999 resultados para Magnetic search coil


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To describe spontaneous blink kinematics in Graves' upper eyelid retraction (UER).Methods: The magnetic search coil technique was used to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves' UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software.Results: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.7 for patients and of 20.0 +/- 2.1 for the controls (t = 2.58, P = 0.016). There were no statistically significant differences in blink amplitude between controls (22.7 +/- 3.1 degrees) and Graves' patients (24.7 +/- 3.3 degrees). However, while only 22% of the blinks performed by controls were smaller than MRD, this rate was 78% for patients. In addition, in blinks larger than 25, patients showed lower down-phase velocity than controls.Conclusions: Patients with Graves' UER show reduced blinks rates and abnormal blink kinematics, which might be related to the development of exposure keratitis in this disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. We quantified the main sequence of spontaneous blinks in normal subjects and Graves' disease patients with upper eyelid retraction using a nonlinear and two linear models, and examined the variability of the main sequence estimated with standard linear regression for 10-minute periods of time. Methods. A total of 20 normal subjects and 12 patients had their spontaneous blinking measured with the magnetic search coil technique when watching a video during one hour. The main sequence was estimated with a power-law function, and with standard and trough the origin linear regressions. Repeated measurements ANOVA was used to test the mean sequence stability of 10-minute bins measured with standard linear regression. Results. In 95% of the sample the correlation coefficients of the main sequence ranged from 0.60 to 0.94. Homoscedasticity of the peak velocity was not verified in 20% of the subjects and 25% of the patients. The power-law function provided the best main sequence fitting for subjects and patients. The mean sequence of 10-minute bins measured with standard linear regression did not differ from the one-hour period value. For the entire period of observation and the slope obtained by standard linear regression, the main sequence of the patients was reduced significantly compared to the normal subjects. Conclusions. Standard linear regression is a valid and stable approximation for estimating the main sequence of spontaneous blinking. However, the basic assumptions of the linear regression model should be examined on an individual basis. The maximum velocity of large blinks is slower in Graves' disease patients than in normal subjects. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To measure renal adenosine triphosphate (ATP) (bioenergetics) during hypotensive sepsis with or without angiotensin II (Ang II) infusion. Methods: In anaesthetised sheep implanted with a renal artery flow probe and a magnetic resonance coil around one kidney, we induced hypotensive sepsis with intravenous Escherichia coli injection. We measured mean arterial pressure (MAP), heart rate, renal blood flow RBF and renal ATP levels using magnetic resonance spectroscopy. After 2 h of sepsis, we randomly assigned sheep to receive an infusion of Ang II or vehicle intravenously and studied the effect of treatment on the same variables. Results: After E. coli administration, the experimental animals developed hypotensive sepsis (MAP from 92 ± 9 at baseline to 58 ± 4 mmHg at 4 h). Initially, RBF increased, then, after 4 h, it decreased below control levels (from 175 ± 28 at baseline to 138 ± 27 mL/min). Despite decreased RBF and hypotension, renal ATP was unchanged (total ATP to inorganic phosphate ratio from 0.69 ± 0.02 to 0.70 ± 0.02). Ang II infusion restored MAP but caused significant renal vasoconstriction. However, it induced no changes in renal ATP (total ATP to inorganic phosphate ratio from 0.79 ± 0.03 to 0.80 ± 0.02). Conclusions:During early hypotensive experimental Gram-negative sepsis, there was no evidence of renal bioenergetic failure despite decreased RBF. In this setting, the addition of a powerful renal vasoconstrictor does not lead to deterioration in renal bioenergetics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High magnification and large depth of field with a temporal resolution of less than 100 microseconds are possible using the present invention which combines a linear electron beam produced by a tungsten filament from an SX-40A Scanning Electron Microscope (SEM), a magnetic deflection coil with lower inductance resulting from reducing the number of turns of the saddle-coil wires, while increasing the diameter of the wires, a fast scintillator, photomultiplier tube, photomultiplier tube base, and signal amplifiers and a high speed data acquisition system which allows for a scan rate of 381 frames per second and 256.times.128 pixel density in the SEM image at a data acquisition rate of 25 MHz. The data acquisition and scan position are fully coordinated. A digitizer and a digital waveform generator which generates the sweep signals to the scan coils run off the same clock to acquire the signal in real-time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel design of a moving-coil transducer coupled with a low-hardness elastomer called “the gel surround” is presented in this thesis. This device is termed a “gel-type audio transducer”. The gel-type audio transducer has been developed to overcome the problems that conventional loudspeakers have suffered - that is, the problem with size of the audio device against the quality of sound at low frequency range. Therefore the research work presented herein aims to develop the “gel-type audio transducer” as a next-generation audio transducer for miniaturized woofers. The gel-type audio transducer consists of the magnetic and coil-drive plate assembly, and these parts are coupled by the gel surround. The transducer is driven by the electromagnetic conversion mechanism (a moving-coil transducer) and its output driving force can be greatly enhanced by applying the novel mechanism of the gel surround especially at low frequency range, resulting in the enhanced acoustic efficiency. The transducer can be attached to a stiff and light panel with both the optimized impedance matching and minimised wave collisions. The performance of the gel-type audio transducer is greatly influenced by the mass of the magnetic assembly and compliance of the “gel surround”. But as the size of the magnet and its weight have to be kept minimal for a miniaturisation of the device, the focus of the research is on the effect of the of the gel surround. As a result, the effect of the gel surround, made of the RTV (room-temperature vulcanising) silicone elastomer, TPE (thermoplastic elastomer), and the silicone foam, on generation of the output driving force, the energy transfer from the transducer to a panel to which the transducer is attached, and sound radiation from the vibrating panel, was investigated. This effect was studied by COMSOL multiphysics (FE analysis) and thereby, the simulated results were verified by experiments such as the laser scanning measurement, DMA (dynamic mechanical analyzer), and the acoustic test. Successful development of prototypes of the gel-type audio transducers, with an enhanced acoustic efficiency at reduced size and weight, was achieved. Implementation of the transducers into consumer applications was also demonstrated with their commercial values.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nas últimas décadas, a prospecção por métodos eletromagnéticos vem-se constituindo numa técnica eficiente para prospecção mineral. O objetivo deste trabalho foi desenvolver um equipamento para prospecção eletromagnética quantitativa de corpos condutores, através do método dipolo-dipolo, podendo ainda ser usado em modelos reduzidos. Eletricamente, o sistema mede grandezas relacionadas ao acoplamento indutivo entre duas bobinas: transmissora e receptora. Elas são dispostas na superfície da terra, afastadas entre si, e a terra, desse modo, constitui o núcleo acoplador. Quando existem corpos condutores nas proximidades, estes são denunciados por alterações no comportamento do sinal induzido na bobina receptora. O equipamento compreende dois conjuntos: o transmissor e o receptor, além de acessórios. O transmissor gera um campo eletromagnético nas freqüências de 520 e 3.090 Hz, e um sinal de referência para o receptor, o qual é enviado através de um cabo. O receptor, inicialmente, separa o sinal induzido pelos campos secundários gerados por condutores, do campo normalmente recebido, quando a condutividade da subsuperfície é relativamente uniforme (campo primário). Em seguida, decompõe esse sinal em duas componentes ortogonais, uma em fase, e outra em quadratura com o campo primário. Através de duas escalas de precisão, as amplitudes dessas componentes são mostradas como percentagens do campo primário, com precisão de 1%. A sensibilidade do receptor é de 0,5 μV. O circuito eletrônico foi rigorosamente testado com preciso instrumental de laboratório. Em seguida, testou-se sua aplicação no Laboratório de Modelo Reduzido Eletromagnético do NCGG, refazendo-se experiências clássicas, encontradas na literatura especializada. No campo, foi experimentado próximo da cidade de Araci no Estado da Bahia, em áreas prospectadas pela "Rio Doce Geologia e Mineração S/A-DOCEGEO". Em ambos os casos, verificaram-se bons resultados.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes the use of high-power thyristors in conjunction with a low-voltage supply for generating pulsed magnetic fields. A modular bank of electrolytic capacitors is charged through a programmable solid-state power supply and then rapidly discharged through a bank of thyristors into a magnetizing coil. The modular construction of capacitor banks enables the discrete control of pulse energy and time. Peak fields up to 15 telsa (150 KOe) and a half period of about 200 microseconds are generated through the discharges. Still higher fields are produced by discharging into a precooled coil ( 77°K). Measurement method for a pulsed field is described.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High-temperature superconductors have created the opportunity for a step change in the technology of power applications. Racetrack superconducting coils made from YBCO coated conductors have been used in several engineering applications including SMES, rotor or stator windings of electric machines. AC loss is one of the most important factors that determine the design and performance of superconducting devices. In this paper, a numerical model is developed to calculate the AC losses in superconducting racetrack coils in different magnetic conditions. This paper first discusses the AC losses of the coils in self-field or external field only. It then goes to investigate the AC losses of the coils being exposed to AC ripple field and a DC background field. Finally, the AC losses of the coils carrying DC current and being exposed to AC field are calculated. These two scenarios correspond to using superconducting coils as the rotor field winding of an electric machine. © 2010 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A measurement system for magnetic fields or electric currents uses a single-core fluxgate, magneto-inductive or magneto-impedance device driven from a radio frequency excitation source. Flux nulling feedback circuitry is provided to maintain the core of the sensor at substantially zero net flux and improve the linearity and dynamic response of the sensor system. A high pass filter is provided for reducing the dc effects of the ohmic resistance of the coil and lead wires on the effectiveness of the flux nulling feedback.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A finite element model for a YBCO pancake coil with a magnetic substrate is developed in this paper. An axial symmetrical H formulation and the E-J power law are used to construct the model, with the magnetic substrate considered by introducing an extra time-dependent term in the formula. A pancake coil is made and tested. The measurement of critical current and transport loss is compared to the model result, showing good consistency. The influence of magnetic substrate in the condition of AC and DC current is studied. The AC loss decreases without a magnetic substrate. It is observed that when the applied DC current approaches the critical current the coil turn loss profile changes completely in the presence of magnetic substrate due to the change of magnetic field distribution. © 2012 IOP Publishing Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A high temperature superconducting magnetic energy storage device (SMES) has been realised using a 350 m-long BSCCO tape wound as a pancake coil. The coil is mounted on a cryocooler allowing temperatures down to 17.2 K to be achieved. The temperature dependence of coil electrical resistance R(T) shows a superconducting transition at T 102.5 K. Measurements of the V(I) characteristics were performed at several temperatures between 17.2 K and 101.5 K to obtain the temperature dependence of the critical current (using a 1 νV/cm criterion). Critical currents were found to exceed 100 A for T < 30 K. An electronic DC-DC converter was built in order to control the energy flow in and out of the superconducting coil. The converter consists of a MOS transistor bridge switching at a 80 kHz frequency and controlled with standard Pulse Width Modulation (PWM) techniques. The system was tested using a 30 V squared wave power supply as bridge input voltage. The coil current, the bridge input and output voltages were recorded simultaneously. Using a 10 A setpoint current in the superconducting coil, the whole system (coil + DC-DC converter) can provide a stable output voltage showing uninterruptible power supply (UPS) capabilities over 1 s. © 2006 IOP Publishing Ltd.