366 resultados para MRSA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this preliminary study eighteen p-substituted benzoic acid [(5-nitro-thiophen-2-yl)-methylene]-hydrazides with antimicrobial activity were evaluated against multidrug-resistant Staphylococcus aureus, correlating the three-dimensional characteristics of the ligands with their respective bioactivities. The computer programs Sybyl and CORINA were used, respectively, for the design and three-dimensional conversion of the ligands. Molecular interaction fields were calculated using GRID program. Calculations using Volsurf resulted in a statistically consistent model with 48 structural descriptors showing that hydrophobicity is a fundamental property in the analyzed biological response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. To identify risk factors associated with nosocomial bloodstream infections caused by multiple clones of the staphylococcal cassette chromosome mec (SCCmec) type IV strain of methicillin-resistant Staphylococcus aureus (MRSA). DESIGN. An unmatched case-control study (at a ratio of 1 : 2) performed during the period from October 2002 through September 2003. SETTING. A 2,000-bed tertiary care teaching hospital affiliated with the University of Sao Paulo in Sao Paulo, Brazil. METHODS. Case patients (n = 30) were defined either as patients who had a bloodstream infection due to SCCmec type IV strains of MRSA diagnosed at least 48 hours after hospital admission or as neonates with the infection who were born in the hospital. Control patients (n = 60) were defined as patients with SCCmec type III MRSA infection diagnosed at least 48 hours after hospital admission. Genes n = 60 encoding virulence factors were studied in the isolates recovered from case patients, and molecular typing of the SCCmec type IV MRSA isolates was also done by pulsed-field gel electrophoresis and multilocus sequence typing. RESULTS. In multivariate analysis, the following 3 variables were significantly associated with having a nosocomial bloodstream infection caused by SCCmec type IV strains of MRSA: an age of less than 1 year, less frequent use of a central venous catheter (odds ratio [OR], 0.07 [95% confidence interval {CI}, 0.02-0.28]; P = .001), and female sex. A second analysis was performed that excluded the case and Pp. 001 control patients from the neonatal unit, and, in multivariate analysis, the following variables were significantly associated with having a nosocomial bloodstream infection caused by SCCmec type IV strains of MRSA: less frequent use of a central venous catheter (OR, 0.12 [95% CI, 0.03-0.55]; P = .007), lower Acute Physiology and Chronic Health Evaluation II score on admission (OR, 0.14 [95% CI, 0.03-0.61];), less frequent surgery (OR, 0.21 [95% CI, 0.06-0.83];), and female sex (OR, 5.70 [95% CI, 1.32-24.66]; P =.020). P = .009 Pp. 025 Pp). Of the 29 SCCmec type IV MRSA isolates recovered from case patients, none contained the Panton-Valentine leukocidin, gamma-hemolysin, enterotoxin B or C, or toxic shock syndrome toxin-1. All of the isolates contained genes for the LukE-LukD leukocidin and alpha-hemolysin. Genes for enterotoxin A were present in 1 isolate, and genes for beta-hemolysin were present in 3 isolates. CONCLUSIONS. ""Classical"" risk factors do not apply to patients infected with the SCCmec type IV strain of MRSA, which is an important cause of nosocomial bacteremia. This strain infects a patient population that is less ill and has had less frequent invasive procedures than a patient population infected with the multidrug-resistant strain of SCCmec type III MRSA. We found that virulence factors were rare and that Panton-Valentine leukocidin was absent. There were multiple clones of the SCCmec type IV strain in our hospital. Children under 1 year of age were at a higher risk. There was a predominant clone ( sequence type 5) in this patient population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO:Staphylococcus aureus é um dos principais agentes patogénicos humanos, sendo frequentemente associado a infecções nosocomiais e infecções na comunidade. A prevalência de S. aureus resistentes à meticilina (MRSA) em hospitais portugueses é uma das mais elevadas da Europa e tem sido caracterizada extensivamente; contrariamente, a prevalência e epidemiologia de MRSA na comunidade em Portugal não tem sido devidamente seguida. Com o objectivo de compreender as causas possíveis do aumento na frequência de MRSA num dos maiores hospitais centrais portugueses (HSM) ao longo de 17 anos, isolados de MRSA recolhidos em 1993 (n=54) e 2010 (n=180) de pus, sangue e urina foram analisados por PFGE, MLST, tipagem do spa e tipagem de SCCmec. Os resultados mostraram que ocorreu uma mudança global nos tipos clonais predominantes, onde o clone ST22-IVh substituiu os clones, ST239-IIIvar e ST247-I, representando mais de 70% da população actual. Além disso, entre 1993 e 2010 verificou-se um aumento na diversidade genética dos tipos clonais de MRSA. Para determinar a frequência e a natureza clonal de MRSA e S. aureus sensíveis à meticilina (MSSA) isolados de infecções de pele e tecidos moles (SSTI) em pessoas que frequentam centros de saúde em Portugal, 73 amostras foram recolhidas em nove centros de saúde (Rede Médicos Sentinela). Isolou-se um total de 40 S. aureus (55%), dos quais 17,5% eram MRSA. Os isolados de MRSA pertenciam aos clones ST22-IVh (n=4), ST5-IVc (n=2) e ST105-II (n=1), que foram descritos neste estudo como sendo clones de origem hospitalar. Os nossos resultados sugerem que o aumento da frequência de MRSA no HSM pode estar associado à emergência de um clone de MRSA com maior capacidade epidémica. Além disso, verificámos que a principal causa de SSTI em pessoas que frequentam centros de saúde em Portugal são MRSA de origem hospitalar e não MRSA associados à comunidade.------ABSTRACT: Staphylococcus aureus is one of the most important human pathogens, being a major cause of infections worldwide both in the hospital and in the community. In Portugal, the prevalence of methicillin resistant S. aureus (MRSA) in hospitals is one of the highest in Europe and has been characterized extensively; contrarily the prevalence and epidemiology of MRSA in the community has not been followed in a meaningful way. To understand the epidemiological events that could explain a steep increase in MRSA frequency in a major Portuguese central hospital (HSM) within a 17 year period, two MRSA collections recovered in 1993 (n=54) and 2010 (n=180) from pus, blood and urine were analyzed by PFGE, MLST, spa and SCCmec typing. The results showed that a major clonal shift occurred, wherein ST22-IVh clone has replaced the previous ST239-IIIvar and ST247-I clones and accounts for more than 70% of the present population. Moreover, an increase in genetic diversity of MRSA clonal types was observed between the two study periods. With the aim of determining the frequency and clonal nature of MRSA and methicillin-susceptible S. aureus (MSSA) causing skin and soft tissue infections (SSTI) in patients attending healthcare centers in Portugal, 73 samples were collected from nine healthcare centers (Medicos Sentinela Network). A total of 40 S. aureus were isolated, accounting for 55% of the SSTI, of which 17.5% were MRSA. MRSA isolates belonged to ST22-IVh (n=4), ST5-IVc (n=2) and ST105-II (n=1) that have also been described in the hospital in an equivalent period. Our results suggest that the increase in MRSA frequency in HSM may be associated to the emergence of a MRSA clone with higher epidemic potential. Moreover, we propose that the spillover of MRSA from the hospital rather than community-associated-MRSA was the main cause of SSTI in persons attending healthcare centers in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methicillin-resistant Staphylococcus aureus (MRSA), a human pathogen confined to hospitals (HAMRSA) for over 30 years have been emerging worldwide in the last two decades as a leading cause of severe infections in healthy individuals in the community (CA-MRSA). Despite its clinical significance, in the beginning of our studies no information existed on the prevalence, and population structure of CA-MRSA in Portugal. Moreover, it remained to be clarified how CA-MRSA emerged in our country. In particular, it was not known if CA-MRSA emerged locally by acquisition of the staphylococcal cassette chromosome mec (SCCmec) by established methicillin-susceptible S. aureus (MSSA) in the community, if they were imported from abroad or have escaped from the hospital.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Methicillin-resistant Staphylococcus aureus (MRSA) is among the most important pathogens of nosocomial infections, mainly in intensive care units (ICUs), and accounts for 40-60% of all healthcare-associated S. aureus infections. We evaluated the incidence of nosocomial infection by S. aureus, identified the risk factors for MRSA infection, and evaluated the effect of resistance to methicillin on mortality in patients. Methods We conducted MRSA surveillance at a university hospital in Brazil from January 1, 2010, to December 31, 2010, and performed a retrospective case-control matched study to evaluate the frequency of subsequent MRSA bacteremia and death among patients. We evaluated and compared the risk factors between patients with MRSA and methicillin-sensitive Staphylococcus aureus (MSSA) infection. Results Sepsis was the most common cause of infection (17.7/1,000 patient-days), followed by surgical site (11.4/1,000 patient-days), pneumonia (4.1/1,000 patient-days), and urinary tract infection (2.4/1,000 patient-days). The significant risk factors were time of hospitalization, use of central vascular catheter (CVC), urinary catheter, nasogastric tube, parenteral nutrition, tracheostomy, mechanical ventilation, and previous antibiotic administration, the latter of which was the only independent risk factor for MRSA infection. Mortality was significantly higher in patients with MRSA. The number of antibiotics tested was not related to increases in the frequency of MRSA/1,000 patient-days. The incidence of mortality attributable to MRSA (bloodstream infection) BSI was 50%. Conclusions Surveillance results showed that the use of high levels of antibiotics was directly related to the development of MRSA infection, and the mortality attributable to MRSA in patients with bacteremia was significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract:INTRODUCTION:The frequency of methicillin-resistant Staphylococcus aureus (MRSA) has increased in the community. This study evaluated the prevalence of MRSA and community-acquired (CA)-MRSA in 120 healthy elderly.METHODS:The MRSA were evaluated for the presence of the IS256, mecA, agr, icaA, icaD, fnbB , and pvl genes with PCR. Results: Frequency of S. aureus and MRSA colonization was 17.8% and 19%, respectively. CA-MRSA isolate showed SCC mec IV, fnbB+ , and icaD+ .CONCLUSIONS:CA-MRSA was detected, with genotype determined as SCC mec type IV/IS256/ fnbB+ / icaA / icaD+ / bbp-/agr2 / bap / pvl, characterizing this population as a possible reservoir of this organism in the community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Staphylococcus aureus is an important opportunistic pathogen that can cause a wide variety of diseases from mild to life-threatening conditions. S. aureus can colonize many parts of the human body but the anterior nares are the primary ecological niche. Its clinical importance is due to its ability to resist almost all classes of antibiotics available together with its large number of virulence factores. MRSA (Methicillin-Resistant S. aureus) strains are particularly important in the hospital settings, being the major cause of nosocomial infections worldwide. MRSA resistance to β-lactam antibiotics involves the acquisition of the exogenous mecA gene, part of the SCCmec cassette. Fast and reliable diagnostic techniques are needed to reduce the mortality and morbidity associated with MRSA infections, through the early identification of MRSA strains. The current identification techniques are time-consuming as they usually involves culturing steps, taking up to five days to determine the antibiotic resistance profile. Several amplification-based techniques have been developed to accelerate the diagnosis. The aim of this project was to develop an even faster methodology that bypasses the DNA amplification step. Gold-nanoprobes were developed and used to detect the presence of mecA gene in S. aureus genome, associated with resistance traits, for colorimetric assays based on non-crosslinking method. Our results showed that the mecA and mecA_V2 gold-nanoprobes were sensitive enough to discriminate the presence of mecA gene in PCR products and genomic DNA (gDNA) samples for target concentrations of 10 ng/μL and 20 ng/μL, respectively. As our main objective was to avoid the amplification step, we concluded that the best strategy for the early identification of MRSA infection relies on colorimetric assays based on non-crosslinking method with gDNA samples that can be extracted directly from blood samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methicillin-resistant staphlococcus aureus – MRSA is the most significant antibiotic resistant bacteria found in our hospitals The first MRSA survey on the prevalence of MRSA in the South of Ireland was conducted in 1995 under the direction of the late Dr. Zachary Johnson. In 1998 the Eastern Health Board was financed to carry out a repeat study again under Dr. Johnsonâ?Ts direction. This repeat study was done on an all island basis and the findings from both parts of the island are presented jointly in this reportDownload the Report here

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prevention and Control Methicillin-Resistant Staphylococcus aureus (MRSA) National Clinical Guideline No. 2   Click here to download National Clinical Guideline – MRSA  PDF 1MB Click here to download National Clinical Guideline – MRSA (Summary) PDF 389KB Click here to download the Presentation at the Launch of the 2nd National Clinical Guideline Prevention and Control of Methicillin-Resistant Staphylococcus aureus (MRSA)PDF 1.04MB  

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The risk of carrying methicillin-resistant Staphylococcus aureus (MRSA) is higher among nursing home (NH) residents than in the general population. However, control strategies are not clearly defined in this setting. In this study, we compared the impact of standard precautions either alone (control) or combined with screening of residents and decolonization of carriers (intervention) to control MRSA in NHs. DESIGN Cluster randomized controlled trial SETTING NHs of the state of Vaud, Switzerland PARTICIPANTS Of 157 total NHs in Vaud, 104 (67%) participated in the study. INTERVENTION Standard precautions were enforced in all participating NHs, and residents underwent MRSA screening at baseline and 12 months thereafter. All carriers identified in intervention NHs, either at study entry or among newly admitted residents, underwent topical decolonization combined with environmental disinfection, except in cases of MRSA infection, MRSA bacteriuria, or deep skin ulcers. RESULTS NHs were randomly allocated to a control group (51 NHs, 2,412 residents) or an intervention group (53 NHs, 2,338 residents). Characteristics of NHs and residents were similar in both groups. The mean screening rates were 86% (range, 27%-100%) in control NHs and 87% (20%-100%) in intervention NHs. Prevalence of MRSA carriage averaged 8.9% in both control NHs (range, 0%-43%) and intervention NHs (range, 0%-38%) at baseline, and this rate significantly declined to 6.6% in control NHs and to 5.8% in intervention NHs after 12 months. However, the decline did not differ between groups (P=.66). CONCLUSION Universal screening followed by decolonization of carriers did not significantly reduce the prevalence of the MRSA carriage rate at 1 year compared with standard precautions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information for patients and visitors on MRSA and how to prevent the spread of infection.Accessible formatsThe below document is available as a pdf and in accessible formats. Accessible formats are alternatives to printed information, used by people who are blind or visually impaired. These accessible formats include HTML, audio and braille. �For audio and HTML copies please click on the links below. For braille copies please contact Caroline McGeary on 0300 555 0114.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary Tables for Clostridium difficile and MRSA (Meticillin Resistant Staphylococcus aureus) cases 2006/07 to 2014/15