934 resultados para Mach-Zehnder interferometer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optical interference method is a promising technique for measuring temperature, density, and concentration in fluids. The non-intrusive and non-invasive nature of its optical techniques to the measured section are its most outstanding features. However, the adverse experiment environment, especially regarding shaking and vibrating, greatly restricts the application of the interferometer. In the present work, an optical diagnostic system consisting of a Mach-Zehnder interferometer (named after physicists Ludwig Mach) and an image processor has been developed that increases the measuring sensitivity compared to conventional experimental methods in fluid mechanics. An image processor has also been developed for obtaining quantitative results by using Fourier transformation. The present facility has been used in observing and measuring the mass transfer process of a water droplet in EAFP protein solution under microgravity condition provided by the satellite Shi Jian No. 8.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A planar lightwave circuit (PLC) add-drop filter is proposed and analyzed, which consists of a symmetric Mach-Zehnder interferometer (MZI) combined with double microring resonators. A critical coupling condition is derived for a better box-like drop spectrum. Comparisons of its characteristics with other schemes, such as a MZI with a single ring resonator, arepresented, and some of the issues about device design and fabrication are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel optical interleaver scheme based on nested optical glass pairs is proposed. The assembly of pairs behaves as a cascaded Mach-Zehnder interferometer. The interleaver, with simple structure, low cost, and compact size, can be easily implemented with inexpensive material and mature preparation technology. Small channel spacing (<= 50 GHz), high isolation (<-30 dB), a wide, flat passband and stop band (> 2/11 period), and center-frequency tunability can be obtained simultaneously. An optimum design of a 50-GHz tunable interleaver based on this structure is given as an example. Its environmental temperature sensitivity and fabrication tolerance are also analyzed. (c) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An all-optical parity checker is proposed that requires only a single Mach-Zehnder interferometer. Simulation results demonstrate an 8dB improvement in extinction ratio at 10 Gb/s operation. © 1999 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show for the first time that for a given switching pulse width, the maximum switching speed obtainable from a Mach-Zehnder interferometer employing semiconductor optical amplifiers is strongly dependent on the SOA chirp characteristics. © 2005 Optical Society of America.