949 resultados para Material particulado atmosférico (MPA)
Resumo:
Trace element concentrations were measured in atmospheric particulate matter collected in 2009 and 2010, in a Brazilian region influenced by pre-harvest burning of sugar cane crops. For coarse particles, high concentrations of Al, Fe, K and Ca suggested that re-suspended soil dust was the main source of aerosol trace elements, subsequently confirmed by XRD analysis. High levels of K, Zn, As, Cd and Pb were found in fine particles, confirming the contribution of biomass burning and vehicle emissions, whereas Na, Al, K, Fe and Zn were the representative elements in ultrafine particles, influenced by a diversity of sources.
Resumo:
286 p. : il. col.
Resumo:
Os hidrocarbonetos policíclicos aromáticos (HPAs) estão associados ao aumento da incidência de diversos tipos de cânceres no homem. Essas moléculas são formadas principalmente na queima incompleta de matéria orgânica, sendo encontradas em todos os compartimentos ambientais. Órgãos regulamentadores das áreas ambiental e de saúde ocupacional consideram 17 HPAs como contaminantes atmosféricos prioritários. Este trabalho apresenta um método para análise simultânea destes HPAs utilizando-se a cromatografia a gás acoplada à espectrometria de massas operando no modo tandem (GC-MS/MS). Os limites de detecção e quantificação do método mostraram-se até 5 vezes inferiores aos obtidos no método GC-MS (SCAN). O método mostrou-se seletivo para análise de HPAs em extratos de amostras de material particulado atmosférico. Uma análise comparativa de dois sistemas de solventes (diclorometano/metanol 4:1 v/v e hexano/acetona 1:1 v/v) para a extração de HPAs, utilizando amostras de material particulado atmosférico, revelou que ambas as misturas de solventes possuem poder de extração semelhante. Os resultados sugerem que é possível realizar extração de HPAs de material particulado atmosférico em ultra-som com a mistura hexano/acetona (1:1), que é menos tóxica em relação à mistura diclorometano/metanol (4:1), bastante utilizada nestas análises, sem perdas significativas na exatidão do método.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Química - IQ
Resumo:
This study aimed to determine the concentration and inorganic chemical composition of samples from airborne particulate matter inhaled in fine and coarse fractions. Aerosol samples were collected in 2013 and 2014, from sites located in the cities of Londrina and Maringa, in the state of Paraná, Brazil. The samples were collected daily (24h) in two campaigns: winter and summer. For the collection, was used a dichotomous sampler with quartz fiber filter with 47 mm in size and 2 µm porosity, 97% efficiency, retaining particles of up to 0.3 µm. Quantification of the airborne particulate matter mass was performed by gravimetry method. The results from Londrina to PM2.5 and MP2,5-10 represent, respectively, 29.2% and 70.8% of airborne particulate matter in the winter campaign (2013), 30.9% (PM2.5) and 69.1 % (MP2,5-10) in the summer campaign (2013), and 35.9% (PM2.5) and 64.1% (MP2,5-10) in the winter 2014 campaign. In the city of Maringa, the results presented the percentage of 42.0% (PM2.5) and 58.0% (MP2,5-10) for the winter season (2014), and 28.8% (PM2.5) and 71.2 % (MP2,5-10) for the summer season (2014). The PM2.5/PM10 ratio was on average 0.3, demonstrating that both cities are developing urban areas. Analysis of the major soluble inorganic species in water (NO3-, SO42- and Cl-) associated with MP2,5-10 were quantified by ion chromatography at the LACA Laboratory in the State University of Londrina, with the largest contribution found in all campaigns was to NO3-. The NO3-/SO42- ratios above 1.0 indicate the local traffic contribution. The analysis of metals associated with PM2.5 was carried out by mass spectrometry with inductively coupled plasma (ICP-MS) in the Federal University of Santa Catarina. The Zn, Pb, Cu and Mn concentrations found in all campaigns indicate the contribution of mobile sources to PM2.5. The concentration of BCe in PM2.5 was determined by reflectance, with higher BCe concentrations being found in winter campaigns. In general, Londrina presented the highest concentrations from the species analyzed when compared to Maringá. In addition, the analysis of the air mass trajectories indicated the transportation of pollutants coming mainly from fires in the southeastern region of the country.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Tecnologia Química e Biológica, 2016.
Resumo:
This study aimed to assess ambient air quality in a urban area of Natal, capital of Rio Grande do Norte (latitude 5º49'29 '' S and longitude 35º13'34'' W), aiming to determine the metals concentration in particulate matter (PM10 and PM2,5) of atmospheric air in the urban area o the Natal city. The sampling period for the study consisted of data acquisition from January to December 2012. Samples were collected on glass fiber filters by means of two large volumes samplers, one for PM2,5 (AGV PM 2,5) and another for PM10 (PM10 AGV). Monthly averages ranged from 8.92 to 19.80 g.m-3 , where the annual average was 16,21 g.m-3 for PM10 and PM2,5 monthly averages ranged from 2,84 to 7,89 g.m -3 , with an annual average of 5,61 g.m-3 . The results of PM2,5 and PM10 concentrations were related meteorological variables and for information on the effects of these variables on the concentration of PM, an exploratory analysis of the data using Principal Component Analysis (PCA) was performed. The results of the PCA showed that with increasing barometric pressure, the direction of the winds, the rainfall and relative humidity decreases the concentration of PM and the variable weekday little influence compared the meteorological variables. Filters containing particulate matter were selected in six days and subjected to microwave digestion. After digestion samples were analyzed by with Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The concentrations for heavy metals Vanadium, Chromium, Manganese, Nickel, Copper, Arsenic and lead were determined. The highest concentrations of metals were for Pb and Cu, whose average PM10 values were, respectively, 5,34 and 2,34 ng.m-3 and PM2,5 4,68 and 2,95 ng.m-3 . Concentrations for metals V, Cr, Mn, Ni, and Cd were respectively 0,13, 0,39, 0,48, 0,45 and 0,03 ng.m-3 for PM10 fraction and PM2,5 fraction, 0,05, 0,10, 0,10, 0,34 and 0,01 ng.m-3. The concentration for As was null for the two fractions
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Este estudo teve como objetivo principal caracterizar os padrões de distribuição do material particulado em suspensão ao longo da baía de Sepetiba, associando as variabilidades espaciais e temporais com ciclos de maré. Além disso, o estudo também avalia a utilização de equipamentos acústicos como ferramentas à estimativa das concentrações de material particulado em suspensão. A aquisição de dados foi realizada num total de sete campanhas realizadas entre novembro de 2010 e dezembro de 2011. Sete estações foram posicionadas nas proximidades do canal principal de acesso à baía, ao longo de um transecto que se estende do seu interior até sua desembocadura. As sete campanhas amostrais se distribuem em duas séries longas, de 13 e 25 horas, de aquisição em um ponto fixo, e cinco amostragens ao longo das estações. A aquisição de dados envolve: coleta de amostras de água, utilizadas nas estimativas das concentrações de material particulado; coleta de sedimentos de fundo para caracterização granulométrica das estações amostradas; perfis de parâmetros físico-químicos; dados de correntômetria adquiridos junto ao fundo. O processamento das amostras de água e sedimentos foi realizado no laboratório de Geologia Marinha da Faculdade de Oceanografia da Universidade do Estado do Rio de Janeiro. As concentrações de material particulado em suspensão foram utilizadas na calibração de sensores acústicos e óticos, permitindo uma avaliação espaço-temporal mais detalhada dos padrões de distribuição junto ao fundo e ao longo da coluna dágua. Os dados observados permitiram identificar que as maiores concentrações de material particulado em suspensão ocorrem em condições de maré enchente, e estão associadas à assimetria de maré. A baía pode ser dividida em dois setores: um na porção mais interna, onde se observou maior influência do aporte fluvial, onde as concentrações de material particulado em suspensão respondem à propagação da pluma do canal de São Francisco; e outro que se estende da porção central até sua desembocadura, onde predomina o domínio marinho, com influência de eventos oriundos da plataforma continental. Também pode ser identificada a influência do fenômeno La Niña, que provavelmente foi responsável por: altas salinidades encontradas no interior da baía e ocorrência da Água Central do Atlântico Sul à baixas profundidades. Quanto à utilização de equipamentos acústicos nas estimativas das concentrações de material particulado, os dados se demonstraram ricos em detalhes, que permitiram avaliar o comportamento do material particulado junto ao fundo frente a diferentes condições de maré, turbulência e incidência de oscilações.