996 resultados para Manipulation techniques
Resumo:
An experiment was conducted to induce triploidy in African catfish, Clarias gariepinus, using heat shock and cold shock techniques. Cold shock at a temperature of 0± 1°C and 5±1°C for a duration of 15, 30, 45 and 60 min and heat shock at a temperature of 40±0.5°C and 41 ±OS C for a duration of 1, 2 and 3 min was given to induce triploidy 5 min after fertilization. Maximum percentage of triploids (91.4%) were obtained in the heat shock at a temperature of 40±0SC for a duration of 1 min whereas cold shock at 0± 1 C for a duration of 60 min yielded 90% of triploids. Chromosome analysis revealed that diploids have 54 chromosomes and triploids have 81 chromosomes. The erythrocyte measurements of the minor axis and major axis were 1.17 times larger in treated fish than in controls. The growth studies showed that the growth rate was not significantly affected in triploids.
Resumo:
Human ingenuity has made it possible to advent the chromosome manipulation techniques to produce individuals with differing genomic status in a number of fish using various causal agents such as physical shocks (temperature or hydrostatic pressure), chemical (endomitotics) and anesthetic treatments either to suppress the second meiotic division shortly after fertilization of eggs or to prevent the first mitotic division shortly prior to mitotic cleavage formation. This results in the induction of polyploidy (triploidy and tetraploidy), gynogenesis (both meiotic and mitotic leading to clonal lines) and androgenesis in fish population. The rationale for the induction of such ploidy in fish has been its potential for generating sterile individuals, rapidly inbred lines and masculinized fish, which could be of benefit to fish farming and aquaculture. In this paper, these are critically reviewed and the implication of recently developed chromosome manipulation techniques to various fin fishes is discussed.
Resumo:
Aims: To develop clinical protocols for acquiring PET images, performing CT-PET registration and tumour volume definition based on the PET image data, for radiotherapy for lung cancer patients and then to test these protocols with respect to levels of accuracy and reproducibility. Method: A phantom-based quality assurance study of the processes associated with using registered CT and PET scans for tumour volume definition was conducted to: (1) investigate image acquisition and manipulation techniques for registering and contouring CT and PET images in a radiotherapy treatment planning system, and (2) determine technology-based errors in the registration and contouring processes. The outcomes of the phantom image based quality assurance study were used to determine clinical protocols. Protocols were developed for (1) acquiring patient PET image data for incorporation into the 3DCRT process, particularly for ensuring that the patient is positioned in their treatment position; (2) CT-PET image registration techniques and (3) GTV definition using the PET image data. The developed clinical protocols were tested using retrospective clinical trials to assess levels of inter-user variability which may be attributed to the use of these protocols. A Siemens Somatom Open Sensation 20 slice CT scanner and a Philips Allegro stand-alone PET scanner were used to acquire the images for this research. The Philips Pinnacle3 treatment planning system was used to perform the image registration and contouring of the CT and PET images. Results: Both the attenuation-corrected and transmission images obtained from standard whole-body PET staging clinical scanning protocols were acquired and imported into the treatment planning system for the phantom-based quality assurance study. Protocols for manipulating the PET images in the treatment planning system, particularly for quantifying uptake in volumes of interest and window levels for accurate geometric visualisation were determined. The automatic registration algorithms were found to have sub-voxel levels of accuracy, with transmission scan-based CT-PET registration more accurate than emission scan-based registration of the phantom images. Respiration induced image artifacts were not found to influence registration accuracy while inadequate pre-registration over-lap of the CT and PET images was found to result in large registration errors. A threshold value based on a percentage of the maximum uptake within a volume of interest was found to accurately contour the different features of the phantom despite the lower spatial resolution of the PET images. Appropriate selection of the threshold value is dependant on target-to-background ratios and the presence of respiratory motion. The results from the phantom-based study were used to design, implement and test clinical CT-PET fusion protocols. The patient PET image acquisition protocols enabled patients to be successfully identified and positioned in their radiotherapy treatment position during the acquisition of their whole-body PET staging scan. While automatic registration techniques were found to reduce inter-user variation compared to manual techniques, there was no significant difference in the registration outcomes for transmission or emission scan-based registration of the patient images, using the protocol. Tumour volumes contoured on registered patient CT-PET images using the tested threshold values and viewing windows determined from the phantom study, demonstrated less inter-user variation for the primary tumour volume contours than those contoured using only the patient’s planning CT scans. Conclusions: The developed clinical protocols allow a patient’s whole-body PET staging scan to be incorporated, manipulated and quantified in the treatment planning process to improve the accuracy of gross tumour volume localisation in 3D conformal radiotherapy for lung cancer. Image registration protocols which factor in potential software-based errors combined with adequate user training are recommended to increase the accuracy and reproducibility of registration outcomes. A semi-automated adaptive threshold contouring technique incorporating a PET windowing protocol, accurately defines the geometric edge of a tumour volume using PET image data from a stand alone PET scanner, including 4D target volumes.
Resumo:
A discussion is presented on endocrine sex reversal and chromosome manipulation techniques for producing 1005 male tilapia. Details are given of methods for the administration of steroids and the induction of ploidy.
Resumo:
Of late, the magnetic properties of micro/nano-structures have attracted intense research interest both fundamentally and technologically particularly to address the question that how the manipulation in the different layers of nanostructures, geometry of a patterned structure can affect the overall magnetic properties, while generating novel applications such as in magnetic sensors, storage devices, integrated inductive components and spintronic devices. Depending on the applications, materials with high, medium or low magnetic anisotropy and their possible manipulation are required. The most dramatic manifestation in this respect is the chance to manipulate the magnetic anisotropy over the intrinsic preferential direction of the magnetization, which can open up more functionality particularly for device applications. Types of magnetic anisotropies of different nanostructured materials and their manipulation techniques are investigated in this work. Detail experimental methods for the quantitative determination of magnetic anisotropy in nanomodulated Ni45Fe55 thin film are studied. Magnetic field induced in-plane rotations within the nanomodulated Ni45Fe55 continuous films revealed various rotational symmetries of magnetic anisotropy due to dipolar interactions showing a crossover from lower to higher fold of symmetry as a function of modulation geometry. In a second approach, the control of exchange anisotropy at ferromagnetic (FM) – aniferomagnetic (AFM) interface in multifferoic nanocomposite materials, where two different phase/types of materials were simultaneously synthesized, was investigated. The third part of this work was to study the electroplated thin films of metal alloy nanocomposite for enhanced exchange anisotropy. In this work a unique observation of an anti-clock wise as well as a clock wise hysteresis loop formation in the Ni,Fe solid solution with very low coercivity and large positive exchange anisotropy/exchange bias have been investigated. Hence, controllable positive and negative exchange anisotropy has been observed for the first time which has high potential applications such as in MRAM devices.
Resumo:
The majority of randomized clinical trials (RCTs) of spinal manipulative therapy have not adequately de?ned the terms ‘mobilization’ and ‘manipulation’, nor distinguished between these terms in reporting the trial interventions. The purpose of this study was to describe the spinal manipulative therapy techniques utilized within a RCT of manipulative therapy (MT; n=80), interferential therapy (IFT; n=80), and a combination of both (CT; n=80) for people with acute low back pain (LBP). Spinal manipulative therapy was de?ned as any ‘mobilization’ (low velocity manual force without a thrust) or ‘manipulation’ (high velocity
thrust) techniques of the spine described by Maitland and Cyriax.
The 16 physiotherapists, all members of the Society of Orthopaedic Medicine, utilized three spinal manipulative therapy patterns in the RCT: Maitland Mobilization (40.4%, n=59), Maitland Mobilization/Cyriax Manipulation (40.4%, n=59) and Cyriax Manipulation (19.1%, n=28). There was a signi?cant difference between the MT and CT groups in their usage of spinal manipulative therapy techniques (w2=9.178; df=2;P=0.01); subjects randomized to the CT group received three times more Cyriax Manipulation (29.2%, n=21/72) than those randomized to the MT group (9.5%, n=7/74; df=1; P=0.003).
The use of mobilization techniques within the trial was comparable with their usage by the general population of physiotherapists in Britain and Ireland for LBP management. However, the usage of manipulation techniques was considerably higher than reported in physiotherapy surveys and may re?ect the postgraduate training of trial therapists.
Resumo:
We introduce a broad lattice manipulation technique for expressive cryptography, and use it to realize functional encryption for access structures from post-quantum hardness assumptions. Specifically, we build an efficient key-policy attribute-based encryption scheme, and prove its security in the selective sense from learning-with-errors intractability in the standard model.
Resumo:
Recent progress in plasma science and technology has enabled the development of a new generation of stable cold non-equilibrium plasmas operating at ambient atmospheric pressure. This opens horizons for new plasma technologies, in particular in the emerging field of plasma medicine. These non-equilibrium plasmas are very efficient sources for energy transport through reactive neutral particles (radicals and metastables), charged particles (ions and electrons), UV radiation, and electro-magnetic fields. The effect of a cold radio frequency-driven atmospheric pressure plasma jet on plasmid DNA has been investigated. The formation of double strand breaks correlates well with the atomic oxygen density. Taken with other measurements, this indicates that neutral components in the jet are effective in inducing double strand breaks. Plasma manipulation techniques for controlled energy delivery are highly desirable. Numerical simulations are employed for detailed investigations of the electron dynamics, which determines the generation of reactive species. New concepts based on nonlinear power dissipation promise superior strategies to control energy transport for tailored technological exploitations. © 2012 American Institute of Physics.
Resumo:
Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação de Drª Mónica D’Orey
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência e Tecnologia Animal - FEIS
Resumo:
The aim of program specialization is to optimize programs by exploiting certain knowledge about the context in which the program will execute. There exist many program manipulation techniques which allow specializing the program in different ways. Among them, one of the best known techniques is partial evaluation, often referred to simply as program specialization, which optimizes programs by specializing them for (partially) known input data. In this work we describe abstract specialization, a technique whose main features are: (1) specialization is performed with respect to "abstract" valúes rather than "concrete" ones, and (2) abstract interpretation rather than standard interpretation of the program is used in order to propágate information about execution states. The concept of abstract specialization is at the heart of the specialization system in CiaoPP, the Ciao system preprocessor. In this paper we present a unifying view of the different specialization techniques used in CiaoPP and discuss their potential applications by means of examples. The applications discussed include program parallelization, optimization of dynamic scheduling (concurreney), and integration of partial evaluation techniques.
Resumo:
En esta tesis se propone un procedimiento para evaluar la resistencia mecánica de obleas de silicio cristalino y se aplica en diferentes casos válidos para la industria. En el sector de la industria fotovoltaica predomina la tecnología basada en paneles de silicio cristalino. Estos paneles están compuestos por células solares conectadas en serie y estas células se forman a partir de obleas de silicio. Con el objetivo de disminuir el coste del panel, en los últimos años se ha observado una clara tendencia a la reducción del espesor de las obleas. Esta reducción del espesor modifica la rigidez de las obleas por lo que ha sido necesario modificar la manera tradicional de manipularlas con el objetivo de mantener un bajo ratio de rotura. Para ello, es necesario conocer la resistencia mecánica de las obleas. En la primera parte del trabajo se describen las obleas de silicio, desde su proceso de formación hasta sus propiedades mecánicas. Se muestra la influencia de la estructura cristalográfica en la resistencia y en el comportamiento ya que el cristal de silicio es anisótropo. Se propone también el método de caracterización de la resistencia. Se utiliza un criterio probabilista basado en los métodos de dimensionamiento de materiales frágiles en el que la resistencia queda determinada por los parámetros de la ley de Weibull triparamétrica. Se propone el procedimiento para obtener estos parámetros a partir de campañas de ensayos, modelización numérica por elementos finitos y un algoritmo iterativo de ajuste de los resultados. En la segunda parte de la tesis se describen los diferentes tipos de ensayos que se suelen llevar a cabo con este material. Se muestra además, para cada uno de los ensayos descritos, un estudio comparativo de diferentes modelos de elementos finitos simulando los ensayos. Se comparan tanto los resultados aportados por cada modelo como los tiempos de cálculo. Por último, se presentan tres aplicaciones diferentes donde se ha aplicado este procedimiento de estudio. La primera aplicación consiste en la comparación de la resistencia mecánica de obleas de silicio en función del método de crecimiento del lingote. La resistencia de las tradicionales obleas monocristalinas obtenidas por el método Czochralski y obleas multicristalinas es comparada con las novedosas obleas quasi-monocristalinas obtenidas por métodos de fundición. En la segunda aplicación se evalúa la profundidad de las grietas generadas en el proceso de corte del lingote en obleas. Este estudio se realiza de manera indirecta: caracterizando la resistencia de grupos de obleas sometidas a baños químicos de diferente duración. El baño químico reduce el espesor de las obleas eliminando las capas más dañadas. La resistencia de cada grupo es analizada y la comparación permite obtener la profundidad de las grietas generadas en el proceso de corte. Por último, se aplica este procedimiento a un grupo de obleas con características muy especiales: obleas preparadas para formar células de contacto posterior EWT. Estas obleas presentan miles de agujeros que las debilitan considerablemente. Se aplica el procedimiento de estudio propuesto con un grupo de estas obleas y se compara la resistencia obtenida con un grupo de referencia. Además, se propone un método simplificado de estudio basado en la aplicación de una superficie de intensificación de tensiones. ABSTRACT In this thesis, a procedure to evaluate the mechanical strength of crystalline silicon wafers is proposed and applied in different studies. The photovoltaic industry is mainly based on crystalline silicon modules. These modules are composed of solar cells which are based on silicon wafers. Regarding the cost reduction of solar modules, a clear tendency to use thinner wafers has been observed during last years. Since the stiffness varies with thickness, the manipulation techniques need to be modified in order to guarantee a low breakage rate. To this end, the mechanical strength has to be characterized correctly. In the first part of the thesis, silicon wafers are described including the different ways to produce them and the mechanical properties of interest. The influence of the crystallographic structure in the strength and the behaviour (the anisotropy of the silicon crystal) is shown. In addition, a method to characterize the mechanical strength is proposed. This probabilistic procedure is based on methods to characterize brittle materials. The strength is characterized by the values of the three parameters of the Weibull cumulative distribution function (cdf). The proposed method requires carrying out several tests, to simulate them through Finite Element models and an iterative algorithm in order to estimate the parameters of the Weibull cdf. In the second part of the thesis, the different types of test that are usually employed with these samples are described. Moreover, different Finite Element models for the simulation of each test are compared regarding the information supplied by each model and the calculation times. Finally, the method of characterization is applied to three examples of practical applications. The first application consists in the comparison of the mechanical strength of silicon wafers depending on the ingot growth method. The conventional monocrystalline wafers based on the Czochralski method and the multicrystalline ones are compared with the new quasi-monocrystalline substrates. The second application is related to the estimation of the crack length caused by the drilling process. An indirect way is used to this end: several sets of silicon wafers are subjected to chemical etchings of different duration. The etching procedure reduces the thickness of the wafers removing the most damaged layers. The strength of each set is obtained by means of the proposed method and the comparison permits to estimate the crack length. At last, the procedure is applied to determine the strength of wafers used for the design of back-contact cells of type ETW. These samples are drilled in a first step resulting in silicon wafers with thousands of tiny holes. The strength of the drilled wafers is obtained and compared with the one of a standard set without holes. Moreover, a simplified approach based on a stress intensification surface is proposed.
Resumo:
Gene transfer to eukaryotic cells requires the uptake of exogenous DNA into the cell nucleus. Except during mitosis, molecular access to the nuclear interior is limited to passage through the nuclear pores. Here we demonstrate the nuclear uptake of extended linear DNA molecules by a combination of fluorescence microscopy and single-molecule manipulation techniques, using the latter to follow uptake kinetics of individual molecules in real time. The assays were carried out on nuclei reconstituted in vitro from extracts of Xenopus eggs, which provide both a complete complement of biochemical factors involved in nuclear protein import, and unobstructed access to the nuclear pores. We find that uptake of DNA is independent of ATP or GTP hydrolysis, but is blocked by wheat germ agglutinin. The kinetics are much slower than would be expected from hydrodynamic considerations. A fit of the data to a simple model suggests femto-Newton forces and a large friction relevant to the uptake process.
Resumo:
Humanity is shaped by its relationships with microbes. From bacterial infections to the production of biofuels, industry and health often hinge on our control of microbial populations. Understanding the physiological and genetic basis of their behaviors is therefore of the highest importance. To this end I have investigated the genetic basis of plastic adhesion in Saccharomyces cerevisiae, the mechanistic and evolutionary dynamics of mixed species biofilms with Escherichia coli and S. cerevisiae, and the induction of filamentation in E. coli. Using a bulk segregant analysis on experimentally evolved populations, I detected 28 genes that are likely to mediate plastic adhesion in S. cerevisiae. With a variety of imaging and culture manipulation techniques, I found that particular strains of E. coli are capable of inducing flocculation and macroscopic biofilm formation via coaggregation with yeast. I also employed experimental evolution and microbial demography techniques to find that selection for mixed species biofilm association leads to lower fecundity in S. cerevisiae. Using culture manipulation and imaging techniques, I also found that E. coli are capable of inducing a filamentous phenotype with a secreted signal that has many of the qualities of a quorum sensing molecule.