33 resultados para Manikin


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, computational fluid dynamics (CFD) has been widely used as a method of simulating airflow and addressing indoor environment problems. The complexity of airflows within the indoor environment would make experimental investigation difficult to undertake and also imposes significant challenges on turbulence modelling for flow prediction. This research examines through CFD visualization how air is distributed within a room. Measurements of air temperature and air velocity have been performed at a number of points in an environmental test chamber with a human occupant. To complement the experimental results, CFD simulations were carried out and the results enabled detailed analysis and visualization of spatial distribution of airflow patterns and the effect of different parameters to be predicted. The results demonstrate the complexity of modelling human exhalation within a ventilated enclosure and shed some light into how to achieve more realistic predictions of the airflow within an occupied enclosure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of a thermal buttocks manikin(1) was explored as a tool to standardize the evaluation of seat comfort. Thermal manikin buttocks were developed and calibrated thermally and anatomically to simulate the sensible heat transfer of a seated person and used to evaluate interface pressure distribution. In essence, the pressure maps of manikin buttocks with and without heating were compared to those of a seated person. The results of average pressure demonstrated that the thermal manikins have a better response in interface pressure measurement than manikins without heating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this randomized, open, controlled crossover manikin study was to compare the performance of "Animax", a manually operated hand-powered mechanical resuscitation device (MRD) to standard single rescuer basic life support (BLS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to determine whether the British Heart Foundation (BHF) PocketCPR application can improve the depth and rate of chest compression, and therefore be confidently recommended for bystander use. 118 candidates were recruited into a randomised crossover manikin trial. Each candidate performed CPR for two-minutes without instruction, or performed chest compressions using the PocketCPR application. Candidates then performed a further two minutes of CPR within the opposite arm. The number of chest compressions performed improved when PocketCPR was used compared to chest compressions when it was not (44.28% v40.57, P<0.001). The number of chest compressions performed to the required depth was higher in the PocketCPR group (90.86 v 66.26). The BHF PocketCPR application improved the percentage of chest compressions that were performed to the required depth. Despite this, more work is required in order to develop a feedback device that can improve bystander CPR without creating delay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: In the current climate of medical education, there is an ever-increasing demand for and emphasis on simulation as both a teaching and training tool. The objective of our study was to compare the realism and practicality of a number of artificial blood products that could be used for high-fidelity simulation. Method: A literature and internet search was performed and 15 artificial blood products were identified from a variety of sources. One product was excluded due to its potential toxicity risks. Five observers, blinded to the products, performed two assessments on each product using an evaluation tool with 14 predefined criteria including color, consistency, clotting, and staining potential to manikin skin and clothing. Each criterion was rated using a five-point Likert scale. The products were left for 24 hours, both refrigerated and at room temperature, and then reassessed. Statistical analysis was performed to identify the most suitable products, and both inter- and intra-rater variability were examined. Results: Three products scored consistently well with all five assessors, with one product in particular scoring well in almost every criterion. This highest-rated product had a mean rating of 3.6 of 5.0 (95% posterior Interval 3.4-3.7). Inter-rater variability was minor with average ratings varying from 3.0 to 3.4 between the highest and lowest scorer. Intrarater variability was negligible with good agreement between first and second rating as per weighted kappa scores (K = 0.67). Conclusion: The most realistic and practical form of artificial blood identified was a commercial product called KD151 Flowing Blood Syrup. It was found to be not only realistic in appearance but practical in terms of storage and stain removal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High fidelity simulation as a teaching and learning approach is being embraced by many schools of nursing. Our school embarked on integrating high fidelity (HF) simulation into the undergraduate clinical education program in 2011. Low and medium fidelity simulation has been used for many years, but this did not simplify the integration of HF simulation. Alongside considerations of how and where HF simulation would be integrated, issues arose with: student consent and participation for observed activities; data management of video files; staff development, and conceptualising how methods for student learning could be researched. Simulation for undergraduate student nurses commenced as a formative learning activity, undertaken in groups of eight, where four students undertake the ‘doing’ role and four are structured observers, who then take a formal role in the simulation debrief. Challenges for integrating simulation into student learning included conceptualising and developing scenarios to trigger students’ decision making and application of skills, knowledge and attitudes explicit to solving clinical ‘problems’. Developing and planning scenarios for students to ‘try out’ skills and make decisions for problem solving lay beyond choosing pre-existing scenarios inbuilt with the software. The supplied scenarios were not concept based but rather knowledge, skills and technology (of the manikin) focussed. Challenges lay in using the technology for the purpose of building conceptual mastery rather than using technology simply because it was available. As we integrated use of HF simulation into the final year of the program, focus was on building skills, knowledge and attitudes that went beyond technical skill, and provided an opportunity to bridge the gap with theory-based knowledge that students often found difficult to link to clinical reality. We wished to provide opportunities to develop experiential knowledge based on application and clinical reasoning processes in team environments where problems are encountered, and to solve them, the nurse must show leadership and direction. Other challenges included students consenting for simulations to be videotaped and ethical considerations of this. For example if one student in a group of eight did not consent, did this mean they missed the opportunity to undertake simulation, or that others in the group may be disadvantaged by being unable to review their performance. This has implications for freely given consent but also for equity of access to learning opportunities for students who wished to be taped and those who did not. Alongside this issue were the details behind data management, storage and access. Developing staff with varying levels of computer skills to use software and undertake a different approach to being the ‘teacher’ required innovation where we took an experiential approach. Considering explicit learning approaches to be trialled for learning was not a difficult proposition, but considering how to enact this as research with issues of blinding, timetabling of blinded groups, and reducing bias for testing results of different learning approaches along with gaining ethical approval was problematic. This presentation presents examples of these challenges and how we overcame them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital human models (DHM) have evolved as useful tools for ergonomic workplace design and product development, and found in various industries and education. DHM systems which dominate the market were developed for specific purposes and differ significantly, which is not only reflected in non-compatible results of DHM simulations, but also provoking misunderstanding of how DHM simulations relate to real world problems. While DHM developers are restricted by uncertainty about the user need and lack of model data related standards, users are confined to one specific product and cannot exchange results, or upgrade to another DHM system, as their previous results would be rendered worthless. Furthermore, origin and validity of anthropometric and biomechanical data is not transparent to the user. The lack of standardisation in DHM systems has become a major roadblock in further system development, affecting all stakeholders in the DHM industry. Evidently, a framework for standardising digital human models is necessary to overcome current obstructions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The primary objective of the paper is to make use of statistical digital human model to better understand the nature of reach probability of points in the taskspace. The concept of task-dependent boundary manikin is introduced to geometrically characterize the extreme individuals in the given population who would accomplish the task. For a given point of interest and task, the map of the acceptable variation in anthropometric parameters is superimposed with the distribution of the same parameters in the given population to identify the extreme individuals. To illustrate the concept, the task space mapping is done for the reach probability of human arms. Unlike the boundary manikins, who are completely defined by the population, the dimensions of these manikins will vary with task, say, a point to be reached, as in the present case. Hence they are referred to here as the task-dependent boundary manikins. Simulations with these manikins would help designers to visualize how differently the extreme individuals would perform the task. Reach probability at the points in a 3D grid in the operational space is computed; for objects overlaid in this grid, approximate probabilities are derived from the grid for rendering them with colors indicating the reach probability. The method may also help in providing a rational basis for selection of personnel for a given task.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EU]Dokumentu honek "Panpinan Egindako Bihotz-Biriketako Berpizte Maniobran Bularra Bere Onera Bueltatzearen Analisia" izena duen Gradu Amaierako Lanaren memoria eta eranskinak biltzen ditu. Bertan, lan horren bitartez lorturiko helburuak, horiek nola lortu diren eta burutu ahal izateko egin beharreko pausuak aurkezten dira. Bihotz-biriketako berpizterako berrelikadura gailuek berpizte maniobren kalitateari buruzko informazioa momentuan ematen dute. Proiektua berrelikadurarako laguntza gailuen parametroen kalitatea hobetzeko ikerlan bat egitera bideratuta dago, zehazki bularra bere onera bueltatzen den jakiteko metodoen azterketan sakontzen duelarik interesa duelarik. Alde batetik, benetako sakoneraren kalkulu zehatzari buruzko ikerketa bat egiten da, horretarako aukera ezberdinak aztertuz, metodo desberdinen analisia eginez. Bestetik, berrelikaduran zehar bularra bere onera bueltatzen den ohartarazteko (esate baterako, alarma sistema baten bitartez) parametroan egiten da ikerketa, horretarako indar sentsore gehigarri bat erabiliz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN]These feedback devices are used to improve the quality of chest compressions while performing CPR technique, as they provide real time information to guide the rescuer during resuscitation attempts. Most feedback systems on the market are based on accelerometers and additional sensors or reference signals, used for calculating the displacement of the chest from the acceleration signal. This makes them expensive and complex devices. With the aim of optimizing these feedback systems and overcoming their limitations, in this document we propose three alternative methods for calculating the depth of chest compressions. These methods differ from the ones existing so far in that they use exclusively the chest acceleration signal to compute the displacement. With their implementation, it would be possible to develop systems to provide accurate feedback more easily and economically. In this context, this document details the design and implementation of the three methods and the development of a software environment to analyze the accuracy of each of them and compare the results by means of a detailed calculation of errors. Furthermore, in order to evaluate the methods a database is required, and it can be compiled using a sensorized manikin to record the acceleration signal and the gold standard chest compression depth. The database generated will be used for other studies related to the estimation of the compression depth, because the signals obtained in the manikin platform are very similar to those recorded during a real resuscitation episode.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN]This paper presents a project within that research field. The project consists on the development of an experimental environment comprised by a sensorized practice manikin and a management software system. Manikin model allows the simulation of cardiac arrest episodes on laboratory settings. The management software system adds the capacity to compute and analyze the characteristics of the artifact induced on the electrocardiogram and the thoracic impedance signals by chest compressions during cardiopulmonary resuscitation due to variations of the electrode-skin interface. The main reason for choosing this kind of model is the impossibility to use real people because of the risk of thoracic injuries during chest compression. Moreover, this platform could be used for training in reanimation techniques for real situations. Even laypeople with minimal training can perform cardiopulmonary resuscitation. This can reduce the response time to an emergency while the healthcare personnel arrives, which is key to improve outcomes, since with every minute the chances of survival decrease approximately 10%. It is not necessary to have medical knowledge to perform cardiopulmonary resuscitation, which could increase chances of survival for a patient with an early reanimation since In this context, this paper details the technique solution for the manikin sensorisation to acquire the electrocardiogram, the impedance signal measured between the defibrillation pads placed on the patient’s chest, the compression depth, the compression force and the acceleration experienced by the chest in the three orthogonal axes. Moreover, it is possible to inject a previously recorded electrocardiogram signal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quality of cardiopulmonary resuscitation (CPR) improves through the use of CPR feedback devices. Most feedback devices integrate the acceleration twice to estimate compression depth. However, they use additional sensors or processing techniques to compensate for large displacement drifts caused by integration. This study introduces an accelerometer-based method that avoids integration by using spectral techniques on short duration acceleration intervals. We used a manikin placed on a hard surface, a sternal triaxial accelerometer, and a photoelectric distance sensor (gold standard). Twenty volunteers provided 60 s of continuous compressions to test various rates (80-140 min(-1)), depths (3-5 cm), and accelerometer misalignment conditions. A total of 320 records with 35312 compressions were analysed. The global root-mean-square errors in rate and depth were below 1.5 min(-1) and 2 mm for analysis intervals between 2 and 5 s. For 3 s analysis intervals the 95% levels of agreement between the method and the gold standard were within -1.64-1.67 min(-1) and -1.69-1.72 mm, respectively. Accurate feedback on chest compression rate and depth is feasible applying spectral techniques to the acceleration. The method avoids additional techniques to compensate for the integration displacement drift, improving accuracy, and simplifying current accelerometer-based devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth. Materials and Methods We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer's hands and the manikin's chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor. Results The median (IQR) percent error was 5.9% (2.8-10.3), 6.3% (2.9-11.3), and 2.5% (1.2-4.4) for depth and 1.7% (0.0-2.3), 0.0% (0.0-2.0), and 0.9% (0.4-1.6) for rate, respectively. Depth accuracy depended on the target rate (p < 0.001) and on the rescuer couple (p < 0.001) within each method. Conclusions Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper explores the cognitive functions of the Reality Status Evaluation (RSE) system in our experiences of narrative mediated messages (NMM) (fictional, narrative, audio-visual one-way input and moving picture messages), such as fictional TV programs and films. We regard reality in mediated experiences as a special mental and emotional construction and a multi-dimensional concept. We argue that viewers' reality sense in NMM is influenced by many factors with "real - on" as the default value. Some of these factors function as primary mental processes, including the content realism factors of those messages such as Factuality (F), Social Realism (SR), Life Relevance (LR), and Perceptual Realism - involvement (PR), which would have direct impacts on reality evaluations. Other factors, such as Narrative Meaning (NM), Emotional Responses, and personality trait Absorption (AB), will influence the reality evaluations directly or through the mediations of these main dimensions. I designed a questionnaire to study this theoretical construction. I developed items to form scales and sub-scales measuring viewers' subjective experiences of reality evaluations and these factors. Pertinent statistical techniques, such as internal consistency and factorial analysis, were employed to make revisions and improve the quality of the questionnaire. In the formal experiment, after viewing two short films, which were selected as high or low narrative structure messages from previous experiments, participants were required to answer the questionnaire, Absorption questionnaire, and SAM (Self-Assessment Manikin, measuring immediate emotional responses). Results were analyzed using the EQS, structural equation modeling (SEM), and discussed in terms oflatent relations among these subjective factors in mediated experience. The present results supported most of my theoretical hypotheses. In NMM, three main jactors, or dimensions, could be extracted in viewers' subjective reality evaluations: Social Realism (combining with Factuality), Life Relevance and Perceptual Realism. I designed two ways to assess viewers' understanding of na"ative meanings in mediated messages, questionnaire (NM-Q) and rating (NM-R) measurement, and its significant influences on reality evaluations was supported in the final EQS models. Particularly in high story stnlcture messages, the effect of Narrative Meaning (NM) can rarely be explained by only these dimensions of reality evaluations. Also, Empathy seems to playa more important role in RSE of low story structure messages. Also, I focused on two other factors that were pertinent to RSE in NMM, the personality trait Absorption, and Emotional Responses (including two dimensions: Valence and Intensity). Final model results partly supported my theoretical hypotheses about the relationships among Absorption (AB), Social Realism (SR) and Life Relevance (LR); and the immediate impact of Emotional Responses on Perceptual Realism cPR).