934 resultados para Mach-Zehnder interferometer (MZI)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A planar lightwave circuit (PLC) add-drop filter is proposed and analyzed, which consists of a symmetric Mach-Zehnder interferometer (MZI) combined with double microring resonators. A critical coupling condition is derived for a better box-like drop spectrum. Comparisons of its characteristics with other schemes, such as a MZI with a single ring resonator, arepresented, and some of the issues about device design and fabrication are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A discretely tunable Er-doped fiber-ring laser using a fiber Mach-Zehnder interferometer (MZI) and a tunable fiber Bragg grating (FBG) is proposed. In this scheme, the combination of MZI and FBG acts as a discrete wavelength selector. Analysis of its transmission function shows that discrete wavelength tuning can be realized, and experiments demonstrate 64 single-mode outputs with a mode spacing of 181.7 pm, and the output power is quite stable in the whole tuning range. (C) 2009 Wiley Periodicals, Inc. Microwave Opt Technol Lett 51 2595-2598, 2009; Published online in Wiley InterScience (www. interscience.wiley.com). DOI 10.1002/mop.24690

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on silicon-on-insulator (SOI) technology, a Mach-Zehnder interferometer (MZI) is fabricated, in which two directional couplers serve as power splitter and combiner. The free carrier plasma dispersion effect of Si is adopted to achieve the phase modulation and the consequent intensity modulation of optical fields. The device presents an insertion loss of 2.61 dB and an extinction ratio of 19.6 dB. The rise time and fall time are 676 ns and 552 ns, respectively. Detailed analysis and explanation of the performance behaviors are also presented. (c) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we propose and experimentally demonstrate a novel technique to generate ultrawideband (UWB) doublet pulses by exploiting the cross-phase modulation (XPM) in a semiconductor optical amplifier (SOA). The key component in the proposed system consists on an integrated SOA Mach-Zehnder interferometer (MZI) pumped with a Gaussian pulse modulated optical carrier. The transfer function of the nonlinear conversion process leads to the generation of UWB doublet pulses through the control of the biasing point of the SOA-MZI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Differential Phase Shift Keying (DPSK) modulation format has been shown as a robust solution for next-generation optical transmission systems. One key device enabling such systems is the delay interferometer, converting the signal phase information into intensity modulation to be detected by the photodiodes. Usually, Mach-Zehnder interferometer (MZI) is used for demodulating DPSK signals. In this paper, we developed an MZI which is based on all-fiber Multimode Interference (MI) structure: a multimode fiber (MMF) located between two single-mode fibers (SMF) without any transition zones. The standard MZI is not very stable since the two beams go through two different paths before they recombine. In our design the two arms of the MZI are in the same fiber, which will make it less temperature-sensitive than the standard MZI. Performance of such MZI will be analyzed from transmission spectrum. Finally such all-fiber MI-based MZI (MI-MZI) is used to demodulate 10 Gbps DPSK signals. The demodulated signals are analyzed from eye diagram and bit error rate (BER).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research the recovery of a DQPSK signal will be demonstrated using a single Mach-Zehnder Interferometer (MZI). By changing the phase delay in one of the arms it will be shown that different delays will produce different output levels. It will also be shown that with a certain level of phase shift the DQPSK signal can be converted into four different equally spaced optical power levels. With each decoded level representing one of the four possible bit permutations. By using this additional phase shift in one of the arms the number of MZIs required for decoding can be reduced from two to one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An approach to realizing simultaneous measurement of refractive index (RI) and temperature based on a microfiber-based dual inline Mach-Zehnder interferometer (MZI) is proposed and demonstrated. Due to different interference mechanisms, as one interference between the core mode and the lower order cladding mode in the sensing single-mode fiber and the other interference between the fundamental mode and the high-order mode in the multimode microfiber, the former interferometer achieves RI sensitivity of -23.67 nm/RIU and temperature sensitivity of 81.2 pm/oC, whereas those of the latter are 3820.23 nm/RIU, and -465.7 pm/oC, respectively. The large sensitivity differences can provide a more accurate demodulation of RI and temperature. The sensor is featured with multiparameters measurement, compact structure, high sensitivity, low cost, and easy fabrication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multimode microfiber (MMMF)-based dual Mach-Zehnder interferometer (MZI) is proposed and demonstrated for simultaneous measurement of refractive index (RI) and temperature. By inserting a section of MMMFsupporting a few modes in the sensing arm of the MZI setup, an inline interference between the fundamental mode and the high-order mode of MMMF, as well as the interference between the high-order mode of MMMF and the reference arm, i.e., the dual MZI, is realized. Due to different interference mechanisms, the former interferometer achieves RI sensitivity of 2576.584 nm/RIU and temperature sensitivity of 0.193 nm/°C, while the latter one achieves RI sensitivity of 1001.864 nm/RIU and temperature sensitivity of 0.239 nm/°C, demonstrating the ability to attain highly accurate multiparameter measurements. © 2014 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optical interference method is a promising technique for measuring temperature, density, and concentration in fluids. The non-intrusive and non-invasive nature of its optical techniques to the measured section are its most outstanding features. However, the adverse experiment environment, especially regarding shaking and vibrating, greatly restricts the application of the interferometer. In the present work, an optical diagnostic system consisting of a Mach-Zehnder interferometer (named after physicists Ludwig Mach) and an image processor has been developed that increases the measuring sensitivity compared to conventional experimental methods in fluid mechanics. An image processor has also been developed for obtaining quantitative results by using Fourier transformation. The present facility has been used in observing and measuring the mass transfer process of a water droplet in EAFP protein solution under microgravity condition provided by the satellite Shi Jian No. 8.