913 resultados para Mach-Zehnder interferometer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development and fabrication of a thermo-electro-optic sensor using a Mach-Zehnder interferometer and a resistive micro-heater placed in one of the device`s arms is presented. The Mach-Zehnder structure was fabricated on a single crystal silicon substrate using silicon oxynitride and amorphous hydrogenated silicon carbide films to form an anti-resonant reflective optical waveguide. The materials were deposited by Plasma enhanced chemical vapor deposition technique at low temperatures (similar to 320 degrees C). To optimize the heat transfer and increase the device response with current variation, part of the Mach-Zehnder sensor arm was suspended through front-side bulk micromachining of the silicon substrate in a KOH solution. With the temperature variation caused by the micro-heater, the refractive index of the core layer of the optical waveguide changes due to the thermo-optic effect. Since this variation occurs only in one of the Mach-Zehnder`s arm, a phase difference between the arms is produced, leading to electromagnetic interference. In this way, the current applied to the micro-resistor can control the device output optical power. Further, reactive ion etching technique was used in this work to define the device`s geometry, and a study of SF6 based etching rates on different composition of silicon oxynitride films is also presented. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract (deutsch)Zielsetzung des Dissertationsvorhabens war die Beobachtung und Analyse von Gast-Wirt-Wechselwirkungen an oxidischen Oberflächen. Einer der Wechselwirkungspartner sollte dabei auf der Oberfläche immobilisiert, der andere in wäßriger Lösung darüber vorliegen.Eine empfindliche und oberflächensensitive Methode zur Beobachtung der Anlagerung unmarkierter Moleküle ist die Wellenleiterspektroskopie, insbesondere mit dem hier verwendeten und weiterentwickelten integriert-optischen Mach-Zehnder-Interferometer in Siliziumtechnik (Siliziumoxynitrid auf oxidiertem Siliziumwafer). Mit Hilfe des Interferometers wurden unterschiedliche Wirt-Gast-Systeme untersucht. Grundlage der Immobilisierung war jeweils die Funktionalisierung der Sensoroberfläche durch Selbstadsorption von Organosilanen. Durch unterschiedliche Organosilane, die zum Teil im Rahmen dieser Arbeit synthetisiert wurden, ließen sich die Wirtmoleküle beta-Cyclodextrin, Streptavidin, sowie unterschiedliche monoklonale Antikörperfragmente immobilisieren.- Der Einfluß der Oberfläche auf die Bindungsstärke des Wirtmoleküls beta-Cyclodextrin und unterschiedlicher Gastmoleküle wurde konzentrationsabhängig untersucht.- Silan-Biotinderivate mit unterschiedlicher Streptavidin-Affinität wurden an die Oberfläche immobilisiert und die Adsorption von Streptavidin an die Biotinderivate beobachtet. Dabei konnte unter anderem nachgewiesen werden, daß das Streptavidinadsorbat gequollen ist.- Als mögliche Anwendung wurde geprüft, ob das vorgestellte Interferometer durch die Funktionalisierung mit Antikörperfragmenten als Biosensor in Frage kommt. Es konnte nachgewiesen werden, daß sich Antikörper auf der Sensoroberfläche immobilisieren lassen und Antigene spezifisch an diese Antikörper adsorbieren.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a novel method to generate ultrawideband (UWB) doublets is proposed and experimentally demonstrated, which is based on exploiting the cross-phase modulation in a semiconductor optical amplifier (SOA). The key component is an integrated SOA Mach-Zehnder interferometer pumped with an optical carrier modulated by a Gaussian pulse. The transfer function of the nonlinear conversion process leads to the generation of UWB doublet pulses by tuning the SOA currents to different values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we propose and experimentally demonstrate a novel technique to generate ultrawideband (UWB) doublet pulses by exploiting the cross-phase modulation (XPM) in a semiconductor optical amplifier (SOA). The key component in the proposed system consists on an integrated SOA Mach-Zehnder interferometer (MZI) pumped with a Gaussian pulse modulated optical carrier. The transfer function of the nonlinear conversion process leads to the generation of UWB doublet pulses through the control of the biasing point of the SOA-MZI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Differential Phase Shift Keying (DPSK) modulation format has been shown as a robust solution for next-generation optical transmission systems. One key device enabling such systems is the delay interferometer, converting the signal phase information into intensity modulation to be detected by the photodiodes. Usually, Mach-Zehnder interferometer (MZI) is used for demodulating DPSK signals. In this paper, we developed an MZI which is based on all-fiber Multimode Interference (MI) structure: a multimode fiber (MMF) located between two single-mode fibers (SMF) without any transition zones. The standard MZI is not very stable since the two beams go through two different paths before they recombine. In our design the two arms of the MZI are in the same fiber, which will make it less temperature-sensitive than the standard MZI. Performance of such MZI will be analyzed from transmission spectrum. Finally such all-fiber MI-based MZI (MI-MZI) is used to demodulate 10 Gbps DPSK signals. The demodulated signals are analyzed from eye diagram and bit error rate (BER).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Photocopy (positive) made in 1963 by the Library of Congress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dibit recovery of a DQPSK signal will be demonstrated using a single Mach Zehnder Interferometer, containing a 1-bit delay, and a single balanced receiver. The electrical output levels of the balanced receiver are dependent upon the relative phase delay between the arms of the Mach Zehnder Interferometer. This paper will investigate this characteristic when the input signal is DQPSK modulated. It will also be shown that with a certain amount of phase shift the DQPSK signal can be converted into four different equally spaced electrical signal levels. With each decoded level representing one of the four possible dibits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this research the recovery of a DQPSK signal will be demonstrated using a single Mach-Zehnder Interferometer (MZI). By changing the phase delay in one of the arms it will be shown that different delays will produce different output levels. It will also be shown that with a certain level of phase shift the DQPSK signal can be converted into four different equally spaced optical power levels. With each decoded level representing one of the four possible bit permutations. By using this additional phase shift in one of the arms the number of MZIs required for decoding can be reduced from two to one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A low cost interrogation scheme is demonstrated for a refractometer based on an in-line fiber long period grating (LPG) Mach–Zehnder interferometer. Using this interrogation scheme the minimum detectable change in refractive index of ?n ~ 1.8×10-6 is obtained, which is the highest resolution achieved using a fiber LPG device, and is comparable to precision techniques used in the industry including high performance liquid chromatography and ultraviolet spectroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical first order calculation of the impact of Gaussian white noise on a novel single Mach-Zehnder Interferometer demodulation scheme for DQPSK reveals a constant Q factor ratio to the conventional scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An optical liquid-level sensor (LLS) based on a long-period fiber grating (LPG) interferometer is proposed and experimentally demonstrated. Two identical 3-dB LPGs are fabricated to form an in-fiber Mach-Zehnder interferometer, and the fiber portion between two LPGs is exposed to the liquid as the sensing element. The sensitivity and measurement range of the sensors employing different orders of cladding modes are investigated both theoretically and experimentally. The experimental results show good linearity and large measurement range. One of the significant advantages of such a sensing structure is that the measurement level is not limited to the length of the LPG itself. Also, the measurement range and sensitivity of the proposed LLS can be readily tailored for a particular applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An approach to realizing simultaneous measurement of refractive index (RI) and temperature based on a microfiber-based dual inline Mach-Zehnder interferometer (MZI) is proposed and demonstrated. Due to different interference mechanisms, as one interference between the core mode and the lower order cladding mode in the sensing single-mode fiber and the other interference between the fundamental mode and the high-order mode in the multimode microfiber, the former interferometer achieves RI sensitivity of -23.67 nm/RIU and temperature sensitivity of 81.2 pm/oC, whereas those of the latter are 3820.23 nm/RIU, and -465.7 pm/oC, respectively. The large sensitivity differences can provide a more accurate demodulation of RI and temperature. The sensor is featured with multiparameters measurement, compact structure, high sensitivity, low cost, and easy fabrication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multimode microfiber (MMMF)-based dual Mach-Zehnder interferometer (MZI) is proposed and demonstrated for simultaneous measurement of refractive index (RI) and temperature. By inserting a section of MMMFsupporting a few modes in the sensing arm of the MZI setup, an inline interference between the fundamental mode and the high-order mode of MMMF, as well as the interference between the high-order mode of MMMF and the reference arm, i.e., the dual MZI, is realized. Due to different interference mechanisms, the former interferometer achieves RI sensitivity of 2576.584 nm/RIU and temperature sensitivity of 0.193 nm/°C, while the latter one achieves RI sensitivity of 1001.864 nm/RIU and temperature sensitivity of 0.239 nm/°C, demonstrating the ability to attain highly accurate multiparameter measurements. © 2014 Optical Society of America.