraints of an intra-operative setting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The work described here is part of a research program aiming to increase the sensitivity to disease detection using Doppler ultrasound by reducing the effects to the measurement procedure on the estimation of blood velocity and detection of flow disturbance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die vorliegende Arbeit berichtet über ein neuartiges, kombiniertes Messverfahren zur gleichzeitigen Erfassung von Form und Material einer glänzenden Probenoberfläche. Die Materialerkennung erfolgt über die polarisationsoptische Brechzahlbestimmung im Messpunkt mit Mikroellipsometrie. Die Mikroellipsometrie ist ein fokussierendes Ellipsometer, das aus der Polarisationsänderung, bedingt durch die Wechselwirkung Licht – Materie, die materialcharakteristische komplexe Brechzahl eines reflektierenden Materials ermitteln kann. Bei der fokussierenden Ellipsometrie ist die Anordnung der fokussierenden Optiken von Bedeutung. Die hier vorgestellte ellipsometerexterne Fokussierung vermeidet Messfehler durch optische Anisotropien und ermöglicht die multispektrale ellipsometrische Messung. Für die ellipsometrische Brechzahlbestimmung ist zwingend die Kenntnis des Einfallswinkels des Messstrahls und die räumliche Orientierung der Oberflächenneigung zum Koordinatensystem des Ellipsometers notwendig. Die Oberflächenneigung wird mit einem Deflektometer ermittelt, das speziell für den Einsatz in Kombination mit der Ellipsometrie entwickelt wurde. Aus der lokalen Oberflächenneigung kann die Topographie einer Probe rekonstruiert werden. Der Einfallswinkel ist ebenfalls aus den Oberflächenneigungen ableitbar. Die Arbeit stellt die Systemtheorie der beiden kombinierten Messverfahren vor, außerdem werden Beiträge zu Messunsicherheiten diskutiert. Der experimentelle Teil der Arbeit beinhaltet die separate Untersuchung zur Leistungsfähigkeit der beiden zu kombinierenden Messverfahren. Die experimentellen Ergebnisse erlauben die Schlussfolgerung, dass ein Mikro-Deflexions-Ellipsometer erfolgreich realisierbar ist.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT: The present work uses multivariate statistical analysis as a form of establishing the main sources of error in the Quantitative Phase Analysis (QPA) using the Rietveld method. The quantitative determination of crystalline phases using x ray powder diffraction is a complex measurement process whose results are influenced by several factors. Ternary mixtures of Al2O3, MgO and NiO were prepared under controlled conditions and the diffractions were obtained using the Bragg-Brentano geometric arrangement. It was possible to establish four sources of critical variations: the experimental absorption and the scale factor of NiO, which is the phase with the greatest linear absorption coefficient of the ternary mixture; the instrumental characteristics represented by mechanical errors of the goniometer and sample displacement; the other two phases (Al2O3 and MgO); and the temperature and relative humidity of the air in the laboratory. The error sources excessively impair the QPA with the Rietveld method. Therefore it becomes necessary to control them during the measurement procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diese Arbeit untersucht die longitudinale und transversaleStrahldynamik am Mainzer Mikrotron MAMI. Die gemessenen Abbildungseigenschaften werden mit den Design-Rechnungen verglichen. Dadurch konnte die Strahlqualitaet von MAMI B und das Design der neuen HDSM Mikrotronstufe verbessert werden. Es wurde eine Stoerungsrechnung formuliert, um die 6-DAbbildungsmatrix entlang der Beschleunigungsstrecke zu berechnen. Ausgehend von der linearisierten Hamilton Funktion wird die Transfermatrix M in eine unendliche Summe ueber Matrizen M(n) zerlegt, die jeweils eine n-fache Wechselwirkung des Strahls mit dem Quadrupolanteil des Fuehrungsfeldes darstellen. Dank des tieferen Einblicks in die Auswirkung von Feldfehlern konnte damit das Mikrotron-Modell leicht an die gemessenen Transfermatrizen angepasst werden. Ferner wurde die Identifizierung und Korrektur anti-symmetrischer Feldfehler in den Mikrotron-Dipolen untersucht. Es wurde ein Messverfahren entwickelt, um kleine Feldkomponenten in der Bahnebene von der Groessenordnung 10E-3 zu erkennen. Das vorgeschlagene Verfahren wurde mit Hilfe des Simulationsprogramms TOSCA ausgetestet. Schliesslich wurde die Stabilitaet der Longitudinaloptik verbessert. Dadurch konnte eine hochpraezise Energiestabi-lisierung verwirklicht werden. Bei 855 MeV Strahlenergie wird eine Stabilitaet von etwa 10E-6 erreicht.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die vorliegende Dissertation beschreibt die Entwicklung, den Aufbau und die Erprobung eines neuartigen lasermassenspektrometrischen Nachweises des Ultraspurenisotops 236U. Das Nuklid 236U wird vorwiegend in Kernreaktoren durch Neutroneneinfang aus 235U gebildet und dient damit als Schlüsselisotop zur Unterscheidung anthropogenen Urans von natürlichem Uran-Vorkommen. Mit seinem Nachweis wird die Untersuchung der Migration von Kernbrennstoff in der Umwelt und die Beantwortung kritischer Fragen in der nuklearen Forensik ermöglicht. Im Rahmen dieser Arbeit wurde das Verfahren der hochauflösenden Resonanzionisations-Massenspektrometrie auf die Anforderungen des selektiven Nachweises von Uran-Isotopen angepasst. Wesentliche Schritte waren hierbei die Untersuchung einer effizienten Atomisation von Uran-Proben, die Identifikation atomarer und autoionisierender Zustände für eine resonante Anregungsleiter, die vollständige Spezifikation der Anregungsleiter für alle Uran-Isotope und schließlich die Umsetzung der Erkenntnisse in ein analytisches Messverfahren. Die optische Selektivität des Verfahrens konnte durch Dichtematrixrechnungen zu ca. 14 Größenordnungen abgeschätzt werden; die Nachweisgrenze des Verfahrens für das Isotopenverhältnis 236U / 238U ist dabei gegenwärtig durch Untergrund begrenzt und beträgt ca. 3 · 10−8. Mit diesen Spezifikationen konnte die Linearität und Präzision des Nachweisverfahrens über einen dynamischen Bereich von vier Größenordnungen nachgewiesen werden.