936 resultados para Markerless motion analysis
Resumo:
Motor dysfunction is consistently reported but understudied in schizophrenia. It has been hypothesized that this abnormality may reflect a neuro-developmental disorder underlying this illness. The main goal of this study was to analyze movement patterns used by participants with schizophrenia and healthy controls during overarm throwing performance, using a markerless motion capture system. Thirteen schizophrenia patients and 16 healthy control patients performed the overarm throwing task in a markerless motion capture system. Participants were also examined for the presence of motor neurological soft signs (mNSS) using the Brief Motor Scale. Schizophrenia patients demonstrated a less developed movement pattern with low individualization of components compared to healthy controls. The schizophrenia group also displayed a higher incidence of mNSS. The presence of a less mature movement pattern can be an indicator of neuro-immaturity and a marker for atypical neurological development in schizophrenia. Our findings support the understanding of motor dysfunction as an intrinsic part of the disorder of schizophrenia.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Mixed martial arts (MMA) have become a fast-growing worldwide expansion of martial arts competition, requiring high level of skill, physical conditioning, and strategy, and involving a synthesis of combat while standing or on the ground. This study quantified the effort-pause ratio (EP), and classified effort segments of stand-up or groundwork development to identify the number of actions performed per round in MMA matches. 52 MMA athletes participated in the study (M age = 24 yr., SD = 5; average experience in MMA = 5 yr., SD = 3). A one-way analysis of variance with repeated measurements was conducted to compare the type of action across the rounds. A chi-squared test was applied across the percentages to compare proportions of different events. Only one significant difference (p < .05) was observed among rounds: time in groundwork of low intensity was longer in the second compared to the third round. When the interval between rounds was not considered, the EP ratio (between high-intensity effort to low-intensity effort plus pauses) WE S 1:2 to 1:4. This ratio is between ratios typical for judo, wrestling, karate, and taekwondo and reflects the combination of ground and standup techniques. Most of the matches ended in the third round, involving high-intensity actions, predominantly executed during groundwork combat.
Resumo:
Time motion analysis is extensively used to assess the demands of team sports. At present there is only limited information on the reliability of measurements using this analysis tool. The aim of this study was to establish the reliability of an individual observer's time motion analysis of rugby union. Ten elite level rugby players were individually tracked in Southern Hemisphere Super 12 matches using a digital video camera. The video footage was subsequently analysed by a single researcher on two occasions one month apart. The test-retest reliability was quantified as the typical error of measurement (TEM) and rated as either good (10% TEM). The total time spent in the individual movements of walking, jogging, striding, sprinting, static exertion and being stationary had moderate to poor reliability (5.8-11.1% TEM). The frequency of individual movements had good to poor reliability (4.3-13.6% TEM), while the mean duration of individual movements had moderate reliability (7.1-9.3% TEM). For the individual observer in the present investigation, time motion analysis was shown to be moderately reliable as an evaluation tool for examining the movement patterns of players in competitive rugby. These reliability values should be considered when assessing the movement patterns of rugby players within competition.
Resumo:
El treball presentat suposa una visió general de l'"Endoscopia amb Càpsula de Vídeo Wireless" i la inspecció de sequències de contraccions intestinals amb les últimes tecnologies de visió per computador. Després de la observació preliminar dels fonaments mèdics requerits, la aplicació de visió per computador es presenta en aquestos termes. En essència, aquest treball proveïx una exhaustiva selecció, descripció i avaluació de cert conjunt de mètodes de processament d'imatges respecte a l'anàlisi de moviment, en el entorn de seqüències d'imatges preses amb una càpsula endoscòpica. Finalment, es presenta una aplicació de software per configurar i emprar de forma ràpida i fàcil un entorn experimental.
Resumo:
This paper describes a realistic simulator for the Computed Tomography (CT) scan process for motion analysis. In fact, we are currently developing a new framework to find small motion from the CT scan. In order to prove the fidelity of this framework, or potentially any other algorithm, we present in this paper a simulator to simulate the whole CT acquisition process with a priori known parameters. In other words, it is a digital phantom for the motion analysis that can be used to compare the results of any related algorithm with the ground-truth realistic analytical model. Such a simulator can be used by the community to test different algorithms in the biomedical imaging domain. The most important features of this simulator are its different considerations to simulate the best the real acquisition process and its generality.
Resumo:
Intracranial aneurysms are a common pathologic condition with a potential severe complication: rupture. Effective treatment options exist, neurosurgical clipping and endovascular techniques, but guidelines for treatment are unclear and focus mainly on patient age, aneurysm size, and localization. New criteria to define the risk of rupture are needed to refine these guidelines. One potential candidate is aneurysm wall motion, known to be associated with rupture but difficult to detect and quantify. We review what is known about the association between aneurysm wall motion and rupture, which structural changes may explain wall motion patterns, and available imaging techniques able to analyze wall motion.
Resumo:
The aim of the present study was to determine the effect of volume and composition of fluid replacement on the physical performance of male football referees. Ten referees were evaluated during three official matches. In one match the participants were asked to consume mineral water ad libitum, and in the others they consumed a pre-determined volume of mineral water or a carbohydrate electrolyte solution (6.4% carbohydrate and 22 mM Na+) equivalent to 1% of their baseline body mass (half before the match and half during the interval). Total water loss, sweat rate and match physiological performance were measured. When rehydrated ad libitum (pre-match and at half time) participants lost 1.97 ± 0.18% of their pre-match body mass (2.14 ± 0.19 L). This parameter was significantly reduced when they consumed a pre-determined volume of fluid. Sweat rate was significantly reduced when the referees ingested a pre-determined volume of a carbohydrate electrolyte solution, 0.72 ± 0.12 vs 1.16 ± 0.11 L/h ad libitum. The high percentage (74.1%) of movements at low speed (walking, jogging) observed when they ingested fluid ad libitum was significantly reduced to 71% with mineral water and to 69.9% with carbohydrate solution. An increase in percent movement expended in backward running was observed when they consumed a pre-determined volume of carbohydrate solution, 7.7 ± 0.5 vs 5.5 ± 0.5% ad libitum. The improved hydration status achieved with the carbohydrate electrolyte solution reduced the length of time spent in activities at low-speed movements and increased the time spent in activities demanding high-energy expenditure.
Resumo:
The usefulness of motor subtypes of delirium is unclear due to inconsistency in sub-typing methods and a lack of validation with objective measures of activity. The activity of 40 patients was measured with 24 h accelerometry monitoring. Patients with Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) delirium (n = 30) were allocated into hyperactive, hypoactive and mixed motor subtypes. Delirium subtypes differed in relation to overall amount of activity, including movement in both sagittal and transverse planes. Differences were greater in the daytime and during the early evening ‘sundowning’ period. Frequency of postural changes was the most discriminating measure examined. Clinical subtypes of delirium defined by observed motor behaviour on the ward differ in electronically measured activity levels.
Resumo:
An algorithm for tracking multiple feature positions in a dynamic image sequence is presented. This is achieved using a combination of two trajectory-based methods, with the resulting hybrid algorithm exhibiting the advantages of both. An optimizing exchange algorithm is described which enables short feature paths to be tracked without prior knowledge of the motion being studied. The resulting partial trajectories are then used to initialize a fast predictor algorithm which is capable of rapidly tracking multiple feature paths. As this predictor algorithm becomes tuned to the feature positions being tracked, it is shown how the location of occluded or poorly detected features can be predicted. The results of applying this tracking algorithm to data obtained from real-world scenes are then presented.
Resumo:
Analysis of human behaviour through visual information has been a highly active research topic in the computer vision community. This was previously achieved via images from a conventional camera, but recently depth sensors have made a new type of data available. This survey starts by explaining the advantages of depth imagery, then describes the new sensors that are available to obtain it. In particular, the Microsoft Kinect has made high-resolution real-time depth cheaply available. The main published research on the use of depth imagery for analysing human activity is reviewed. Much of the existing work focuses on body part detection and pose estimation. A growing research area addresses the recognition of human actions. The publicly available datasets that include depth imagery are listed, as are the software libraries that can acquire it from a sensor. This survey concludes by summarising the current state of work on this topic, and pointing out promising future research directions.
Resumo:
The aim of this thesis was to describe the development of motion analysis protocols for applications on upper and lower limb extremities, by using inertial sensors-based systems. Inertial sensors-based systems are relatively recent. Knowledge and development of methods and algorithms for the use of such systems for clinical purposes is therefore limited if compared with stereophotogrammetry. However, their advantages in terms of low cost, portability, small size, are a valid reason to follow this direction. When developing motion analysis protocols based on inertial sensors, attention must be given to several aspects, like the accuracy of inertial sensors-based systems and their reliability. The need to develop specific algorithms/methods and software for using these systems for specific applications, is as much important as the development of motion analysis protocols based on them. For this reason, the goal of the 3-years research project described in this thesis was achieved first of all trying to correctly design the protocols based on inertial sensors, in terms of exploring and developing which features were suitable for the specific application of the protocols. The use of optoelectronic systems was necessary because they provided a gold standard and accurate measurement, which was used as a reference for the validation of the protocols based on inertial sensors. The protocols described in this thesis can be particularly helpful for rehabilitation centers in which the high cost of instrumentation or the limited working areas do not allow the use of stereophotogrammetry. Moreover, many applications requiring upper and lower limb motion analysis to be performed outside the laboratories will benefit from these protocols, for example performing gait analysis along the corridors. Out of the buildings, the condition of steady-state walking or the behavior of the prosthetic devices when encountering slopes or obstacles during walking can also be assessed. The application of inertial sensors on lower limb amputees presents conditions which are challenging for magnetometer-based systems, due to ferromagnetic material commonly adopted for the construction of idraulic components or motors. INAIL Prostheses Centre stimulated and, together with Xsens Technologies B.V. supported the development of additional methods for improving the accuracy of MTx in measuring the 3D kinematics for lower limb prostheses, with the results provided in this thesis. In the author’s opinion, this thesis and the motion analysis protocols based on inertial sensors here described, are a demonstration of how a strict collaboration between the industry, the clinical centers, the research laboratories, can improve the knowledge, exchange know-how, with the common goal to develop new application-oriented systems.