955 resultados para Macular thickness


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report describes the presence of bilateral macular atrophy in a patient with Alport syndrome and compares this finding with literature. At fundoscopy, there was a discrete circumscribed macular thinning showing intense retinal pigment epithelium color and the presence of whitish circular retinal lesions ("dots" and "flecks") at nasal mid periphery of both eyes. Optical coherence tomography showed bilateral partial atrophy of the neurosensory retina in the macula, with a greater extent in the temporal region. This case describes a rare ophthalmological finding in Alport syndrome and important to be recognized for a precise diagnosis as well as for determining visual prognosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although several postmortem findings in the retina of patients with Alzheimer's disease (AD) are available, new biomarkers for early diagnosis and follow-up of AD are still lacking. It has been postulated that the defects in the retinal nerve fiber layer (RNFL) may be the earliest sign of AD, even before damage to the hippocampal region that affects memory. This fact may reflect retinal neuronal-ganglion cell death and axonal loss in the optic nerve in addition to aging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose To examine macular retinal thickness and retinal layer thickness with spectral domain optical coherence tomography (OCT) in a population of children with normal ocular health and minimal refractive errors. Methods High resolution macular OCT scans from 196 children aged from 4 to 12 years (mean age 8 ± 2 years) were analysed to determine total retinal thickness and the thickness of 6 different retinal layers across the central 5 mm of the posterior pole. Automated segmentation with manual correction was used to derive retinal thickness values. Results The mean total retinal thickness in the central 1 mm foveal zone was 255 ± 16 μm, and this increased significantly with age (mean increase of 1.8 microns per year) in childhood (p<0.001). Age-related increases in thickness of some retinal layers were also observed, with changes of highest statistical significance found in the outer retinal layers in the central foveal region (p<0.01). Significant topographical variations in thickness of each of the retinal layers were also observed (p<0.001). Conclusions Small magnitude, statistically significant increases in total retinal thickness and retinal layer thickness occur from early childhood to adolescence. The most prominent changes appear to occur in the outer retinal layers of the central fovea.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this systematic review is to appraise the evidence for the use of anti-VEGF drugs and steroids in diabetic macular oedema (DMO) as assessed by change in best corrected visual acuity (BCVA), central macular thickness and adverse events

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJETIVOS: Comparar las medidas de grosor macular, medido por HD-OCT Cirrus®, en pacientes de la Fundación Oftalmológica Nacional con miopía baja y alta. MÉTODOS: Estudio transversal analítico, en el que se incluyeron pacientes con miopía alta, definida como defecto esférico mayor a – 6.0 dioptrías (D), y pacientes con miopía baja, definida como defecto esférico entre -1.00 D y -6.00 D; a los que se le realizó mapa de grosores maculares con el HD-OCT Cirrus®, y se compararon las medias de los grosores (1, 3 y 6 mm). RESULTADOS: Un total de 128 ojos de pacientes entre 12 y 80 años fueron incluidos; 64 ojos en grupo de miopes bajos y 64 ojos en grupo de miopes altos. La media de edad fue: 37.3 y 38.4 años, y el defecto esférico promedio fue de 2.2 D y 11.5 D, respectivamente. El promedio de grosores en mácula interna (319.9 vs. 307.87 micras, P=0.002), y mácula externa (276.08 vs. 270.23 micras, P=0.047) fue significativamente mayor en el grupo de miopía baja que en el de miopía alta. Sin embargo la media del grosor macular central (1 mm) no tuvo diferencia (261.25 vs. 262 micras P=0.891). CONCLUSIÓN: Este estudio muestra que el grosor macular de 3 y 6 mm centrales es más delgado en miopes altos, pero en 1 mm central es similar que en miopes bajos. En los pacientes estudiados no se encontró diferencia en grosores maculares según género o subgrupos de edad.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE. To compare the effectiveness of posterior sub-Tenon's infusion (STi) and intravitreal injection (IVI) of triamcinolone acetonide (TA) for treatment of refractory diffuse diabetic macular edema.METHODS. Thirty-six phakic diabetic patients with refractory diffuse diabetic macular edema were prospectively enrolled. Patients randomly received either 40 mg STi or 4 mg IVI of TA. Comprehensive ophthalmic evaluation was performed at baseline and 1, 2, 4, 8 +/- 1, 12 +/- 2 and 24 +/- 2 weeks after treatment. Macular morphologic changes detected by optical coherence tomography and visual acuity, intraocular pressure, and lens status were evaluated.RESULTS. Twenty-eight patients (28 eyes) completed the 24-week study. Central macular thickness was significantly reduced in the IVI group when compared with the STi group at 2, 4, 8, 12, and 24 weeks after treatment (P < 0.01). Mean visual acuities (in logarithm of the minimum angle of resolution [logMAR]) at week-4, -8, and -12 follow-up examinations were significantly higher in the IVI group (0.74, 0.75, and 0.82, respectively) when compared with the STi group (0.88, 0.88, and 0.90, respectively; P < 0.01). A significant change from baseline in mean intraocular pressure (mm Hg) was seen at weeks 4 (+/- 3.21) and 8 (+/- 3.35) in STi the group (P < 0.01), and at week 8 (+/- 2.78) in the IVI group (P < 0.05). No patient had cataract progression during the study.CONCLUSIONS. Although the number of patients and length of follow-up in this preliminary study were limited, the changes in central macular thickness and visual acuity observed after treatment suggest that IVI TA may be more effective than STi for the management of refractory diffuse diabetic macular edema. Further studies are needed to confirm these preliminary findings.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background/aims: The aim of this study was to compare the morphological and visual acuity outcomes associated with a single intravitreal injection of triamcinolone acetonide versus bevacizumab for the treatment of refractory diffuse diabetic macular oedema.Methods: Twenty-eight patients were randomly assigned to receive a single intravitreal injection of either 4 mg/0.1 ml triamcinolone acetonide or 1.5 mg/0.06 ml bevacizumab. Comprehensive ophthalmic evaluation was performed at baseline and at weeks 1, 4, 8 (+/- 1), 12 (+/- 2) and 24 (+/- 2) after treatment. Main outcome measures included central macular thickness measured with optical coherence tomography (OCT) and best corrected Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity.Results: Twenty-six patients (26 eyes) completed all study visits (two patients missed two consecutive study visits). Central macular thickness was significantly reduced in the intravitreal triamcinolone group compared with the bevacizumab group at weeks 4, 8, 12 and 24 (p<0.05). Logarithm of the minimum angle of resolution (LogMAR) best-corrected visual acuity was significantly higher at weeks 8 (0.69; similar to 20/100(+1)) and 12 (0.74; 20/100(-2)) in the intravitreal triamcinolone group compared with the bevacizumab group (weeks 8 (0.83; similar to 20/125(-1)) and 12 (0.86; 20/ 160(+2))) (p<0.05). Significant change from baseline in mean intraocular pressure (mmHg) was seen at week 4 (+2.25) only in the intravitreal triamcinolone group (p<0.0001). No patient had observed cataract progression during the study.Conclusions: One single intravitreal injection of triamcinolone may offer certain advantages over bevacizumab in the short-term management of refractory diabetic macular oedema, specifically with regard to changes in central macular thickness. The actual clinical relevance of our preliminary findings, however, remains to be determined in future larger studies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of a single intravitreal bevacizumab injection on visual acuity, contrast sensitivity and optical coherence tomography-measured central macular thickness in eyes with macular edema from branch retinal vein occlusion. Methods: Seventeen eyes of 17 patients with macular edema from unilateral branch retinal vein occlusion were treated with a single bevacizumab injection. Patients were submitted to a complete evaluation including best corrected visual acuity, contrast sensitivity and optical coherence tomography measurements before treatment and one and three months after injection. Visual acuity, contrast sensitivity and optical coherence tomography measurements were compared to baseline values. Results: Mean visual acuity measurement improved from 0.77 logMAR at baseline to 0.613 logMAR one month after injection (P=0.0001) but worsened to 0.75 logMAR after three months. Contrast sensitivity test demonstrated significant improvement at spatial frequencies of 3, 6, 12 and 18 cycles/degree one month after injection and at the spatial frequency of 12 cycles/degree three months after treatment. Mean +/- standard deviation baseline central macular thickness (552 +/- 150 mu m) reduced significantly one month (322 +/- 127 mu m, P=0.0001) and three months (439 perpendicular to 179 mu m, P=0.01) after treatment. Conclusions: Bevacizumab injection improves visual acuity and contrast sensitivity and reduces central macular thickness one month after treatment. Visual acuity returns to baseline levels at the 3-month follow-up, but some beneficial effect of the treatment is still present at that time, as evidenced by optical coherence tomography-measured central macular thickness and contrast sensitivity measurements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To investigate macular thickness and visual acuity changes after 1 intravitreal injection of 0.5-mg ranibizumab during phacoemulsification cataract surgery in eyes with diabetic macular edema refractory to laser treatment. Methods: Eleven eyes of 11 patients with diabetic macular edema refractory to modified Early Treatment Diabetic Retinopathy Study laser therapy received intravitreal during phacoemulsification cataract surgery. Comprehensive ophthalmic evaluation was performed preoperatively and at 1, 4, 8 +/- 1, and 12 +/- 2 weeks postoperatively. Main outcome measures included central subfield thickness and best-corrected Early Treatment Diabetic Retinopathy Study visual acuity. Results: Eleven patients completed the 12-week study visit. Mean central subfield thickness (+/- SEM) was 399.82 +/- 29.50 mu m at baseline and did not change significantly at any postoperative study visit (P > 0.05). Mean (+/- SEM) best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was 0.95 +/- 0.13 logarithm of the minimum angle of resolution (20/200) at baseline and was significantly improved at Weeks 1 (0.38 +/- 0.13), 4 (0.38 +/- 0.11), 8 (0.35 +/- 0.08), and 12 (0.46 +/- 0.12) after treatment (P < 0.05). Conclusion: In this case series of patients with diabetic macular edema refractory to laser therapy, intravitreal ranibizumab administered during cataract surgery was associated with no significant change in central subfield thickness postoperatively. Significant improvement in best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was observed after treatment, likely because of cataract removal. RETINA 32:1799-1803, 2012

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Visual symptoms are common in Parkinson's disease with studies consistently demonstrating reductions in visual acuity, contrast sensitivity, colour and motion perception as well as alterations in electroretinogram latencies and amplitudes. Optical coherence tomography can examine retinal structure non-invasively and retinal thinning has been suggested as a potential biomarker for neurodegeneration in Parkinson's disease. Our aim was to examine the retinal thickness of a cohort of Parkinson's disease subjects (and age-matched controls) to establish the practical utility of optical coherence tomography in a representative older Parkinson's disease group. METHODS: Fifty-one established Parkinson's disease subjects and 25 healthy controls were subjected to ophthalmological assessment and optical coherence tomography (Zeiss Stratus 3000™) of macular thickness and volume and retinal nerve fibre thickness around the optic nerve head. Twenty four percent of control and 20% of Parkinson's disease subjects were excluded from final analysis due to co-morbid ocular pathology. Further data was excluded either due to poor tolerability of optical coherence tomography or poor quality scans. RESULTS: Despite a reduction in both visual acuity and contrast sensitivity in the residual evaluable Parkinson's disease cohort, we did not detect any differences between the two study groups for any measures of retinal thickness, in contrast to previously published work. CONCLUSIONS: In addition to technical problems inherent in the evaluation, the lack of difference between Parkinson's disease and healthy control subjects suggests longitudinal studies, employing newer techniques, will be required to define the role of optical coherence tomography as a potential diagnostic biomarker.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Age-related macular degeneration and cataract are very common causes of visual impairment in the elderly. Macular pigment optical density is known to be a factor affecting the risk of developing age-related macular degeneration but its behaviour due to light exposure to the retina and the effect of macular physiology on this measurement are not fully understood. Cataract is difficult to grade in a way which reflects accurately the visual status of the patient. A new technology, optical coherence tomography, which allows a cross sectional slice of the crystalline lens to be imaged has the potential to be able to provide objective measurements of cataract which could be used for grading purposes. This thesis set out to investigate the effect of cataract removal on macular pigment optical density, the relationship between macular pigment optical density and macular thickness and the relationship between cortical cataract density as measured by optical coherence tomography and other measures of cataract severity. These investigations found: 1) Macular pigment optical density in a pseudophakic eye is reduced when compared to a fellow eye with age related cataract, probably due to differences in light exposure between the eyes. 2) Lower macular pigment optical density is correlated with thinning of the entire macular area, but not with thinning of the fovea or central macula. 3) Central macular thickness decreases with age. 4) Spectral domain optical coherence tomography can be used to successfully acquire images of the anterior lens cortex which relate well to slit lamp lens sections. 5) Grading of cortical cataract with spectral domain optical coherence tomography instruments using a wavelength of 840nm is not well correlated with other established metrics of cataract severity and is therefore not useful as presented as a grading method for this type of cataract.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objetivo: Evaluar mediante tomografía de coherencia óptica (OCT) las variaciones de espesor macular producidas a lo largo del tiempo en ojos pseudoafáquicos implantados con una lente intraocular (LIO) transparente en comparación con sus respectivos ojos contralarerales implantados con LIO amarilla. Métodos: El espesor macular de 36 ojos de 18 sujetos fue evaluado mediante OCT. Los sujetos presentaban edades superiores a 65 años y habían sido intervenidos de cataratas en ambos ojos en 2 cirugías independientes. La principal característica de los individuos es que llevaban implantada una LIO con diferente absorción en cada ojo: transparente (absorbente de la radiación ultravioleta) y amarilla (con filtro adicional absorbente de las radiaciones violeta-azul del espectro visible). El espesor macular se evaluó en 2 sesiones separadas en el tiempo por un intervalo de tiempo de 5 años, mediante el sistema Stratus-OCT (protocolo fast macular thickness). Se analizaron estadísticamente las diferencias en la evolución del espesor macular entre ojos con diferente tipo de LIO. Resultados: Tras 5 años de seguimiento, se observó que los ojos implantados con LIO transparente manifestaban una reducción del espesor macular estadísticamente significativa, superior a la esperada por el aumento de la edad. Sin embargo, los ojos implantados con LIOs amarillas mantuvieron su espesor macular estable. La disminución del espesor macular promedio en ojos implantados con LIO transparente fue de 5 ± 8 μm (p = 0,02) y la reducción del espesor foveal fue de 10 ± 17 μm (p = 0,02). Conclusiones: Los cambios de espesor macular producidos en ojos implantados con una LIO amarilla difieren de los cambios manifestados en ojos con LIO transparente. Estas observaciones apuntan a un posible efecto protector de las LIOs amarillas contra los efectos dañinos de la luz en sujetos pseudoafáquicos. Sin embargo, estudios con un mayor tamaño muestral y mayor tiempo de seguimiento son necesarios para confirmar que la protección inducida por este tipo de LIO es clínicamente significativa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE:

To determine the test-retest variability in perimetric, optic disc, and macular thickness parameters in a cohort of treated patients with established glaucoma.

PATIENTS AND METHODS:

In this cohort study, the authors analyzed the imaging studies and visual field tests at the baseline and 6-month visits of 162 eyes of 162 participant in the Glaucoma Imaging Longitudinal Study (GILS). They assessed the difference, expressed as the standard error of measurement, of Humphrey field analyzer II (HFA) Swedish Interactive Threshold Algorithm fast, Heidelberg retinal tomograph (HRT) II, and retinal thickness analyzer (RTA) parameters between the two visits and assumed that this difference was due to measurement variability, not pathologic change. A statistically significant change was defined as twice the standard error of measurement.

RESULTS:

In this cohort of treated glaucoma patients, it was found that statistically significant changes were 3.2 dB for mean deviation (MD), 2.2 for pattern standard deviation (PSD), 0.12 for cup shape measure, 0.26 mm for rim area, and 32.8 microm and 31.8 microm for superior and inferior macular thickness, respectively. On the basis of these values, it was estimated that the number of potential progression events detectable in this cohort by the parameters of MD, PSD, cup shape measure, rim area, superior macular thickness, and inferior macular thickness was 7.5, 6.0, 2.3, 5.7, 3.1, and 3.4, respectively.

CONCLUSIONS:

The variability of the measurements of MD, PSD, and rim area, relative to the range of possible values, is less than the variability of cup shape measure or macular thickness measurements. Therefore, the former measurements may be more useful global measurements for assessing progressive glaucoma damage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.