928 resultados para MULTISLICE CT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atlases and statistical models play important roles in the personalization and simulation of cardiac physiology. For the study of the heart, however, the construction of comprehensive atlases and spatio-temporal models is faced with a number of challenges, in particular the need to handle large and highly variable image datasets, the multi-region nature of the heart, and the presence of complex as well as small cardiovascular structures. In this paper, we present a detailed atlas and spatio-temporal statistical model of the human heart based on a large population of 3D+time multi-slice computed tomography sequences, and the framework for its construction. It uses spatial normalization based on nonrigid image registration to synthesize a population mean image and establish the spatial relationships between the mean and the subjects in the population. Temporal image registration is then applied to resolve each subject-specific cardiac motion and the resulting transformations are used to warp a surface mesh representation of the atlas to fit the images of the remaining cardiac phases in each subject. Subsequently, we demonstrate the construction of a spatio-temporal statistical model of shape such that the inter-subject and dynamic sources of variation are suitably separated. The framework is applied to a 3D+time data set of 138 subjects. The data is drawn from a variety of pathologies, which benefits its generalization to new subjects and physiological studies. The obtained level of detail and the extendability of the atlas present an advantage over most cardiac models published previously. © 1982-2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. This study was designed to determine the precision and accuracy of angular measurements using three-dimensional computed tomography (3D-CT) volume rendering by computer systems. Study design. The study population consisted of 28 dried skulls that were scanned with a 64-row multislice CT, and 3D-CT images were generated. Angular measurements, (n = 6) based upon conventional craniometric anatomical landmarks (n = 9), were identified independently in 3D-CT images by 2 radiologists, twice each, and were then performed by 3D-CT imaging. Subsequently, physical measurements were made by a third examiner using a Beyond Crysta-C9168 series 900 device. Results. The results demonstrated no statistically significant difference between interexaminer and intraexaminer analysis. The mean difference between the physical and 3-D-based angular measurements was -1.18% and -0.89%, respectively, for both examiners, demonstrating high accuracy. Conclusion. Maxillofacial analysis of angular measurements using 3D-CT volume rendering by 64-row multislice CT is established and can be used for orthodontic and dentofacial orthopedic applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Vergleich von Datensätzen,die mit Hilfe von den Programmen "Volume©","Pulmo©", "Yacta©" und PulmoFUNC(ILab) erstellt wurden. Dabei wurden jeweils die Lungen- und Emphysemvolumina verglichen, die mit den 4 Programmen ermittelt wurden. Außerdem wurde noch die mittlere Lungendichte als Mittelwert aller Lungenvoxel bestimmt. Zusätzlich wurde noch der Emphysemindex als Quotient aus Emphysem- und Lungenvolumina errechnet. Die Programme waren unterschiedlich benutzerfreundlich in der Bearbeitung: Die weitestgehend manuell zu bearbeitenden Programme Volume© und Pulmo© benötigten zur Bearbeitung deutlich mehr Zeit als die überwiegend automatisch arbeitenden Programme Yacta und PulmoFUNC(ILab).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To evaluate the significance of multislice CT for the diagnosis of uncertain penetrating globe injuries.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Protective patient equipment for CT examinations is not routinely provided. The aim of this study was to determine whether, and if so what, specific protective equipment is beneficial during CT scans. The absorbed organ doses and the effective doses for thorax, abdomen/pelvis and brain CT investigation with and without the use of protective patient equipment have been determined and compared. All measurements were carried out on modern multislice CT scanner using an anthropomorphic phantom and thermoluminescence dosemeters. The measurements show that protective equipment reduces the dose within the scattered beam area. The highest organ dose reduction was found in organs that protrude from the trunk like the testes or the female breasts that can largely be covered by the protective equipment. The most reduction of the effective dose was found in the male abdomen/pelvis examination (0.32 mSv), followed by the brain (0.11 mSv) and the thorax (0.06 mSv). It is concluded that the use of protective equipment can reduce the applied dose to the patient.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS: In 44 cases, the weights of spleen and liver were estimated based on MRI and CT data using a volume-analysis software and a postmortem tissue-specific density factor. In a blinded approach, the results were compared with the weights noted at autopsy. RESULTS: Excellent correlation between estimated and real weights (r = 0.997 for MRI, r = 0.997 for CT) was found. Putrefaction gas and venous air embolism led to an overestimation. Venous congestion and drowning caused higher estimated weights. CONCLUSION: Postmortem weights of liver and spleen can accurately be assessed by nondestructive imaging. Multislice CT overcomes the limitation of putrefaction and venous air embolism by the possibility to exclude gas. Congestion seems to be even better assessed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Automatic segmentation and tracking of the coronary artery tree from Cardiac Multislice-CT images is an important goal to improve the diagnosis and treatment of coronary artery disease. This paper presents a semi-automatic algorithm (one input point per vessel) based on morphological grayscale local reconstructions in 3D images devoted to the extraction of the coronary artery tree. The algorithm has been evaluated in the framework of the Coronary Artery Tracking Challenge 2008 [1], obtaining consistent results in overlapping measurements (a mean of 70% of the vessel well tracked). Poor results in accuracy measurements suggest that future work should refine the centerline extraction. The algorithm can be efficiently implemented and its general strategy can be easily extrapolated to a completely automated centerline extraction or to a user interactive vessel extraction

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In dentistry, basic imaging techniques such as intraoral and panoramic radiography are in most cases the only imaging techniques required for the detection of pathology. Conventional intraoral radiographs provide images with sufficient information for most dental radiographic needs. Panoramic radiography produces a single image of both jaws, giving an excellent overview of oral hard tissues. Regardless of the technique, plain radiography has only a limited capability in the evaluation of three-dimensional (3D) relationships. Technological advances in radiological imaging have moved from two-dimensional (2D) projection radiography towards digital, 3D and interactive imaging applications. This has been achieved first by the use of conventional computed tomography (CT) and more recently by cone beam CT (CBCT). CBCT is a radiographic imaging method that allows accurate 3D imaging of hard tissues. CBCT has been used for dental and maxillofacial imaging for more than ten years and its availability and use are increasing continuously. However, at present, only best practice guidelines are available for its use, and the need for evidence-based guidelines on the use of CBCT in dentistry is widely recognized. We evaluated (i) retrospectively the use of CBCT in a dental practice, (ii) the accuracy and reproducibility of pre-implant linear measurements in CBCT and multislice CT (MSCT) in a cadaver study, (iii) prospectively the clinical reliability of CBCT as a preoperative imaging method for complicated impacted lower third molars, and (iv) the tissue and effective radiation doses and image quality of dental CBCT scanners in comparison with MSCT scanners in a phantom study. Using CBCT, subjective identification of anatomy and pathology relevant in dental practice can be readily achieved, but dental restorations may cause disturbing artefacts. CBCT examination offered additional radiographic information when compared with intraoral and panoramic radiographs. In terms of the accuracy and reliability of linear measurements in the posterior mandible, CBCT is comparable to MSCT. CBCT is a reliable means of determining the location of the inferior alveolar canal and its relationship to the roots of the lower third molar. CBCT scanners provided adequate image quality for dental and maxillofacial imaging while delivering considerably smaller effective doses to the patient than MSCT. The observed variations in patient dose and image quality emphasize the importance of optimizing the imaging parameters in both CBCT and MSCT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El trasplante hepático es el estándar de tratamiento de las enfermedades hepáticas agudas irreversibles y crónicas. La escanografía multicorte (ECM) es una herramienta útil que se utiliza en la selección adecuada de los candidatos a trasplante. El propósito de este estudio es determinar la efectividad de la (ECM) en la detección de lesiones hepáticas en el hígado cirrótico. METODOLOGIA: Estudio de prueba diagnóstica retrospectivo que incluye pacientes del programa de trasplante hepático de la Fundación Cardioinfantíl a los cuales se les realizo ECM en la valoración pretrasplante, realizando comparación con el resultado de la patología del hígado explantado. RESULTADOS: El 9.5% de los pacientes estudiados por tomografía, fueron diagnosticados con hepatocarcinoma celular. La sensibilidad y especificidad en la detección de hepatocarcinoma fue del 50% y del 94.87% respectivamente. DISCUSION: La prevalencia de tumores hepáticos en pacientes llevados a trasplante hepático ha sido reportada como de más del 8%. Es este estudio encontramos una prevalencia para el hepatocarcinoma de 7.14% que demuestra baja incidencia en nuestro medio para el hepatocarcinoma en pacientes trasplantados, lo que se traduce en una alta posibilidad de sobrevida. En nuestro estudio la sensibilidad del TAC multicorte para la detección de lesiones focales en general fue de 41.17 %. La sensibilidad y especificidad en la detección de hepatocarcinoma fue del 50% y del 94.87% respectivamente.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cone beam computed tomography (CBCT) can be considered as a valuable imaging modality for improving diagnosis and treatment planning to achieve true guidance for several craniofacial surgical interventions. A new concept and perspective in medical informatics is the highlight discussion about the new imaging interactive workflow. The aim of this article was to present, in a short literature review, the usefulness of CBCT technology as an important alternative imaging modality, highlighting current practices and near-term future applications in cutting-edge thought-provoking perspectives for craniofacial surgical assessment. This article explains the state of the art of CBCT improvements, medical workstation, and perspectives of the dedicated unique hardware and software, which can be used from the CBCT source. In conclusion, CBCT technology is developing rapidly, and many advances are on the horizon. Further progress in medical workstations, engineering capabilities, and improvement in independent software-some open source-should be attempted with this new imaging method. The perspectives, challenges, and pitfalls in CBCT will be delineated and evaluated along with the technological developments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The rapid development of computed tomography (CT) and magnetic resonance imaging (MRI) led to the introduction and establishment in postmortem investigations. The objectives of this preliminary study were to describe the imaging appearances of the early postmortem changes of blood after cessation of the circulation, such as sedimentation, postmortem clotting, and internal livores, and to give a few first suggestions on how to differentiate them from other forensic findings. In the Virtopsy project, 95 human corpses underwent postmortem imaging by CT and MRI prior to traditional autopsy and therefore 44 cases have been investigated in this study. Postmortem alterations as well as the forensic relevant findings of the blood, such as internal or subcutaneous bleedings, are presented on the basis of their imaging appearances in multislice CT and MRI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Europe the procedure of trepanation is known since the Neolithic and is still practiced today in East African native tribes. Trepanation is the oldest known surgical intervention and is defined as the intentional penetration of the cranial vault with removal of piece of a skull bone. Therefore, it is believed that neurosurgery is one of the world’s oldest professions. In this study two skulls with lesions from the Late Iron Age cemetery of Münsingen (420–240 BC), Switzerland, are presented. Aim of the study was to analyse the lesions and to assess whether they were caused by surgical interventions. Sex and age of the individuals were determined by current morphologic-anthropological methods. Radiological examinations were performed with a multislice CT-scanner. Different trepanation methods and signs of healing are discussed. In Switzerland about 33 skulls with possible trepanations dating from Neolithic to medieval times are known and are presented in a short review. Studies of ancient surgical interventions provide important information of pre- and early historic populations. Trepanations of the skull such as the presented cases prove a profound understanding of the human body in ancient times.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trepanation is defined as the intentional perforation of the cranial vault with removal of a piece of skull bone. In Europe, trepanation is known to have been practiced at least since the Neolithic, and it can still be found today in East African native tribes. Two skulls with lesions from the Late Iron Age site Münsingen-Rain (420–240 BC) were investigated. The aim of this study was to analyse the lesions and to determine whether they were caused by surgical interventions. Both individuals were analysed by current morphologic-anthropological methods and radiological examinations were performed with a multislice CT-scanner. Additionally, this work surveys trepanations reported in Switzerland and calculates survival rates. In Switzerland, 34 individuals with trepanations have been published. As a tendency, the survival rate appears to be relatively high from the Neolithic to Late Antiquity but then decreases until Pre-Modern times. The 78% survival rate in Late Iron Age Switzerland indicates that the surgery was often performed successfully. Skull injuries sustained in conflicts could have been a reason for trepanation during the Iron Age.